Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Digit Imaging ; 24(1): 11-27, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19826872

RESUMO

A fully automated and three-dimensional (3D) segmentation method for the identification of the pulmonary parenchyma in thorax X-ray computed tomography (CT) datasets is proposed. It is meant to be used as pre-processing step in the computer-assisted detection (CAD) system for malignant lung nodule detection that is being developed by the Medical Applications in a Grid Infrastructure Connection (MAGIC-5) Project. In this new approach the segmentation of the external airways (trachea and bronchi), is obtained by 3D region growing with wavefront simulation and suitable stop conditions, thus allowing an accurate handling of the hilar region, notoriously difficult to be segmented. Particular attention was also devoted to checking and solving the problem of the apparent 'fusion' between the lungs, caused by partial-volume effects, while 3D morphology operations ensure the accurate inclusion of all the nodules (internal, pleural, and vascular) in the segmented volume. The new algorithm was initially developed and tested on a dataset of 130 CT scans from the Italung-CT trial, and was then applied to the ANODE09-competition images (55 scans) and to the LIDC database (84 scans), giving very satisfactory results. In particular, the lung contour was adequately located in 96% of the CT scans, with incorrect segmentation of the external airways in the remaining cases. Segmentation metrics were calculated that quantitatively express the consistency between automatic and manual segmentations: the mean overlap degree of the segmentation masks is 0.96 ± 0.02, and the mean and the maximum distance between the mask borders (averaged on the whole dataset) are 0.74 ± 0.05 and 4.5 ± 1.5, respectively, which confirms that the automatic segmentations quite correctly reproduce the borders traced by the radiologist. Moreover, no tissue containing internal and pleural nodules was removed in the segmentation process, so that this method proved to be fit for the use in the framework of a CAD system. Finally, in the comparison with a two-dimensional segmentation procedure, inter-slice smoothness was calculated, showing that the masks created by the 3D algorithm are significantly smoother than those calculated by the 2D-only procedure.


Assuntos
Algoritmos , Neoplasias Pulmonares/diagnóstico , Pulmão/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
2.
Rays ; 30(3): 221-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16512067

RESUMO

The case of a female patient admitted to the hospital for a syncopal episode characterized by mental confusion, retrograde amnesia, agnosia, lack of sphincter control and behavior disorders, is presented. Cranial CT showed a frontal bihemispheric lesion. MRI completed with DWI was then performed to better define the nature of the lesion and for an in-depth diagnostic study. The diagnostic role of conventional MRI combined with DWI and the importance of the latter in the differential diagnosis between primary central nervous system lymphoma (confirmed at histology) and glioblastoma multiforme is discussed.


Assuntos
Neoplasias Encefálicas/diagnóstico , Linfoma/diagnóstico , Neoplasias Encefálicas/diagnóstico por imagem , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética , Feminino , Glioblastoma/diagnóstico , Glioblastoma/diagnóstico por imagem , Humanos , Linfoma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...