Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Eur J Anaesthesiol ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38769936

RESUMO

BACKGROUND: Atelectasis has been reported in 68 to 100% of children undergoing general anaesthesia, a phenomenon that persists into the recovery period. Children receiving recruitment manoeuvres have less atelectasis and fewer episodes of oxygen desaturation during emergence. The optimal type of recruitment manoeuvre is unclear and may be influenced by the airway device chosen. OBJECTIVE: We aimed to investigate the different effects on lung mechanics as assessed by the forced oscillation technique (FOT) utilising different recruitment strategies: repeated inflations vs. one sustained inflation and different airway devices, a supraglottic airway device vs. a cuffed tracheal tube. DESIGN: Pragmatic enrolment with randomisation to the recruitment strategy. SETTING: We conducted this single-centre trial between February 2020 and March 2022. PARTICIPANTS: Seventy healthy patients (53 boys) aged between 2 and 16 years undergoing general anaesthesia were included. INTERVENTIONS: Forced oscillations (5 Hz) were superimposed on the ventilator waveform using a customised system connected to the anaesthesia machine. Pressure and flow were measured at the inlet of the airway device and used to compute respiratory system resistance and reactance. Measurements were taken before and after recruitment, and again at the end of surgery. MAIN OUTCOME MEASURES: The primary endpoint measured is the change in respiratory reactance. RESULTS: Statistical analysis (linear model with recruitment strategy and airway device as factors) did not show any significant difference in resistance and reactance between before and after recruitment. Baseline reactance was the strongest predictor for a change in reactance after recruitment: prerecruitment Xrs decreases by mean (standard error) of 0.25 (0.068) cmH2O s l-1 per  1 cmH2O-1 s l-1 increase in baseline Xrs (P < 0.001). After correcting for baseline reactance, the change in reactance after recruitment was significantly lower for sustained inflation compared with repeated inflation by mean (standard error) 0.25 (0.101) cmH2O (P = 0.0166). CONCLUSION: Although there was no significant difference between airway devices, this study demonstrated more effective recruitment via repeated inflations than sustained inflation in anaesthetised children. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry: ACTRN12619001434189.

2.
Eur J Pediatr ; 183(5): 2183-2192, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376594

RESUMO

We aimed to establish reference ranges for USCOM parameters in preterm infants, determine factors that affect cardiac output, and evaluate the measurement repeatability. This retro-prospective study was performed at Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy. We included infants below 32 weeks of gestational age (GA) and/or 1500 g of birth weight (BW). We excluded infants with congenital heart diseases or hemodynamic instability. Measurements were performed at 3 ± 1, 7 ± 2, and 14 ± 2 postnatal days. We analyzed 204 measurements from 92 patients (median GA = 30.57 weeks, BW = 1360 g). The mean (SD) cardiac output (CO) was 278 (55) ml/min/kg, cardiac index (CI) was 3.1 (0.5) L/min/m2, and systemic vascular resistance (SVRI) was 1292 (294) d*s*cm-5/m2. CO presented a negative correlation with postmenstrual age (PMA), while SVRI presented a positive correlation with PMA. The repeatability coefficient was 31 ml/kg/min (12%).  Conclusion: This is the first study describing reference values for USCOM parameters in hemodynamically stable preterm infants and factors affecting their variability. Further studies to investigate the usefulness of USCOM for the longitudinal assessment of patients at risk for cardiovascular instability or monitoring the response to therapies are warranted. What is Known: • The ultrasonic cardiac output monitoring (USCOM) has been widely used on adult and pediatric patients and reference ranges for cardiac output (CO) by USCOM have been established in term infants. What is New: • We established reference values for USCOM parameters in very preterm and very-low-birth-weight infants; the reference ranges for CO by USCOM in the study population were 198-405 ml/kg/min. • CO normalized by body weight presented a significant negative correlation with postmenstrual age (PMA); systemic vascular resistance index presented a significant positive correlation with PMA.


Assuntos
Débito Cardíaco , Recém-Nascido Prematuro , Humanos , Recém-Nascido , Débito Cardíaco/fisiologia , Masculino , Feminino , Valores de Referência , Estudos Prospectivos , Estudos Retrospectivos , Hemodinâmica/fisiologia , Reprodutibilidade dos Testes , Idade Gestacional , Monitorização Fisiológica/métodos , Resistência Vascular/fisiologia
3.
Pediatr Res ; 95(4): 1022-1027, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37857847

RESUMO

BACKGROUND: We investigated whether combining lung ultrasound scores (LUSs) and respiratory system reactance (Xrs) measured by respiratory oscillometry explains the severity of lung disease better than individual parameters alone. METHODS: We performed a prospective observational study in very preterm infants. Forced oscillations (10 Hz) were applied using a neonatal mechanical ventilator (Fabian HFOi, Vyaire). We used the simultaneous respiratory severity score (RSS = mean airway pressure × FIO2) as a primary outcome. We built linear mixed-effect models to assess the relationship between Xrs z-score, LUS and RSS and compared nested models using the likelihood ratio test (LRT). RESULTS: We enrolled 61 infants (median (Q1, Q3) gestational age = 30.00 (26.86, 31.00) weeks) and performed 243 measurements at a postnatal age of 26 (13, 41) days and postmenstrual age of 33.14 (30.46, 35.86) weeks. Xrs z-score and LUS were independently associated with simultaneous RSS (p < 0.001 for both). The model including Xrs and LUS explained the RSS significantly better than Xrs (p value LRT < 0.001) or LUS alone (p value LRT < 0.001). CONCLUSIONS: Combining LUS and Xrs z-score explains the severity of lung disease better than each parameter alone and has the potential to improve the understanding of the underlying pathophysiology. IMPACT: Combining respiratory system reactance by oscillometry and lung ultrasound score explains the respiratory support requirement (e.g., proxy of the severity of lung disease) significantly better than each parameter alone. We assessed the relationship between lung ultrasound and respiratory system reactance in very preterm infants for the first time. Combining respiratory oscillometry and lung ultrasound has the potential to improve the understanding of respiratory pathophysiology.


Assuntos
Doenças do Prematuro , Pneumopatias , Humanos , Recém-Nascido , Adulto , Recém-Nascido Prematuro , Pulmão/diagnóstico por imagem , Recém-Nascido de muito Baixo Peso , Pneumopatias/diagnóstico por imagem , Ultrassonografia
4.
Pediatr Res ; 94(6): 1998-2004, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37452113

RESUMO

BACKGROUND: The aim of this study was to describe the trajectory of oscillatory mechanics from the first week of life to term equivalent and evaluate whether oscillatory mechanics are associated with simultaneous lung disease in infants ≤32 weeks gestation. METHODS: In this observational, longitudinal study, we enrolled 66 infants. Forced oscillations were applied using a neonatal mechanical ventilator (Fabian HFOi) that superimposed oscillations (10 Hz, amplitude 2.5 cmH2O) on a positive end-expiratory pressure (PEEP). Measurements were performed at 5-7-9 cmH2O of PEEP or the clinical pressure ±2 cmH2O; they were repeated at 7, 14, 28 post-natal days, and 36 and 40 weeks post-menstrual age (PMA). RESULTS: The mean (range) gestational age of study participants was 29.2 (22.9-31.9) weeks. Nineteen infants (29%) developed bronchopulmonary dysplasia (BPD). Respiratory system reactance was significantly lower (lower compliance), and respiratory system resistance was significantly higher in infants with developing BPD from 7 post-natal days to 36 weeks PMA. All oscillatory mechanics parameters were significantly associated with the simultaneous respiratory severity score (p < 0.001 for all). CONCLUSIONS: Serial measurements of oscillatory mechanics allow differentiating lung function trajectory in infants with and without evolving BPD. Oscillatory mechanics significantly correlate with the severity of simultaneous lung disease. IMPACT: The results of the present study suggest that respiratory system reactance, as assessed by respiratory oscillometry, allows the longitudinal monitoring of the progression of lung disease in very premature infants. This paper describes for the first time the trajectory of oscillatory mechanics in very preterm infants with and without evolving bronchopulmonary dysplasia from the first week of life to term equivalent. Serial respiratory oscillometry measurements allow the identification of early markers of evolving bronchopulmonary dysplasia and may help personalizing the respiratory management strategy.


Assuntos
Displasia Broncopulmonar , Doenças do Prematuro , Lactente , Humanos , Recém-Nascido , Estudos de Coortes , Displasia Broncopulmonar/diagnóstico , Estudos Longitudinais , Recém-Nascido Prematuro
5.
Pediatr Pulmonol ; 58(9): 2442-2455, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37378417

RESUMO

Noninvasive respiratory support has gained significant popularity in neonatal units because of its potential to reduce lung injury associated with invasive mechanical ventilation. To minimize lung injury, clinicians aim to apply for noninvasive respiratory support as early as possible. However, the physiological background and the technology behind such support modes are not always clear, and many open questions remain regarding the indications of use and clinical outcomes. This narrative review discusses the currently available evidence for various noninvasive respiratory support modes applied in Neonatal Medicine in terms of physiological effects and indications. Reviewed modes include nasal continuous positive airway pressure, nasal high-flow therapy, noninvasive high-frequency oscillatory ventilation, nasal intermittent positive pressure ventilation (NIPPV), synchronized NIPPV and noninvasive neurally adjusted ventilatory assist. To enhance clinicians' awareness of each support mode's strengths and limitations, we summarize technical features related to the functioning mechanisms of devices and the physical properties of the interfaces commonly used for providing noninvasive respiratory support to neonates. We finally address areas of current controversy and suggest possible areas of research for implementing noninvasive respiratory support in neonatal intensive care units.


Assuntos
Lesão Pulmonar , Ventilação não Invasiva , Síndrome do Desconforto Respiratório do Recém-Nascido , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Respiração Artificial , Ventilação com Pressão Positiva Intermitente , Pressão Positiva Contínua nas Vias Aéreas , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
6.
Pediatr Nephrol ; 38(9): 3139-3144, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36988690

RESUMO

BACKGROUND: Preterm birth alters nephrogenesis and reduces the total nephron number. Intrauterine growth restriction (IUGR) seems to worsen nephron loss, but only a few studies have investigated its role in neonatal kidney impairment. We investigated whether IUGR, defined as reduced estimated fetal growth and/or placental flow alterations and low birth weight z-score, increases the risk of developing acute kidney injury (AKI) in very preterm infants. METHODS: We performed a retrospective study including infants born with a birth weight (BW) ≤ 1500 g and/or gestational age (GA) ≤ 32 weeks admitted to our center between January 2016 and December 2021. Neonatal AKI was defined according to the neonatal KDIGO classification based on the decline of urine output and/or creatinine elevation. We used multivariable linear regressions to verify the association between AKI and GA, BW z-score, IUGR definition, and hemodynamically significant patent ductus arteriosus (PDA). RESULTS: We included 282 infants in the analysis, with a median (IQR) GA = 29.4 (27.4, 31.3) weeks, BW = 1150 (870, 1360) g, and BW z-score = - 0.57 (- 1.64, 0.25). AKI was diagnosed in 36 (13%) patients, and 58 (21%) had PDA. AKI was significantly associated with BW z-score (beta (std. error) = - 0.08 (0.03), p = 0.008) and severe IUGR (beta (std. error) = 0.21 (0.08), p = 0.009), after adjusting for GA and PDA. CONCLUSIONS: Our data suggest that low BW z-score and IUGR could represent adjunctive risk factors for kidney impairment in preterm babies. A higher resolution version of the Graphical abstract is available as Supplementary information.


Assuntos
Injúria Renal Aguda , Nascimento Prematuro , Feminino , Humanos , Recém-Nascido , Gravidez , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/complicações , Peso ao Nascer , Permeabilidade do Canal Arterial/complicações , Retardo do Crescimento Fetal , Idade Gestacional , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Placenta , Estudos Retrospectivos
7.
Pediatr Pulmonol ; 58(5): 1454-1462, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36748837

RESUMO

BACKGROUND: Preterm infants have immature control of breathing and impaired pulmonary gas exchange. We hypothesized that infants with bronchopulmonary dysplasia (BPD) have a blunted ventilatory response and peripheral oxygen saturation (SpO2 ) instability during a hypoxic challenge. METHODS: We evaluated the response to hypoxia in 57 very preterm infants (38 no BPD, 10 mild BPD, 9 moderate-to-severe BPD) at 36 weeks' postmenstrual age. The fraction of inspired oxygen (FI O2 ) was reduced stepwise at 5-min intervals to achieve peripheral SpO2 between 86% and 95%. The lowest permissible FI O2 and SpO2 were 0.14% and 86%. We recorded SpO2 , FI O2 , and the respiratory signal (respiratory inductive plethysmography). We calculated respiratory rate (RR), tidal volume (VT ), minute ventilation (VE ), and respiratory drive (ratio between VT and inspiratory time, VT /TI ). SpO2 variability was expressed as the interquartile range (IQR). RESULTS: FI O2 was reduced from a median (Q1, Q3) of 0.21 (0.21, 0.21) to 0.17 (0.17, 0.18). We observed a marked individual variability in the ventilatory response to the hypoxic challenge, regardless of BPD severity. At the lowest permissible FI O2 , 37 (65%) infants reduced their VE , and 20 (35%) increased minute ventilation; 20 infants (35%) developed periodic breathing associated with increased SpO2 IQR and lower SpO2 minima, and 16 (28%) exhibited an oscillatory pattern in VE and SpO2 without end-expiratory pauses, regardless of BPD severity. CONCLUSION: In very preterm infants, a mild hypoxic challenge reduced ventilation, increased SpO2 variability and periodic breathing regardless of BPD severity.


Assuntos
Displasia Broncopulmonar , Doenças do Prematuro , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Saturação de Oxigênio , Pulmão , Hipóxia , Oxigênio
8.
Pediatr Pulmonol ; 58(3): 746-752, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36416349

RESUMO

OBJECTIVE: To create reference values for respiratory system resistance (Rrs) and reactance (Xrs) measured by the forced oscillation technique (FOT) in nonintubated very preterm infants. DESIGN: Retrospective analysis of data collected as part of prospective observational studies in two centers. SETTING: Tertiary neonatal intensive care units. PATIENTS: Non-intubated infants below 32 weeks' gestation age who did not develop bronchopulmonary dysplasia. INTERVENTIONS: We applied FOT using a mechanical ventilator (Fabian HFOi; Vyaire) that superimposed small-amplitude oscillations (10 Hz) on a continuous positive airway pressure of 3 and 5 cmH2 O. Measurements were performed during regular tidal breathing using a face mask. MAIN OUTCOME MEASURES: We analyzed 198 measurements performed between 7 postnatal days and 40 weeks postmenstrual age (PMA) in 85 infants, with a median (Q1, Q3) gestational age of 30.43 (29.14, 31.18) weeks. Logarithmic transformations were applied to Rrs and Xrs, and the relationship between transformed impedance values and demographic factors was examined by backwards stepwise linear regression. RESULTS: In univariable analysis, transformed Xrs was significantly associated with PMA, postnatal age, weight, and length, while Rrs was not. The best multivariable regression model estimating transformed Xrs (cmH2 O*s/L) at continuous positive airway pressure (CPAP) = 5 cmH2 O was: Ln(50 - Xrs) = 4.536 - 0.009 x PMA - 0.014 x weight z-score. SEE = 0.053, R2 = 0.36. The mean (SD) Rrs at CPAP = 5 cmH2 O was 33.63 (5.28) cmH2 O*s/L. CONCLUSION: We have established reference values for Rrs and Xrs at 10 Hz in nonintubated preterm neonates on continuous positive airway pressure support.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Doenças do Prematuro , Lactente , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Valores de Referência , Estudos Retrospectivos , Testes de Função Respiratória , Resistência das Vias Respiratórias
9.
Pediatr Pulmonol ; 58(3): 643-652, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36484311

RESUMO

Approximately 46% of the 5.2 million annual under-5 deaths derive from neonatal conditions commonly associated with hypoxemia or acute respiratory distress. It has been estimated that 98% of these deaths occur in low- and middle-income countries (LMICs). Effective implementation of noninvasive respiratory support at all levels of healthcare could significantly reduce neonatal mortality. Several factors limit the widespread and effective implementation of noninvasive respiratory support in LMICs, including inadequate infrastructure, lack of proper instrumentation, shortage of skilled staff, costly disposables, and difficulties in the supply of consumables and spare parts. The aim of this state-of-the-art paper is to provide a detailed evaluation of the commercially available devices providing noninvasive respiratory support in LMICs, focusing on bubblecontinuous positive airway pressure (bCPAP). bCPAP might be administrated using a variety of different commercial devices, including devices specifically designed for LMICs, as well as using self-made systems. We described all the equipment required for safe and effective implementation of bCPAP, including air and oxygen sourced, pressure-reducing valves and flowmeters, air-oxygen blending systems, humidifiers, respiratory support devices, patient circuits, and airway interfaces. Specifically, we critically evaluated the advantages and disadvantages of various existing solutions within the context of low-resource settings.


Assuntos
Síndrome do Desconforto Respiratório do Recém-Nascido , Síndrome do Desconforto Respiratório , Recém-Nascido , Lactente , Humanos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Países em Desenvolvimento , Pressão Positiva Contínua nas Vias Aéreas , Oxigênio
10.
Pediatr Res ; 93(4): 1010-1016, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35896704

RESUMO

BACKGROUND: The role of left ventricular (LV) diastolic pressure in the pathophysiology of bronchopulmonary dysplasia (BPD) is unclear. We evaluated the trajectory of echocardiographic parameters of LV diastolic function and the association with respiratory outcomes in preterm infants. METHODS: We retrospectively analysed measurements of LV diastolic function (E, e', A, Ee' and E/A ratios) in infants below 32 weeks' gestation (GA). We compared infants with and without BPD by two-way RM ANOVA. We considered Ee' ratio as a proxy of LV filling pressure and identified a cut-off value using ROC analysis. We divided infants using such threshold and compared respiratory outcomes between groups by Mann-Whitney or Chi-square tests. RESULTS: We included 72 infants. Ee' ratio at 28 days was significantly associated with the duration of respiratory support (beta (std. error) = 5.32 (1.82), p = 0.005) and BPD (beta = 0.27 (0.10), p = 0.008). Infants with Ee' ratio > 12 at 28 days had longer respiratory support, oxygen requirement, and higher BPD rates than infants with Ee' ratio ≤ 12. CONCLUSION: LV diastolic function associated with elevated LV filling pressure may contribute to the pathophysiology of BPD. Serial echocardiographic measurements could identify infants at risk of worse respiratory outcomes. IMPACT: In very preterm infants, we assessed the trajectory of left ventricular diastolic function by serial echocardiographic evaluations and evaluated its association with respiratory outcomes. On average, infants who developed bronchopulmonary dysplasia had higher Ee' at 28 postnatal days and 36 weeks postmentrual age than infants who did not develop the disease. Infants with elevated Ee' at 28 postnatal days, suggestive of elevated left atrial pressure, required longer respiratory support.


Assuntos
Displasia Broncopulmonar , Recém-Nascido Prematuro , Lactente , Humanos , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Estudos Retrospectivos , Displasia Broncopulmonar/complicações , Idade Gestacional , Função Ventricular Esquerda/fisiologia
11.
J Pediatr ; 251: 149-155, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35944717

RESUMO

OBJECTIVES: To identify short-term repeatability of forced oscillation technique (FOT) measurement of lung function, assess the lung function response to bronchodilators (BDs) by FOT, and prove the concept that only some very preterm infants manifest a change in lung mechanics in response to BD. STUDY DESIGN: We retrospectively analyzed respiratory system resistance and respiratory system reactance measured by FOT (Fabian HFOi). The measurement short-term repeatability was assessed in 43 patients on 60 occasions; BD responsiveness was assessed using a different data set, including 38 measurements in 18 infants. The coefficient of repeatability was calculated as twice the SD of differences between measurements performed 15 minutes apart. We assessed BD responsiveness by measuring respiratory system resistance and respiratory system reactance before and 15 minutes after administering 200 mcg/kg of nebulized salbutamol. A positive response was defined as an improvement in respiratory system resistance or respiratory system reactance greater than the identified coefficient of repeatability. RESULTS: The coefficient of repeatability was 7.5 cmH2O∗s/L (21%) for respiratory system resistance and 6.3 cmH2O∗s/L (21%) for respiratory system reactance. On average, respiratory system resistance did not change significantly following BD administration, though respiratory system reactance increased significantly (from -32.0 [-50.2, -24.4] to -27.9 [-38.1, -22.0] cmH2O∗s/L, P < .001). Changes in respiratory system resistance or respiratory system reactance after BD were greater than the identified coefficient of repeatability in 8 infants (44%) on 13 (34%) occasions. CONCLUSIONS: We identified a threshold to assess BD responsiveness by FOT in preterm infants. We speculate that FOT could be used to assess and personalize treatment with BD.


Assuntos
Resistência das Vias Respiratórias , Broncodilatadores , Lactente , Humanos , Recém-Nascido , Broncodilatadores/uso terapêutico , Estudos Retrospectivos , Resistência das Vias Respiratórias/fisiologia , Recém-Nascido Prematuro , Testes de Função Respiratória/métodos , Mecânica Respiratória
12.
Diagnostics (Basel) ; 12(4)2022 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-35453824

RESUMO

Background: Non-invasive, bedside diagnostic tools are extremely important for tailo ring the management of respiratory failure patients. The use of electronic noses (ENs) for exhaled breath analysis has the potential to provide useful information for phenotyping different respiratory disorders and improving diagnosis, but their application in respiratory failure patients remains a challenge. We developed a novel measurement apparatus for analysing exhaled breath in such patients. Methods: The breath sampling apparatus uses hospital medical air and oxygen pipeline systems to control the fraction of inspired oxygen and prevent contamination of exhaled gas from ambient Volatile Organic Compounds (VOCs) It is designed to minimise the dead space and respiratory load imposed on patients. Breath odour fingerprints were assessed using a commercial EN with custom MOX sensors. We carried out a feasibility study on 33 SARS-CoV-2 patients (25 with respiratory failure and 8 asymptomatic) and 22 controls to gather data on tolerability and for a preliminary assessment of sensitivity and specificity. The most significant features for the discrimination between breath-odour fingerprints from respiratory failure patients and controls were identified using the Boruta algorithm and then implemented in the development of a support vector machine (SVM) classification model. Results: The novel sampling system was well-tolerated by all patients. The SVM differentiated between respiratory failure patients and controls with an accuracy of 0.81 (area under the ROC curve) and a sensitivity and specificity of 0.920 and 0.682, respectively. The selected features were significantly different in SARS-CoV-2 patients with respiratory failure versus controls and asymptomatic SARS-CoV-2 patients (p < 0.001 and 0.046, respectively). Conclusions: the developed system is suitable for the collection of exhaled breath samples from respiratory failure patients. Our preliminary results suggest that breath-odour fingerprints may be sensitive markers of lung disease severity and aetiology.

13.
IEEE J Transl Eng Health Med ; 10: 4900708, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35415022

RESUMO

OBJECTIVE: Monitoring infants' breathing activity is crucial in research and clinical applications but remains a challenge. This study aims to develop a contactless method to monitor breathing patterns and thoracoabdominal asynchronies in infants inside the incubator, using depth cameras. METHODS: We proposed an algorithm to extract the 3D displacements of the ribcage and abdomen from the analysis of depth images. We evaluated the accuracy of the system in-vitro vs. a reference motion capture analyzer. We also conducted a feasibility study on 12 patients receiving non-invasive respiratory support to estimate the mean and the variability of the chest wall displacements in preterm infants and evaluate the suitability of the proposed system in the clinical setting. RESULTS: In-vitro, the mean (95% CI) error in the measurement of amplitude, frequency and phase shift between compartmental displacements was -0.14 (-0.57, 0.28) mm, 0.02 (-0.99, 1.03) bpm, and -0.40 (-1.76, 0.95)°, respectively. In-vivo, the mean (95% CI) amplitude of the ribcage and abdomen displacements were 0.99 (0.34, 2.67) mm and 1.20 (0.40, 2.15) mm, respectively. CONCLUSIONS: The developed system proved accurate in-vitro and was suitable for the clinical environment. CLINICAL IMPACT: The proposed method has value for evaluating infants' breathing patterns in research applications and, after further development, may represent a simple monitoring tool for infants' respiratory activity inside the incubator.


Assuntos
Recém-Nascido Prematuro , Parede Torácica , Estudos de Viabilidade , Humanos , Lactente , Recém-Nascido , Respiração , Taxa Respiratória
15.
Pediatr Pulmonol ; 57(4): 1092-1095, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34970872

RESUMO

Inhaled bronchodilators are often given in preterm infants with evolving or established bronchopulmonary dysplasia. However, it is unclear which patients may benefit from it and when it is the best time to start treatment. The forced oscillation technique (FOT) is a noninvasive method for assessing lung mechanics that proved sensitive to airway obstruction reversibility in children and adults. FOT does not need patient cooperation, which is ideal for infants. Bedside tools for applying FOT in infants during spontaneous breathing and different respiratory support modes are becoming available. This case report illustrates for the first time that FOT has potential value in assessing airway obstruction reversibility in preterm infants, informing which infants may manifest a clinical benefit from the treatment with bronchodilators.


Assuntos
Obstrução das Vias Respiratórias , Displasia Broncopulmonar , Adulto , Obstrução das Vias Respiratórias/tratamento farmacológico , Broncodilatadores/uso terapêutico , Displasia Broncopulmonar/complicações , Displasia Broncopulmonar/tratamento farmacológico , Criança , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Testes de Função Respiratória/métodos
16.
J Pediatr ; 241: 97-102.e2, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34687691

RESUMO

OBJECTIVES: To assess the feasibility of volumetric capnography in spontaneously breathing very preterm infants at 36 weeks postmenstrual age (PMA) and its association with clinical markers of lung disease including the duration of respiratory support and bronchopulmonary dysplasia (BPD). STUDY DESIGN: We obtained mainstream volumetric capnography measurements in 143 very preterm infants at 36 weeks PMA. BPD was categorized into no, mild, moderate, and severe according to the 2001 National Heart, Lung and Blood Institute workshop report. Normalized capnographic slopes of phase II (SnII) and phase III (SnIII) were calculated. We assessed the effect of BPD, duration of respiratory support, and duration of supplemental oxygen on capnographic slopes. RESULTS: SnIII was steeper in infants with moderate to severe BPD (76 ± 25/L) compared with mild (31 ± 20/L) or no BPD (26 ± 18/L) (P < .001). The association of SnIII with moderate to severe BPD persisted after adjusting for birth weight z-score, respiratory rate, and airway dead space to tidal volume ratio. The diagnostic usefulness of SnIII to discriminate between infants with and without moderate to severe BPD was high (area under the curve, 0.94; 95% CI, 0.89-0.99). CONCLUSIONS: Volumetric capnography is feasible in spontaneously breathing preterm infants at 36 weeks PMA and reflects the degree of lung disease. This promising bedside lung function technique may offer an objective, continuous physiological outcome measure for assessment of BPD severity. TRIAL REGISTRATION: ClinicalTrials.gov: NCT02083562.


Assuntos
Displasia Broncopulmonar/terapia , Capnografia , Recém-Nascido Prematuro , Respiração Artificial , Índice de Gravidade de Doença , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos
17.
Pediatr Pulmonol ; 56(8): 2561-2569, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34002956

RESUMO

We aimed at evaluating pressure transmission and stability during non-synchronized neonatal nasal intermittent positive pressure ventilation (NIPPV) delivered using five mechanical ventilators and three nasal interfaces. An artificial nose-throat model was connected to a mechanical analog of the infant respiratory system and a breath generator. Ventilation was administrated via a nasal mask (NM), short bi-nasal prongs (SBN), or RAM® cannula. We applied positive end-expiratory pressures (PEEP) of 5 and 10 cmH2 O, inspiratory pressures (PIP) of 15 and 30 cmH2 O, inspiratory times of 0.23, 0.42, and 0.57 s. Measurements were performed with leaks of 0, 1.5, and 4 L/min. The pressure was measured at the airways opening (PAW ) and the glottis (PGL ). The difference between set and delivered pressures (PAW ) was less than ±1 cmH2 O for all ventilators. We documented a significant difference between PAW and PGL in the presence of leaks. With 4 L/min leaks, PEEP dropped by 43%, 49%, and 63% with NM, SBP, and RAM® cannula, respectively; PIP dropped by 58%, 64%, and 74%. On average, the SD of PEEP fluctuations was ±0.60 and ±2.50 cmH2 O for PAW and PGL ; the breath-by-breath SD of PIP was ±0.77 and ±2.06 cmH2 O. During NIPPV, the PIP and PEEP transmission to the glottis is markedly lower than the set values and highly variable. The impact of leaks and nasal interface is much more significant than the differences in ventilators' performance on the efficacy of pressure transmission and stability of non-synchronized ventilator-generated NIPPV.


Assuntos
Ventilação com Pressão Positiva Intermitente , Ventiladores Mecânicos , Humanos , Recém-Nascido , Pulmão , Nariz , Respiração com Pressão Positiva
19.
J Pediatr ; 230: 112-118.e4, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33253731

RESUMO

OBJECTIVES: To investigate, in infants born preterm with or without bronchopulmonary dysplasia (BPD), the trajectory of tidal breathing flow-volume (TBFV) parameters in the first 2 years of life; the association between TBFV parameters and perinatal risk factors; and the predictive value of TBFV parameters for rehospitalizations due to respiratory infections and wheeze. STUDY DESIGN: We retrospectively analyzed TBFV measurements performed at 0-6, 6-12, and 12-24 months of corrected age in 97 infants <32 weeks of gestation and <1500 g. We assessed the association between TBFV parameters and perinatal risk-factors using linear regressions and the predictive capacity for subsequent respiratory morbidity using logistic regressions. We used the area under the curve and likelihood ratio test (LRT) to compare nested models. RESULTS: Time to peak tidal expiratory flow/expiratory time ratio (tPTEF/tE) was lower than normal for the first 2 years of corrected age. Longer duration of oxygen supplementation, intubation, and respiratory support were associated with reduced tPTEF/tE at all time points. For each z-score increase in tPTEF/tE, the OR for rehospitalizations decreased by 0.70. tPTEF/tE added significantly to BPD classifications alone in predicting rehospitalizations (area under the receiver operating characteristic curve = 0.81 vs 0.76, P value for LRT = .0012), and wheeze (area under the receiver operating characteristic curve = 0.76 vs 0.71, P value for LRT <.001). CONCLUSIONS: Infants born preterm, with and without BPD, display persistent airway obstruction during the first 2 years of life. tPTEF/tE may identify infants at greater risk of severe respiratory morbidity.


Assuntos
Displasia Broncopulmonar/fisiopatologia , Feminino , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Estudos Longitudinais , Masculino , Respiração , Estudos Retrospectivos , Volume de Ventilação Pulmonar/fisiologia
20.
Respir Res ; 21(1): 301, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-33208164

RESUMO

BACKGROUND: Tidal expiratory flow limitation (EFLT) promotes intrinsic PEEP (PEEPi) in patients with chronic obstructive pulmonary disease (COPD). Applying non-invasive ventilation (NIV) with an expiratory positive airway pressure (EPAP) matching PEEPi improves gas exchange, reduces work of breathing and ineffective efforts. We aimed to evaluate the effects of a novel NIV mode that continuously adjusts EPAP to the minimum level that abolishes EFLT. METHODS: This prospective, cross-over, open-label study randomized patients to one night of fixed-EPAP and one night of EFLT-abolishing-EPAP. The primary outcome was transcutaneous carbon dioxide pressure (PtcCO2). Secondary outcomes were: peripheral oxygen saturation (SpO2), frequency of ineffective efforts, breathing patterns and oscillatory mechanics. RESULTS: We screened 36 patients and included 12 in the analysis (age 72 ± 8 years, FEV1 38 ± 14%Pred). The median EPAP did not differ between the EFLT-abolishing-EPAP and the fixed-EPAP night (median (IQR) = 7.0 (6.0, 8.8) cmH2O during night vs 7.5 (6.5, 10.5) cmH2O, p = 0.365). We found no differences in mean PtcCO2 (44.9 (41.6, 57.2) mmHg vs 54.5 (51.1, 59.0), p = 0.365), the percentage of night time with PtcCO2 > 45 mm Hg was lower (62(8,100)% vs 98(94,100)%, p = 0.031) and ineffective efforts were fewer (126(93,205) vs 261(205,351) events/hour, p = 0.003) during the EFLT-abolishing-EPAP than during the fixed-EPAP night. We found no differences in oxygen saturation and lung mechanics between nights. CONCLUSION: An adaptive ventilation mode targeted to abolish EFLT has the potential to reduce hypercapnia and ineffective efforts in stable COPD patients receiving nocturnal NIV. TRIAL REGISTRATION: ClicalTrials.gov, NCT04497090. Registered 29 July 2020-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04497090 .


Assuntos
Expiração/fisiologia , Hipercapnia/terapia , Ventilação não Invasiva/métodos , Respiração com Pressão Positiva/métodos , Doença Pulmonar Obstrutiva Crônica/terapia , Volume de Ventilação Pulmonar/fisiologia , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Estudos Cross-Over , Feminino , Humanos , Hipercapnia/complicações , Hipercapnia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Polissonografia/métodos , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Troca Gasosa Pulmonar/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...