Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Circ Arrhythm Electrophysiol ; 14(11): e009790, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34719235

RESUMO

BACKGROUND: When presenting for atrial fibrillation (AF) ablation, women, compared with men, tend to have more nonpulmonary vein triggers and advanced atrial disease. Whether this informs differences in AF ablation strategy is not well described. We aimed to characterize ablation strategy and complications by sex, using the Get With The Guidelines-AF registry. METHODS: From the Get With The Guidelines-AF registry ablation feature, we included patients who underwent initial AF ablation procedure between January 7, 2016, and December 27, 2019. Patients were stratified based on AF type (paroxysmal versus nonparoxysmal) and sex. We compared patient demographics, ablation strategy, and complications by sex. RESULTS: Among 5356 patients from 31 sites who underwent AF ablation, 1969 were women (36.8%). Women, compared with men, were older (66.8±9.6 versus 63.4±10.6, P<0.0001) and were more likely to have paroxysmal AF (59.4% versus 49.5%, P<0.0001). In women with nonparoxysmal AF, left atrial linear ablation was more frequent (roof line: 53.9% versus 45.3%, P=0.0002; inferior mitral isthmus line: 10.2% versus 7.0%, P=0.01; floor line: 46.1% versus 40.6%, P=0.02) than in men. In multivariable analysis, the association between patient sex and complications from ablation was not statistically significant. CONCLUSIONS: In this US wide AF ablation quality improvement registry, women with nonparoxysmal AF were more likely to receive adjunctive lesion sets compared with men. These findings suggest that patient sex may inform ablation strategy in ways that may not be strongly supported by evidence and emphasize the need to clarify optimal ablation strategies by sex.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/normas , Complicações Pós-Operatórias/epidemiologia , Guias de Prática Clínica como Assunto , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Distribuição por Sexo , Fatores Sexuais , Estados Unidos/epidemiologia
2.
Am Heart J ; 208: 110-119, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30502925

RESUMO

BACKGROUND: Approaches, tools, and technologies for atrial fibrillation (AF) ablation have evolved significantly since its inception. We sought to characterize secular trends in AF ablation success rates. METHODS: We performed a systematic review and meta-analysis of AF ablation from January 1, 1990, to August 1, 2016, searching PubMed, Scopus, and Cochrane databases. Major exclusion criteria were insufficient outcome reporting and ablation strategies that were not prespecified and uniform. We stratified treatment arms by AF type (paroxysmal AF; nonparoxysmal AF) and analyzed single-procedure outcomes. Multivariate meta-regressions analyzed effects of study, patient, and procedure characteristics on success rate trends. Registered in PROSPERO (CRD42016036549). RESULTS: A total of 180 trials and observational studies with 28,118 patients met inclusion. For paroxysmal AF ablation studies, unadjusted success rate summary estimates ranged from 73.1% in 2003 to 77.1% in 2016, increasing by 0.9%/year (95% CI 0.4%-1.4%; P = .001; I2 = 90%). After controlling for study design and patient demographics, rate of improvement in success rate summary estimate increased (1.6%/year; 95% CI 0.9%-2.2%; P = .001; I2 = 87%). For nonparoxysmal AF ablation studies, unadjusted success rate summary estimates ranged from 70.0% in 2010 to 64.3% in 2016 (1.1%/year; 95% CI -1.3% to 3.5%; P = .37; I2 = 85%), with no improvement in multivariate analyses. CONCLUSIONS: Despite substantial research investment and health care expenditure, improvements in AF ablation success rates have been incremental. Meaningful improvements may require major paradigm or technology changes, and evaluation of clinical outcomes such as mortality and quality of life may prove to be important going forward.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/tendências , Ablação por Cateter/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Observacionais como Assunto/estatística & dados numéricos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Análise de Regressão , Resultado do Tratamento
3.
J Am Heart Assoc ; 8(1): e009976, 2019 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-30587059

RESUMO

Background The objective was to explore the efficacy of ablation lesion sets in addition to pulmonary vein isolation ( PVI ) for paroxysmal atrial fibrillation. The optimal strategy for catheter ablation of paroxysmal atrial fibrillation is debated. Methods and Results The SMASH-AF (Systematic Review and Meta-analysis of Ablation Strategy Heterogeneity in Atrial Fibrillation) study cohort includes trials and observational studies identified in PubMed, Scopus, and Cochrane databases from January 1 1990, to August 1, 2016. We included studies reporting single procedure paroxysmal atrial fibrillation ablation success rates. Exclusion criteria included insufficient reporting of outcomes, ablation strategies that were not prespecified and uniform, and a sample size of fewer than 40 patients. We analyzed lesion sets performed in addition to PVI ( PVI plus) using multivariable random-effects meta-regression to control for patient, study, and procedure characteristics. The analysis included 145 total studies with 23 263 patients ( PVI- only cohort: 115 studies, 148 treatment arms, 16 500 patients; PVI plus cohort: 39 studies; 46 treatment arms, 6763 patients). PVI plus studies, as compared with PVI -only studies, included younger patients (56.7 years versus 58.8 years, P=0.001), fewer women (27.2% versus 32.0% women, P=0.002), and were more methodologically rigorous with longer follow-up (29.5 versus 17.1 months, P 0.004) and more randomization (19.4% versus 11.8%, P<0.001). In multivariable meta-regression, PVI plus studies were associated with improved success (7.6% absolute improvement [95% CI, 2.6-12.5%]; P<0.01, I2=88%), specifically superior vena cava isolation (4 studies, 4 treatment arms, 1392 patients; 15.1% absolute improvement [95% CI, 2.3-27.9%]; P 0.02, I2=87%). However, residual heterogeneity was large. Conclusions Across the paroxysmal atrial fibrillation ablation literature, PVI plus ablation strategies were associated with incremental improvements in success rate. However, large residual heterogeneity complicates evidence synthesis.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Humanos
4.
J Cardiovasc Electrophysiol ; 29(5): 747-755, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29364570

RESUMO

INTRODUCTION: We performed a systematic review and meta-analysis of geographic and racial representation and reported success rates of studies of catheter ablation for atrial fibrillation (AF). METHODS AND RESULTS: We searched PubMed, Scopus, and Cochrane databases from 1/1/1990 to 8/1/2016 for trials and observational studies reporting AF ablation outcomes. Major exclusion criteria were insufficient reporting of outcomes, non-English language articles, and ablation strategies that were not prespecified and uniform. We described geographic and racial representation and single-procedure ablation success rates by country, controlling for patient demographics and study design characteristics. The analysis cohort included 306 studies (49,227 patients) from 28 countries. Over half of the paroxysmal (PAF) and nonparoxysmal AF (NPAF) treatment arms were conducted in 5 and 3 countries, respectively. Reporting of race or ethnicity demographics and outcomes were rare (1 study, 0.3%) and nonexistent, respectively. Unadjusted success rates by country ranged from 63.5% to 83.0% for PAF studies and 52.7% to 71.6% for NPAF studies, with substantial variation in patient demographics and study design. After controlling for covariates, South Korea and the United States had higher PAF ablation success rates, with large residual heterogeneity. NPAF ablation success rates were statistically similar by country. CONCLUSIONS: Studies of AF ablation have substantial variation in patient demographics, study design, and reported outcomes by country. There is limited geographic representation of trials and observational studies of AF ablation and a paucity of race- or ethnicity-stratified results. Future AF ablation studies and registries should aim to have broad representation by race, geography, and ethnicity to ensure generalizability.


Assuntos
Fibrilação Atrial/etnologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Etnicidade , Disparidades em Assistência à Saúde/etnologia , Grupos Raciais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etnologia , Projetos de Pesquisa , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
J Reprod Infertil ; 13(1): 3-11, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23926519

RESUMO

The number of couples seeking consultation for infertility problems has steadily increased over the past decade, affecting 10%-15% of the sexually active population. Abnormal semen production, a male factor infertility (MFI), is thought to be the cause of up to 50% of all infertilities in developed countries. There are potentially many different causes of male infertility, including hormonal, anatomical, and secondary to exposure to exogenous substances. In many cases of MFI, a definitive cause for abnormalities is never identified. Recently, the research community has given greater attention to identifying causes of MFI ranging from genetic Y chromosome microdeletions to mechanisms of environmental damage on sperm production. Still evolving, is a clear understanding of how many pharmaceutical medications may cause MFI, which is often treatable and reversible. In this review we will outline the data regarding various pharmaceutical medications that have been investigated as possible causes of MFI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...