2.
Eur J Nucl Med Mol Imaging ; 48(5): 1511-1521, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33140131

RESUMO

BACKGROUND AND AIM: High dose brachytherapy using a non sealed 188Re-resin (Rhenium-SCT®, Oncobeta® GmbH, Munich, Germany) is a treatment option for non-melanoma skin cancer (NMSC). The aim of this prospective study was to assess the efficacy and the safety of a single application of Rhenium-SCT® in NMSC. MATERIALS AND METHOD: Fifty consecutive patients (15F, 35 M, range of age 56-97, mean 81) showing 60 histologically proven NMSCs were enrolled and treated with the Rhenium-SCT® between October 2017 and January 2020. Lesions were located on the face, ears, nose or scalp (n = 46), extremities (n = 9), and trunk (n = 5). Mean surface areas were 7.0 cm2 (1-36 cm2), mean thickness invasion was 1.1 mm (0.2-2.5 mm), and mean treatment time was 79 min (21-85 min). Superficial, mean, and target absorbed dose were 185 Gy, 63 Gy, and 31 Gy respectively. Patients were followed-up at 14, 30, 60, 90, and 180 days posttreatment, when dermoscopy and biopsy were performed. Mean follow-up was 20 months (range 3-33 months). Early skin toxicity was classified according to Common Terminology Criteria for Adverse Events (CTCAE). Cosmetic results were evaluated after at least 12 months according to Radiation Therapy Oncology Group (RTOG) scale. RESULTS: At 6 months follow-up, histology and dermoscopy were available for 54/60 lesions, of which 53/54 (98%) completely responded. One patient showed a 1-cm2 residual lesion that was subsequently surgically excised. Twelve months after treatment, 41/41 evaluable lesions were free from relapse. Twenty four months after treatment, 23/24 evaluable lesions were free of relapse. In 56/60 lesions early side effects, resolving within 32 days were classified as grades 1-2 (CTCAE). In the remaining 4/60 lesions, these findings were classified as grade 3 (CTCAE) and lasted up to 8-12 weeks but all resolved within 90 days. After at least 12 months (12-33 months), cosmetic results were excellent (30 lesions) or good (11 lesions). CONCLUSION: High dose brachytherapy with Rhenium-SCT® is a noninvasive, reasonably safe, easy to perform, effective and well-tolerated approach to treat NMSCs, and it seems to be a useful alternative option when surgery or radiation therapy are difficult to perform or not recommended. In our population 98% of the treated lesions resolved completely after a single application and only one relapsed after 2 years. Larger patients' population and longer follow-up are needed to confirm these preliminary data and to find the optimal dose to administer in order to achieve complete response without significant side effects.


Assuntos
Braquiterapia , Rênio , Neoplasias Cutâneas , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/efeitos adversos , Alemanha , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Estudos Prospectivos , Rênio/uso terapêutico , Neoplasias Cutâneas/radioterapia
3.
Phys Med Biol ; 63(18): 185021, 2018 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-30229740

RESUMO

Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4 solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801-3). Moreover, the impact of 9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced 99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard 99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (E γ > 200 keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced 99mTc using 100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7-19.4 MeV, the resulting image properties are well comparable with those from the generator-eluted 99mTc.


Assuntos
Compostos Radiofarmacêuticos/normas , Tecnécio/normas , Ciclotrons , Isótopos/química , Molibdênio/química , Prótons , Compostos Radiofarmacêuticos/química , Pertecnetato Tc 99m de Sódio/química , Tecnécio/química
4.
Appl Radiat Isot ; 113: 22-7, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27108071

RESUMO

Radionuclide activity meters ("dose calibrators") are ionization chambers designed to measure relatively high amount of activities which are normally contained in radiopharmaceuticals. However, in the current radiopharmacy practice, these radiation detectors have been proposed to be used in measurements of samples with lower activity, such as in routine quality control (QC) tests. To check the feasibility of such measurements, in this work we assessed the performance of four different devices in the lower range of detectability, by means of experimental measurements of a radioactive sample. Accuracy and precision of each device was evaluated as a function of the activity contained in the sample in order to estimate a threshold value, or minimum detectable activity (MDA), which, according to our operational definition, may be used to express the concept of Limit of Quantification (LoQ). Moreover, a generalized procedure for the estimation of the MDA was established, which, being device- and radionuclide-independent, it may be adopted by every laboratory. Our results showed a significant variability in the MDA achieved by different activity meters. Hence a single QC test may result feasible with one specific instrument, and not with another one. Moreover, feasibility depends also on the confidence level required for each test. For these reasons, each activity meter should be qualified for its MDA or LoQ by each laboratory according to a procedure such as that described in this paper.


Assuntos
Radioisótopos/análise , Radiometria/instrumentação , Compostos Radiofarmacêuticos/análise , Desenho de Equipamento , Humanos , Limite de Detecção , Controle de Qualidade , Dosímetros de Radiação , Radioisótopos/normas , Radiometria/normas , Compostos Radiofarmacêuticos/normas , Tecnécio/análise , Tecnécio/normas
5.
Appl Radiat Isot ; 94: 158-165, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25195174

RESUMO

Accurate determination of calibration factors for radionuclide activity meters is crucial for quantitative studies and in the optimization step of radiation protection, as these detectors are widespread in radiopharmacy and nuclear medicine facilities. In this work we developed the Monte Carlo model of a widely used activity meter, using the Geant4 simulation toolkit. More precisely the "PENELOPE" EM physics models were employed. The model was validated by means of several certified sources, traceable to primary activity standards, and other sources locally standardized with spectrometry measurements, plus other experimental tests. Great care was taken in order to accurately reproduce the geometrical details of the gas chamber and the activity sources, each of which is different in shape and enclosed in a unique container. Both relative calibration factors and ionization current obtained with simulations were compared against experimental measurements; further tests were carried out, such as the comparison of the relative response of the chamber for a source placed at different positions. The results showed a satisfactory level of accuracy in the energy range of interest, with the discrepancies lower than 4% for all the tested parameters. This shows that an accurate Monte Carlo modeling of this type of detector is feasible using the low-energy physics models embedded in Geant4. The obtained Monte Carlo model establishes a powerful tool for first instance determination of new calibration factors for non-standard radionuclides, for custom containers, when a reference source is not available. Moreover, the model provides an experimental setup for further research and optimization with regards to materials and geometrical details of the measuring setup, such as the ionization chamber itself or the containers configuration.


Assuntos
Modelos Estatísticos , Método de Monte Carlo , Radioisótopos/análise , Radiometria/instrumentação , Radiometria/normas , Software , Algoritmos , Calibragem , Simulação por Computador , Análise de Falha de Equipamento/normas , Internacionalidade , Radioisótopos/normas , Radiometria/métodos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Appl Radiat Isot ; 75: 105-14, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23501360

RESUMO

In this work we developed a Monte Carlo (MC) model of the Sedecal Argus pre-clinical PET scanner, using GATE (Geant4 Application for Tomographic Emission). This is a dual-ring scanner which features DOI compensation by means of two layers of detector crystals (LYSO and GSO). Geometry of detectors and sources, pulses readout and selection of coincidence events were modeled with GATE, while a separate code was developed in order to emulate the processing of digitized data (for example, customized time windows and data flow saturation), the final binning of the lines of response and to reproduce the data output format of the scanner's acquisition software. Validation of the model was performed by modeling several phantoms used in experimental measurements, in order to compare the results of the simulations. Spatial resolution, sensitivity, scatter fraction, count rates and NECR were tested. Moreover, the NEMA NU-4 phantom was modeled in order to check for the image quality yielded by the model. Noise, contrast of cold and hot regions and recovery coefficient were calculated and compared using images of the NEMA phantom acquired with our scanner. The energy spectrum of coincidence events due to the small amount of (176)Lu in LYSO crystals, which was suitably included in our model, was also compared with experimental measurements. Spatial resolution, sensitivity and scatter fraction showed an agreement within 7%. Comparison of the count rates curves resulted satisfactory, being the values within the uncertainties, in the range of activities practically used in research scans. Analysis of the NEMA phantom images also showed a good agreement between simulated and acquired data, within 9% for all the tested parameters. This work shows that basic MC modeling of this kind of system is possible using GATE as a base platform; extension through suitably written customized code allows for an adequate level of accuracy in the results. Our careful validation against experimental data confirms that the developed simulation setup is a useful tool for a wide range of research applications.