Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
World Neurosurg ; 185: e1074-e1085, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38490446

RESUMO

BACKGROUND: Chiari malformation is characterized by inferior displacement of the cerebellar tonsils through the foramen magnum, frequently resulting in strain related headaches, and motor/sensory dysfunction. Chiari decompression technique varies significantly, possibly contributing to frequent revisions. We reviewed revision Chiari decompressions at our institution to determine the primary indications for revision and outcomes after revision. METHODS: We retrospectively reviewed patients who underwent revision of Chiari decompression at our institution from 2005 to 2020. Demographics, indications for revision surgery, operative techniques, imaging findings, and preoperative/postoperative symptoms were collected. χ2 test was performed to determine statistical significance using a P < 0.05. Independent predictors of operative outcomes were identified. RESULTS: A total of 46 patients (91% females, mean age 38.8 years) were included for analysis. The median time to revision surgery was 69.1 months (range 0-364 months) with headache (n = 37, 80%) being the most commonly recurring symptom. Large craniectomy (n = 28, 61%) was the most frequent indication for revision surgery. Thirty-two (70%) patients underwent cranioplasty, 20 (43%) required duraplasty, 15 (33%) required arachnoid dissection, and 15 (33%) required tonsillar reduction during revision surgery. Postrevision follow-up (at 8.9 ± 5.2 months average, range 1-18 months), revealed an average reduction in all Chiari-related symptoms relative to symptoms before the revision. CONCLUSIONS: The most common indication for revision Chiari decompression was a large craniectomy resulting in cerebellar ptosis. We found that tonsillar reduction paired with modest craniectomy achieved near-complete resolution of symptoms with minimal complications. For patients with recurrent or persistent sequelae of Chiari malformation after decompression, revision may reduce symptom severity.


Assuntos
Malformação de Arnold-Chiari , Descompressão Cirúrgica , Reoperação , Humanos , Malformação de Arnold-Chiari/cirurgia , Feminino , Masculino , Reoperação/estatística & dados numéricos , Adulto , Descompressão Cirúrgica/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem , Estudos de Coortes , Craniectomia Descompressiva/métodos , Complicações Pós-Operatórias/epidemiologia
2.
Res Sq ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38405758

RESUMO

Background: Cerebral vasospasm (CV) is a feared complication occurring in 20-40% of patients following subarachnoid hemorrhage (SAH) and is known to contribute to delayed cerebral ischemia. It is standard practice to admit SAH patients to intensive care for an extended period of vigilant, resource-intensive, clinical monitoring. We used machine learning to predict CV requiring verapamil (CVRV) in the largest and only multi-center study to date. Methods: SAH patients admitted to UCLA from 2013-2022 and a validation cohort from VUMC from 2018-2023 were included. For each patient, 172 unique intensive care unit (ICU) variables were extracted through the primary endpoint, namely first verapamil administration or ICU downgrade. At each institution, a light gradient boosting machine (LightGBM) was trained using five- fold cross validation to predict the primary endpoint at various timepoints during hospital admission. Receiver-operator curves (ROC) and precision-recall (PR) curves were generated. Results: A total of 1,750 patients were included from UCLA, 125 receiving verapamil. LightGBM achieved an area under the ROC (AUC) of 0.88 an average of over one week in advance, and successfully ruled out 8% of non-verapamil patients with zero false negatives. Minimum leukocyte count, maximum platelet count, and maximum intracranial pressure were the variables with highest predictive accuracy. Our models predicted "no CVRV" vs "CVRV within three days" vs "CVRV after three days" with AUCs=0.88, 0.83, and 0.88, respectively. For external validation at VUMC, 1,654 patients were included, 75 receiving verapamil. Predictive models at VUMC performed very similarly to those at UCLA, averaging 0.01 AUC points lower. Conclusions: We present an accurate (AUC=0.88) and early (>1 week prior) predictor of CVRV using machine learning over two large cohorts of subarachnoid hemorrhage patients at separate institutions. This represents a significant step towards optimized clinical management and improved resource allocation in the intensive care setting of subarachnoid hemorrhage patients.

3.
J Neurointerv Surg ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38418227

RESUMO

BACKGROUND: The delivery of neuroendovascular devices requires a robust proximal access platform. This demand has previously been met with a 6Fr long sheath (8Fr guide) that is placed in the proximal internal carotid artery (ICA) or vertebral artery segments. We share our experience with the first 0.088 inch 8Fr guide catheter designed for direct intracranial access. METHODS: We retrospectively reviewed a prospectively maintained IRB-approved institutional database of the senior authors to identify all cases where the TracStar Large Distal Platform (LDP) was positioned within the intracranial vasculature, defined as within or distal to the petrous ICA, vertebral artery (V3) segments, or transverse sinus. Technical success was defined as safe placement of the TracStar LDP within or distal to the described distal vessel segments with subsequent complication-free device implantation. RESULTS: Over the 41-month study period from January 2020 to June 2023, 125 consecutive cases were identified in whom the TracStar LDP was navigated into the intracranial vasculature for triaxial delivery of large devices, 0.027 inch microcatheter and greater, for aneurysm treatment (n=108, 86%), intracranial angioplasty/stenting (n=15, 12%), and venous sinus stenting (n=2, 1.6%). All cases used a direct select catheter technique for initial guide placement (no exchange). Posterior circulation treatments occurred in 14.4% (n=18) of cases. Technical success was achieved in 100% of cases. No vessel dissections occurred in any cases. CONCLUSION: The TracStar LDP is an 0.088 inch 8Fr guide catheter that can establish direct intracranial access with an acceptable safety profile. This can be achieved in a wide range of neurointerventional cases with a high rate of technical success.

4.
Interv Neuroradiol ; : 15910199241229198, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38418397

RESUMO

INTRODUCTION: Superbore 0.088″ catheters provide a platform for optimizing aspiration efficiency and flow control during stroke mechanical thrombectomy procedures. New superbore catheters have the distal flexibility necessary to navigate complex neurovascular anatomy while providing the proximal support of traditional 8F catheters. The safety and feasibility of Zoom 88™ superbore angled-tip catheters in the middle cerebral artery (MCA) segments smaller than the catheter diameter have not been previously described. METHODS: Twenty consecutive cases of acute MCA mechanical thrombectomy were retrospectively identified from the senior authors' prospectively maintained Institutional Review Board-approved database, in which the Zoom 88 (Imperative Care, Campbell, CA) catheter was successfully navigated to at least the M1 segment. Patient demographics, procedural details, and periprocedural information were analyzed. Rates and averages (standard errors) are generally reported. RESULTS: The average National Institutes of Health Stroke Scale at presentation and age were 15 ± 2 and 73 ± 3 years, respectively. The M1 and M2 occlusions were evenly distributed. The average M1 measurements before thrombectomy ranged from 2.36 ± 0.07 mm proximally to 2.00 ± 0.11 mm distally, and after thrombectomy, they ranged from 2.34 ± 0.07 mm proximally to 1.97 ± 0.10 mm distally. First-pass modified thrombolysis in cerebral infarction (mTICI) 2C/3 recanalization was achieved in 40% of cases, and final mTICI 2C/3 recanalization was achieved in 90% of cases. A single case of mild vasospasm was managed with verapamil. No hemorrhagic or periprocedural complications were noted. CONCLUSION: Superbore 0.088″ catheters with flexible distal segments can be safely navigated to the MCA to augment mechanical thrombectomy even when the MCA segment is smaller than the catheter.

5.
J Neurol Surg Rep ; 85(1): e17-e22, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38348015

RESUMO

Formation of a carotid free-floating thrombus (CFFT) is a rare and life-threatening condition without an optimal management plan. A 78-year-old woman with a history of prior right internal carotid artery (ICA) mechanical thrombectomy and antiplatelet noncompliance presented with transient ischemic attacks secondary to a recurrent CFFT in the right ICA. Given her symptoms and recurrent CFFT, endovascular mechanical thrombectomy was performed. A balloon guide-catheter (BGC) and a Zoom 88 distal access catheter were brought into the right distal common carotid artery and proximal ICA bulb, respectively. Three 0.021-inch microcatheters, each loaded with a unique stentriever, were navigated beyond the thrombus into the upper cervical ICA and deployed in a bouquet fashion. The BGC was inflated to achieve flow arrest, and the Zoom 88 aspiration catheter was tracked over the three bouquet stentrievers to ingest the thrombus. Follow-up angiography demonstrated recanalization of the proximal cervical ICA without evidence of residual thrombus. Twenty-four-hour postoperative computed tomography imaging did not reveal any evidence of new infarction. The patient was discharged home with an intact neurological examination, compliant on aspirin and apixaban. We demonstrate a novel technique utilizing a large-bore catheter with a triple stentriever "bouquet" to thrombectomize a CFFT.

6.
Interv Neuroradiol ; : 15910199231224003, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166510

RESUMO

BACKGROUND: Endovascular embolization of the middle meningeal artery (MMA) has emerged as an adjunctive and stand-alone modality for the management of chronic subdural hematomas (cSDH). We report our experience utilizing proximal MMA coil embolization to augment cSDH devascularization in MMA embolization. METHODS: MMA embolization cases with adjunctive proximal MMA coiling were retrospectively identified from a prospectively maintained IRB-approved database of the senior authors. RESULTS: Of the 137 cases, all patients (n = 89, 100%) were symptomatic and underwent an MMA embolization procedure for cSDH. 50 of the patients underwent bilateral embolizations, with 53% (n = 72) for left-sided and 47% (n = 65) for right-sided cSDH. The anterior MMA branch was embolized in 19 (14%), posterior in 16 (12%), and both in 102 (74.5%) cases. Penetration of the liquid embolic to the contralateral MMA or into the falx was present in 38 (28%) and 31 (23%) cases, respectively, and 46 (34%) cases had ophthalmic or petrous collateral (n = 41, 30%) branches. MMA branches coiled include the primary trunk (25.5%, n = 35), primary and anterior or posterior MMA trunks (20%, n = 28), or primary with the anterior and posterior trunks (54%, n = 74). A mild ipsilateral facial nerve palsy was reported, which remained stable at discharge and follow-up. Absence of anterograde flow in the MMA occurred in 137 (100%) cases, and no cases required periprocedural rescue surgery for cSDH evacuation. The average follow-up length was 170 ± 17.9 days, cSDH was reduced by 4.24 ± 0.5(mm) and the midline shift by 1.46 ± 0.27(mm). Complete resolution was achieved in 63 (46.0%) cases. CONCLUSION: Proximal MMA coil embolization is a safe technique for providing additional embolization/occlusion of the MMA in cSDH embolization procedures. Further studies are needed to evaluate the potential added efficacy of this technique.

7.
Biomedicines ; 11(8)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37626730

RESUMO

The use of periprocedural dual antiplatelet therapy (DAPT) has significantly evolved along with innovations in the endovascular management of intracranial aneurysms. Historically, aspirin and clopidogrel have been the most commonly employed regimen due to its safety and efficacy. However, recent studies highlight the importance of tailoring DAPT regimens to individual patient characteristics which may affect clopidogrel metabolism, such as genetic polymorphisms. In the present report, a systematic review of the literature was performed to determine optimal antiplatelet use with flow diverting stents, intracranial stents, intrasaccular devices, and stent-assisted coiling. Studies were analyzed for the number of aneurysms treated, DAPT regimen, and any thromboembolic complications. Based on inclusion criteria, 368 studies were selected, which revealed the increasing popularity of alternative DAPT regimens with the aforementioned devices. Thromboembolic or hemorrhagic complications associated with antiplatelet medications were similar across all medications. DAPT with ticagrelor, tirofiban, or prasugrel are effective and safe alternatives to clopidogrel and do not require enzymatic activation. Further clinical trials are needed to evaluate different antiplatelet regimens with various devices to establish highest-level evidence-based guidelines and recommendations.

8.
J Neurointerv Surg ; 2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37586816

RESUMO

BACKGROUND: Flow diversion (FD) embolization of intracranial cerebral aneurysms is an increasingly common modality where treatment success depends on adequate vessel wall apposition of the device. This study aimed to investigate off-label use of the Comaneci device for augmenting vessel wall apposition in post-deployed flow diversion stents (FDS). METHODS: Over a 20- month period, all FD cases for the treatment of internal carotid artery (ICA) aneurysms were reviewed. Cases in which the Comaneci device was used to augment vessel wall apposition were analyzed. Data including patient demographics, case characteristics, and procedural outcomes were collected and analyzed as counts. RESULTS: From a total of 74 ICA FD cases, the Comaneci device was used to improve vessel wall apposition in 22 cases (29.7%) . Of these cases, 91% were female with a mean patient age of 64.9±11.3 years, and an average aneurysm size of 4.5±2.5 mm. Comaneci device deployment and retrieval was successful in all (100%) cases, with an average fluoroscopy time of 27.3±7.8 min, an average contrast usage of 25.8±13.2 mL, and an average radiation exposure of 915.1±320.8 mGy. Only two cases (9%) required subsequent balloon angioplasty after Comaneci deployment to improve vessel wall apposition throughout the FDS. CONCLUSION: Our experience with this technique demonstrates the feasibility of using the Comaneci device for augmentation of FDS vessel wall apposition with 100% success in the deployment and retrieval of the Comaneci device.

9.
World Neurosurg ; 178: e135-e140, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37437805

RESUMO

BACKGROUND: Narrowing of the lumbar spinal canal, or lumbar stenosis (LS), may cause debilitating radicular pain or muscle weakness. It is the most frequent indication for spinal surgery in the elderly population. Modern diagnosis relies on magnetic resonance imaging and its inherently subjective interpretation. Diagnostic rigor, accuracy, and speed may be improved by automation. In this work, we aimed to determine whether a deep-U-Net ensemble trained to segment spinal canals on a heterogeneous mix of clinical data is comparable to radiologists' segmentation of these canals in patients with LS. METHODS: The deep U-nets were trained on spinal canals segmented by physicians on 100 axial T2 lumbar magnetic resonance imaging selected randomly from our institutional database. Test data included a total of 279 elderly patients with LS that were separate from the training set. RESULTS: Machine-generated segmentations (MA) were qualitatively similar to expert-generated segmentations (ME1, ME2). Machine- and expert-generated segmentations were quantitatively similar, as evidenced by Dice scores (MA vs. ME1: 0.88 ± 0.04, MA vs. ME2: 0.89 ± 0.04), the Hausdorff distance (MA vs. ME1: 11.7 mm ± 13.8, MA vs. ME2: 13.1 mm ± 16.3), and average surface distance (MAvs. ME1: 0.18 mm ± 0.13, MA vs. ME2 0.18 mm ± 0.16) metrics. These metrics are comparable to inter-rater variation (ME1 vs. ME2 Dice scores: 0.94 ± 0.02, the Hausdorff distances: 9.3 mm ± 15.6, average surface distances: 0.08 mm ± 0.09). CONCLUSION: We conclude that machine learning algorithms can segment lumbar spinal canals in LS patients, and automatic delineations are both qualitatively and quantitatively comparable to expert-generated segmentations.


Assuntos
Aprendizado de Máquina , Canal Medular , Humanos , Idoso , Constrição Patológica , Canal Medular/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
10.
Adv Med Educ Pract ; 14: 773-782, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37483525

RESUMO

Background: There is an increasing need for medical innovators to help address the growing challenges within health care. Despite this, the rate of adoption of new medical innovation programs at the United States (US) medical schools has been slow. Existing literature explaining this slow rate of adoption is scant. We examined the rate of student enrollment in a voluntary medical innovation course during an unscheduled summer at our institution and the educational backgrounds of these enrollees. Methods: This mixed qualitative and quantitative survey study comprised consecutive surveys quantifying a two-stage sign-up process for a voluntary summer medical innovation course for Medical Doctorate (MD) candidates at the David Geffen School of Medicine. After a "General interest" survey, interested students completed an "Enrollment" survey to indicate enrollment, educational background, and open-ended comment about motivations for enrollment. Surveys were administered electronically via email listservs. Statistical methods included chi squared testing with statistical significance defined as p < 0.05. Findings: A total of 12% of UCLA Class of 2024 expressed an interest in participation in the program, and 10.3% ultimately enrolled. Enrollees were motivated primarily by the opportunity to learn about medical innovation (72%) and also shadow (28%). Enrollees were similar in undergraduate degrees and majors to the general medical student class and US MD candidate population. Conclusion: A lack of medical student willingness to participate may not underlie the observed slow rate of adoption of medical innovation programs at US MD programs given the observed high voluntary enrollment rate. Enrollee educational background did not differ significantly from non-enrollees or the broader US MD candidate population. Educators should be encouraged by these data to explore student willingness to participate in medical innovation education at their institutions.

11.
J Neurointerv Surg ; 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37500479

RESUMO

BACKGROUND: Sympathetic-mediated vasoconstriction from the superior cervical ganglion (SCG) is a significant contributor to cerebral vasospasm. Inhibition of the SCG has been shown to improve cerebral blood flow and reverse cerebral vasospasm in swine models. We evaluated the efficacy of a novel minimally invasive endovascular approach to target and pharmacologically inhibit the SCG, using a Micro-Infusion Device for transmural drug delivery. METHODS: Eight SCGs in four Yorkshire swine were surgically identified. After confirming appropriate sympathetic-mediated intracranial vasoconstriction response with SCG stimulation, an endovascular Micro-Infusion Device was used for transmural targeting of the SCG and delivery of 1.5-2 mL of 1% lidocaine-contrast mixture to the perivascular space. Digital subtraction angiography was obtained at: (1) baseline; (2) with SCG stimulation; and (3) after lidocaine delivery to the SCG using the Micro-Infusion Device with concurrent SCG stimulation. Vessel diameters were measured and compared. RESULTS: Endovascular transmural delivery of lidocaine to the SCG and carotid perivascular tissue using the Micro-Infusion Device successfully inhibited sympathetic-mediated vasoconstriction response. Measured vessel diameters after lidocaine delivery were comparable to baseline despite SCG stimulation. CONCLUSION: A novel endovascular technique of transmural delivery of lidocaine to the SCG and carotid artery perivascular tissues successfully inhibits the sympathetic input to the cerebral vasculature and modulates sympathetic-mediated cerebral vasospasm. These results suggest promising steps towards translation to potential clinical use for patients suffering from cerebral vasospasm.

12.
Oper Neurosurg (Hagerstown) ; 24(2): 209-220, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36637306

RESUMO

BACKGROUND: Extracranial to intracranial bypass is used to augment and/or replace the intracranial circulation for various pathologies. The superficial temporal artery is the mainstay donor for pedicled bypasses to the anterior circulation but can be limited by its variable size, low native flow rates, and potential scalp complications. Interposition grafts such as the radial artery or greater saphenous vein are alternatives but are sometimes limited by size mismatch, length needed to reach the extracranial circulation, and loss of inherent vascular elasticity. Interposition grafts between the maxillary artery (IMA) and middle cerebral artery (MCA) address these limitations. OBJECTIVE: To explore the feasibility of harvesting the IMA through an endoscopic transnasal, transmaxillary approach to perform a direct IMA to MCA bypass. METHODS: Combined transcranial and endoscopic endonasal dissections were performed in embalmed human cadavers to harvest the IMAs for intracranial transposition and direct anastomosis to the MCA. Donor and recipient vessel calibers were measured and recorded. RESULTS: A total of 8 procedures were performed using the largest and distal-most branches of the IMA (the sphenopalatine branch and the descending palatine branch) as pedicled conduits to second division of middle cerebral artery (M2) recipients. The mean diameter of the IMA donors was 1.89 mm (SD ± 0.42 mm), and the mean diameter of the recipient M2 vessels was 1.90 mm (SD ± 0.46 mm). CONCLUSION: Endoscopic harvest of the IMA using a transnasal, transmaxillary approach is a technically feasible option offering an excellent size match to the M2 divisions of the MCA and the advantages of a relatively short, pedicled donor vessel.


Assuntos
Revascularização Cerebral , Artéria Cerebral Média , Humanos , Artéria Cerebral Média/cirurgia , Artéria Maxilar/cirurgia , Estudos de Viabilidade , Revascularização Cerebral/métodos , Endoscópios
13.
J Neurointerv Surg ; 15(10): 1007-1013, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36319086

RESUMO

BACKGROUND: Recent advances in endovascular devices have allowed access and targeting of perivascular tissues of the peripheral circulation. The perivascular tissues of the cervical and cranial circulations have many important structures of clinical significance, yet the feasibility and safety of such an approach has not been demonstrated. OBJECTIVE: To evaluate the safety of a novel endovascular transmural approach to target the perivascular tissues of the common carotid artery in swine. METHODS: A micro-infusion device was positioned in the carotid arteries of three Yorkshire pigs (six carotid arteries in total), and each carotid artery was punctured 10 times in the same location to gain access to the perivascular tissues. Digital subtraction angiography was used to evaluate vessel injury or contrast extravasation. MRI and MR angiography were used to evaluate evidence of cerebral ischemia or vessel injury. Post-mortem tissue analysis was performed to assess the level of extravascular hematoma and intravascular dissection. RESULTS: None of the tested carotid arteries showed evidence of vessel injury (dissection or perforation) or intravascular thrombosis. MRI performed after repeated puncture was negative for neck hematoma and brain ischemia. Post-mortem tissue analysis of the carotid arteries showed mild adventitial staining with blood, but without associated hematoma and without vessel dissection. CONCLUSION: Repeated puncture of the carotid artery to gain access to the perivascular tissues using a novel endovascular transmural approach is safe in a swine model. This represents a novel approach to various tissues in close proximity to the cervical and cranial vasculature.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , Suínos , Animais , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Artéria Carótida Primitiva , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/etiologia , Angiografia Digital , Hematoma , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos
14.
Front Bioeng Biotechnol ; 11: 1339831, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38283172

RESUMO

Introduction: Ventriculoperitoneal (VP) shunts divert cerebrospinal fluid (CSF) out of cerebral ventricles in patients with hydrocephalus or elevated intracranial pressure (ICP). Despite high failure rates, there exist limited clinically viable solutions for long-term and continuous outpatient monitoring of CSF flow rate through VP shunts. We present a novel, low-power method for sensing analog CSF flow rate through a VP shunt premised on induced spatial electrical charge variation. Methods: Two geometric variants of the proposed sensing mechanism were prototyped: linear wire (P1) and cylindrical (P2) electrodes. Normal saline was gravity-driven through P1 and a commercially available shunt system in series. True flow rates were measured using a high-precision analytical balance. Subsequently, artificial CSF was driven by a programmable syringe pump through P2. Flow rate prediction models were empirically derived and tested. Sensor response was also assessed during simulated obstruction trials. Finally, power consumption per flow measurement was measured. Results: P1 (17 mm long) and P2 (22 mm long) averaged 7.2% and 4.2% error, respectively, in flow rate measurement from 0.01 to 0.90 mL/min. Response curves exhibited an appreciably flattened profile during obstruction trials compared to non-obstructed states. P2 consumed 37.5 µJoules per flow measurement. Conclusion: We propose a novel method for accurately sensing CSF flow rate through a VP shunt and validate this method at the benchtop with normal saline and artificial CSF over a board range of flows (0.01-0.90 mL/min). The sensing element is highly power efficient, compact, insertable into existing shunt and valve assemblies, and does not alter CSF flow mechanics.

15.
J Vasc Interv Neurol ; 13(1): 35-41, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36447624

RESUMO

Introduction: Sympathetic activity from the superior cervical ganglion (SCG) has been shown to cause cerebral hypoperfusion in swine, similar to that seen with clinical cerebral vasospasm. Although the mechanism of such perfusion deficit has been speculated to be from pathologic cerebral vasoconstriction, the extent of sympathetic contribution to vasoconstriction has not been wellestablished. Objective: We aimed to demonstrate that SCG stimulation in swine leads to significant cerebral vasoconstriction on digital subtraction angiography (DSA). Additionally, we aimed to show that inhibition of SCG can mitigate the effects of sympathetic-mediated cerebral vasoconstriction. Methods: Five SCGs were surgically identified in Yorkshire swine and were electrically stimulated to achieve sympathetic activation. DSA was performed to measure and compare changes in cerebral vessel diameter. Syngo iFlow was also used to quantify changes in contrast flow through the cerebral and neck vessels. Results: SCG stimulation resulted in 35-45% narrowing of the ipsilateral ascending pharyngeal, anterior middle cerebral and anterior cerebral arteries. SCG stimulation also decreased contrast flow through ipsilateral ascending pharyngeal, internal carotid and anterior cerebral arteries as seen on iFLow. These effects were prevented with prior SCG blockade. Minimal vessel caliber changes were seen in the posterior cerebral, posterior middle cerebral and internal carotid arteries with SCG stimulation. Conclusion: SCG stimulation results in significant luminal narrowing and reduction in flow through various intracranial arteries in swine. The results of sympathetic hyperactivity from the SCG closely models cerebral vasoconstriction seen in human cerebral vasospasm. SCG inhibition is a potential promising therapeutic approach to treating cerebral vasospasm.

16.
World Neurosurg ; 168: e621-e625, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36307037

RESUMO

OBJECTIVE: To assess volumetric changes in the spinal cord at the cervicomedullary junction, diameter of the cervicomedullary cord, and width of the brainstem following posterior fossa decompression (PFD). METHODS: A retrospective analysis of adult patients with Chiari malformation who underwent PFD was performed. Segmentations were done on clinical quality T2-weighted cervical magnetic resonance images obtained before and after decompression using ITK-SNAP. Volumes of neural tissue within the cervicomedullary junction were evaluated from 10 mm cranial to the medullary beak to the cervical spinal cord at the level of the caudal endplate of the second cervical vertebra. The diameter of the cervicomedullary cord was calculated perpendicular to the spinal cord. The width of the brainstem was measured perpendicular to the clivus at the level of the basion. RESULTS: Twenty adult patients, a mean age of 49.55 years, were included. The cervical cord increased in volume by 13 mm3 to 338 mm3, with an average increase of 155 mm3 (P-value of 0.00002). The diameter of the cervicomedullary cord increased 10.30% 7 mm superior to the beak (P-value of 0.00074), 11.49% at the apex of the beak (P-value of 0.00082), 8.29% 7 mm inferior to the beak (P-value of 0.00075), and the brainstem increased 14.46% perpendicular to the clivus (P-value of 0.00109). The spinal cord at the inferior aspect of the C3 vertebra changed insignificantly (P-value of 0.10580). CONCLUSION: The volume of the cervical cord at the cervical-medullary junction, width of the cervicomedullary cord, and diameter of the brainstem increase following PFD.


Assuntos
Malformação de Arnold-Chiari , Descompressão Cirúrgica , Humanos , Adulto , Pessoa de Meia-Idade , Descompressão Cirúrgica/métodos , Estudos Retrospectivos , Resultado do Tratamento , Malformação de Arnold-Chiari/diagnóstico por imagem , Malformação de Arnold-Chiari/cirurgia , Malformação de Arnold-Chiari/patologia , Medula Espinal/diagnóstico por imagem , Medula Espinal/cirurgia , Medula Espinal/patologia , Imageamento por Ressonância Magnética
17.
Auton Neurosci ; 241: 102987, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35567916

RESUMO

INTRODUCTION: Cerebral vasospasm is a complex disease resulting in reversible narrowing of blood vessels, stroke, and poor patient outcomes. Sympathetic perivascular nerve fibers originate from the superior cervical ganglion (SCG) to innervate the cerebral vasculature, with activation resulting in vasoconstriction. Sympathetic pathways are thought to be a significant contributor to cerebral vasospasm. OBJECTIVE: We sought to demonstrate that stimulation of SCG in swine can cause ipsilateral cerebral perfusion deficit similar to that of significant human cerebral vasospasm. Furthermore, we aimed to show that inhibition of SCG can block the effects of sympathetic-mediated cerebral hypoperfusion. METHODS: SCG were surgically identified in 15 swine and were electrically stimulated to achieve sympathetic activation. CT perfusion scans were performed to assess for changes in cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT) and time-to-maximum (TMax). Syngo.via software was used to determine regions of interest and quantify perfusion measures. RESULTS: SCG stimulation resulted in 20-30% reduction in mean ipsilateral CBF compared to its contralateral unaffected side (p < 0.001). Similar results of hypoperfusion were seen with CBV, MTT and TMax with SCG stimulation. Prior injection of lidocaine to SCG inhibited the effects of SCG stimulation and restored perfusion comparable to baseline (p > 0.05). CONCLUSION: In swine, SCG stimulation resulted in significant cerebral perfusion deficit, and this was inhibited by prior local anesthetic injection into the SCG. Inhibiting sympathetic activation by targeting the SCG may be an effective treatment for sympathetic mediated cerebral hypoperfusion.


Assuntos
Vasoespasmo Intracraniano , Animais , Circulação Cerebrovascular , Gânglio Cervical Superior , Suínos , Sistema Nervoso Simpático/fisiologia
18.
Neurosurgery ; 91(3): 389-398, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35551167

RESUMO

BACKGROUND: Chronic subdural hematomas (CSDHs) are common in the elderly population and patients taking antiplatelet/anticoagulation medications. Middle meningeal artery (MMA) embolization has become an adjunctive treatment to observation and surgery. Despite many embolization techniques, best practices for optimal CSDH resolution remain unknown. OBJECTIVE: To report a retrospective case series of MMA embolization for CSDHs regarding rate of hematoma improvement and the significance of distal embolic penetration into the falx. METHODS: Retrospective chart review was performed on all patients who underwent MMA embolization for CSDHs between January 2017 and June 2021. Patient demographics, clinical presentation, anticoagulant use, and radiographic features were collected. Pre-embolization and postembolization computed tomography scans were analyzed for volumetric changes and assessed for midline penetration of embolic material in the falx. RESULTS: MMA embolization was performed in 37 patients and 53 hemispheres. Older patients took longer to obtain complete resolution of CSDHs (r = 0.47, P = .03). Patients with larger pre-embolization (r = 0.57, P = .007) and postembolization (r = 0.56, P = .008) CSDH volumes took longer to completely resolve. Patients who had n-butyl cyanoacrylate embolization with midline penetration, as evidenced by the "bright falx" sign, had faster improvement rates than those who did not (5.64 cm 3 /d vs 1.2 cm 3 /d, P = .02). CONCLUSION: Distal penetration of embolic material, particularly n-butyl cyanoacrylate, into the falx may lead to more rapid improvement of CSDH.


Assuntos
Embolização Terapêutica , Hematoma Subdural Crônico , Idoso , Cianoacrilatos , Embolização Terapêutica/métodos , Hematoma Subdural Crônico/diagnóstico por imagem , Hematoma Subdural Crônico/terapia , Humanos , Artérias Meníngeas/diagnóstico por imagem , Artérias Meníngeas/cirurgia , Inibidores da Agregação Plaquetária , Estudos Retrospectivos
19.
World Neurosurg ; 156: e72-e76, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34500098

RESUMO

OBJECTIVE: We examined the role of intrawound vancomycin powder as prophylaxis against postoperative surgical site infection (SSI) after spinal cord stimulator (SCS) implantation. METHODS: We performed a retrospective analysis of 153 consecutive patients who had undergone permanent SCS implantation surgery via open laminectomy between 2014 and 2020. We queried the patients' medical records for patient age, sex, relevant medical history, and whether intrawound vancomycin had been administered. We compared the rates of SSI (primary outcome) and seroma (secondary outcome) within 3 months after surgery between the vancomycin and no-vancomycin groups. Finally, we conducted multivariable logistic regression analyses to identify independent predictors of postoperative SSI or seroma. RESULTS: Of the 153 patients, 59% were women, and the average age was 65.4 years. Overall, 3 patients (2%) had developed an SSI: 2 (methicillin-resistant Staphylococcus aureus, Klebsiella) in the vancomycin group and 1 (methicillin-sensitive Staphylococcus aureus) in the no-vancomycin group. This difference in SSI rate between the 2 groups was insignificant (P = 0.73). Three seromas, all in the no-vancomycin group, accounted for a statistically significant difference in seroma formation between the 2 groups (P = 0.04). Multivariate logistic regression failed to identify any perioperative characteristics as independent predictors of postoperative SSI or seroma. CONCLUSIONS: Our experience suggests open laminectomy for SCS implantation surgery can be performed with a low postoperative SSI rate, with or without the use of powdered vancomycin. We found no evidence suggesting that the use of powdered vancomycin is unsafe or related to postoperative seroma formation. We failed to draw any definitive conclusions regarding its efficacy, despite referencing the largest single case series of SCS implantation to date.


Assuntos
Neuroestimuladores Implantáveis , Laminectomia/métodos , Estimulação da Medula Espinal/métodos , Doenças da Coluna Vertebral/terapia , Infecção da Ferida Cirúrgica/prevenção & controle , Vancomicina/administração & dosagem , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Neuroestimuladores Implantáveis/efeitos adversos , Laminectomia/efeitos adversos , Laminectomia/instrumentação , Masculino , Pessoa de Meia-Idade , Pós , Estudos Retrospectivos , Estimulação da Medula Espinal/efeitos adversos , Estimulação da Medula Espinal/instrumentação , Doenças da Coluna Vertebral/diagnóstico , Infecção da Ferida Cirúrgica/diagnóstico
20.
Neurosurgery ; 88(1): 25-35, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-32658958

RESUMO

BACKGROUND: Pipeline Embolization Device (PED; Medtronic) "twisting" manifests with the appearance of a "figure 8" in perpendicular planes on digital subtraction angiography. This phenomenon has received little attention in the literature, requires technical precision to remediate, and has potential to cause ischemic stroke if not properly remediated. OBJECTIVE: To report incidence, risk factors, and sequelae of PED twisting and to discuss techniques to remediate a PED twist. METHODS: Case images were reviewed for instances of twisting from a prospectively-maintained, Institutional Review Board-approved cohort of patients undergoing flow diversion for cerebral aneurysm. RESULTS: From August 2011 to December 2017, 999 PED flow diverting stents were attempted in 782 cases for 653 patients. A total of 25 PED twists were observed while treating 20 patients (2.50%, 25/999). Multivariate analysis revealed predictors of twisting to be: Large and giant aneurysms (odds ratio (OR) = 9.66, P = .005; OR = 27.47, P < .001), increased PED length (OR = 1.14, P < .001), and advanced patient age (OR = 1.07, P = .002). Twisted PEDs were able to be remediated 75% of the time, and procedural success was achieved in 90% of cases. PED twisting was not found to be a significant cause of major or minor complications. However, at long-term follow-up, there was a trend towards poor occlusion outcomes for the cases that encountered twisting. CONCLUSION: Twisting is a rare event during PED deployment that was more likely to occur while treating large aneurysms with long devices in older patients. While twisting did not lead to major complications in this study, remediation can be challenging and may be associated with inferior occlusion outcomes.


Assuntos
Prótese Vascular/efeitos adversos , Embolização Terapêutica/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Aneurisma Intracraniano/terapia , Complicações Intraoperatórias/epidemiologia , Adulto , Idoso , Estudos de Coortes , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Humanos , Incidência , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...