RESUMO
AIM: To evaluate the effect of modification of dose mode and frame rate on patient radiation dose during modified barium swallow (MBS) examinations. MATERIALS AND METHODS: A retrospective review was undertaken of consecutive MBS examinations performed over 6 months in the inpatient setting. Patients were divided into two cohorts: pre-implementation of the MBS Impairment Profile (MBSImP; low rate, normal dose) and post-implementation (high rate, low dose). Prior to implementation, pulse rate and dose testing were performed on multiple phantoms. RESULTS: Four hundred and forty-nine patients were included in the pre-implementation cohort and 378 in the post-implementation cohort. Phantom dose testing demonstrated no significant difference in dose on either phantom between low rate/normal dose and high rate/low dose modes. Prior to MBS standardisation, the mean radiation dose was 5.86 (±4.35) mGy. Following standardisation, the mean radiation dose was 4.72 (±3.77) mGy (p<0.0001). The mean fluoroscopy time for MBS prior to standardisation was 83.8 (±44.4) seconds and the mean fluoroscopy time for MBS after standardisation was 82.3 (±39.8) seconds (p=0.62). The dose rate for MBS prior to standardisation was 4.35 (±2.42) and the dose rate for MBS after standardisation was 3.55 (±2.41) mGy/s (p<0.0001). CONCLUSION: Adjustments made to lower the dose mode and the increase in fluoroscopy frame rate decreased the patient radiation dose and did not increase fluoroscopy time.
Assuntos
Sulfato de Bário/administração & dosagem , Meios de Contraste/administração & dosagem , Transtornos de Deglutição/diagnóstico por imagem , Doses de Radiação , Administração Oral , Adulto , Feminino , Fluoroscopia , Frequência Cardíaca , Humanos , Masculino , Imagens de Fantasmas , Estudos Retrospectivos , Fatores de TempoRESUMO
This article provides an overview of the current surgical anti-reflux procedures and their imaging findings, as well as the surgical complications. Accurate and timely clinical assessment requires an engaged radiologist fluoroscopist who understands the perspectives of their interdisciplinary colleagues, including the surgeon and gastroenterologist. The complex pathophysiology calls for an interdisciplinary approach, and the radiologist needs to tailor their evaluation to answer the specific questions posed by their clinical colleagues and by the presenting symptomatology.