Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 141: 187-192, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29555377

RESUMO

Conventional radiotherapy is mainly applied by linear accelerators. Although linear accelerators provide dual (electron/photon) radiation beam modalities, both of them are intrinsically produced by a megavoltage electron current. Modern radiotherapy treatment techniques are based on suitable devices inserted or attached to conventional linear accelerators. Thus, precise control of delivered beam becomes a main key issue. This work presents an integral description of electron beam deflection control as required for novel radiotherapy technique based on convergent photon beam production. Theoretical and Monte Carlo approaches were initially used for designing and optimizing device´s components. Then, dedicated instrumentation was developed for experimental verification of electron beam deflection due to the designed magnets. Both Monte Carlo simulations and experimental results support the reliability of electrodynamics models used to predict megavoltage electron beam control.


Assuntos
Elétrons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Simulação por Computador , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/estatística & dados numéricos
2.
Int Endod J ; 36(4): 262-6, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12702120

RESUMO

AIM: To evaluate the effect of rotational speed and the angle and radius of curvature of root canals on the fracture of two types of nickel-titanium rotary instruments: K3 and ProTaper. METHODOLOGY: A total of 240 root canals of extracted human maxillary and mandibular molars were divided into two groups of 120, according to the angle of the canal curvature (group A: <30 degrees, group B: >30 degrees). Each group was then divided into two subgroups of 60 canals in order to perform instrumentation using K3 and ProTaper rotary instruments at three different rotational speeds: 150, 250 and 350 r.p.m. (20 canals at each rotational speed). Each instrument was used a maximum of 20 times and at one rotational speed only. The angle and radius of canal curvature were measured in the only group in which fractures actually took place (group B). RESULTS: There were a total of 22 instrument fractures; all of these occurred in canals with curves >30 degree. In a multivariate analysis, it was demonstrated that the files used at a rotational speed of 350 r.p.m. were more likely to fracture than those used at 250 r.p.m. (OR: 1113.88; 95% CI: 2.36-526420.05) and than those used at 150 r.p.m. (OR: 13531.33; 95% CI: 5.37-34120254.00). A decrease in the angle of curvature of the canal also significantly reduced the likelihood of fracture (OR: 0.2083; 95% CI: 0.068-0.6502). These relationships remained significant after being adjusted for the potential interactions between the remaining variables. No significant differences were found between the files or the radii of the canals. CONCLUSIONS: Instrument fracture was associated with rotational speed and the angle of curvature of the canal.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Ligas Dentárias , Cavidade Pulpar/anatomia & histologia , Análise do Estresse Dentário , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Modelos Logísticos , Dente Molar , Análise Multivariada , Níquel , Odontometria , Maleabilidade , Preparo de Canal Radicular/métodos , Titânio , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...