Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 216
Filtrar
1.
Front Cardiovasc Med ; 11: 1328906, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596690

RESUMO

Background: Understanding complex cardiac anatomy is essential for percutaneous left atrial appendage (LAA) closure. Conventional multi-slice computed tomography (MSCT) and transesophageal echocardiography (TEE) are now supported by advanced 3D printing and virtual reality (VR) techniques for three-dimensional visualization of volumetric data sets. This study aimed to investigate their added value for LAA closure procedures. Methods: Ten patients scheduled for interventional LAA closure were evaluated with MSCT and TEE. Patient-specific 3D printings and VR models were fabricated based on MSCT data. Ten cardiologists then comparatively assessed LAA anatomy and its procedure relevant surrounding structures with all four imaging modalities and rated their procedural utility on a 5-point Likert scale questionnaire (from 1 = strongly agree to 5 = strongly disagree). Results: Device sizing was rated highest in MSCT (MSCT: 1.9 ± 0.8; TEE: 2.6 ± 0.9; 3D printing: 2.5 ± 1.0; VR: 2.5 ± 1.1; p < 0.01); TEE, VR, and 3D printing were superior in the visualization of the Fossa ovalis compared to MSCT (MSCT: 3.3 ± 1.4; TEE: 2.2 ± 1.3; 3D printing: 2.2 ± 1.4; VR: 1.9 ± 1.3; all p < 0.01). The major strength of VR and 3D printing techniques was a superior depth perception (VR: 1.6 ± 0.5; 3D printing: 1.8 ± 0.4; TEE: 2.9 ± 0.7; MSCT: 2.6 ± 0.8; p < 0.01). The visualization of extracardiac structures was rated less accurate in TEE than MSCT (TEE: 2.6 ± 0.9; MSCT: 1.9 ± 0.8, p < 0.01). However, 3D printing and VR insufficiently visualized extracardiac structures in the present study. Conclusion: A true 3D visualization in VR or 3D printing provides an additional value in the evaluation of the LAA for the planning of percutaneous closure. In particular, the superior perception of depth was seen as a strength of a 3D visualization. This may contribute to a better overall understanding of the anatomy. Clinical studies are needed to evaluate whether a more comprehensive understanding through advanced multimodal imaging of patient-specific anatomy using VR may translate into improved procedural outcomes.

2.
Interv Cardiol ; 19: e01, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38464494

RESUMO

Optimised implantation depth (OID) is crucial to obtain the best haemodynamic and clinical outcome during transcatheter heart valve (THV) deployment. OID ensures a better haemodynamic profile and is associated with a potential reduction in permanent pacemaker implantations, both of which are important during transcatheter aortic valve replacement (TAVR). Apart from patient-related anatomic conditions, many factors, such as THV and wire selection, as well as implantation strategies, can be controlled by the operator and facilitate the implantation process. However, there are only limited data dealing with predictors for OID. Therefore, the aim of this review was to outline factors and tools that might influence the final implantation depth during TAVR procedures, potentially influencing the outcome.

3.
J Cardiovasc Dev Dis ; 11(3)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38535105

RESUMO

Due to the complex and variable anatomy of the left atrial appendage, percutaneous left atrial appendage closure (LAAC) can be challenging. In this study, we investigated the impact of fusion imaging (FI) on the LAAC learning curve of two interventionalists. The first interventionalist (IC 1) was initially trained without FI and continued his training with FI. The second interventionalist (IC 2) performed all procedures with FI. We compared the first 36 procedures without FI of IC 1 (group 1) with his next 36 interventions with FI (group 2). Furthermore, group 1 was compared to 36 procedures of IC 2 who directly started his training with FI (group 3). Group 1 demonstrated that the learning curve without FI has a flat course with weak correlations for fluoroscopy time, contrast volume, and procedure time, but not for dose area product. Group 2 with FI showed improvement with a steep course and strong correlations for all four parameters. In group 3, we also saw a steep progression with strong correlations. Furthermore, the mean measurements of the parameters in the groups with FI decreased significantly as an indicator of procedural efficacy. We demonstrated that FI may improve the learning curve of experienced and non-experienced ICs.

4.
J Invasive Cardiol ; 36(1)2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38224296

RESUMO

OBJECTIVES: Dynamic Coronary Roadmap (DCR) is a software tool that creates a real-time dynamic coronary artery overlay on fluoroscopic images. The efficacy of DCR in significantly reducing contrast medium use during percutaneous coronary interventions (PCI) has previously been shown. In this study, we aimed to determine if DCR is equally effective irrespective of the performing investigator's experience level. METHODS: In this sub-analysis of a monocentric, open-label, randomized trial, 130 patients with hemodynamic relevant coronary type A and B lesions were randomized and contrast medium use was conducted with (+) or without (-) DCR software. PCI was randomly allocated and performed by an investigator with high (A) or medium (B) experience level. RESULTS: Overall, contrast medium use was significantly reduced by both investigators in the +DCR group, and Investigator B used significantly less contrast medium with the software than Investigator A. The DCR software was not accompanied by increased radiation exposure for the patients or the teams. On the contrary, dose area product was reduced by both investigators, but was significantly reduced by the highly experienced investigator when using DCR. Fluoroscopy time was not different between investigators. Procedural success was 100%. Serious in-hospital adverse events were not observed. One of Investigator A's patients suffered from post-procedural acute kidney injury in the -DCR group. CONCLUSIONS: DCR significantly reduces contrast medium use during PCI irrespective of investigator's experience level.


Assuntos
Injúria Renal Aguda , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Diagnóstico por Imagem , Vasos Coronários , Coração , Meios de Contraste/efeitos adversos
5.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38276659

RESUMO

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

6.
Clin Res Cardiol ; 113(1): 107-115, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37524838

RESUMO

BACKGROUND: Many patients in need for transcatheter aortic valve implantation (TAVI) present with an aortic annulus size larger than recommended by the manufacturer's instructions for use (IFU). AIMS: To investigate procedural and short-term safety and efficacy of TAVI in patients with extra-large annuli (ELA). METHODS: 30-day clinical outcome and valve performance as defined by VARC 3 of 144 patients with an aortic annulus size exceeding the permitted range were compared to a propensity-score matched control cohort of patients with an aortic annulus size consistent with the IFU. RESULTS: Area and perimeter was 730.4 ± 53.9 mm2 and 96.7 ± 6.5 mm in the ELA group. Technical (96.5% vs. 94.4%) and device success (82.3% vs. 84.5%) were comparable in patients with ELA (annulus area 730.4 ± 53.9 mm2) and matched controls (annulus area 586.0 ± 48.2 mm2). There was no significant difference in 30-day mortality rate, major intraprocedural complications, type 3 or 4 bleedings, major vascular complications, or stroke. Moderate paravalvular leakage (PVL) occurred more frequent in the ELA group (8.9% vs 2.2%; p = 0.02). The rate of new pacemaker implantation was 7.0% in the ELA cohort and 15.0% in the control cohort, respectively (p = 0.05). CONCLUSION: Treatment of ELA patients with third-generation TAVI prostheses is feasible and safe, providing similar device success and complication rates as in matched controls with regular-sized aortic annulus. Post-interventional pacemaker implantation rates were low compared to the control group, yet incidence of moderate PVL remains problematic in ELA patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Desenho de Prótese , Resultado do Tratamento
7.
Int J Cardiol ; 399: 131690, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38160912

RESUMO

BACKGROUND: Impella™ is increasingly used in cardiogenic shock. However, thromboembolic and bleeding events are frequent during percutaneous mechanical circulatory support (pMCS). OBJECTIVE: Therefore, we aimed to explore the optimal anticoagulation regime for pMCS to prevent thromboembolism and bleedings. METHODS: This hypothesis-generating multi-center cohort study investigated 170 patients with left-Impella™ support. We (A) compared bleeding/thrombotic events in two centers with therapeutic range (TR-aPTT) activated partial thromboplastin time (60-80s) and (B) compared events of these centers with one center with intermediate range aPTT (40-60s). RESULTS: After matching, there were no differences in patients' characteristics. In centers aiming at TR-aPTT, major bleeding was numerically lower with aPTT <60s within 48 h of left-Impella™ support, versus patients that achieved the aimed aPTT of ≥60s [aPTT ≥60s: 22 (37.3%) vs. aPTT<60s 14 (23.7%); Hazard ratio [HR], 0.62 (95%) CI, 0.28-1.38; p = 0.234]. Major cardiovascular and cerebrovascular adverse events (MACCE) did not differ between groups. In comparison of centers, TR-aPTT strategy showed higher major bleeding rates [TR: 8 (47.1%) vs. intermediate range: 1 (5.9%); HR, 0.06 (95%) CI, 0.01-0.45; p = 0.006]. MACCE were lower in the intermediate range aPTT group as well [TR 12 (70.6%) vs. intermediate range 5 (29.4%) HR, 0.32 (95%) CI, 0.11-0.92; p = 0.034]. CONCLUSION: This pilot analysis showed that lowering UFH-targets in left-Impella™ supported CS patients seems to be a safe and promising strategy for reducing major bleedings without increasing MACCE. This needs to be validated in larger, randomized clinical trials.


Assuntos
Heparina , Tromboembolia , Humanos , Anticoagulantes , Choque Cardiogênico/diagnóstico , Estudos de Coortes , Tempo de Tromboplastina Parcial , Hemorragia/induzido quimicamente , Hemorragia/diagnóstico , Tromboembolia/induzido quimicamente , Estudos Retrospectivos
9.
Front Cardiovasc Med ; 10: 1188571, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727301

RESUMO

Background and aims: The complex and highly variable three-dimensional anatomy of the left atrial appendage (LAA) makes planning and device sizing for interventional occlusion procedures (LAAC) challenging. Several imaging modalities [e.g. echocardiography, multi-slice computed tomography (MSCT)] are used for this purpose. Virtual reality (VR) is an emerging imaging technique to immerse into a three-dimensional left atrium and appendage, offering unprecedented options of visualization and measurement. This study aimed to investigate the feasibility, accuracy and reproducibility of visualizing the LAA in VR for preprocedural planning of LAAC. Methods and results: Twenty-one patients (79 ± 7 years, 62% male) who underwent LAAC at University Hospital Düsseldorf were included in our study. A dedicated software generated three-dimensional VR models from preprocedural MSCT imaging data. Conventional measurements of LAA dimensions (ostium, landing zone and depth) using a commercially available software were compared to measurements in VR: MSCT and VR ostium min. (r = 0.93), max. (r = 0.80) and mean (r = 0.88, all p < 0.001) diameters as well as landing zone (LZ) min. (r = 0.84), max. (r = 0.86) and mean diameters (r = 0.90, all p < 0.001) showed strong correlations. Three-dimensional orientation was judged superior by physicians in VR compared to MSCT (p < 0.05). Conclusion: Virtual reality visualization of the left atrium and appendage based on MSCT data is feasible and allows precise and reproducible measurements in planning of LAA occlusion procedures with enhanced 3D orientation. Further studies need to explore additional benefits of three-dimensional visualization for operators in preprocedural planning.

10.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480891

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Incidência , Bloqueio de Ramo , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
12.
Clin Res Cardiol ; 112(12): 1790-1799, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37294311

RESUMO

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) is associated with adverse outcomes, i.e. ischemic stroke or systemic embolism (SE). Data on predictors of stroke/SE in the context of DRT are limited. AIMS: This study aimed to identify predisposing factors for stroke/SE in DRT patients. In addition, the temporal connection of stroke/SE to DRT diagnosis was analyzed. METHODS: The EUROC-DRT registry included 176 patients, in whom DRT after LAAC were diagnosed. Patients with symptomatic DRT, defined as stroke/SE in the context of DRT diagnosis, were compared against patients with non-symptomatic DRT. Baseline characteristics, anti-thrombotic regimens, device position, and timing of stroke/SE were compared. RESULTS: Stroke/SE occurred in 25/176 (14.2%) patients diagnosed with DRT (symptomatic DRT). Stroke/SE occurred after a median of 198 days (IQR 37-558) after LAAC. In 45.8% stroke/SE occurred within one month before/after DRT diagnosis (DRT-related stroke). Patients with symptomatic DRT had lower left ventricular ejection fractions (50.0 ± 9.1% vs. 54.2 ± 11.0%, p = 0.03) and higher rates of non-paroxysmal atrial fibrillation (84.0% vs. 64.9%, p = 0.06). Other baseline parameters and device positions were not different. Most ischemic events occurred among patients with single antiplatelet therapy (50%), however, stroke/SE was also observed under dual antiplatelet therapy (25%) or oral anticoagulation (20%). CONCLUSION: Stroke/SE are documented in 14.2% and occur both in close temporal relation to the DRT finding and chronologically independently therefrom. Identification of risk factors remains cumbersome, putting all DRT patients at substantial risk for stroke/SE. Further studies are necessary to minimize the risk of DRT and ischemic events.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Trombose , Humanos , Resultado do Tratamento , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Trombose/diagnóstico , Trombose/epidemiologia , Trombose/etiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Apêndice Atrial/diagnóstico por imagem
13.
Am J Cardiol ; 197: 87-92, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37137798

RESUMO

Sex-specific thresholds of aortic valve calcification (AVC) correlate with aortic stenosis (AS) and may complement echocardiography to determine AS severity. Importantly, current guideline-recommended thresholds of AVC scores derived by multislice computed tomography do not distinguish between bicuspid and tricuspid aortic valves. The objective of this study was to evaluate the sex-specific differences in the amount of AVC in patients with severe AS and tricuspid (TAV) versus bicuspid (BAV) aortic valve morphologies, retrospectively evaluated by 2 tertiary care institutions. The inclusion criteria comprised patients with severe AS and a left ventricular ejection fraction ≥50% and suitable imaging examinations. The study included 1,450 patients (723 men; 49.9%) with severe AS, including 1,335 patients with TAV (92.1%) and 115 with BAV (17.9%). The calculated Agatston score was higher in BAV patients (men: BAV 4,358 [2,644 to 6,005] AU vs TAV 2,643 [1,727 to 3,794] AU, p <0.01; women: BAV 2,174 [1,330 to 4,378] AU vs TAV 1,703 [964 to 2,534] AU, p <0.01), also when indexed for valve dimensions and body surface area (men: BAV 2,227 [321 to 3,105] AU/m2 vs TAV 1,333 [872 to 1,913] AU/m2, p <0.01; women: BAV 1,326 [782 to 2,148] AU/m2 vs TAV 930 [546 to 1,456] AU/m2, p <0.01). Differences between the BAV- and TAV-derived Agatston score was more prominent in concordant severe AS. In conclusion, sex-specific Agatston scores in severe AS were approximately 1/3 higher in patients with BAV than in patients with TAV for both women and men. Optimal AVC thresholds should be adjusted for BAV, also respecting considerable prognostic implications.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Masculino , Humanos , Feminino , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem
14.
Nat Commun ; 14(1): 2404, 2023 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-37100836

RESUMO

Antiplatelet medication is standard of care in acute myocardial infarction (AMI). However, it may have obscured beneficial properties of the activated platelet secretome. We identify platelets as major source of a sphingosine-1-phosphate (S1P) burst during AMI, and find its magnitude to favorably associate with cardiovascular mortality and infarct size in STEMI patients over 12 months. Experimentally, administration of supernatant from activated platelets reduces infarct size in murine AMI, which is blunted in platelets deficient for S1P export (Mfsd2b) or production (Sphk1) and in mice deficient for cardiomyocyte S1P receptor 1 (S1P1). Our study reveals an exploitable therapeutic window in antiplatelet therapy in AMI as the GPIIb/IIIa antagonist tirofiban preserves S1P release and cardioprotection, whereas the P2Y12 antagonist cangrelor does not. Here, we report that platelet-mediated intrinsic cardioprotection is an exciting therapeutic paradigm reaching beyond AMI, the benefits of which may need to be considered in all antiplatelet therapies.


Assuntos
Plaquetas , Infarto do Miocárdio , Humanos , Camundongos , Animais , Infarto do Miocárdio/tratamento farmacológico , Esfingosina , Lisofosfolipídeos/uso terapêutico , Miócitos Cardíacos
15.
EuroIntervention ; 19(2): e176-e187, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37013922

RESUMO

BACKGROUND: Reducing rates of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is important for achieving the best procedural outcomes. The cusp overlap technique (COT) implements procedural steps including an overlap angulation of the right and left coronary cusp to mitigate this complication. AIMS: We investigated the incidence of PPI and complication rates following the COT compared to the standard three-cusp implantation technique (3CT) in an all-comers cohort. METHODS: A total of 2,209 patients underwent TAVI with the self-expanding Evolut platform from January 2016 to April 2022 at five sites. Baseline, procedural and in-hospital outcome characteristics were compared for both techniques before and after one-to-one propensity score matching. RESULTS: A total of 1,151 patients were implanted using the 3CT and 1,058 using the COT. At discharge, the rates of PPI (17.0 vs 12.3%; p=0.002) and moderate/severe paravalvular regurgitation (4.6% vs 2.4%; p=0.006) were significantly reduced with the COT compared with 3CT within the unmatched cohort. Overall procedural success and complication rates were similar; major bleeding was less common in the COT group (7.0% vs 4.6%; p=0.020). These results remained consistent after propensity score matching. In multivariable logistic regression analysis, right bundle branch block (odds ratio [OR] 7.19, 95% confidence interval [CI]: 5.18-10.0; p<0.001) and diabetes mellitus (OR 1.38, 95% CI: 1.05-1.80; p=0.021) emerged as predictors of PPI, whereas the COT (OR 0.63, 95% CI: 0.49-0.82; p<0.001) was protective. CONCLUSIONS: The introduction of the COT was associated with a significant and relevant reduction of PPI and paravalvular regurgitation rates without an increase in complication rates.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
16.
Hellenic J Cardiol ; 74: 1-7, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37119968

RESUMO

OBJECTIVES: Left ventricular reverse remodeling (LVRR) is associated with improved outcome in patients with heart failure. Factors associated with and predictive of LVRR in patients with low-flow low-gradient aortic stenosis (LFLG AS) after transcatheter aortic valve implantation (TAVI) and its impact on outcome were assessed. METHODS: Pre- and postprocedural left ventricular (LV) function and volume were investigated in 219 patients with LFLG. LVRR was defined as an absolute increase of ≥10% in LV ejection fraction (LVEF) and reduction of ≥15% in LV end-systolic volume (LVESV). The primary endpoint was the combination of all-cause mortality and rehospitalization for heart failure. RESULTS: The mean LVEF was 35.0 ± 10.0%, with a stroke volume index (SVI) of 25.9 ± 6.0 mL/m2 and LVESV of 94.04 ± 46.0 mL. At a median of 5.2 months (interquartile range, 2.7-8.1 months), 77.2% (n = 169) of the patients showed echocardiographic evidence of LVRR. A multivariate model revealed three independent factors for LVRR after TAVI: SVI of <25 mL/m2 (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.08-3.58; p < 0.01), LVEF of <30% (HR, 2.76; 95% CI, 1.53-2.91; p < 0.01), and valvulo-arterial impedance (Zva) of <5 mmHg/mL/m2 (HR, 5.36; 95% CI, 1.80-15.98; p < 0.01). Patients without evidence of LVRR showed a significantly higher incidence of the 1-year combined endpoint (32 [64.0%] vs. 75 [44.4%], p < 0.01). CONCLUSIONS: The majority of patients with LFLG AS show LVRR after TAVI, which is associated with favorable outcomes. An SVI of <25 mL/m2, LVEF of <30%, and Zva < 5mmHg/mL/m2 represent predictors of LVRR.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Função Ventricular Esquerda , Volume Sistólico , Insuficiência Cardíaca/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Remodelação Ventricular , Índice de Gravidade de Doença
17.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
18.
Eur Heart J Cardiovasc Imaging ; 24(6): 768-775, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-36680538

RESUMO

AIMS: To study sex-specific differences in the amount and distribution of aortic valve calcification (AVC) and to correlate the AVC load with paravalvular leakage (PVL) post-transcatheter aortic valve intervention (TAVI). METHODS AND RESULTS: This registry included 1801 patients undergoing TAVI with a Sapien3 or Evolut valve in two tertiary care institutions. Exclusion criteria encompassed prior aortic valve replacement, suboptimal multidetector computed tomography (MDCT) quality, and suboptimal transthoracic echocardiography images. Calcium content and distribution were derived from MDCT. In this study, the median age was 81.7 (25th-75th percentile 77.5-85.3) and 54% male. Men, compared to women, were significantly younger [81.2 (25th-75th percentile 76.5-84.5) vs. 82.4 (78.2-85.9), P ≤ 0.01] and had a larger annulus area [512 mm2 (25th-75th percentile 463-570) vs. 405 mm2 (365-454), P < 0.01] and higher Agatston score [2567 (25th-75th percentile 1657-3913) vs. 1615 (25th-75th percentile 905-2484), P < 0.01]. In total, 1104 patients (61%) had none-trace PVL, 648 (36%) mild PVL, and 49 (3%) moderate PVL post-TAVI. There was no difference in the occurrence of moderate PVL between men and women (3% vs. 3%, P = 0.63). Cut-off values for the Agatston score as predictor for moderate PVL based on the receiver-operating characteristic curve were 4070 (sensitivity 0.73, specificity 0.79) for men and 2341 (sensitivity 0.74, specificity 0.73) for women. CONCLUSION: AVC is a strong predictor for moderate PVL post-TAVI. Although the AVC load in men is higher compared to women, there is no difference in the incidence of moderate PVL. Sex-specific Agatston score cut-offs to predict moderate PVL were almost double as high in men vs. women.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Tomografia Computadorizada Multidetectores/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos
19.
Pharmacology ; 108(2): 199-203, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36513038

RESUMO

Percutaneous left atrial appendage occlusion (LAAO) is an option to reduce the risk of stroke in patients with atrial fibrillation and high bleeding risk. However, device-related thrombosis (DRT) post LAAO is feared as complication. Simard et al. found a very high incidence of DRT compared to other trials. However, antithrombotic regimen and used devices have not been compared between studies. We compared DRT formation, antithrombotic regimen and used device in the recent DRT study, the Amplatzer IDE trial, and the Düsseldorf (DUS) LAAO registry. Occluder thrombosis occurred in 25.3% in the DRT study, 3.8% in the Amulet IDE trial, and 3.3% in the DUS LAAO registry (p < 0.0001). Oral anticoagulation-based regimen was more frequent in the DRT study compared to the DUS LAAO registry, whereas dual antiplatelet regimen was more frequent in the DUS LAAO registry (p < 0.0001). Amplatzer amulet was more frequently used in the DUS LAAO registry as compared to the DRT study (p < 0.0001). DRT is a feared complication after LAAO and seems to be dependent on antiplatelet treatment and underlying device. A clinical study controlling for device and antithrombotic regimen is needed to smash this Gordian knot.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Trombose , Humanos , Fibrinolíticos , Acidente Vascular Cerebral/epidemiologia , Trombose/etiologia , Resultado do Tratamento , Anticoagulantes
20.
ESC Heart Fail ; 10(1): 334-341, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36217778

RESUMO

AIMS: Therapeutic options targeting post-ischaemic cardiac remodelling are sparse. The bioactive sphingolipid sphingosine-1-phosphate (S1P) reduces ischaemia/reperfusion injury. However, its impact on post-ischaemic remodelling independently of its infarct size (IS)-reducing effect is yet unknown and was addressed in this study. METHODS AND RESULTS: Acute myocardial infarction (AMI) in mice was induced by permanent ligation of the left anterior descending artery (LAD). C57Bl6 were treated with the S1P lyase inhibitor 4-deoxypyridoxine (DOP) starting 7 days prior to AMI to increase endogenous S1P concentrations. Cardiac function and myocardial healing were assessed by cardiovascular magnetic resonance imaging (cMRI), murine echocardiography, histomorphology, and gene expression analysis. DOP effects were investigated in cardiomyocyte-specific S1P receptor 1 deficient (S1PR1 Cardio Cre+) and Cre- control mice and S1P concentrations measured by LC-MS/MS. IS and cardiac function did not differ between control and DOP-treated groups on day one after LAD-ligation despite fourfold increase in plasma S1P. In contrast, cardiac function was clearly improved and myocardial scar size reduced, respectively, on Day 21 in DOP-treated mice. The latter also exhibited smaller cardiomyocyte size and reduced embryonic gene expression. The benefit of DOP treatment was abolished in S1PR1 Cardio Cre+. CONCLUSIONS: S1P improves cardiac function and myocardial healing post AMI independently of initial infarct size and accomplishes this via the cardiomyocyte S1PR1. Hence, in addition to its beneficial effects on I/R injury, S1PR1 may be a promising target in post-infarction myocardial remodelling as adjunctive therapy to revascularization as well as in patients not eligible for standard interventional procedures.


Assuntos
Infarto do Miocárdio , Receptores de Lisoesfingolipídeo , Camundongos , Animais , Receptores de Esfingosina-1-Fosfato/uso terapêutico , Cromatografia Líquida , Receptores de Lisoesfingolipídeo/genética , Receptores de Lisoesfingolipídeo/metabolismo , Receptores de Lisoesfingolipídeo/uso terapêutico , Espectrometria de Massas em Tandem , Infarto do Miocárdio/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...