Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 88(1): 015106, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147658

RESUMO

Malfunctions of the Marx pre-fire or in the event that the main switch does not close were analyzed. Principles of the diverter system for protection of those events were introduced in detail. A 2.6 MV diverter system, consisting of an oil trigger switch and a Marx-coupled trigger generator, was developed. Based on "JianGuang-I" facility, a diverter-system test stand was established. And experiments with 2.3-MV working voltages were carried out to study the performance of this diverter system. Experiment results show that the time delay of this diverter system (from the beginning of the Marx erection to the time that the diverter-switch closes) is about 320 ns and its jitter (standard deviation) is about 8.9 ns. This diverter system has been tested more than 180 shots, and no problem has been encountered yet.

2.
Rev Sci Instrum ; 87(10): 104708, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27802761

RESUMO

Coupled by the Marx of the "JianGuang-I" facility, a high voltage, low time-delay trigger generator was developed. Working principles of this trigger generator and its key issues were described in detail. Structures of this generator were also carefully designed and optimized. Based on the "JianGuang-I" Marx generator, a test stand was established. And a series of experiment tests were carried out to the study performance of this trigger generator. Experiment results show that the output voltage of this trigger generator can be continuously adjusted from 58 kV to 384 kV. The time delay (from the beginning of the Marx-discharging pulse to the time that the output pulse of the trigger generator arises) of this trigger pulse is about 200 ns and its peak time (0%∼100%) is less than 50 ns. Experiment results also indicate that the time-delay jitter of trigger voltages decreases rapidly with the increase in the peak voltage of trigger pulses. When the trigger voltage is higher than 250 kV, the time-delay jitters (the standard deviation) are less than 7.7 ns.

3.
Rev Sci Instrum ; 85(8): 083506, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25173268

RESUMO

Low voltage pulse injection tests have been done on a 1 MV prototype induction cell. The tests mainly aim at measuring azimuthal uniformity of feed currents and evaluating cell electrical parameters. Tests are conducted under two cases that the cell is fed by a single pulse and two pulses, respectively. The results indicate that, in the case of the single-point feed, the best current uniformity with an azimuthal variation of 19.3% is acquired when azimuthal lines connect to cathode plates with lower half circumferences. In the case of two-pulse synchronous feed, the current uniformity becomes better, and a current with an azimuthal variation of 11.8% is achieved. Moreover, the effects of asynchronous feed on current uniformity are also experimentally investigated. The results imply that, for given injecting pulses with the duration of 70-80 ns, a time deviation less than 30 ns could be acceptable, without obvious degradation on the feed uniformity and current addition. In addition, the influences of the current uniformity and amounts of feed pulses on cell equivalent inductances are evaluated. The experiment results show that, the equivalent inductance would nearly keep a value of 130 nH as the current variation is less than 50%. However, the extreme asymmetry of feed currents or the increase of amounts of feed pulses would produce additional inductance.

4.
Rev Sci Instrum ; 81(3): 034703, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20370204

RESUMO

A new style high voltage resistor divider made of saline solution has been constructed and tested. A coaxial construction is used on the low-voltage arm, as the signal extraction electrode, which can increase the attenuation ratio of the divider. The time response of divider limited by the stray parameter also can be improved. Comparing the results of calibrated experiment with the commonly used equal size copper sulfate dividers, the new probe has nearly five times increase in the attenuation ratio. The time response of the new style divider in the dimension of 30 mm in diameter and 400 mm in length can reach to 1 ns.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...