Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
Laryngorhinootologie ; 103(4): 252-260, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38565108

RESUMO

Language processing can be measured objectively using late components in the evoked brain potential. The most established component in this area of research is the N400 component, a negativity that peaks at about 400 ms after stimulus onset with a centro-parietal maximum. It reflects semantic processing. Its presence, as well as its temporal and quantitative expression, allows to conclude about the quality of processing. It is therefore suitable for measuring speech comprehension in special populations, such as cochlear implant (CI) users. The following is an overview of the use of the N400 component as a tool for studying language processes in CI users. We present studies with adult CI users, where the N400 reflects the quality of speech comprehension with the new hearing device and we present studies with children where the emergence of the N400 component reflects the acquisition of their very first vocabulary.


Assuntos
Implantes Cocleares , Percepção da Fala , Adulto , Criança , Feminino , Humanos , Masculino , Compreensão/fisiologia , Eletroencefalografia , Potenciais Evocados/fisiologia , Idioma , Desenvolvimento da Linguagem , Semântica , Percepção da Fala/fisiologia
2.
Sci Rep ; 14(1): 7046, 2024 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528064

RESUMO

One factor for the lacking integration of the middle ear stapes footplate prosthesis or the missing healing of stapes footplate fractures could be the known osteogenic inactivity. In contrast, it was recently demonstrated that titanium prostheses with an applied collagen matrix and immobilised growth factors stimulate osteoblastic activation and differentiation on the stapes footplate. Regarding those findings, the aim of this study was to evaluate the potential of bone regeneration including bone remodeling in the middle ear. Ten one-year-old female merino sheep underwent a middle ear surgery without implantation of middle ear prostheses or any other component for activating bone formation. Post-operatively, four fluorochromes (tetracycline, alizarin complexion, calcein green and xylenol orange) were administered by subcutaneous injection at different time points after surgery (1 day: tetracycline, 7 days: alizarin, 14 days: calcein, 28 days: xylenol). After 12 weeks, the temporal bones including the lateral skull base were extracted and histologically analyzed. Fluorescence microscopy analysis of the entire stapes with the oval niche, but in particular stapes footplate and the Crura stapedis revealed evidence of new bone formation. Calcein was detected in all and xylenol in 60% of the animals. In contrast, tetracycline and alizarin could only be verified in two animals. The authors were able to demonstrate the osseoregenerative potential of the middle ear, in particular of the stapes footplate, using fluorescence sequence labelling.


Assuntos
Antraquinonas , Fluoresceínas , Corantes Fluorescentes , Osteogênese , Xilenos , Ovinos , Feminino , Animais , Orelha Média/fisiologia , Tetraciclinas
3.
Cochlear Implants Int ; : 1-13, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532283

RESUMO

PURPOSE: This study evaluates the effect of cochlear implantation (CI) on work ability. The influences of quality of life (QOL), age, mental health, and hearing were analyzed. METHODS: Seventy-nine patients undergoing CI surgery were evaluated preoperatively and 12 months postoperatively. Work ability was evaluated using the Work Ability Index (WAI). QOL was assessed with the Nijmegen Cochlear Implant Questionnaire (NCIQ) and the WHOQOL-BREF. Mental health was assessed with the Patient Health Questionnaire. RESULTS: The WAI was unaffected by CI (Δ 0.8 ± 6.8, p = 0.42). No significant changes in WAI were observed for employees (Δ - 1.1 ± 5.7, p = 0.25) and pensioners (Δ -0.4 ± 7.8, p = 0.73). Patients without elevated depressiveness, stress, or somatoform symptoms had significantly better WAI.The multiple regression analyses show that WHOQOL-BREF (ß = 0.49, p ≤ 0.001), age (ß = -0.34, p ≤ 0.001), and depressiveness (ß = 0.33, p = 0.04) were significantly associated with WAI. In the employee group, the NCIQ (ß = 0.58, p = 0.008) had the strongest association with the WAI. CONCLUSION: Age, mental health, and QOL are predictive factors for work ability. This should be considered in the consultation and the rehabilitation process.

4.
Otol Neurotol ; 45(3): e256-e262, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38361307

RESUMO

OBJECTIVE: Tympanic membrane (TM) thickness is an important parameter for differentiation between a healthy and a pathologic TM. Furthermore, it is needed for modeling the middle ear function. Endoscopic optical coherence tomography (eOCT) provides the opportunity to measure the TM thickness of the entire TM in vivo. MATERIALS AND METHODS: A total of 27 healthy ears were examined by eOCT. The system uses a light source with a central wavelength of 1,300 nm. The endoscope with an outer diameter of 3.5 mm provides a field of view of 10 mm and a working distance of 10 mm. Thickness measurements were carried out at 8 points on the TM. Additionally, the existing literature was analyzed, and a mean TM thickness value was determined. RESULTS: The mean thickness of the TM over all measurement points of the pars tensa was 120.2 µm, and the pars flaccida was significantly thicker with a mean thickness of 177.9 µm. Beyond that, there were no significant differences between the single quadrants. The mean TM thickness in the literature was 88.8 µm. DISCUSSION: EOCT provides the possibility for in vivo thickness determination of the TM. The mean thickness seems to be higher than in the previous studies, which were mostly carried out ex vivo. Our study takes the three-dimensional refraction into account and provides a method for the refraction correction.


Assuntos
Tomografia de Coerência Óptica , Membrana Timpânica , Humanos , Membrana Timpânica/patologia , Tomografia de Coerência Óptica/métodos , Endoscópios
5.
HNO ; 72(Suppl 1): 33-42, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37792097

RESUMO

BACKGROUND: With the Chronic Ear Survey (CES), a validated measurement instrument for the assessment of disease-specific health-related quality of life (HRQoL) has been available internationally since 2000. The aim of this study was to provide a validated German version of this international instrument and to compare it with the German Chronic Otitis Media Outcome Test 15 (COMOT-15). METHODOLOGY: The CES was translated into German via a forward-backward translation process. For validation, 79 patients with COM undergoing middle ear surgery were prospectively included. HRQoL was determined preoperatively and 6 months postoperatively using the CES and the COMOT-15. Pure tone audiometry was also performed at both measurement time points. In the control examination, an additional retrospective assessment of the preoperative situation was additionally performed using the CES and the COMOT-15 to assess the response shift. The determined psychometric characteristics were internal consistency, test-retest reliability, discrimination validity, agreement validity, responsiveness, and response shift for both measurement instruments. Convergent validity of both measurement instruments was assessed using linear regression. RESULTS: On the basis of the CES, patients with COM could be reliably distinguished from patients with healthy ears. The CES showed satisfactory reliability with high internal consistency (Cronbach α 0.65-0.85) and high retest reliability (r > 0.8). The global assessment of HRQoL impairment correlated very well with the scores of the CES (r = 0.51). In addition, it showed a high sensitivity to change (standardized response mean -0.86). Compared to the COMOT-15, it showed a lower response shift (effect size -0.17 vs. 0.44). Both measurement instruments correlated only slightly with air conduction hearing threshold (r = 0.29 and r = 0.24, respectively). The concordant validity of both measurement instruments was high (r = 0.68). CONCLUSION: The German version of the CES shows satisfactory psychometric characteristics, so that its use can be recommended. The CES focuses on the influence of ear symptoms on HRQoL, whereas the COMOT-15 also includes functional and psychological aspects. Due to only minor response shift effects, the CES is particularly suitable for studies with multiple repeat measurements.


Assuntos
Otite Média , Qualidade de Vida , Humanos , Psicometria , Reprodutibilidade dos Testes , Estudos Retrospectivos , Inquéritos e Questionários , Idioma
6.
HNO ; 72(Suppl 1): 25-32, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37656221

RESUMO

BACKGROUND: Patients with a cochlear implant (CI) should be evaluated for a new speech processor every 6 years. The aim of this analysis was to assess the subjective and audiological benefit of upgrades. METHODS: Speech understanding and subjective benefit were analyzed in 99 patients with the old and the new speech processor after 4 weeks of wearing. Speech understanding was assessed using the Freiburg monosyllabic test in quiet (FBE) at 65 dB and 80 dB, and the Oldenburg Sentence Test (OLSA) at 65 dB noise with adaptive speech sound level. The Abbreviated Profile of Hearing Aid Benefit (APHAB) was used to assess subjective hearing impairment, and the Audio Processor Satisfaction Questionnaire (APSQ) was used to assess subjective satisfaction. RESULTS: The speech processor upgrade resulted in a significant improvement of speech understanding in quiet at 65 dB (mean difference 8.9 ± 25.9 percentage points, p < 0.001) and 80 dB (mean difference 8.1 ± 29.7 percentage points, p < 0.001) and in noise (mean difference 3.2 ± 10.7 dB signal-to-noise ratio [S/N], p = 0.006). Using the APHAB, a significant improvement (mean difference 0.07 ± 0.16, p < 0.001) in hearing impairment was demonstrated in all listening situations. The APSQ showed significantly higher patient satisfaction with the new speech processor (mean difference 0.42 ± 1.26, p = 0.006). A comparative assessment of the benefit based on subjective and speech audiometric results identified a proportion of patients (35-42%) who subjectively benefited from the upgrade but had no measurable benefit based on speech audiometry. CONCLUSION: There was a significant improvement in audiologically measurable and subjectively reflected speech understanding and patient satisfaction after the upgrade. In patients with only a small improvement in audiologically measurable speech understanding, the subjective benefit should also be assessed with validated measurement instruments in order to justify an upgrade to the payers in the health sector.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva , Percepção da Fala , Humanos , Fala , Implante Coclear/métodos , Perda Auditiva/diagnóstico , Perda Auditiva/cirurgia , Medidas de Resultados Relatados pelo Paciente
7.
Eur Arch Otorhinolaryngol ; 281(4): 1717-1734, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37917166

RESUMO

PURPOSE: This study aimed to determine whether preoperative depressiveness, stress, and personality influence quality of life (QOL) after cochlear implant (CI) surgery. METHODS: In this prospective study, 79 patients undergoing CI surgery were evaluated preoperatively and 12 months postoperatively. Disease-specific QOL was assessed with the Nijmegen Cochlear Implant Questionnaire (NCIQ) and general QOL with the WHOQOL-BREF. Depressiveness and stress were assessed with the Patient Health Questionnaire (PHQ-D). The Charlson Comorbidity Index (CCI) was used to classify comorbidities. The Big Five Personality Test (B5T) was used to assess the basic personality dimensions. Speech comprehension was evaluated in quiet with the Freiburg monosyllable test and in noise with the Oldenburg sentence test. RESULTS: After CI surgery, the total NCIQ score improved significantly (Δ 17.1 ± 14.7, p < 0.001). General QOL (WHOQOL-BREF, Δ 0.4 ± 9.9, p = 0.357), stress (Δ 0.25 ± 3.21, p = 0.486), and depressiveness (Δ 0.52 ± 3.21, p = 0.121) were unaffected by CI surgery. Patients without elevated depressiveness (p < 0.01) or stress (p < 0.001) had significantly better total NCIQ scores. The results of the multiple regression analyses show that, after adjusting for the CCI, personality, age, and mental health stress (ß = - 0.495, p < 0.001) was significantly associated with postoperative NCIQ outcome scores. Depressiveness and neuroticism had the strongest influence on the generic QOL (ß = - 0.286 and ß = - 0.277, p < 0.05). CONCLUSION: Stress symptoms and personality traits are significant predictive factors for disease-specific QOL, as well as hearing status. This should be considered in the preoperative consultation and in optimizing the rehabilitation process.


Assuntos
Implante Coclear , Implantes Cocleares , Transtorno Depressivo , Percepção da Fala , Humanos , Implante Coclear/métodos , Qualidade de Vida , Estudos Prospectivos , Personalidade , Inquéritos e Questionários
8.
Laryngorhinootologie ; 102(10): 777-791, 2023 10.
Artigo em Alemão | MEDLINE | ID: mdl-37793378

RESUMO

Chronic mesotympanal otitis media (CMOM) is a well-developed clinical presentation that is established in diagnostics and therapy. On closer inspection, however, this principle cannot be confirmed in all its facets. Already the physiology and pathophysiology of the middle ear mucosa leave questions unanswered, starting with the distribution of the ciliated epithelium in the middle ear and mastoid to the function of gas exchange.In addition, there are new diagnostic and therapeutic approaches. In the future, optical coherence tomography could help to determine the status of the middle ear mucosa. In addition, there are new findings on the effectiveness of local and systemic antibiotics as well as antiseptics in chronic otorrhea. Other new developments include minimally invasive surgical procedures using endoscopic techniques. All this gives reason to provide an update on the topic of chronic mesotympanal otitis media, which should contribute in preparation for the specialist examination or refreshing.Basics of physiology and pathophysiology as well as new diagnostic approaches and medical treatment were covered in Part 1 of this paper. In Part 2, in addition to established methods, new developments in surgical therapy with minimally invasive surgical procedures are described in more detail.


Assuntos
Otite Média , Humanos , Otite Média/diagnóstico , Otite Média/cirurgia , Otite Média/tratamento farmacológico , Orelha Média , Antibacterianos/uso terapêutico , Processo Mastoide , Doença Crônica
9.
Int J Audiol ; : 1-8, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37656611

RESUMO

OBJECTIVE: The goal of this study was to determine open field stapedius reflex thresholds (oSRTs) in CI patients with fittings based on subjective loudness ratings. A further objective was to compare these oSRTs and those of eSRT-based fittings that are similar to the oSRTs of normal hearing. DESIGN: Impedance measurements of the ear drum were taken while subjects were wearing their audio processors. The stapedius reflex was elicited by electrical stimulation transmitted through the activated CI system in response to an acoustic stimulus presented in the free sound field. STUDY SAMPLE: Subjects were 50 experienced CI users (n = 57 ears) with CI fittings based on subjective loudness scaling. RESULTS: A reference range for the oSRTs was defined that was identified in CI patients with eSRT-based fittings. Sound levels for stapedius reflex detection were inside the reference target range in 70% of the cases, below the reference range (i.e. down to 40 dB HL) in 20% of the cases, and above the reference range in 10% of the cases. CONCLUSION: Stapedius reflex detection in a free sound field may help detect fittings with too high or too low stimulation levels that might reduce audiological performance.

10.
HNO ; 71(9): 583-591, 2023 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-37540233

RESUMO

BACKGROUND: Patients with a cochlear implant (CI) should be evaluated for a new speech processor every 6 years. The aim of this analysis was to assess the subjective and audiological benefit of upgrades. METHODS: Speech understanding and subjective benefit were analyzed in 99 patients with the old and the new speech processor after 4 weeks of wearing. Speech understanding was assessed using the Freiburg monosyllabic test in quiet (FBE) at 65 dB and 80 dB, and the Oldenburg Sentence Test (OLSA) at 65 dB noise with adaptive speech sound level. The Abbreviated Profile of Hearing Aid Benefit (APHAB) was used to assess subjective hearing impairment, and the Audio Processor Satisfaction Questionnaire (APSQ) was used to assess subjective satisfaction. RESULTS: The speech processor upgrade resulted in a significant improvement of speech understanding in quiet at 65 dB (mean difference 8.9 ± 25.9 percentage points, p < 0.001) and 80 dB (mean difference 8.1 ± 29.7 percentage points, p < 0.001) and in noise (mean difference 3.2 ± 10.7 dB signal-to-noise ratio [S/N], p = 0.006). Using the APHAB, a significant improvement (mean difference 0.07 ± 0.16, p < 0.001) in hearing impairment was demonstrated in all listening situations. The APSQ showed significantly higher patient satisfaction with the new speech processor (mean difference 0.42 ± 1.26, p = 0.006). A comparative assessment of the benefit based on subjective and speech audiometric results identified a proportion of patients (35-42%) who subjectively benefited from the upgrade but had no measurable benefit based on speech audiometry. CONCLUSION: There was a significant improvement in audiologically measurable and subjectively reflected speech understanding and patient satisfaction after the upgrade. In patients with only a small improvement in audiologically measurable speech understanding, the subjective benefit should also be assessed with validated measurement instruments in order to justify an upgrade to the payers in the health sector.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva , Percepção da Fala , Humanos , Fala , Implante Coclear/métodos , Perda Auditiva/diagnóstico , Perda Auditiva/cirurgia , Medidas de Resultados Relatados pelo Paciente
11.
HNO ; 71(9): 572-582, 2023 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-37540235

RESUMO

BACKGROUND: With the Chronic Ear Survey (CES), a validated measurement instrument for the assessment of disease-specific health-related quality of life (HRQoL) has been available internationally since 2000. The aim of this study was to provide a validated German version of this international instrument and to compare it with the German Chronic Otitis Media Outcome Test 15 (COMOT-15). METHODOLOGY: The CES was translated into German via a forward-backward translation process. For validation, 79 patients with COM undergoing middle ear surgery were prospectively included. HRQoL was determined preoperatively and 6 months postoperatively using the CES and the COMOT-15. Pure tone audiometry was also performed at both measurement time points. In the control examination, an additional retrospective assessment of the preoperative situation was additionally performed using the CES and the COMOT-15 to assess the response shift. The determined psychometric characteristics were internal consistency, test-retest reliability, discrimination validity, agreement validity, responsiveness, and response shift for both measurement instruments. Convergent validity of both measurement instruments was assessed using linear regression. RESULTS: On the basis of the CES, patients with COM could be reliably distinguished from patients with healthy ears. The CES showed satisfactory reliability with high internal consistency (Cronbach α 0.65-0.85) and high retest reliability (r > 0.8). The global assessment of HRQoL impairment correlated very well with the scores of the CES (r = 0.51). In addition, it showed a high sensitivity to change (standardized response mean -0.86). Compared to the COMOT-15, it showed a lower response shift (effect size -0.17 vs. 0.44). Both measurement instruments correlated only slightly with air conduction hearing threshold (r = 0.29 and r = 0.24, respectively). The concordant validity of both measurement instruments was high (r = 0.68). CONCLUSION: The German version of the CES shows satisfactory psychometric characteristics, so that its use can be recommended. The CES focuses on the influence of ear symptoms on HRQoL, whereas the COMOT-15 also includes functional and psychological aspects. Due to only minor response shift effects, the CES is particularly suitable for studies with multiple repeat measurements.


Assuntos
Otite Média , Qualidade de Vida , Humanos , Psicometria , Reprodutibilidade dos Testes , Estudos Retrospectivos , Idioma , Inquéritos e Questionários
12.
Laryngorhinootologie ; 102(8): 619-628, 2023 08.
Artigo em Alemão | MEDLINE | ID: mdl-37536333

RESUMO

Chronic mesotympanal otitis media (CMOM) is a well-developed clinical presentation that is established in diagnostics and therapy. On closer inspection, however, this principle cannot be confirmed in all its facets. Already the physiology and pathophysiology of the middle ear mucosa leave questions unanswered, starting with the distribution of the ciliated epithelium in the middle ear and mastoid to the function of gas exchange.In addition, there are new diagnostic and therapeutic approaches. In the future, optical coherence tomography could help to determine the status of the middle ear mucosa. In addition, there are new findings on the effectiveness of local and systemic antibiotics as well as antiseptics in chronic otorrhea. Other new developments include minimally invasive surgical procedures using endoscopic techniques. All this gives reason to provide an update on the topic of chronic mesotympanal otitis media, which should contribute in preparation for the specialist examination or refreshing.Basics of physiology and pathophysiology as well as new diagnostic approaches and medical treatment were covered in Part 1 of this paper. In Part 2, in addition to established methods, new developments in surgical therapy with minimally invasive surgical procedures are described in more detail.


Assuntos
Otite Média , Humanos , Otite Média/diagnóstico , Otite Média/tratamento farmacológico , Otite Média/cirurgia , Orelha Média , Antibacterianos/uso terapêutico , Processo Mastoide , Doença Crônica
13.
Laryngorhinootologie ; 102(6): 412-415, 2023 06.
Artigo em Alemão | MEDLINE | ID: mdl-37267964

RESUMO

The 2018 template for otorhinolaryngology specialist training of the German Medical Association is increasingly implemented by the federal associations. In this regard, the German Society recommended an otorhinolaryngology resident training plan for Otorhinolaryngology, Head and Neck Surgery (DGHNO-KHC) together with the Professional Association of German Otorhinolaryngologists as a suggested guideline for the federal medical associations. In this context, the state medical associations currently work on criteria on the basis of which otorhinolaryngologists and their training institutions can be granted authority for such a certified otorhinolaryngology resident training program.The DGHNO-KHC last made recommendations for the granting of authorizations for specialist training in otorhinolaryngology in 1999. Many contents have changed as a result of the 2018 model specialist training regulations. Therefore, a scientifically formulated proposal for the granting of continuing education authorizations is herewith provided as recommendation to the federal state medical associations.


Assuntos
Otolaringologia , Humanos , Otolaringologia/educação , Especialização , Alemanha
14.
Eur Arch Otorhinolaryngol ; 280(11): 4835-4844, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37173536

RESUMO

PURPOSE: During COVID-19, a fully digital course was established for teaching and assessing the psychomotor skills of clinical head and neck examination. Influence of different digital teaching formats was investigated. METHODS: The students (n = 286) received disposable instruments, a manual, and instructional videos for the examination. 221 students additionally received 45 min of interactive teleteaching. After 5 days of practice, all students were required to submit a video of their examination and report their spent practice time. The assessment was carried out using a checklist which was already established in presence teaching. RESULTS: The average score achieved by digital teaching was 86%. Previously published data show that presence teaching achieved 94%. With a teleteaching unit the total score was significantly better than without (87% vs 83%). Teleteaching leads to a significant positive correlation between practice time and total score. Without teleteaching there is a negative correlation. After the same practice time, presence teaching leads to better total scores than digital teaching. CONCLUSION: Digital teaching and assessing of a complex psychomotor skill is possible. Interactive teaching methods increase learning success. Nevertheless, presence teaching seems to be better at teaching these skills. The results can provide a basis for developing hybrid teaching models.


Assuntos
COVID-19 , Pandemias , Humanos , Aprendizagem , Exame Físico , Ensino
15.
Hear Res ; 432: 108737, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37027992

RESUMO

INTRODUCTION: In reconstructive middle ear surgery, acoustic quality has received a high level of attention in recent years. Careful intraoperative selection and positioning of passive middle ear prostheses during tympanoplasty with ossiculoplasty is essential to ensure satisfactory sound transmission and postoperative hearing outcome. The reconstruction quality of the ossicular chain (OC) can be evaluated intraoperatively using a surgical assistance system which is based on a real-time monitoring system (RTM system) that acquires the transmission (middle ear transfer function (METF)) with electromagnetic excitation of the OC. In this experimental study, the METF with electromagnetic excitation of the (reconstructed) OC was compared to usual acoustic excitation and the benefit of the RTM system was investigated for the implantation of partial (PORP) and total (TORP) prostheses. METHODS: Laser Doppler vibrometry (LDV) was used to measure the middle ear transfer function (METF) in 18 human temporal bones (TB). The RTM system uses electromagnetic excitation of the OC with a magnet placed on the umbo. Comparatively, measurements with the usual acoustical excitation, using an earphone in the external auditory canal, were performed. The measurements began with the intact OC, followed by real-time monitoring guided OC reconstruction with PORP and TORP. In addition, during the simulation of an intraoperative setting, the influence of the influence of opening (tympanomeatal flap lifted and pushed anteriorly) and closing (tympanomeatal flap folded back) the tympanic membrane on the measurements with the RTM system was determined. RESULTS: Electromagnetic and acoustic excitation of the intact and the reconstructed OC provided comparable METF. The application of the RTM system significantly improved the quality of the OC reconstruction. The METF increased by up to 10 dB over the entire frequency range during implantation of the PORP with positioning control by the RTM system. When using the TORP, the METF could be improved by up to 15 dB. The opening of the tympanomeatal flap did not affect the measurements with the RTM system at the reconstructed OC. CONCLUSION: In this TB study, we demonstrated that the quality of OC reconstruction (improved METF as a benchmark for improved transmission) could be significantly increased by means of a RTM system. Intraoperative studies should now be conducted to investigate to which quantitative extent the intraoperative reconstruction quality can be improved and whether or not this improvement also manifests in an increased (long-term) hearing outcome. This will enable conclusions to be drawn about the contribution of the intraoperative reconstruction quality to the (long-term) hearing outcome in the context of the conglomerate of various factors influencing the postoperative hearing outcome.


Assuntos
Orelha Média , Prótese Ossicular , Implantação de Prótese , Humanos , Ossículos da Orelha/cirurgia , Orelha Média/cirurgia , Substituição Ossicular , Implantação de Prótese/métodos , Resultado do Tratamento , Timpanoplastia/métodos , Técnicas de Imagem por Elasticidade , Fenômenos Eletromagnéticos
16.
Ear Hear ; 44(1): 135-145, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35913925

RESUMO

OBJECTIVES: The active middle ear implant, Vibrant Soundbridge (VSB), can be implanted with a variety of couplers. Hearing outcome after implantation has been investigated in both temporal bone (TB) experiments and patient studies, but the relationship between experimental and clinical data is still weak in the literature. Therefore, experimental data from TB experiments should be compared with patient data in a retrospective study, in which the floating mass transducer is used with couplers of the third generation. Actuator coupling structures included the long (LP coupler) and short (SP coupler) incus process, the stapes head (Clip coupler), and the round window membrane (RW soft coupler). METHODS: In the TB experiments, the sound transmission after vibroplasty on the above-mentioned actuator coupling structures was determined in 32 specimens by means of laser Doppler vibrometry on the stapes footplate. Data of 69 patients were analyzed. The main target audiometric parameters were the postoperative aided word recognition score (WRS) in the free field at 65 dB SPL (WRS 65 dB in %), the preoperative and postoperative pure-tone average (PTA4, including the frequencies 0.5, 1, 2, and 4 kHz) of the bone conduction hearing threshold (PTA4BC), the aided postoperative air conduction hearing threshold in the free field (PTA4FF) and the direct threshold (Vibrogram) at least 6 months postoperatively. The coupling efficiency of the actuator (Vibrogram-PTA4BC) as well as the effective hearing gain (PTA4FF-PTA4BC) was compared between the couplers. RESULTS: The analysis in the main speech range (0.5-4 kHz) indicated that in the TB experiments, the LP coupler tends to have the best coupling quality at low frequencies (500-1000 Hz). This was up to 15 dB above the worst actuator (RW soft coupler). However, the results missed the significance level ( p > 0.05). In the high frequencies (2000-4000 Hz), the Clip coupler showed the best coupling quality. This was 15 dB above the worst actuator (SP coupler). However, the results missed the significance level ( p > 0.05), too. The postoperative WRS at 65 dB SPL and the postoperative PTA4FF were independent of the actuator coupling structure. The PTA4BC was stable at 6 months postoperatively. For the PTA4 of the coupling efficiency, there were no significant differences between the actuator coupling structures (LP 8.9 dB ± 12.9; SP 9.5 ± 6.5 dB; Clip 5.2 ± 10.5 dB; RW 12.7 ± 11.0 dB). However, the tendential inferiority of the RW soft coupler with regard to transmission in the low-frequency range and the tendential superiority of the Clip coupler in the high-frequency range that have already been displayed experimentally could be confirmed in the clinical results. However, the clinical results missed the significance level, too ( p > 0.05). CONCLUSIONS: In vivo, there are no significant differences in the postoperative outcome stratified according to coupling the target structure. The differences known from the experimental setting were repressed by individual biasing factors. However, to ensure sufficient postoperative speech intelligibility, the frequency-specific transmission behavior of the couplers should be taken into account when setting the indication for VSB implantation.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Humanos , Estudos Retrospectivos , Audição , Osso Temporal/cirurgia , Resultado do Tratamento
17.
J Clin Med ; 13(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38202190

RESUMO

BACKGROUND: the word recognition score (WRS) achieved with cochlear implants (CIs) varies widely. To account for this, a predictive model was developed based on patients' age and their pre-operative WRS. This retrospective study aimed to find out whether the insertion depth of the nucleus lateral-wall electrode arrays contributes to the deviation of the CI-achieved WRS from the predicted WRS. MATERIALS AND METHODS: patients with a pre-operative maximum WRS > 0 or a pure-tone audiogram ≥80 dB were included. The insertion depth was determined via digital volume tomography. RESULTS: fifty-three patients met the inclusion criteria. The median WRS achieved with the CI was 70%. The comparison of pre- and post-operative scores achieved with a hearing aid and a CI respectively in the aided condition showed a median improvement of 65 percentage points (pp). A total of 90% of the patients improved by at least 20 pp. The majority of patients reached or exceeded the prediction, with a median absolute error of 11 pp. No significant correlation was found between the deviation from the predicted WRS and the insertion depth. CONCLUSIONS: our data support a previously published model for the prediction of the WRS after cochlear implantation. For the lateral-wall electrode arrays evaluated, the insertion depth did not influence the WRS with a CI.

18.
Laryngorhinootologie ; 101(6): 518-538, 2022 06.
Artigo em Alemão | MEDLINE | ID: mdl-35724922

RESUMO

Vestibular (vestibulocochlear) schwannomas are rare, benign schwannomas of the cerebellopontine angle, the internal auditory canal, or the inner ear. They can occur with or without clinical symptoms. The most common symptoms are unilateral or side-differentiated hearing loss with or without tinnitus and balance disorders. Initial symptomatology is nonspecific in the basic functional diagnosis, raising the question of when a hearing or balance disorder should be thought of as a differential diagnosis of vestibular schwannoma and what diagnostic pathway is appropriate. This concerns not only the confirmation of the diagnosis and the recording of all dysfunctions of the involved cranial nerves in the initial basic diagnostics, but also the procedure in the course and follow-up diagnostics - especially in patients who are subject to an observation strategy. Today, imaging alone is no longer sufficient for differentiated and individualized patient counseling. Due to the increasing detection of smaller tumors on MRI and the growing proportion of nearly asymptomatic patients, a shift in thinking from pure imaging monitoring to a detailed analysis of auditory and vestibular function is timely. In this educational article, diagnostic pathways for a sufficient patient consultation will be compiled. Ultimately, functional examination techniques from follow-up and progression diagnostics will also be included.


Assuntos
Orelha Interna , Perda Auditiva , Neurilemoma , Neuroma Acústico , Zumbido , Humanos , Imageamento por Ressonância Magnética/métodos , Neurilemoma/patologia , Neuroma Acústico/diagnóstico , Neuroma Acústico/patologia , Zumbido/diagnóstico , Zumbido/etiologia
19.
Laryngorhinootologie ; 101(S 01): S3-S35, 2022 05.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-35605611

RESUMO

The provision of implantable hearing aids represents an area with high development and innovation potential. On the one hand, this review article provides an overview of current indication criteria for the treatment with active middle ear implants. On the other hand, outcome parameters as well as functional results after implantation of active middle ear implants are demonstrated and discussed. The focus is mainly placed on audiological results as well as the subjective health status. "Patient Reported Outcome Measures" (PROMs) have become an integral part of the evaluation of hearing implant treatment. Due to low evidence level criteria, the study situation regarding audiological as well as subjective outcome parameters is not satisfactory. The lack of an international consensus on accepted outcome parameters makes a meta-analytical analysis of results immensely difficult. In the studies published to date, patients with sensorineural hearing loss and patients with conductive or mixed hearing loss offered better speech recognition after implantation of an active middle ear implant compared to conventional hearing aids. Current analyses show a significant improvement in general as well as hearing-specific quality of life after implantation of an active middle ear implant. To date, no validated, hearing-specific quality-of-life measurement instruments exist for assessing the success of fitting in children. Especially in children with complex malformations of the outer ear and the middle ear, excellent audiological results were shown. However, these results need to be substantiated by quality-of-life measurements in future.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Neurossensorial , Prótese Ossicular , Percepção da Fala , Criança , Orelha Média/cirurgia , Humanos , Qualidade de Vida , Resultado do Tratamento
20.
Biomater Sci ; 10(9): 2287-2301, 2022 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-35363238

RESUMO

Most commonly, autologous grafts are used in tympanic membrane (TM) reconstruction. However, apart from the limited availability and the increased surgical risk, they cannot replicate the full functionality of the human TM properly. Hence, biomimetic synthetic TM implants have been developed in our project to overcome these drawbacks. These innovative TM implants are made from synthetic biopolymer polycaprolactone (PCL) and silk fibroin (SF) by electrospinning technology. Static and dynamic experiments have shown that the mechanical and oscillatory behavior of the TM implants can be tuned by adjusting the solution concentration, the SF and PCL mixing ratio and the electrospinning parameters. In addition, candidates for TM implants could have comparable acousto-mechanical properties to human TMs. Finally, these candidates were further validated in in vitro experiments by performing TM reconstruction in human cadaver temporal bones. The reconstructed TM with SF-PCL blend membranes fully recovered the acoustic vibration when the perforation was smaller than 50%. Furthermore, the handling, medium adhesion and transparency of the developed TM implants were similar to those of human TMs.


Assuntos
Fibroínas , Perfuração da Membrana Timpânica , Biomimética , Humanos , Miringoplastia , Membrana Timpânica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...