Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Eur J Radiol ; 175: 111454, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38598964

RESUMO

OBJECTIVES: To evaluate the additional diagnostic benefit of diffusion weighted imaging (DWI) and contrast enhanced (CE) images during MR enterography (MRE) of Crohn's disease. METHODS: Datasets from 73 patients (mean age 32; 40 male) (28 new-diagnosis, 45 relapsed) were read independently by two radiologists selected from a pool of 13. Radiologists interpreted datasets using three sequential sequence blocks: (1) T2 weighted and steady state free precession gradient echo (SSFP) images alone (T2^); (2) T2 weighted and SSFP images with DWI (T2 + DWI^) and; (3) T2 weighted images, SSFP, DWI and post-contrast enhanced (CE) T1 images (T2 + DWI + CE^), documenting presence, location, and activity of small bowel disease. For each sequence block, sensitivity and specificity (readers combined) was calculated against an outcome-based construct reference standard. RESULTS: 59/73 patients had small bowel disease. Per-patient sensitivity for disease detection was essentially identical (80 % [95 % CI 72, 86], 81 % [73,87], and 79 % [71,86] for T2^, T2 + DWI^and T2 + DWI + CE^respectively). Specificity was identical (82 % [64 to 92]). Per patient sensitivity for disease extent was 56 % (47,65), 56 % (47,65) and 52 % (43 to 61) respectively, and specificity was 82 % (64 to 92) for all blocks. Sensitivity for active disease was 97 % (90,99), 97 % (90,99) and 98 % (92,99), and specificity was also comparable between all sequence combination reads. Results were consistent across segments and newly diagnosed/relapse patients. CONCLUSION: There is no additional diagnostic benefit of adding either DWI or CE to T2 FSE and SSFP sequences for evaluating small bowel Crohn's disease, suggesting MRE protocols can be simplified safely.


Assuntos
Meios de Contraste , Doença de Crohn , Imagem de Difusão por Ressonância Magnética , Sensibilidade e Especificidade , Humanos , Doença de Crohn/diagnóstico por imagem , Masculino , Feminino , Adulto , Imagem de Difusão por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adolescente , Idoso , Adulto Jovem , Aumento da Imagem/métodos
2.
Eur Radiol ; 34(1): 455-464, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37526665

RESUMO

OBJECTIVES: The simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. METHODS: Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). RESULTS: We included 284 patients (median 31.5 years, IQR 23-46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69-86%) and 50% (31-69%) for SUS-CD, and 66% (56-75%) and 68% (47-84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74-86%) and 75% (66-83%) for SUS-CD, and 68% (61-74%) and 85% (76-91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). CONCLUSIONS: Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting. CLINICAL RELEVANCE STATEMENT: When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohn's disease, especially when compared to a magnetic resonance reference standard. KEY POINTS: The simple ultrasound activity score for Crohn's disease and bowel ultrasound score are promising intestinal ultrasound indices of Crohn's disease but to date studied mainly in small settings with few sonographers. Compared to histology and the magnetic resonance reference standard in a multicentre, multireader setting, the sensitivity of simple ultrasound activity score for Crohn's disease is significantly greater than that of bowel ultrasound score. The specificity of simple ultrasound activity score for Crohn's disease was significantly lower than that of bowel ultrasound score compared to the magnetic resonance enterography reference standard. The specificity of both indices was numerically higher when the magnetic resonance enterography reference standard was adopted.


Assuntos
Doença de Crohn , Adulto , Humanos , Doença de Crohn/patologia , Íleo/diagnóstico por imagem , Íleo/patologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
3.
Acta Radiol ; 64(5): 1873-1879, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36437570

RESUMO

BACKGROUND: Interruptions are a cause of discrepancy, errors, and potential safety incidents in radiology. The sources of radiological error are multifactorial and strategies to reduce error should include measures to reduce interruptions. PURPOSE: To evaluate the effect of simple changes in the reporting environment on the frequency of interruptions to the reporting radiologist of a hospital radiology department. MATERIAL AND METHODS: A prospective observational study was carried out. The number and type of potentially disruptive events (PDEs) to the radiologist reporting inpatient computed tomography (CT) scans were recorded during 20 separate 1-h observation periods during both pre- and post-intervention phases. The interventions were (i) relocation of the radiologist to a private, quiet room, and (ii) initial vetting of clinician enquiries via a separate duty radiologist. RESULTS: After the intervention there was an 82% reduction in the number of frank interruptions (PDEs that require the radiologist to abandon the reporting task) from a median 6 events per hour to 1 (95% confidence interval [CI] = 4-6; P < 0.00001). The overall number of PDEs was reduced by 56% from a median 11 events per hour to 5 (95% CI = 4.5-11: P < 0.00001). CONCLUSION: Relocation of inpatient CT reporting to a private, quiet room, coupled with vetting of clinician enquiries via the duty radiologist, resulted in a large reduction in the frequency of interruptions, a frequently cited avoidable source of radiological error.


Assuntos
Radiologistas , Radiologia , Humanos , Estudos Prospectivos
4.
Eur J Radiol ; 153: 110368, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35636024

RESUMO

PURPOSE: Iodinated radiographic contrast media has been associated with an acute deterioration in renal function, termed contrast induced nephropathy (CIN). This review aims to establish the efficacy of prophylaxis interventions used in adult patients prior to intravenous exposure to iodinated contrast to reduce the risk of CIN. METHODS: An electronic search for published peer-reviewed articles was performed, supplemented with manual review of references from previous systematic reviews and the National Institute for Health and Care Excellence guidelines. Risk of bias was assessed using the Cochrane Collaboration's tool for assessing risk of bias. Random-effect meta-analyses were used to assess CIN incidence, need for kidney replacement therapy (KRT), mortality, fluid overload and persistent kidney dysfunction. RESULTS: 22 studies assessing a range of interventions were included in the qualitative analysis. The incidence of CIN was reduced by the use of N-acetylcysteine compared to a control group of saline (risk difference = -0.07, 95% CI -0.13 to -0.01) but not by sodium bicarbonate compared to control group of saline (risk difference = -0.02, 95% CI -0.04 to 0.01). Published studies give no indication that prophylactic interventions have significant impact on the need for KRT, mortality or persistent renal impairment. CONCLUSION: Evidence for prophylaxis against CIN in patients receiving intravenous iodinated contrast is limited. There was an association with the use of NAC with reduced incidence of CIN following intravenous contrast but there was no impact on other clinical outcomes assessed. The clinical significance of these findings remains unclear and further research focusing on these clinical outcomes is required.


Assuntos
Nefropatias , Insuficiência Renal , Acetilcisteína/uso terapêutico , Adulto , Meios de Contraste/efeitos adversos , Humanos , Nefropatias/induzido quimicamente , Nefropatias/prevenção & controle , Insuficiência Renal/induzido quimicamente , Bicarbonato de Sódio/efeitos adversos
5.
Eur Radiol ; 32(8): 5075-5085, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35243523

RESUMO

OBJECTIVES: To compare the distention quality and patient experience of oral mannitol and polyethylene glycol (PEG) for MRE. METHODS: This study is a retrospective, observational study of a subset of patients enrolled in a multicentre, prospective trial evaluating the diagnostic accuracy of MRE for small bowel Crohn's. Overall and segmental MRE small bowel distention, from 105 patients (64 F, mean age 37) was scored from 0 = poor to 4 = excellent by two experienced observers (68 [65%] mannitol and 37 [35%] PEG). Additionally, 130 patients (77 F, mean age 34) completed a questionnaire rating tolerability of various symptoms immediately and 2 days after MRE (85 [65%] receiving mannitol 45 [35%] receiving PEG). Distension was compared between agents and between those ingesting ≤ 1 L or > 1 L of mannitol using the test of proportions. Tolerability grades were collapsed into "very tolerable," "moderately tolerable," and "not tolerable." RESULTS: Per patient distension quality was similar between agents ("excellent" or "good" in 54% [37/68] versus 46% [17/37]) with mannitol and PEG respectively. Jejunal distension was significantly better with mannitol compared to PEG (40% [27/68] versus 14% [5/37] rated as excellent or good respectively). There was no significant difference according to the volume of mannitol ingested. Symptom tolerability was comparable between agents, although fullness following MRE was graded as "very tolerable" in 27% (12/45) of patients ingesting PEG, verses 44% (37/84) ingesting mannitol, difference 17% (95% CI 0.6 to 34%). CONCLUSION: Mannitol-based solutions and PEG generally achieve comparable distension quality and side effect profiles, although jejunal distension is better quality with mannitol. Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. KEY POINTS: • Mannitol-based and PEG-based oral preparation agents generally achieve comparable distension quality for MRE with the exception of the jejunum which is better distended with mannitol. • Mannitol-based and PEG-based oral preparation agents used for MRE have similar side effect profiles. • Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol.


Assuntos
Doença de Crohn , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Adulto , Meios de Contraste/farmacologia , Doença de Crohn/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Manitol/farmacologia , Avaliação de Resultados da Assistência ao Paciente , Polietilenoglicóis , Estudos Prospectivos , Estudos Retrospectivos
6.
Br J Radiol ; 95(1134): 20210995, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35195444

RESUMO

OBJECTIVES: To evaluate interobserver variability for diagnosis of disease presence and extent of small bowel and colonic Crohn's disease using MR enterography (MRE). METHODS: Data from the first 73 consecutive patients (mean age 32, 33F, 28 new diagnosis, 45 suspected relapse) recruited to a multicentre, prospective diagnostic accuracy trial evaluating MRE for small bowel Crohn's disease were each read independently by three (from a pool of 20) radiologists. Radiologists documented presence and segmental location of small bowel Crohn's disease and recorded morphological mural/extramural parameters for involved segments. Per patient percentage agreement for disease presence and extent were calculated against an outcome-based construct reference standard (averaged between pairs of readers). Prevalence-adjusted bias-adjusted κ (PABAK) was calculated. RESULTS: Agreement for small bowel disease presence for new diagnosis/relapsed patients was 68%(κ = 0.36)/ 78% (κ = 0.56) and 43%(κ = 0.14)/ 53% for disease extent (κ = 0.07), respectively. For disease presence, all three radiologists agreed correctly with the reference standard in 41/59 (69%) of patients with small bowel involvement, and in 8/14 (57%) cases of without small bowel disease. Agreement was highest for multisegment disease, greater than 5 cm in length, with mural thickness>6 mm, and increased mural T2 signal. Agreement for colonic disease presence was 61% (κ = 0.21 fair agreement) for new diagnosis/ 60% (κ = 0.20, slight agreement) for relapsed patients. CONCLUSION: There is a reasonable agreement between radiologists for small bowel disease presence using MRE for newly diagnosed Crohn's disease, and patients with suspected relapse, respectively. Agreement is lower for disease extent. ADVANCES IN KNOWLEDGE: There is reasonable agreement between radiologists for small bowel disease presence using MRE for newly diagnosed (68%) Crohn's disease, and patients with suspected relapse (78%). Agreement is lower for disease extent (43% new diagnosis and 53% suspected relapse).


Assuntos
Doença de Crohn , Adulto , Ensaios Clínicos como Assunto , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Estudos Multicêntricos como Assunto , Variações Dependentes do Observador , Estudos Prospectivos , Recidiva
8.
Radiographics ; 41(3): 909-928, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33939544

RESUMO

The renal arteries (RAs) are important vessels that usually arise from the abdominal aorta and supply the kidneys; thus, these arteries play a vital role in physiologic functions such as hemofiltration and blood pressure regulation. An understanding of the basis for embryologic development and the frequently variable anatomy of the RAs is necessary to fully appreciate the range of diseases and the implications for procedural planning. Hemorrhage from an RA is relatively common and is typically traumatic or spontaneous, with the latter form often seen in association with underlying tumors or arteriopathy. Accurate diagnostic evaluation of RA disease due to conditions such as atherosclerosis, fibromuscular dysplasia, vasculitis, aneurysm, arteriovenous shunt, embolic disease, and dissection is dependent on the use of multimodality imaging and is essential for selecting appropriate clinical management, with endovascular therapy having a key role in treatment. Surgical considerations include extra-anatomic renal bypass, which remains an important treatment option even in this era of endovascular therapy, and RA embolization as an adjunct to tumor surgery. A novel area of research interest is the potential role of RA denervation in the management of refractory hypertension. ©RSNA, 2021.


Assuntos
Fístula Arteriovenosa , Procedimentos Endovasculares , Aorta Abdominal , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/terapia , Humanos , Rim/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem
10.
J R Coll Physicians Edinb ; 51(1): 106-110, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33877156
11.
Clin Anat ; 33(3): 350-354, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31444816

RESUMO

Multiple medical interventions require percutaneous instrumentation of the anterior abdominal wall, all of which carry a potential for vascular trauma. We assessed the presence, position, and size of the anterior abdominal wall superior and inferior (deep) epigastric arteries to determine the safest site with respect to vascular anatomy of the rectus sheath. In a review of 100 arterial phase, contrast-enhanced abdominal computed tomography scans, anterior abdominal wall arteries were assessed bilaterally at three axial planes: transpyloric, umbilicus, and anterior superior iliac spine (ASIS). The mean age of patients was 69.2 years (SD ± 15), with 62 male and 38 female. An artery was visible least frequently at the transpyloric plane (5%), compared with the umbilicus (72-79%) and ASIS (93-96%), on the left (χ2 (4) = 207.272; P < 0.001) and right (χ2 (4) = 198.553; P < 0.001), with a moderate strength association (Cramer's V = 0.588 (left) and 0.575 (right)). The arteries were most commonly observed within the rectus abdominis muscle at the level of the umbilicus and ASIS on both sides (62-68%). The inferior epigastric artery was observed to be larger in diameter, start more laterally, and move medially as it travelled superiorly. These data suggest that the safest site to instrument the rectus sheath, with respect to vascular anatomy, is at the transpyloric plane. This information on anatomical variation of the anterior abdominal wall vasculature may be of particular interest to anesthetists performing rectus sheath block and surgeons during laparoscopic port insertion. Clin. Anat. 33:350-354, 2020. © 2019 Wiley Periodicals, Inc.


Assuntos
Parede Abdominal/irrigação sanguínea , Parede Abdominal/diagnóstico por imagem , Artérias Epigástricas/diagnóstico por imagem , Reto do Abdome/irrigação sanguínea , Reto do Abdome/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Laparotomia/instrumentação , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
12.
Health Technol Assess ; 23(42): 1-162, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31432777

RESUMO

BACKGROUND: Magnetic resonance enterography and enteric ultrasonography are used to image Crohn's disease patients. Their diagnostic accuracy for presence, extent and activity of enteric Crohn's disease was compared. OBJECTIVE: To compare diagnostic accuracy, observer variability, acceptability, diagnostic impact and cost-effectiveness of magnetic resonance enterography and ultrasonography in newly diagnosed or relapsing Crohn's disease. DESIGN: Prospective multicentre cohort study. SETTING: Eight NHS hospitals. PARTICIPANTS: Consecutive participants aged ≥ 16 years, newly diagnosed with Crohn's disease or with established Crohn's disease and suspected relapse. INTERVENTIONS: Magnetic resonance enterography and ultrasonography. MAIN OUTCOME MEASURES: The primary outcome was per-participant sensitivity difference between magnetic resonance enterography and ultrasonography for small bowel Crohn's disease extent. Secondary outcomes included sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease extent, and sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease presence; identification of active disease; interobserver variation; participant acceptability; diagnostic impact; and cost-effectiveness. RESULTS: Out of the 518 participants assessed, 335 entered the trial, with 51 excluded, giving a final cohort of 284 (133 and 151 in new diagnosis and suspected relapse cohorts, respectively). Across the whole cohort, for small bowel Crohn's disease extent, magnetic resonance enterography sensitivity [80%, 95% confidence interval (CI) 72% to 86%] was significantly greater than ultrasonography sensitivity (70%, 95% CI 62% to 78%), with a 10% difference (95% CI 1% to 18%; p = 0.027). For small bowel Crohn's disease extent, magnetic resonance enterography specificity (95%, 95% CI 85% to 98%) was significantly greater than ultrasonography specificity (81%, 95% CI 64% to 91%), with a 14% difference (95% CI 1% to 27%). For small bowel Crohn's disease presence, magnetic resonance enterography sensitivity (97%, 95% CI 91% to 99%) was significantly greater than ultrasonography sensitivity (92%, 95% CI 84% to 96%), with a 5% difference (95% CI 1% to 9%). For small bowel Crohn's disease presence, magnetic resonance enterography specificity was 96% (95% CI 86% to 99%) and ultrasonography specificity was 84% (95% CI 65% to 94%), with a 12% difference (95% CI 0% to 25%). Test sensitivities for small bowel Crohn's disease presence and extent were similar in the two cohorts. For colonic Crohn's disease presence in newly diagnosed participants, ultrasonography sensitivity (67%, 95% CI 49% to 81%) was significantly greater than magnetic resonance enterography sensitivity (47%, 95% CI 31% to 64%), with a 20% difference (95% CI 1% to 39%). For active small bowel Crohn's disease, magnetic resonance enterography sensitivity (96%, 95% CI 92% to 99%) was significantly greater than ultrasonography sensitivity (90%, 95% CI 82% to 95%), with a 6% difference (95% CI 2% to 11%). There was some disagreement between readers for both tests. A total of 88% of participants rated magnetic resonance enterography as very or fairly acceptable, which is significantly lower than the percentage (99%) of participants who did so for ultrasonography. Therapeutic decisions based on magnetic resonance enterography alone and ultrasonography alone agreed with the final decision in 122 out of 158 (77%) cases and 124 out of 158 (78%) cases, respectively. There were no differences in costs or quality-adjusted life-years between tests. LIMITATIONS: Magnetic resonance enterography and ultrasonography scans were interpreted by practitioners blinded to clinical data (but not participant cohort), which does not reflect use in clinical practice. CONCLUSIONS: Magnetic resonance enterography has higher accuracy for detecting the presence, extent and activity of small bowel Crohn's disease than ultrasonography does. Both tests have variable interobserver agreement and are broadly acceptable to participants, although ultrasonography produces less participant burden. Diagnostic impact and cost-effectiveness are similar. Recommendations for future work include investigation of the comparative utility of magnetic resonance enterography and ultrasonography for treatment response assessment and investigation of non-specific abdominal symptoms to confirm or refute Crohn's disease. TRIAL REGISTRATION: Current Controlled Trials ISRCTN03982913. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 42. See the NIHR Journals Library website for further project information.


Crohn's disease is a waxing and waning lifelong inflammatory condition that affects the colon (large bowel) and small bowel. Treatment relies on accurately determining disease extent and underlying inflammation. Colonoscopy is very good for examining the colon, but it is invasive and, at best, can only visualise a few centimetres of the small bowel, so radiological imaging is very important. Magnetic resonance enterography (a type of magnetic resonance imaging scan) and ultrasonography are both radiological tests commonly performed in the NHS, and it is unclear which method is better. We performed a study to compare the accuracy of magnetic resonance enterography and ultrasonography for determining the extent of Crohn's disease in the bowel of participants newly diagnosed and in those participants with established Crohn's disease but with suspected deterioration. We also investigated how often radiologists agree with each other during test interpretation, the participant experience of undergoing the tests and their cost-effectiveness. We compared the tests in 284 participants (133 newly diagnosed and 151 with suspected deterioration). We found that both tests were accurate for detecting the presence (97% for magnetic resonance enterography and 92% for ultrasonography) and location (80% for magnetic resonance enterography and 70% for ultrasonography) of disease in the small bowel, but magnetic resonance enterography was better than ultrasonography for both (correctly classifying disease extent in 107 more participants for every 1000 participants with Crohn's disease). Magnetic resonance enterography was similarly better than ultrasonography at determining if the bowel was inflamed. The results were similar in newly diagnosed participants and those participants with suspected deterioration. Agreement between radiologists interpreting the same images was, at best, moderate for both tests. A total of 88% of participants tolerated magnetic resonance enterography well or fairly well, which was less than the percentage (99%) of participants who tolerated ultrasonography well or fairly well. Both tests had a similar effect on the treatment decisions made by doctors. Both tests were also similar in their value for money for the NHS.


Assuntos
Análise Custo-Benefício , Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia , Adolescente , Adulto , Feminino , Humanos , Intestino Delgado , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Sensibilidade e Especificidade , Reino Unido , Adulto Jovem
14.
Eur Radiol ; 29(3): 1083-1093, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30128615

RESUMO

OBJECTIVES: To compare patient acceptability and burden of magnetic resonance enterography (MRE) and ultrasound (US) to each other, and to other enteric investigations, particularly colonoscopy. METHODS: 159 patients (mean age 38, 94 female) with newly diagnosed or relapsing Crohn's disease, prospectively recruited to a multicentre diagnostic accuracy study comparing MRE and US completed an experience questionnaire on the burden and acceptability of small bowel investigations between December 2013 and September 2016. Acceptability, recovery time, scan burden and willingness to repeat the test were analysed using the Wilcoxon signed rank and McNemar tests; and group differences in scan burden with Mann-Whitney U and Kruskal-Wallis tests. RESULTS: Overall, 128 (88%) patients rated MRE as very or fairly acceptable, lower than US (144, 99%; p < 0.001), but greater than colonoscopy (60, 60%; p < 0.001). MRE recovery time was longer than US (p < 0.001), but shorter than colonoscopy (p < 0.001). Patients were less willing to undergo MRE again than US (127 vs. 133, 91% vs. 99%; p = 0.012), but more willing than for colonoscopy (68, 75%; p = 0.017). MRE generated greater burden than US (p < 0.001), although burden scores were low. Younger age and emotional distress were associated with greater MRE and US burden. Higher MRE discomfort was associated with patient preference for US (p = 0.053). Patients rated test accuracy as more important than scan discomfort. CONCLUSIONS: MRE and US are well tolerated. Although MRE generates greater burden, longer recovery and is less preferred than US, it is more acceptable than colonoscopy. Patients, however, place greater emphasis on diagnostic accuracy than burden. KEY POINTS: • MRE and US are rated as acceptable by most patients and superior to colonoscopy. • MRE generates significantly greater burden and longer recovery times than US, particularly in younger patients and those with high levels of emotional distress. • Most patients prefer the experience of undergoing US than MRE; however, patients rate test accuracy as more importance than scan burden.


Assuntos
Colonoscopia/métodos , Doença de Crohn/diagnóstico , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Satisfação do Paciente , Ultrassonografia/métodos , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
15.
Lancet Gastroenterol Hepatol ; 3(8): 548-558, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29914843

RESUMO

BACKGROUND: Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. METHODS: We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. FINDINGS: 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72-86]) and presence (97% [91-99]) were significantly greater than that of ultrasound (70% [62-78] for disease extent, 92% [84-96] for disease presence); a 10% (95% CI 1-18; p=0·027) difference for extent, and 5% (1-9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85-98]) was significantly greater than that of ultrasound (81% [64-91]); a difference of 14% (1-27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86-99) with MRE and 84% (65-94) with ultrasound (difference 12% [0-25]; p=0·054). There were no serious adverse events. INTERPRETATION: Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. FUNDING: National Institute of Health and Research Health Technology Assessment.


Assuntos
Doença de Crohn/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Sensibilidade e Especificidade , Adulto Jovem
16.
Health Technol Assess ; 22(7): 1-114, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29402376

RESUMO

BACKGROUND: Pancreatic cancer diagnosis and staging can be difficult in 10-20% of patients. Positron emission tomography (PET)/computed tomography (CT) adds precise anatomical localisation to functional data. The use of PET/CT may add further value to the diagnosis and staging of pancreatic cancer. OBJECTIVE: To determine the incremental diagnostic accuracy and impact of PET/CT in addition to standard diagnostic work-up in patients with suspected pancreatic cancer. DESIGN: A multicentre prospective diagnostic accuracy and clinical value study of PET/CT in suspected pancreatic malignancy. PARTICIPANTS: Patients with suspected pancreatic malignancy. INTERVENTIONS: All patients to undergo PET/CT following standard diagnostic work-up. MAIN OUTCOME MEASURES: The primary outcome was the incremental diagnostic value of PET/CT in addition to standard diagnostic work-up with multidetector computed tomography (MDCT). Secondary outcomes were (1) changes in patients' diagnosis, staging and management as a result of PET/CT; (2) changes in the costs and effectiveness of patient management as a result of PET/CT; (3) the incremental diagnostic value of PET/CT in chronic pancreatitis; (4) the identification of groups of patients who would benefit most from PET/CT; and (5) the incremental diagnostic value of PET/CT in other pancreatic tumours. RESULTS: Between 2011 and 2013, 589 patients with suspected pancreatic cancer underwent MDCT and PET/CT, with 550 patients having complete data and in-range PET/CT. Sensitivity and specificity for the diagnosis of pancreatic cancer were 88.5% and 70.6%, respectively, for MDCT and 92.7% and 75.8%, respectively, for PET/CT. The maximum standardised uptake value (SUVmax.) for a pancreatic cancer diagnosis was 7.5. PET/CT demonstrated a significant improvement in relative sensitivity (p = 0.01) and specificity (p = 0.023) compared with MDCT. Incremental likelihood ratios demonstrated that PET/CT significantly improved diagnostic accuracy in all scenarios (p < 0.0002). PET/CT correctly changed the staging of pancreatic cancer in 56 patients (p = 0.001). PET/CT influenced management in 250 (45%) patients. PET/CT stopped resection in 58 (20%) patients who were due to have surgery. The benefit of PET/CT was limited in patients with chronic pancreatitis or other pancreatic tumours. PET/CT was associated with a gain in quality-adjusted life-years of 0.0157 (95% confidence interval -0.0101 to 0.0430). In the base-case model PET/CT was seen to dominate MDCT alone and is thus highly likely to be cost-effective for the UK NHS. PET/CT was seen to be most cost-effective for the subgroup of patients with suspected pancreatic cancer who were thought to be resectable. CONCLUSION: PET/CT provided a significant incremental diagnostic benefit in the diagnosis of pancreatic cancer and significantly influenced the staging and management of patients. PET/CT had limited utility in chronic pancreatitis and other pancreatic tumours. PET/CT is likely to be cost-effective at current reimbursement rates for PET/CT to the UK NHS. This was not a randomised controlled trial and therefore we do not have any information from patients who would have undergone MDCT only for comparison. In addition, there were issues in estimating costs for PET/CT. Future work should evaluate the role of PET/CT in intraductal papillary mucinous neoplasm and prognosis and response to therapy in patients with pancreatic cancer. STUDY REGISTRATION: Current Controlled Trials ISRCTN73852054 and UKCRN 8166. FUNDING: The National Institute for Health Research Health Technology Assessment programme.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/economia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/diagnóstico por imagem , Análise Custo-Benefício , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Econométricos , Tomografia Computadorizada Multidetectores/economia , Tomografia Computadorizada Multidetectores/métodos , Estadiamento de Neoplasias , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Pancreatite Crônica/diagnóstico , Pancreatite Crônica/patologia , Estudos Prospectivos , Anos de Vida Ajustados por Qualidade de Vida , Sensibilidade e Especificidade , Medicina Estatal , Reino Unido , Adulto Jovem
17.
Cardiovasc Intervent Radiol ; 41(4): 645-652, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29344711

RESUMO

PURPOSE: Central venous access in children, in particular small children and infants, is challenging. We have developed a technique employing adult peripherally inserted central venous catheters (PICCs) as tunnelled central venous catheters (TCVCs) in children. The principal advantage of this novel technique is that the removal technique is less complex than that of conventional cuffed TCVCs. The catheter can be removed simply by being pulled out and does not require general anaesthesia. The purpose of this study is to determine the success, safety and utility of this technique and to identify the rate of late complications. We describe the 6-year experience in our unit. MATERIALS AND METHODS: Electronic and paper medical records were reviewed for consecutive paediatric patients who had a PICC device inserted as a TCVC over a 6-year period (September 2009 through July 2015). The following data were recorded-patient demographics, setting for PICC as TCVC insertion, use of ultrasound and fluoroscopy, PICC device type, early or late complications and date of and reason for removal. RESULTS: Twenty-one PICCs were inserted as TCVCs in 19 children, all aged less than 10 years. Mean patient age at the time of placement was 3.7 years. Average patient weight was 15.7 kg. All insertions were successful with no significant immediate complications recorded. The most common indication for insertion in our patient sample was pseudo-obstruction secondary to gastrointestinal dysmotility disorder (24%), with cystic fibrosis infective exacerbation being the second most frequent diagnosis (14%). Suspected catheter-related infection led to early device removal in one case (4.8%). Inadvertent dislodgement occurred in one case (4.8%). Nineteen of the 21 devices (90.4%) lasted for the total intended duration of use. CONCLUSION: Using a PICC device as a TCVC in small children appears to be a safe technique, with an acceptable complication profile.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/métodos , Cateterismo Periférico/instrumentação , Cateteres Venosos Centrais , Cateteres de Demora , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
18.
Nephrol Dial Transplant ; 33(10): 1751-1756, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29237046

RESUMO

Background: Iodinated contrast media (CM) used in angiography and computed tomography (CT) scans is an important cause of acute kidney injury (AKI) in hospitalized patients undergoing surgery. Contrast-induced nephropathy leads to AKI soon after CM administration. The aim of the study was to determine whether the timing of contrast media exposure related to diagnostic imaging during the immediate perioperative period influences the risk of post-operative AKI. Methods: All patients aged 18 years or above who underwent diagnostic imaging within 7 days of non-cardiac surgery between 1 January 2003 and 31 December 2013 in the Tayside region of Scotland, UK were included in the analysis. The primary outcome of AKI was defined using the Kidney Disease: Improving Global Outcomes creatinine-based criteria. Multiple logistic regressions were performed to identify predictors for AKI. Results: Of 9300 patients, 6224 were exposed to CM in the immediate perioperative period and 3076 were not. Post-operative AKI occurred in 678 (10.9%) of the 6224 patients who were exposed to CM. On multiple logistic regression, independent predictors of post-operative AKI were increasing age, male gender, lower baseline renal function and treatment with angiotensin-converting enzyme inhibitors or angiotensin receptor blockers. Timing of CM exposure did not affect risk of developing AKI, odds ratio 0.972 (95% confidence interval 0.935-1.010), P = 0.146. Conclusions: For patients who have either just had or are soon to undergo general surgical procedures there appears to be no need to limit CT scan quality by avoiding the administration of CM. These patients may benefit from the increased diagnostic utility of contrast-enhanced CT scans without increasing their risk of perioperative AKI.


Assuntos
Injúria Renal Aguda/etiologia , Meios de Contraste/efeitos adversos , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Injúria Renal Aguda/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Perioperatório , Fatores de Risco , Escócia
20.
Radiographics ; 35(4): 1077-90, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26172352

RESUMO

High-resolution magnetic resonance (MR) imaging performed with a microscopy coil is a robust radiologic tool for the evaluation of skin lesions. Microscopy-coil MR imaging uses a small surface coil and a 1.5-T or higher MR imaging system. Simple T1- and T2-weighted imaging protocols can be implemented to yield high-quality, high-spatial-resolution images that provide an excellent depiction of dermal anatomy. The primary application of microscopy-coil MR imaging is to delineate the deep margins of skin tumors, thereby providing a preoperative road map for dermatologic surgeons. This information is particularly useful for surgeons who perform Mohs micrographic surgery and in cases of nasofacial neoplasms, where the underlying anatomy is complex. Basal cell carcinoma is the most common nonmelanocytic skin tumor and has a predilection to manifest on the face, where it can be challenging to achieve complete surgical excision while preserving the cosmetic dignity of the patient. Microscopy-coil MR imaging provides dermatologic surgeons with valuable preoperative anatomic information that is not available at conventional clinical examination.


Assuntos
Dermoscopia/instrumentação , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Microscopia/instrumentação , Imagem Multimodal/instrumentação , Neoplasias Cutâneas/patologia , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...