Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Toxics ; 11(6)2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37368613

RESUMO

Food security is a global issue, since it is closely related to human health. Antibiotics play a significant role in animal husbandry owing to their desirable broad-spectrum antibacterial activity. However, irrational use of antibiotics has caused serious environmental pollution and food safety problems; thus, the on-site detection of antibiotics is in high demand in environmental analysis and food safety assessment. Aptamer-based sensors are simple to use, accurate, inexpensive, selective, and are suitable for detecting antibiotics for environmental and food safety analysis. This review summarizes the recent advances in aptamer-based electrochemical, fluorescent, and colorimetric sensors for antibiotics detection. The review focuses on the detection principles of different aptamer sensors and recent achievements in developing electrochemical, fluorescent, and colorimetric aptamer sensors. The advantages and disadvantages of different sensors, current challenges, and future trends of aptamer-based sensors are also discussed.

2.
Food Chem ; 408: 135218, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36563621

RESUMO

An enzyme-free, sensitive, and convenient approach was reported for the P-nitrophenyl substituent organophosphorus pesticides (NSOPs) of paraoxon-methyl (PM), paraoxon-ethyl (PE), parathion-methyl (PTM) and parathion-ethyl (PTE)) by indirectly quantification of the 4-nitrophenol (4-NP, hydrolysis product of the NSOPs). NaOH instead of hydrolase/nanozyme was applied, and temperature, pH, ultrasound was investigated to improve the NSOPs hydrolysis. Under the optimized conditions, the hydrolysis efficiencies were up to 99.9 %, 99.9 %, 99.6 %, 96.0 % for PM (10 min), PE (30 min), PTM (90 min) and PTE (120 min), based on which a low detection limits of 0.06 (PM), 0.07 (PE), 0.06 (PTM) and 0.07 (PTE) ppb were calculated with the 4-NP detection limit (0.03 ppb). Furthermore, the method exhibited good performance for the NSOPs with recoveries from 88.87 % to 100.33 % in real samples. This indirect approach offered an ultrasensitive alternative for the NSOPs detection, which holds great potential in practical application for the assessment of food safety and environmental risks.


Assuntos
Metil Paration , Paration , Praguicidas , Paraoxon , Compostos Organofosforados
3.
PLoS One ; 15(12): e0244297, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33362222

RESUMO

Acetamiprid (ACE) is a kind of broad-spectrum pesticide that has potential health risk to human beings. Aptamers (Ap-DNA (1)) have a great potential as analytical tools for pesticide detection. In this work, a label-free electrochemical sensing assay for ACE determination is presented by electrochemical impedance spectroscopy (EIS). And the specific binding model between ACE and Ap-DNA (1) was further investigated for the first time. Circular dichroism (CD) spectroscopy and EIS demonstrated that the single strand AP-DNA (1) first formed a loosely secondary structure in Tris-HClO4 (20 mM, pH = 7.4), and then transformed into a more stable hairpin-like structure when incubated in binding buffer (B-buffer). The formed stem-loop bulge provides the specific capturing sites for ACE, forming ACE/AP-DNA (1) complex, and induced the RCT (charge transfer resistance) increase between the solution-based redox probe [Fe(CN)6]3-/4- and the electrode surface. The change of ΔRCT (charge transfer resistance change, ΔRCT = RCT(after)-RCT(before)) is positively related to the ACE level. As a result, the AP-DNA (1) biosensor showed a high sensitivity with the ACE concentration range spanning from 5 nM to 200 mM and a detection limit of 1 nM. The impedimetric AP-DNA (1) sensor also showed good selectivity to ACE over other selected pesticides and exhbited excellent performance in environmental water and orange juice samples analysis, with spiked recoveries in the range of 85.8% to 93.4% in lake water and 83.7% to 89.4% in orange juice. With good performance characteristics of practicality, sensitivity and selectivity, the AP-DNA (1) sensor holds a promising application for the on-site ACE detection.


Assuntos
Aptâmeros de Nucleotídeos/química , Espectroscopia Dielétrica/métodos , Neonicotinoides/análise , Aptâmeros de Nucleotídeos/metabolismo , Técnicas Biossensoriais/métodos , DNA/química , DNA de Cadeia Simples/química , Técnicas Eletroquímicas/métodos , Eletrodos , Ouro/química , Limite de Detecção , Neonicotinoides/química , Conformação de Ácido Nucleico/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA