Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 6(19): 2623-33, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25411705

RESUMO

BACKGROUND: A microfluidic platform-based assay was validated to measure a humanized or fully human IgG in rat serum samples. MATERIALS & METHODS: The cumulative assessment for accuracy and precision was performed with three accuracy and precision runs. RESULTS: The inter-assay accuracy (mean %bias) ranged from -4.3 to 3.8%, and inter-batch %CV ranged from 5.0 to 9.2%. The method acceptance criterion was determined as 15% total error. The assay dynamic range was 50 to 10000 ng/ml. Incurred sample reanalysis passed with 95% of samples meeting incurred sample reanalysis acceptance criteria. Potential carryover effect was not observed. CONCLUSION: This study demonstrated the need for evaluating additional platform-specific processes when new technologies are employed to ensure the reproducibility of a successfully validated microfluidic platform method.


Assuntos
Anticorpos/química , Cromatografia Líquida de Alta Pressão/métodos , Microfluídica/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Humanos , Camundongos , Reprodutibilidade dos Testes
2.
Bioanalysis ; 2(9): 1587-96, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21083287

RESUMO

BACKGROUND: Incurred sample reanalysis (ISR) is the most recent in-study validation parameter that regulatory agencies have mandated to ensure reproducibility of bioanalytical methods supporting pharmacokinetic/toxicokinetic and clinical studies. The present analysis describes five representative case studies for macromolecule therapeutics. METHOD: Single ISR acceptance criteria (within 30% of the averaged or original concentration) and a modified Bland-Altman (BA) approach were used to assess accuracy and precision of ISR results. General concordance between the two criteria was examined using simulation studies. RESULTS: All five methods met the ISR criteria. The results indicated that thorough method development and prestudy validation were prerequisites for a successful ISR. The overall agreement between the original and reanalyzed results as determined by BA was within 20%. Simulation studies indicated that concordance between the ISR criteria and BA was observed in 95% of the cases. Dilution factors had no significant impact on the ISR, even for C(max) samples where 1:100 or higher dilutions were used. CONCLUSION: The current ISR acceptance criteria for macromolecules was scientifically and statistically meaningful for methods with a total error of 25% or less.


Assuntos
Técnicas de Química Analítica/métodos , Substâncias Macromoleculares/análise , Animais , Ensaios Clínicos Fase I como Assunto , Humanos , Substâncias Macromoleculares/sangue , Preparações Farmacêuticas/metabolismo , Ratos , Reprodutibilidade dos Testes , Equivalência Terapêutica
3.
AAPS J ; 12(4): 576-85, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20625864

RESUMO

The knowledge of in vivo biotransformation (e.g., proteolysis) of protein therapeutic candidates reveals structural liabilities that impact stability. This information aids the development and confirmation of ligand-binding assays with the required specificity for bioactive moieties (including intact molecule and metabolites) for appropriate PK profiling. Furthermore, the information can be used for re-engineering of constructs to remove in vivo liabilities in order to design the most stable candidates. We have developed a strategic approach of ligand-binding mass spectrometry (LBMS) to study biotransformation of fusion proteins of peptides fused to human Fc ("peptibodies") using anti-human Fc immunoaffinity capture followed by tiered mass spectrometric interrogation. LBMS offers the combined power of selectivity of ligand capture with the specificity and detailed molecular-level information of mass spectrometry. In this paper, we demonstrate the preclinical application of LBMS to three peptibodies, AMG531 (romiplostim), AMG195(linear), and AMG195(loop), that target the thrombopoietin receptor. The data show that ligand capture offers excellent sample cleanup and concentration of intact peptibodies and metabolites for subsequent query by matrix-assisted laser desorption ionization time-of-flight mass spectrometry for identification of in vivo proteolytic points. Additional higher-resolution analysis by nanoscale liquid chromatography interfaced with electrospray ionization mass spectrometry is required for identification of heterogeneous metabolites. Five proteolytic points are accurately identified for AMG531 and two for AMG195(linear), while AMG195(loop) is the most stable construct in rats. We recommend the use of LBMS to assess biotransformation and in vivo stability during early preclinical phase development for all novel fusion proteins.


Assuntos
Imunoensaio/métodos , Peptídeos/química , Receptores de Trombopoetina/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sequência de Aminoácidos , Animais , Biotransformação , Ligantes , Dados de Sequência Molecular , Ratos , Ratos Sprague-Dawley , Receptores Fc/sangue , Proteínas Recombinantes de Fusão/sangue , Proteínas Recombinantes de Fusão/farmacocinética , Trombopoetina/sangue , Trombopoetina/farmacocinética
4.
Eur J Pharmacol ; 610(1-3): 110-8, 2009 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-19292985

RESUMO

The ICOS (Inducible T cell Co-Stimulator)/B7RP-1 (B7-related protein 1) interaction is critical for the proper activation of a T lymphocyte. In this manuscript we describe a systematic in vivo approach to determine the level of blockade required to impair the generation of a T cell-dependent antibody response. We have developed an overall strategy for correlating drug exposure, target saturation, and efficacy in a biological response that can be generalized for most protein therapeutics. Using this strategy, we determined that low levels of B7RP-1 blockade are still sufficient to inhibit the immune response. These data suggest that contact between the T cell and the antigen-presenting cell during antigen presentation is much more sensitive to inhibition than previously believed and that ICOS/B7RP-1 blockade may be efficacious in the treatment of autoimmune diseases.


Assuntos
Antígeno B7-1/farmacologia , Fenômenos do Sistema Imunitário/efeitos dos fármacos , Hidróxido de Alumínio/imunologia , Animais , Anticorpos Monoclonais/farmacologia , Células Apresentadoras de Antígenos/imunologia , Antígenos CD19/metabolismo , Linfócitos B/metabolismo , Antígeno B7-1/genética , Sítios de Ligação , Complexo CD3/metabolismo , Citocinas/sangue , Relação Dose-Resposta a Droga , Feminino , Fluoresceína-5-Isotiocianato/metabolismo , Corantes Fluorescentes/metabolismo , Hemocianinas/imunologia , Ligante Coestimulador de Linfócitos T Induzíveis , Camundongos , Camundongos Endogâmicos BALB C , Modelos Imunológicos , Ligação Proteica , Proteínas Recombinantes de Fusão/farmacologia , Linfócitos T/metabolismo , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...