Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Invest Ophthalmol Vis Sci ; 63(9): 32, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-36036910

RESUMO

Purpose: To investigate the ocular surface microbiome of patients with unilateral or asymmetric glaucoma being treated with topical ophthalmic medications in one eye and to determine whether microbial community changes were related to measures of ocular surface disease. Methods: V3-V4 16S rRNA sequencing was conducted on ocular surface swabs collected from both eyes of 17 subjects: 10 patients with asymmetric/unilateral glaucoma using topical glaucoma therapy on only one eye and seven age-matched, healthy controls with no history of ocular disease or eyedrop use. Samples were categorized into three groups: patients' glaucomatous eye treated with eyedrops, patients' contralateral eye without eyedrops, and healthy control eyes. Comparisons were made for microbial diversity and composition, with differences in composition tested for association with ocular surface disease measures including tear meniscus height, tear break-up time, and Dry Eye Questionnaire. Results: Samples obtained from the patients' treated and untreated eyes both had significantly greater alpha-diversity and relative abundance of gram-negative organisms compared to healthy controls. The microbial composition of patient eyes was associated with decreased tear meniscus height and tear break-up time, whereas metagenomic predictions, based on 16S rRNA data, suggested increased synthesis of lipopolysaccharide. Conclusions: The ocular surface microbiome of patients taking unilateral preserved glaucoma drops is characterized by a highly diverse array of gram-negative bacteria that is significantly different from the predominantly gram-positive microbes detected on healthy control eyes. These compositional differences were associated with decreased tear film measures and distinct inferred protein synthesis pathways, suggesting a potential link between microbial alterations and ocular surface inflammation.


Assuntos
Síndromes do Olho Seco , Glaucoma , Microbiota , Anti-Hipertensivos/uso terapêutico , Síndromes do Olho Seco/tratamento farmacológico , Síndromes do Olho Seco/metabolismo , Glaucoma/tratamento farmacológico , Glaucoma/metabolismo , Humanos , Soluções Oftálmicas/uso terapêutico , RNA Ribossômico 16S/genética , RNA Ribossômico 16S/metabolismo , Lágrimas/metabolismo
2.
Ophthalmic Plast Reconstr Surg ; 37(3S): S92-S97, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32890120

RESUMO

PURPOSE: To describe a reversible syndrome of epiphora, functional punctal stenosis, and chronic pretarsal conjunctivitis associated with corticosteroid or corticosteroid-antibiotic eyedrop use. METHODS: This is an Institutional Review Board-approved retrospective review of patients diagnosed with epiphora, punctal stenosis, and chronic conjunctivitis by a single surgeon (B.J.W.). These patients were subsequently invited to participate in a prospective study involving allergy skin patch testing for ophthalmic drops, common excipients, and active ingredients. RESULTS: Thirteen patients received a diagnosis of punctal congestion syndrome. The average age was 63 years (range, 41-93) and 69.2% were female. Findings were bilateral in 61.5%. All had used preserved drops in the affected eye(s). Various antecedent diagnoses resulted in treatment with preserved drops. Patients experienced epiphora for an average of 3.8 months (median, 3 months; mode, 3 months; range, 1-8 months) prior to presentation. Two patients had undergone punctoplasty which failed to resolve symptoms. 92.3% of patients had been taking tobramycin-dexamethasone drops, loteprednol drops, or a combination of both prior to presentation. All were taken off preserved drops. 69.2% were also treated with a preservative-free loteprednol etabonate 0.5% ophthalmic ointment taper. All improved. Partial relief of symptoms was achieved by an average of 1.6 months (median, 2 months; mode, 2 months; standard deviation, ±0.7 months) and resolution of symptoms by 2.5 months (median, 2 months; mode, 2 months; standard deviation, ±1.7 months). One patient underwent patch testing with strong positive reactions to formaldehyde and neomycin and a weak positive reaction to gentamicin. CONCLUSIONS: Functional punctal stenosis is associated with topical ophthalmic preparations, especially preserved corticosteroids and antibiotic-corticosteroid combinations. Treatment consists of removal of all preserved eyedrops. Symptoms often improve over several months.


Assuntos
Conjuntivite , Obstrução dos Ductos Lacrimais , Constrição Patológica , Feminino , Humanos , Obstrução dos Ductos Lacrimais/diagnóstico , Obstrução dos Ductos Lacrimais/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
3.
Optom Vis Sci ; 96(2): 137-141, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30601362

RESUMO

SIGNIFICANCE: Given that there are few reported cases of lecithin:cholesterol acyltransferase (LCAT) deficiency, recognition of the condition with proper management is notable. Long-term follow-up and contact lens fitting after penetrating keratoplasty provide best possible outcomes. PURPOSE: The purpose of this study was to report a case of LCAT deficiency successfully treated with penetrating keratoplasty and longer-term follow-up with contact lens fitting. CASE REPORT: A 43-year-old white woman of Italian descent presented with corneal clouding and trouble with night vision. The patient had a history of LCAT deficiency, irritable bowel syndrome, gastroesophageal reflux disease, osteoporosis, and hemolytic anemia. Slit-lamp examination demonstrated corneal haze throughout the corneal layers. The corneas had normal pachymetry. Given the opacity of each cornea (right greater than left) and decreased night vision, penetrating keratoplasty was performed on the right eye. At post-operative month 16, the corneal graft remained clear. The patient was able to achieve a best-corrected visual acuity of 20/30+ with a scleral lens. CONCLUSIONS: Penetrating keratoplasty may be necessary to provide better quality of vision in LCAT deficiency patients, specifically to enhance one's contrast sensitivity, despite relatively good Snellen visual acuity.


Assuntos
Opacidade da Córnea/etiologia , Opacidade da Córnea/cirurgia , Ceratoplastia Penetrante , Deficiência da Lecitina Colesterol Aciltransferase/complicações , Adulto , Sensibilidades de Contraste/fisiologia , Opacidade da Córnea/diagnóstico , Paquimetria Corneana , Feminino , Humanos , Deficiência da Lecitina Colesterol Aciltransferase/diagnóstico , Acuidade Visual/fisiologia
4.
J Cataract Refract Surg ; 44(8): 993-1002, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30115299

RESUMO

PURPOSE: To characterize changes in densitometry after corneal crosslinking (CXL) and correlate it with visual outcomes. SETTING: Tertiary referral academic medical center, New York, New York, USA. DESIGN: Retrospective case series. METHODS: Patients with progressive keratoconus or post-laser in situ keratomileusis ectasia had CXL following the Dresden protocol. The corrected distance visual acuity (CDVA) and Pentacam imaging were obtained at baseline and follow-up visits. RESULTS: Fifty-seven patients were followed for a mean of 15 months (range 1 to 24 months) after CXL. The CDVA improved significantly from baseline to 6, 12, 18, and 24 months postoperatively. The change in densitometry of the mid-stromal layer, 2.0 to 6.0 mm annulus, at 6 months was correlated with the improvement in CDVA at 6, 12, and 24 months (all P < .10). The increase in densitometry of the mid-stromal layer, centermost 0.0 to 2.0 mm annulus, at 6 months was significantly associated with the decrease in maximum keratometry (K) at 6 and 12 months (both P < .05). Last, the change in densitometry at 6 months was significantly correlated with the decrease in specific higher-order aberrations (HOAs) (P < .05). CONCLUSIONS: Although the greatest and most durable post-CXL densitometry change was in the anterior layer, the degree of increased densitometry haze in the mid-stromal layer was most associated with and possibly predictive of improvement in CDVA, maximum K, and HOAs. The persistence of corneal haze at 6 months, measured by increased densitometry, might be a prognostic marker for CXL effectiveness.


Assuntos
Substância Própria/fisiopatologia , Densitometria/métodos , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Adulto , Idoso , Colágeno/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Feminino , Humanos , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fármacos Fotossensibilizantes/uso terapêutico , Valor Preditivo dos Testes , Estudos Retrospectivos , Riboflavina/uso terapêutico , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...