Biomater Investig Dent ; 10(1): 2268670, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38027422

RESUMO

To assess the influence of dentifrices with different abrasiveness levels on the properties of dental reconstructive materials. Forty-eight cylinders were obtained from four polymeric materials, being two CAD/CAM acrylic resins (Ivotion-Dent and Ivotion-Base), one injected acrylic resin (IvoBase-Hydrid) and one light-cured resin composite (Empress Direct). Specimens were allocated to four subgroups for toothbrushing simulation according to the dentifrice relative dentin abrasivity (RDA) and silica content: (i) RDA 0 = 0%; (ii) RDA 50 = 3%; (iii) RDA 100 = 10%; and (iv) RDA 120 = 25%. Specimens were then subjected to toothbrushing. Surface analyses [surface roughness Ra (SR) and scanning electron microscopy (SEM)] along with hardness and optical properties [translucency parameter (TP) and contrast ratio (CR)] were evaluated before and after toothbrushing. Statistical analyses were performed using ANOVA and Tukey test. A significant increase in SR was observed after toothbrushing with higher RDA toothpastes for Ivotion-Dent (100 and 120) and IvoBase-Hybrid (120). Ivotion-Base and Empress Direct presented no significant differences in SR when analyzed as a function of timepoint and RDA levels. Hardness was not influenced by toothbrushing with different RDA dentifrices, except for Empress Direct with RDA 0 toothpaste, where a decrease in the hardness was observed. TP of Ivotion-Dent and Empress Direct significantly decreased after toothbrushing with higher RDA dentifrices and CR of Ivotion-Dent, Empress Direct and IvoBase-Hybrid significantly increased with higher RDA dentifrices. The levels of dentifrice abrasiveness affected differently the SR, hardness and optical properties of polymeric reconstructive materials after toothbrushing.

2.
Dent J (Basel) ; 11(9)2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37754327

RESUMO

To assess the reliability and failure modes of Ti-base abutments supported by narrow and wide-diameter implant systems. Narrow (Ø3.5 × 10 mm) and wide (Ø5 × 10 mm) implant systems of two different manufacturers with internal conical connections (16°) and their respective Ti-base abutments (3.5 and 4.5 mm) were evaluated. Ti-base abutments were torqued to the implants, standardized metallic maxillary incisor crowns were cemented, and step stress accelerated life testing of eighteen assemblies per group was performed in three loading profiles: mild, moderate, and aggressive until fracture or suspension. Reliability for missions of 100,000 cycles at 100 and 150 N was calculated, and fractographic analysis was performed. For missions at 100 N for 100,000 cycles, both narrow and wide implant systems exhibited a high probability of survival (≥99%, CI: 94-100%) without significant differences. At 150 N, wide-diameter implants presented higher reliability (≥99%, CI: 99-100%) compared to narrow implants (86%, CI: 61-95%), with no significant differences among manufacturers. Failure mode predominantly involved Ti-base abutment fractures at the abutment platform. Ti-base abutments supported by narrow and wide implant systems presented high reliability for physiologic masticatory forces, whereas for high load-bearing applications, wide-diameter implants presented increased reliability. Failures were confined to abutment fractures.

3.
J Prosthet Dent ; 130(5): 739.e1-739.e8, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37684141

RESUMO

STATEMENT OF PROBLEM: The bonding of implant-supported prostheses is determined by abutment material, convergence angle, height, surface treatment, and luting agents. However, studies evaluating the bonding of luting agents to titanium base abutments with different heights under fatigue conditions are scarce. PURPOSE: The purpose of this in vitro study was to evaluate the retention of zirconia crowns bonded with different luting agents to titanium base abutments of different heights before and after fatigue testing. MATERIAL AND METHODS: Zirconia crowns were designed, milled, and distributed into 4 experimental groups according to the luting agents (G-Multi Primer/G-Cem LinkForce [MP/GC] and Scotchbond Universal/RelyX Ultimate [SU/RU]) and titanium base abutment heights (2.5 mm and 4 mm) (n=10). Pull-out testing was performed in a universal testing machine at a crosshead speed of 1 mm/min until crown displacement. Fatigue testing was performed by an electric precision fatigue simulator (1×106 cycles; 100 N; and 15 Hz), followed by pull-out testing of fatigued specimens. Collected data were statistically evaluated by using a linear mixed model after post hoc comparisons by the least significant difference test (α=.05). RESULTS: Luting agents, abutment heights, and fatigue influenced the bonding retention of zirconia crowns to titanium base abutments. SU/RU agents promoted higher pull-out compared with MP/GC for both abutment heights before and after fatigue. Higher abutment height increased pull-out regarding lower abutment height for SU/RU materials before and after fatigue testing. Although fatigue had no significant effect on the pull-out of MP/GC, lower bond retention was observed for SU/RU after fatigue, regardless of abutment height. CONCLUSIONS: Luting agent composition and the interaction with abutment height and fatigue influenced the retention of zirconia crowns to titanium base abutments.


Assuntos
Cimentos Dentários , Implantes Dentários , Cimentos Dentários/química , Titânio/química , Coroas , Zircônio/química , Teste de Materiais , Dente Suporte , Análise do Estresse Dentário
4.
J Mech Behav Biomed Mater ; 136: 105519, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36279744

RESUMO

PURPOSE: This study evaluated the probability of survival and failure mode of endodontically treated incisors without ferrule restored with CAD/CAM FRC post-cores. METHODS: Root canals of bovine incisors were treated, leaving post preparations of ∼10 mm. Teeth were allocated into three groups: (i) cast metal post-core, (ii) FRC prefabricated post with a direct resin core build-up, and (iii) CAD/CAM FRC post-core. Posts and zirconia crowns were cemented using resin cement. Specimens were subjected to step-stress accelerated-life fatigue testing in water. Use level probability Weibull curves, probability of survival for a mission of 100,000 cycles at 25, 50, and 100 N, Weibull modulus, and characteristic strength were calculated and plotted. Failure mode was examined under a stereomicroscope. RESULTS: Restored incisors demonstrated high probability of survival (93-100%) for missions estimated at 25 and 50 N, irrespective of post-core foundation. At 100 N, incisors restored with metal posts presented significantly higher probability of survival (99%) relative to CAD/CAM posts (79%), whereas FRC groups demonstrated no significant difference. Weibull analysis indicated no significant difference on the Weibull modulus (m = 3.38-5.92). Incisors reconstructed with metal post-cores (431 N) presented significantly higher characteristic strength relative to prefabricated (200 N) and CAD/CAM (202 N) FRC post-cores. While post fracture was the chief failure mode for prefabricated and CAD/CAM FRC post-cores, post and/or root fracture were the main event for metal post-cores. CONCLUSION: Endodontically treated incisors without ferrule restored with CAD/CAM FRC post-cores presented promising probability of survival for loads compatible with anterior masticatory forces and favorable failure modes.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Animais , Bovinos , Incisivo , Coroas , Desenho Assistido por Computador , Cimentos de Resina , Resinas Compostas , Análise do Estresse Dentário , Falha de Restauração Dentária
5.
Dent Mater ; 37(12): 1783-1793, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34588130

RESUMO

OBJECTIVE: To characterize the biomechanical performance of fiber-reinforced composite 5-unit implant-supported fixed dental prostheses (FDPs) receiving individually milled crowns by insilico and fatigue analyses. METHODS: Eighteen implant-supported five-unit fiber-reinforced composite frameworks with an individually prepared abutment design were fabricated, and ninety resin-matrix ceramic crowns were milled to fit each abutment. FDPs were subjected to step-stress accelerated-life testing with load delivered at the center of the pontic and at 2nd molar and 1st premolar until failure. The reliability of the prostheses combining all loaded data and of each loaded tooth was estimated for a mission of 50,000 cycles at 300, 600 and 900 N. Weibull parameters were calculated and plotted. Fractographic and finite element analysis were performed. RESULTS: Fatigue analysis demonstrated high probability of survival at 300 N, with no significant differences when the set load was increased to 600 and 900 N. 1st and 2nd molar dataset showed high reliability at 300 N, which remained high for the higher load missions; whereas 1st premolar dataset showed a significant decrease when the reliability at 300 N was compared to higher load missions. The characteristic-strength of the combined dataset was 1252 N, with 1st molar dataset presenting higher values relative to 2nd molar and 1st premolar, both significantly different. Failure modes comprised chiefly cohesive fracture within the crown material originated from cracks at the occlusal area, matching the maximum principal strain location. SIGNIFICANCE: Five-unit implant-supported FDP with crowns individually cemented in a fiber-reinforced composite framework presented a high survival probability. Crown fracture comprised the main failure mode.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Cerâmica , Coroas , Porcelana Dentária , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Humanos , Teste de Materiais , Reprodutibilidade dos Testes
6.
J Mech Behav Biomed Mater ; 124: 104832, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34536801

RESUMO

OBJECTIVE: Evaluate the effect of aging using two different methods on the three-dimensional fit of zirconia abutments at the implant-abutment connection and estimate the probability of survival of anterior crowns supported by straight and 17-degree angled abutments. MATERIALS AND METHODS: Two different zirconia abutment designs, straight and 17-degree angled abutments (n = 63/group), were evaluated in the current study. The abutments were randomly allocated into three experimental groups according to laboratory aging condition (134°C, 2.2 bar, 20 h): (i) control, (ii) autoclave aging, and (iii) hydrothermal reactor aging. Crystalline content was determined by X-Ray diffraction (XRD) and Raman spectroscopy, and microstructure was analyzed using field-emission gun scanning electron microscope (FEG-SEM). Implant-abutment volume misfit was determined in the straight abutments by micro-computed tomography using the silicone replica technique. For fatigue testing, abutments were torqued to the implants and connected to standardized maxillary incisor zirconia crowns. The assemblies were subjected to step-stress accelerated life testing (SSALT) in water until fracture or suspension. The use level probability Weibull curves and probability of survival for a mission of 50,000 cycles at 50, 100, 150 and 200 N were calculated and plotted. Fractured samples were analyzed using a stereomicroscope and scanning electron microscope. RESULTS: The crystalline spectra depicted a zirconia system primarily composed of the tetragonal phase. Laboratory aging yielded a 20%- and 37%-increase in the monoclinic content for abutments aged in autoclave and hydrothermal reactor relative to control, respectively. A fully crystalline matrix with a regular grain size was observed in the FEG-SEM for control abutments, with a considerable presence of intergranular defects. While autoclave aging triggered no significant alteration to the microstructure, defect population was reduced after hydrothermal reactor aging. Control abutments presented a significantly higher volume misfit (2.128 ± 0.54 mm3) relative to aged abutments using autoclave (1.244 ± 0.48 mm3) or hydrothermal reactor (1.441 ± 0.41 mm3). The beta (ß) values indicated that failures were predominantly controlled by material strength rather than fatigue damage accumulation for all groups, except for straight control abutments. Irrespective of aging, the probability of survival of straight and angled zirconia abutments was up to 95% (95-100%) at 50 and 100 N. A 50N-increase in the load resulted in wider range of survival estimate, with straight autoclave abutments percentage significantly lower probability of survival (77%) than angled hydrothermal reactor abutments (99%). At 200N, angled hydrothermal reactor (97%) or autoclave (82%) aged abutments demonstrated the highest probability of survival, angled control (71%) and straight hydrothermal reactor (69%) abutments intermediate values, and straight autoclave (23%) and control (7%) abutments the lowest estimate. The failure mode predominantly involved abutment and/or abutment screw fracture for both straight and angled abutments. CONCLUSIONS: Hydrothermal aging significantly influenced volume misfit, as well as the probability of survival of zirconia abutments at higher loads for both angled and straight abutments.


Assuntos
Próteses e Implantes , Zircônio , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Microtomografia por Raio-X
7.
Clin Implant Dent Relat Res ; 23(3): 317-328, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34047046

RESUMO

BACKGROUND: Osseodensification (OD) has shown to improve implant stability; however, the influences of implant design, dimensions, and surgical site characteristics are unknown. PURPOSE: To compare the insertion torque (IT) and temporal implant stability quotients (ISQ) of implants placed via OD or subtractive drilling (SD). MATERIALS AND METHODS: This multicenter controlled clinical trial enrolled 56 patients, whom were in need of at least 2 implants (n = 150 implants). Patients were treated with narrow, regular, or wide implants and short, regular, or long implants in the anterior or posterior region of the maxilla or in the posterior region of the mandible. Osteotomies were performed following manufacturers recommendation. IT was recorded with a torque indicator. ISQ was recorded with resonance frequency analysis immediately after surgery, 3 and 6 weeks. RESULTS: Data complied as a function of osteotomy indicated significantly higher IT for OD relative to SD. OD outperformed conventional SD for all pairwise comparisons of arches (maxilla and mandible) and areas operated (anterior and posterior), diameters and lengths of the implants, except for short implants. Overall, ISQ data also demonstrated significantly higher values for OD compared to SD regardless of the healing period. Relative to immediate readings, ISQ values significantly decreased at 3 weeks, returning to immediate levels at 6 weeks; however, ISQ values strictly remained above 68 throughout healing time for OD. Data as a function of arch operated and osteotomy, area operated and osteotomy, implant dimensions and osteotomy, also exhibited higher ISQ values for OD relative to SD on pairwise comparisons, except for short implants. CONCLUSIONS: OD demonstrated higher IT and temporal ISQ values relative to SD, irrespective of arch and area operated as well as implant design and dimension, with an exception for short implants. Future studies should focus on biomechanical parameters and bone level change evaluation after loading.


Assuntos
Implantes Dentários , Osseointegração , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Humanos , Mandíbula/cirurgia , Análise de Frequência de Ressonância , Torque
8.
Dent Mater ; 37(8): e443-e453, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33865619

RESUMO

OBJECTIVES: To characterize the physicochemical and mechanical properties of a milled fiber-reinforced composite (FRC) for implant-supported fixed dental prostheses (FDPs). METHODS: For FRC characterization, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction, Fourier-transformed infrared spectrometry, simultaneous thermogravimetric analysis and differential scanning calorimetry were performed. For fatigue testing, 3-unit FRC frameworks were fabricated with conventional (9 mm2 connector area) and modified designs (12 mm2 connector area and 2.5 mm-height lingual extension). A hybrid resin composite was veneered onto the frameworks. FDPs were subjected to step-stress accelerated-life fatigue testing until fracture or suspension. Use level probability Weibull curves at 300 N were plotted and the reliability for 100,000 cycles at 300, 600 and 800 N was calculated. Fractographic analysis was performed by stereomicroscope and SEM. RESULTS: The FRC consisted of an epoxy resin (∼25%) matrix reinforced with inorganic particles and glass fibers (∼75%). Multi-layer continuous regular-geometry fibers were densely arranged in a parallel and bidirectional fashion in the resin matrix. Fatigue analysis demonstrated high probability of survival (99%) for FDPs at 300 N, irrespective of framework design. Conventional FDPs showed a progressive decrease in the reliability at 600 (84%) and 800 N (19%), whereas modified FDPs reliability significantly reduced only at 800 N (75%). The chief failure modes for FRC FDPs were cohesive fracture of the veneering composite on lower loads and adhesive fracture of the veneering composite at higher loads. SIGNIFICANCE: Milled epoxy resin matrix reinforced with glass fibers composite resulted in high probability of survival in the implant-supported prosthesis scenario.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Resinas Compostas , Desenho Assistido por Computador , Materiais Dentários , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Reprodutibilidade dos Testes
9.
J Prosthodont Res ; 65(2): 171-175, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-32938879

RESUMO

PURPOSE: To evaluate the influence of resin cement type, surface pretreatment and autoclave sterilization on the retention of Y-TZP crowns to Ti-base abutments. METHODS: Y-TZP crowns were designed and milled to fit Ti-base abutments. Crowns were cemented using either a conventional resin cement (conventional) with a universal adhesive or a self-adhesive resin cement (self-adhesive), both following no surface pretreatment (No) or Ti-base abutment sandblasting (SB) (n=20/group). Half of the cemented samples were subjected to in-office autoclave sterilization. Pullout testing was performed in a universal testing machine at a speed of 1 mm/min until crown displacement. Data were statistically evaluated through a linear mixed model following post hoc comparisons by LSD test. RESULTS: Pullout data as a function of cement type demonstrated higher retention for conventional relative to self-adhesive cement (p < 0.001). Ti-base sandblasting (SB) favored crown retentiveness over No pretreatment (p < 0.001). Sterilized crowns exhibited higher pullout values than non-sterile (p=0.036). All the two- and three-factor interaction analyses corroborated with the superior adhesive strength of conventional compared to self-adhesive cement (all, p < 0.011), as well as, SB relative to No pretreatment (all, p < 0.024). While autoclave sterilization maximized bond strength when self-adhesive cement (data collapsed over surface pretreatment, p < 0.050) and No pretreatment were evaluated (data collapsed over surface pretreatment, p < 0.013), no significant difference was observed for conventional resin cement (p=0.280) and SB (p=0.878) groups. CONCLUSIONS: Conventional resin cement and/or Ti-base sandblasting increased Y-TZP crown retentiveness, with no significant influence of autoclave sterilization. Autoclaving increased retentiveness when self-adhesive cement and/or no Ti-base pretreatment were used.


Assuntos
Coroas , Titânio , Dente Suporte , Cimentos Dentários , Retenção em Prótese Dentária , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Esterilização , Propriedades de Superfície , Zircônio
10.
Biomed Res Int ; 2020: 1057846, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32964016

RESUMO

The reduced hardware design of narrow implants increases the risk of fracture not only of the implant itself but also of the prosthetic constituents. Hence, the current study is aimed at estimating the probability of survival of anterior crowns supported by different narrow implant systems. Three different narrow implant systems of internal conical connections were evaluated (Ø3.5 × 10 mm): (i) Active (Nobel Biocare), (ii) Epikut (S.I.N. Implant System), and (iii) BLX (Straumann). Abutments were torqued to the implants, and standardized maxillary incisor crowns were cemented. The assemblies were subjected to step-stress accelerated life testing (SSALT) in water through load application of 30 degrees off-axis lingually at the incisal edge of the crowns using a flat tungsten carbide indenter until fracture or suspension. The use level probability Weibull curves and reliability for completion of a mission of 100,000 cycles at 80 N and 120 N were calculated and plotted. Weibull modulus and characteristic strength were also calculated and plotted. Fractured samples were analyzed in a stereomicroscope. The beta (ß) values were 1.6 (0.9-3.1) and 1.4 (0.9-2.2) for BLX and Active implants, respectively, and 0.5 (0.3-0.8) for the Epikut implant, indicating that failures were mainly associated with fatigue damage accumulation in the formers, but more likely associated with material strength in the latter. All narrow implant systems showed high probability of survival (≥95%, CI: 85-100%) at 80 and 120 N, without significant difference between them. Weibull modulus ranged from 6 to 14. The characteristic strength of Active, Epikut, and BLX was 271 (260-282) N, 216 (205-228) N, and 275 (264-285) N, respectively. The failure mode predominantly involved abutment and/or abutment screw fracture, whereas no narrow implant was fractured. Therefore, all narrow implant systems exhibited a high probability of survival for anterior physiologic masticatory forces, and failures were restricted to abutment and abutment screw.


Assuntos
Projeto do Implante Dentário-Pivô/métodos , Coroas , Dente Suporte , Falha de Restauração Dentária , Análise do Estresse Dentário/métodos , Humanos , Incisivo/química , Teste de Materiais/métodos , Maxila/química , Microscopia Eletrônica de Varredura/métodos , Probabilidade , Próteses e Implantes , Reprodutibilidade dos Testes , Estresse Mecânico , Propriedades de Superfície , Torque , Água/química
11.
Int J Prosthodont ; 33(5): 527-535, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32956434

RESUMO

PURPOSE: To establish the most effective cementation protocol for bonding zirconia crowns to Ti-Base CAD/CAM abutments in terms of abutment height, cement type, and surface pretreatment. MATERIALS AND METHODS: Zirconia crowns were designed to fit abutments of 2.5-mm (short) and 4.0-mm (tall) height. The retention of conventional resin cement with a universal adhesive (RelyX Ultimate, 3M ESPE) was compared to self-adhesive resin cement (RelyX U200, 3M ESPE) following different surface pretreatments (n = 10/group): (1) no treatment (NT); (2) Ti-Base abutment surface blasting with alumina particles (SB); (3) zirconia crown tribochemical surface blasting with silica-coated alumina particles (TBS); and (4) a combination of SB + TBS. Pull-out testing was performed in a universal testing machine. Data were statistically evaluated using a linear mixed model following least significant difference post hoc test. RESULTS: Pull-out data as a function of Ti-Base height demonstrated higher retention for tall compared to short abutments (P < .001). Ultimate outperformed U200 cement (data collapsed over height and pretreatment) (P < .001). Analysis of pretreatment depicted higher retention for SB + TBS, followed by SB, TBS, and NT (P < .04). The interaction between Ti-Base height and cement type highlighted the superior adhesive strength of Ultimate compared to U200 for both heights (P < .001). Irrespective of type of pretreatment, surface pretreatment improved the retention for U200 cement and short Ti-Base (P < .03 compared to NT). In contrast, higher retention was demonstrated for SB + TBS, followed by SB, TBS, and NT, for Ultimate cement combined with tall Ti-Base (P < .02) (data collapsed over height and cement, respectively). CONCLUSION: There was a direct relationship among Ti-Base height, micromechanical and/or chemical pretreatment, and conventional adhesive bonding in improving the retention of zirconia crowns.


Assuntos
Cimentação , Titânio , Desenho Assistido por Computador , Coroas , Dente Suporte , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Zircônio
12.
J Long Term Eff Med Implants ; 29(2): 141-149, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32464023

RESUMO

We evaluate bone remodeling and prostheses survival of immediately provisionalized with occlusal loading and delayed loading (DL) single implants placed in the posterior region after 1-yr follow-up in dental practices. Included in the study are patients selected to receive one regular implant (4 × 10 mm) for single tooth replacement in healed ridge sockets in the mandible and maxilla. Implants are immediately loaded or delayed functionally loaded with metal ceramic crowns, depending on peak insertion torque value. All implants are clinically and radiographically evaluated at T1, immediately postoperatively; T2, 60 d; T3, 180 d; and T4, 360 d. Measurements between implant platform and top of alveolar bone crest at distal and mesial areas are performed using periapical radiographs. Data are statistically evaluated through two-way repeated measures of analysis of variance following post hoc comparisons using the Tukey test (p < 0.05). Ten specialists working in ten different practices treat 36 patients who receive one implant each with internal conical connection (hybrid implant system, 4 × 10 mm) (Emfils; Itu, Brazil). Results show that bone-level alterations in immediate (IM; 0.56 mm; confidence interval [CI]: ± 0.21 mm) and delayed (0.65 mm; CI: ± 0.19 mm) groups are not significantly different (p = 0.515) during the course of the 1-yr observation period. In both groups, statistically significant progressive bone-level remodeling occurs through the evaluated follow-up time points (p < 0.047). All prostheses are rated "alpha," presenting 100% success at 1-yr follow-up. The loading method does not influence bone-remodeling levels around IM or DL at the posterior region after 1-yr follow-up. No prostheses complications are reported.


Assuntos
Remodelação Óssea , Implantes Dentários para Um Único Dente , Carga Imediata em Implante Dentário , Adulto , Idoso , Coroas , Prótese Dentária Fixada por Implante , Feminino , Humanos , Estudos Longitudinais , Masculino , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Maxila/diagnóstico por imagem , Maxila/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Alvéolo Dental/cirurgia
13.
Clin Oral Implants Res ; 28(3): 320-326, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26916561

RESUMO

OBJECTIVE: To evaluate the effects of low- and rapid-resorption-rate bioabsorbable collagen membranes in maxillary sinus augmentation procedure in rabbits considering Schneiderian membrane (SM) reaction and bone tissue formation. MATERIALS AND METHODS: Eighteen male adult rabbits underwent bilateral maxillary sinus augmentation with particulate bovine hydroxyapatite to be divided into three groups, as follows: Group C - control, no membrane; Group RR - rapid resorbable collagen membrane; and Group SR - slow-resorbable collagen membrane. The animals were euthanized after 30 and 120 days for specimen's removal to be prepared and analyzed under light microscopy, histomorphometry, and immunohistochemistry for Runx2 and VEGF labeling. RESULTS: Histopathology evaluation presented similar healing pattern among the groups with a satisfactory response of SM, both at day 30 and day 120. Bone histomorphometry did not reveal significant differences among the groups, as well as immunohistochemistry analysis, which presented intense immunolabeling for both proteins in all groups. CONCLUSIONS: The presence of both membranes did not negatively interfere in bone formation and remodeling, and the focal mild inflammatory reaction caused by their degrading process did not impair the reconstructive procedure.


Assuntos
Substitutos Ósseos , Colágeno , Durapatita , Seio Maxilar/cirurgia , Osteogênese/fisiologia , Levantamento do Assoalho do Seio Maxilar/métodos , Implantes Absorvíveis , Animais , Remodelação Óssea/fisiologia , Bovinos , Masculino , Seio Maxilar/patologia , Modelos Animais , Mucosa Nasal , Coelhos
14.
J Biomed Opt ; 19(6): 066012, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24972360

RESUMO

In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC--splinted implants with a bar connected to two centrally placed O-rings, and BOD--splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.


Assuntos
Análise do Estresse Dentário/métodos , Maxila/patologia , Obturadores Palatinos , Prótese Dentária Fixada por Implante , Elasticidade , Humanos , Mastigação , Maxila/cirurgia , Modelos Dentários , Modelos Teóricos , Desenho de Prótese , Estresse Mecânico