Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhonghua Nei Ke Za Zhi ; 63(5): 439-461, 2024 May 01.
Artigo em Chinês | MEDLINE | ID: mdl-38715481

RESUMO

The evolution of critical care medicine is inextricably linked to the development of critical care procedures. These procedures not only facilitate diagnosis and treatment of critically ill patients, but also provide valuable insights into disease pathophysiology. While critical care interventions offer undeniable benefits, the potential for iatrogenic complications necessitates careful consideration. The recent surge in critical care ultrasound (US) utilization is a testament to its unique advantages: non-invasiveness, real-time bedside availability, direct visualization of internal structures, elimination of ionizing radiation exposure, repeatability, and relative ease of learning. Recognizing the need to optimize procedures and minimize complications, critical care utrasound study group of Beijing critical care ultrasound research assocition convened a panel of critical care experts to generate this consensus statement. This document serves as a guide for healthcare providers, aiming to ensure patient safety and best practices in critical care.


Assuntos
Cuidados Críticos , Ultrassonografia , Humanos , Cuidados Críticos/métodos , Ultrassonografia/métodos , Consenso
2.
Phys Rev Lett ; 128(24): 242502, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35776479

RESUMO

The isomer depletion of ^{93m}Mo was recently reported [Chiara et al., Nature (London) 554, 216 (2018)NATUAS0028-083610.1038/nature25483] as the first direct observation of nuclear excitation by electron capture (NEEC). However, the measured excitation probability of 1.0(3)% is far beyond the theoretical expectation. In order to understand the inconsistency between theory and experiment, we produce the ^{93m}Mo nuclei using the ^{12}C(^{86}Kr,5n) reaction at a beam energy of 559 MeV and transport the reaction residues to a detection station far away from the target area employing a secondary beam line. The isomer depletion is expected to occur during the slowdown process of the ions in the stopping material. In such a low γ-ray background environment, the signature of isomer depletion is not observed, and an upper limit of 2×10^{-5} is estimated for the excitation probability. This is consistent with the theoretical expectation. Our findings shed doubt on the previously reported NEEC phenomenon and highlight the necessity and feasibility of further experimental investigations for reexamining the isomer depletion under low γ-ray background.

3.
Zhonghua Nei Ke Za Zhi ; 57(6): 397-417, 2018 Jun 01.
Artigo em Chinês | MEDLINE | ID: mdl-29925125

RESUMO

Critical ultrasonography(CUS) is different from the traditional diagnostic ultrasound, the examiner and interpreter of the image are critical care medicine physicians. The core content of CUS is to evaluate the pathophysiological changes of organs and systems and etiology changes. With the idea of critical care medicine as the soul, it can integrate the above information and clinical information, bedside real-time diagnosis and titration treatment, and evaluate the therapeutic effect so as to improve the outcome. CUS is a traditional technique which is applied as a new application method. The consensus of experts on critical ultrasonography in China released in 2016 put forward consensus suggestions on the concept, implementation and application of CUS. It should be further emphasized that the accurate and objective assessment and implementation of CUS requires the standardization of ultrasound image acquisition and the need to establish a CUS procedure. At the same time, the standardized training for CUS accepted by critical care medicine physicians requires the application of technical specifications, and the establishment of technical specifications is the basis for the quality control and continuous improvement of CUS. Chinese Critical Ultrasound Study Group and Critical Hemodynamic Therapy Collabration Group, based on the rich experience of clinical practice in critical care and research, combined with the essence of CUS, to learn the traditional ultrasonic essence, established the clinical application technical specifications of CUS, including in five parts: basic view and relevant indicators to obtain in CUS; basic norms for viscera organ assessment and special assessment; standardized processes and systematic inspection programs; examples of CUS applications; CUS training and the application of qualification certification. The establishment of applied technology standard is helpful for standardized training and clinical correct implementation. It is helpful for clinical evaluation and correct guidance treatment, and is also helpful for quality control and continuous improvement of CUS application.


Assuntos
Cuidados Críticos/métodos , Hemodinâmica , Médicos , Ultrassonografia/métodos , China , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...