Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 113301, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461450

RESUMO

In this work, the first proof of the principal of an in situ diagnostics of the heavy-ion beam intensity distribution in irradiation of solid targets is proposed. In this scheme, x-ray fluorescence that occurs in the interaction of heavy-ions with target atoms is used for imaging purposes. The x-ray conversion to optical radiation and a transport-system was developed, and its first test was performed in experiments at the Universal Linear Accelerator in Darmstadt, Germany. The Au-beam intensity distribution on thin foils and Cu-mesh targets was imaged using multiple x-ray pinholes (polychromatic imaging) and 2D monochromatic imaging of Cu Kα radiation by using a toroidally bent silicon crystal. The presented results are of importance for application in experiments on the investigation of the equation of states of high energy density matter using high intensity GeV/u heavy-ion beams of ≥1010 particles/100 ns.

2.
Bone Joint J ; 100-B(1): 42-49, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29305449

RESUMO

AIMS: The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint. PATIENTS AND METHODS: We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93) RESULTS: A total of 36 (10.5%) patients underwent revision surgery, giving a survival rate of 90.1% at three years (95% confidence intervals (CI) 86.1 to 93.1; number at risk: 155) and 85.0% at five years (95% CI 77.9 to 89.9; number at risk: 43). Dislocation of the mobile bearing occurred in 18 patients (5.6%) at three years (95% CI 1.0 to 16.4; number at risk: 154) and in 20 patients (8.5%) at five years (95% CI 1.0 to 27.0; number at risk: 42). There were no significant differences in the dislocation rate between the participating centres or the surgeons. We were not able to identify an effect of each surgeon's learning curve on the dislocation rate of the mobile bearing. The clinical outcome in patients without revision surgery at final follow-up was good to excellent, with a mean Oxford knee score of 40.3 (95% CI 39.4 to 41.2), a mean Tegner activity score of 3.2 (95% CI 3.1 to 3.3) and a mean University of California, Los Angeles score of 5.7 (95% CI 5.5 to 5.9). CONCLUSION: Our data, which consists of a high number of patients treated with mobile bearing UKA in the lateral compartment, indicates a high revision rate of 15% at five years with dislocation of the mobile bearing being the main reason for implant failure. Despite the good functional and clinical results and the high patient satisfaction in our study group, we therefore discontinued using mobile-bearing lateral UKA in favour of a fixed-bearing component. Cite this article: Bone Joint J 2018;100-B:42-9.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Feminino , Seguimentos , Humanos , Luxações Articulares/etiologia , Luxações Articulares/cirurgia , Estimativa de Kaplan-Meier , Articulação do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...