Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 117(18): 182503, 2016 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-27835000

RESUMO

Masses of ^{52g,52m}Co were measured for the first time with an accuracy of ∼10 keV, an unprecedented precision reached for short-lived nuclei in the isochronous mass spectrometry. Combining our results with the previous ß-γ measurements of ^{52}Ni, the T=2, J^{π}=0^{+} isobaric analog state (IAS) in ^{52}Co was newly assigned, questioning the conventional identification of IASs from the ß-delayed proton emissions. Using our energy of the IAS in ^{52}Co, the masses of the T=2 multiplet fit well into the isobaric multiplet mass equation. We find that the IAS in ^{52}Co decays predominantly via γ transitions while the proton emission is negligibly small. According to our large-scale shell model calculations, this phenomenon has been interpreted to be due to very low isospin mixing in the IAS.

2.
Rev Sci Instrum ; 87(2): 02A719, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931937

RESUMO

Compared with traditional de-ionized pressurized-water cooled magnet of ECRIS, evaporative cooling magnet has some special characteristics, such as high cooling efficiency, simple maintenance, and operation. The analysis is carried out according to the design and operation of LECR4 (Lanzhou Electron Cyclotron Resonance ion source No. 4, since July 2013), whose magnet is cooled by evaporative cooling technology. The insulation coolant replaces the de-ionized pressurized-water to absorb the heat of coils, and the physical and chemical properties of coolant remain stable for a long time with no need for purification or filtration. The coils of magnet are immersed in the liquid coolant. For the higher cooling efficiency of coolant, the current density of coils can be greatly improved. The heat transfer process executes under atmospheric pressure, and the temperature of coils is lower than 70 °C when the current density of coils is 12 A/mm(2). On the other hand, the heat transfer temperature of coolant is about 50 °C, and the heat can be transferred to fresh air which can save cost of water cooling system. Two years of LECR4 stable operation show that evaporative cooling technology can be used on magnet of ECRIS, and the application advantages are very obvious.

3.
Rev Sci Instrum ; 87(2): 02A738, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931956

RESUMO

LECR4 (Lanzhou ECR ion source No. 4) is a room temperature electron cyclotron resonance ion source, designed to produce high current, high charge state ion beams for the SSC-LINAC injector (a new injector for sector separated cyclotron) at the Institute of Modern Physics. LECR4 also serves as a PoP machine for the application of evaporative cooling technology in accelerator field. To achieve those goals, LECR4 ECR ion source has been optimized for the operation at 18 GHz. During 2014, LECR4 ion source was commissioned at 18 GHz microwave of 1.6 kW. To further study the influence of injection stage to the production of medium and high charge state ion beams, in March 2015, the injection stage with pumping system was installed, and some optimum results were produced, such as 560 eµA of O(7+), 620 eµA of Ar(11+), 430 eµA of Ar(12+), 430 eµA of Xe(20+), and so on. The comparison will be discussed in the paper.

4.
Phys Rev Lett ; 109(10): 102501, 2012 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-23005283

RESUMO

Isochronous mass spectrometry has been applied to neutron-deficient 58Ni projectile fragments at the HIRFL-CSR facility in Lanzhou, China. Masses of a series of short-lived T(z)=-3/2 nuclides including 41Ti, 45Cr, 49Fe, and 53Ni have been measured with a precision of 20-40 keV. The new data enable us to test for the first time the isobaric multiplet mass equation (IMME) in fp-shell nuclei. We observe that the IMME is inconsistent with the generally accepted quadratic form for the A=53, T=3/2 quartet. We perform full space shell model calculations and compare them with the new experimental results.

5.
Br J Dermatol ; 166(5): 1100-6, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22136631

RESUMO

UNLABELLED: BACKGROUND; Heavy ions represent the best tool for external radiotherapy (RT) of inoperable tumours. Heavy ion RT has been used in the treatment of various tumours, especially for radioresistant tumours mediated by hypoxia, localized near organs at risk. Most of these treatments are concentrated in deep-seated tumours such as those of the brain, head, lung, liver, rectum and urogenital organs, and treatment of skin carcinomas is limited. OBJECTIVES: To evaluate the outcome and toxicity after carbon ion RT for skin carcinomas at the Heavy Ion Research Facility in Lanzhou, China. METHODS: Between November 2006 and March 2009, 45 patients with skin carcinoma [squamous cell carcinoma (SCC) (n = 16), basal cell carcinoma (BCC) (n = 12), malignant melanoma (MM) (n = 7), Bowen disease (n = 8) and Paget disease (n = 2)] were treated with carbon ion RT within a clinical Phase I trial. Patients received total doses of 60-70 GyE for SCC and BCC, 61-75 GyE for MM, 60 GyE for Bowen disease and 42·5 GyE for Paget disease, administered in 6-11 fractions over 6-11 days, with a fraction dose of 7-10 GyE. RESULTS: The mean follow-up was 24 months, range 12-36 months. The actuarial local control rates at 1 and 3 years were 90·9% and 65·5% for SCC, 91·7% and 80·2% for BCC, 85·7% and 42·9% for MM, 90% and 90% for Bowen and Paget diseases, respectively. The actuarial 1- and 3-year overall survival rates for 45 patients were 88·9% and 86%, respectively. No severe side-effects greater than Common Toxicity Criteria grade 3 have been observed. CONCLUSIONS: The results demonstrated that heavy ion RT offers high local tumour control and progression-free survival rates without significant radiation-induced toxicity for patients with skin carcinomas.


Assuntos
Carbono/uso terapêutico , Radioterapia com Íons Pesados , Neoplasias Cutâneas/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Radioterapia/efeitos adversos , Resultado do Tratamento
6.
Phys Rev Lett ; 106(11): 112501, 2011 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-21469858

RESUMO

Mass excesses of short-lived A=2Z-1 nuclei (63)Ge, (65)As, (67)Se, and (71)Kr have been directly measured to be -46,921(37), -46,937(85), -46,580(67), and -46,320(141) keV, respectively. The deduced proton separation energy of -90(85) keV for (65)As shows that this nucleus is only slightly proton unbound. X-ray burst model calculations with the new mass excess of (65)As suggest that the majority of the reaction flow passes through (64)Ge via proton capture, indicating that (64)Ge is not a significant rp-process waiting point.

7.
Rev Sci Instrum ; 79(2 Pt 2): 02A315, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315105

RESUMO

There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e microA of O(7+), 505 e microA of Xe(20+), 306 e microA of Xe(27+), and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...