1.
Clin Radiol ; 77(6): e425-e433, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35351291

RESUMO

AIM: To evaluate the diagnostic value of spectral detector computed tomography (SDCT)-derived iodine overlay maps and low-energy virtual mono-energetic images (VMI) for the initial locoregional assessment of primary, therapy-naive head and neck cancer. MATERIALS AND METHODS: Fifty-six patients with histologically confirmed untreated squamous cell carcinoma of the head and neck who underwent SDCT of the neck for staging purposes were included in this retrospective study. Attenuation, image noise as well as signal- and contrast-to-noise ratios (S-/CNR) in VMI40-70keV were obtained from region of interest (ROI)-based measurements in the tumour and important anatomical landmarks (sternocleidomastoid muscle, subcutaneous fat, thyroid gland, submandibular gland, carotid artery, and jugular vein). Tumour conspicuity and delineation, as well as subjective image quality, were rated for conventional images, VMI40-70keV, and iodine overlay maps using five-point Likert scales. RESULTS: The CNR of the tumour versus the floor of the mouth and the CNR of the tumour versus the sternocleidomastoid muscle was significantly higher in VMI40keV in comparison to conventional images (10.0 ± 7.3 versus 3.8 ± 3.3 and 11.3 ± 7.6 versus 3.6 ± 2.8; p<0.05 each). This was supported by qualitative results, as tumour conspicuity and delineation received superior ratings in iodine overlay maps and VMI40keV compared to conventional images (5 [3-5] and 5 [4-5] versus 3 [2-5]; 5 [2-5] and 5 [3-5] versus 3 [2-4], respectively, all p<0.05). VMI40keV yielded the highest score among all included image reconstructions for overall image quality (p<0.05 all). CONCLUSION: Iodine overlay maps and low-energy VMI derived from SDCT improve initial assessment of primary squamous cell carcinoma of the head and neck compared to conventional images.


Assuntos
Neoplasias de Cabeça e Pescoço , Iodo , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
2.
J Clin Neurosci ; 89: 33-38, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34119289

RESUMO

BACKGROUND: Complete reperfusion (mTICI 3) in anterior circulation ischemic stroke patients after a single mechanical thrombectomy (MT) pass has been identified as a predictor of favorable outcome (modified Rankin Score 0-2) and defined as true first-pass effect recently. This effect has not yet been demonstrated in posterior circulation ischemic stroke. We hypothesized a true first-pass effect for the subgroup of acute basilar artery occlusions (BAO). METHODS: Consecutive patients with acute thromboembolic occlusions in the posterior circulation, treated between 2010 and 2017, were screened and all BAO patients with complete angiographic reperfusion and known symptom onset included for unmatched and matched analysis after adjustment for multiple confounding factors (demographics, time intervals, stroke severity, posterior circulation Alberta Stroke Program early computed tomography Score and comorbidity. The primary objective was outcome at 90 days between matched cohorts of single pass vs. multi pass complete reperfusion patients. RESULTS: 90 MTs in BAO were analyzed, yielding 56 patients with known symptom onset, in whom we achieved complete reperfusion (mTICI 3), depending on whether complete reperfusion was achieved after a single pass (n = 28) or multiple passes (n = 28). Multivariable analysis of 56 non-matched patients revealed a significant association between first-pass complete reperfusion and favorable outcome (p < 0.01). In matched cohorts (n = 7 vs. n = 7), favorable outcome was only seen if complete reperfusion was achieved after a single pass (86% vs. 0%). CONCLUSION: Single pass complete reperfusion in acute basilar artery occlusion is an independent predictor of favorable outcome. Achieving complete reperfusion after multiple passes might impair favorable patient recovery.


Assuntos
Artéria Basilar/cirurgia , Revascularização Cerebral/métodos , Transtornos Cerebrovasculares/cirurgia , Acidente Vascular Cerebral/cirurgia , Trombectomia/tendências , Idoso , Idoso de 80 Anos ou mais , Artéria Basilar/diagnóstico por imagem , Transtornos Cerebrovasculares/complicações , Transtornos Cerebrovasculares/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reperfusão/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Trombectomia/métodos , Resultado do Tratamento
3.
AJNR Am J Neuroradiol ; 42(3): 516-523, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33384288

RESUMO

BACKGROUND AND PURPOSE: CTA provides a noninvasive alternative technique to DSA in the follow-up after endovascular aneurysm treatment to evaluate aneurysm occlusion and exclude intraluminal narrowing after stent or flow-diverter implantation; however, assessability may be impeded by stent material artifacts. The objective of this in vitro study was to compare the visual assessability of different conventional stents and flow diverters as well as different reconstructions of dual-layer CT images. MATERIALS AND METHODS: Four conventional intracranial stents and 4 flow diverters were implanted in identical aneurysm phantoms. Conventional and monoenergetic images (40, 50, 60, 90, 120, 180 keV) were acquired to evaluate attenuation alteration, visible lumen diameter, and SNR. Image quality was rated subjectively by 2 independent radiologists using a 4-point Likert scale. RESULTS: Low kiloelectron volt (40-60 keV) monoenergetic reconstructions showed an improved SNR and an improved lumen density ratio compared with high kiloelectron volt reconstructions (90-180 keV) and conventional reconstructions, however without reaching significance compared with the latter. Assessment of the adjacent aneurysm and subjective evaluation was not affected by the imaging technique and stent type. Artifact susceptibility varied with the device used and increased among flow diverters. CONCLUSIONS: Low kiloelectron volt reconstructions improved the assessment of the stent lumen in comparison with high kiloelectron volt reconstructions. No significant improvement in image quality could be shown compared with conventional images. For some devices, iodine-specific reconstructions led to severe artifacts and are therefore not recommended. There was no relevant improvement in the assessability of the adjacent aneurysm.


Assuntos
Aneurisma/diagnóstico por imagem , Aneurisma/terapia , Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Stents
4.
Eur Radiol ; 31(6): 4148-4155, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33341907

RESUMO

OBJECTIVES: The objective of this study was to compare clinical outcome and procedural differences of mechanical thrombectomy (MT) during on-call with regular operating hours. We particularly focused on dosimetric data which may serve as potential surrogates for patient outcome. METHODS: A total of 246 consecutive patients who underwent MT in acute anterior circulation stroke between November 2017 and March 2020 were retrospectively included. Patients treated (1) during standard operational hours (n = 102), (2) daytime on-call duty (n = 38) and (3) nighttime on-call duty (n = 106) were compared with respect to their pre-interventional status, procedural specifics, including dosimetrics (dose area product (DAP), fluoroscopy time and procedural time), and outcome. RESULTS: The collectives treated outside the regular operational hours showed an increased in-hospital mortality (standard operational hours 7% (7/102), daytime on-call duty 16% (6/38), nighttime on-call duty 20% (21/106), p = 0.02). Neither the dosimetric parameters nor baseline characteristics other procedural specifics and outcome parameters differed significantly between groups (p > 0.05 each). In most cases (> 90%), a successful reperfusion was achieved (TICI ≥ 2b). CONCLUSIONS: We found an increased in-hospital mortality in patients admitted at night and during weekends which was not explained by technical aspects of MT. KEY POINTS: • There is an increased mortality of stroke patients admitted at night and on weekends. • This is not explained by technical aspects of mechanical thrombectomy. • There were no statistical differences in the comparison of parameters linked to the radiation exposure, such as DAP, fluoroscopy time and procedure time.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Reperfusão , Estudos Retrospectivos , Acidente Vascular Cerebral/terapia , Trombectomia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...