Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 526
Filtrar
1.
Magn Reson Med ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38624162

RESUMO

Deep learning (DL) has emerged as a leading approach in accelerating MRI. It employs deep neural networks to extract knowledge from available datasets and then applies the trained networks to reconstruct accurate images from limited measurements. Unlike natural image restoration problems, MRI involves physics-based imaging processes, unique data properties, and diverse imaging tasks. This domain knowledge needs to be integrated with data-driven approaches. Our review will introduce the significant challenges faced by such knowledge-driven DL approaches in the context of fast MRI along with several notable solutions, which include learning neural networks and addressing different imaging application scenarios. The traits and trends of these techniques have also been given which have shifted from supervised learning to semi-supervised learning, and finally, to unsupervised learning methods. In addition, MR vendors' choices of DL reconstruction have been provided along with some discussions on open questions and future directions, which are critical for the reliable imaging systems.

2.
Magn Reson Med ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38650080

RESUMO

PURPOSE: CEST can image macromolecules/compounds via detecting chemical exchange between labile protons and bulk water. B1 field inhomogeneity impairs CEST quantification. Conventional B1 inhomogeneity correction methods depend on interpolation algorithms, B1 choices, acquisition number or calibration curves, making reliable correction challenging. This study proposed a novel B1 inhomogeneity correction method based on a direct saturation (DS) removed omega plot model. METHODS: Four healthy volunteers underwent B1 field mapping and CEST imaging under four nominal B1 levels of 0.75, 1.0, 1.5, and 2.0 µT at 5T. DS was resolved using a multi-pool Lorentzian model and removed from respective Z spectrum. Residual spectral signals were used to construct the omega plot as a linear function of 1/ B 1 2 $$ {B}_1^2 $$ , from which corrected signals at nominal B1 levels were calculated. Routine asymmetry analysis was conducted to quantify amide proton transfer (APT) effect. Its distribution across white matter was compared before and after B1 inhomogeneity correction and also with the conventional interpolation approach. RESULTS: B1 inhomogeneity yielded conspicuous artifact on APT images. Such artifact was mitigated by the proposed method. Homogeneous APT maps were shown with SD consistently smaller than that before B1 inhomogeneity correction and the interpolation method. Moreover, B1 inhomogeneity correction from two and four CEST acquisitions yielded similar results, superior over the interpolation method that derived inconsistent APT contrasts among different B1 choices. CONCLUSION: The proposed method enables reliable B1 inhomogeneity correction from at least two CEST acquisitions, providing an effective way to improve quantitative CEST MRI.

3.
Sci Adv ; 10(16): eadk1855, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38630814

RESUMO

Transfected stem cells and T cells are promising in personalized cell therapy and immunotherapy against various diseases. However, existing transfection techniques face a fundamental trade-off between transfection efficiency and cell viability; achieving both simultaneously remains a substantial challenge. This study presents an acoustothermal transfection method that leverages acoustic and thermal effects on cells to enhance the permeability of both the cell membrane and nuclear envelope to achieve safe, efficient, and high-throughput transfection of primary T cells and stem cells. With this method, two types of plasmids were simultaneously delivered into the nuclei of mesenchymal stem cells (MSCs) with efficiencies of 89.6 ± 1.2%. CXCR4-transfected MSCs could efficiently target cerebral ischemia sites in vivo and reduce the infarct volume in mice. Our acoustothermal transfection method addresses a key bottleneck in balancing the transfection efficiency and cell viability, which can become a powerful tool in the future for cellular and gene therapies.


Assuntos
Células-Tronco Mesenquimais , Camundongos , Animais , Transfecção , Células-Tronco Mesenquimais/metabolismo , Plasmídeos , Membrana Celular , Terapia Baseada em Transplante de Células e Tecidos
4.
Eur Radiol ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38355987

RESUMO

OBJECTIVES: Total-body PET/CT scanners with long axial fields of view have enabled unprecedented image quality and quantitative accuracy. However, the ionizing radiation from CT is a major issue in PET imaging, which is more evident with reduced radiopharmaceutical doses in total-body PET/CT. Therefore, we attempted to generate CT-free attenuation-corrected (CTF-AC) total-body PET images through deep learning. METHODS: Based on total-body PET data from 122 subjects (29 females and 93 males), a well-established cycle-consistent generative adversarial network (Cycle-GAN) was employed to generate CTF-AC total-body PET images directly while introducing site structures as prior information. Statistical analyses, including Pearson correlation coefficient (PCC) and t-tests, were utilized for the correlation measurements. RESULTS: The generated CTF-AC total-body PET images closely resembled real AC PET images, showing reduced noise and good contrast in different tissue structures. The obtained peak signal-to-noise ratio and structural similarity index measure values were 36.92 ± 5.49 dB (p < 0.01) and 0.980 ± 0.041 (p < 0.01), respectively. Furthermore, the standardized uptake value (SUV) distribution was consistent with that of real AC PET images. CONCLUSION: Our approach could directly generate CTF-AC total-body PET images, greatly reducing the radiation risk to patients from redundant anatomical examinations. Moreover, the model was validated based on a multidose-level NAC-AC PET dataset, demonstrating the potential of our method for low-dose PET attenuation correction. In future work, we will attempt to validate the proposed method with total-body PET/CT systems in more clinical practices. CLINICAL RELEVANCE STATEMENT: The ionizing radiation from CT is a major issue in PET imaging, which is more evident with reduced radiopharmaceutical doses in total-body PET/CT. Our CT-free PET attenuation correction method would be beneficial for a wide range of patient populations, especially for pediatric examinations and patients who need multiple scans or who require long-term follow-up. KEY POINTS: • CT is the main source of radiation in PET/CT imaging, especially for total-body PET/CT devices, and reduced radiopharmaceutical doses make the radiation burden from CT more obvious. • The CT-free PET attenuation correction method would be beneficial for patients who need multiple scans or long-term follow-up by reducing additional radiation from redundant anatomical examinations. • The proposed method could directly generate CT-free attenuation-corrected (CTF-AC) total-body PET images, which is beneficial for PET/MRI or PET-only devices lacking CT image poses.

5.
Nat Commun ; 15(1): 1588, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383659

RESUMO

High performance X-ray detector with ultra-high spatial and temporal resolution are crucial for biomedical imaging. This study reports a dynamic direct-conversion CMOS X-ray detector assembled with screen-printed CsPbBr3, whose mobility-lifetime product is 5.2 × 10-4 cm2 V-1 and X-ray sensitivity is 1.6 × 104 µC Gyair-1 cm-2. Samples larger than 5 cm[Formula: see text]10 cm can be rapidly imaged by scanning this detector at a speed of 300 frames per second along the vertical and horizontal directions. In comparison to traditional indirect-conversion CMOS X-ray detector, this perovskite CMOS detector offers high spatial resolution (5.0 lp mm-1) X-ray radiographic imaging capability at low radiation dose (260 nGy). Moreover, 3D tomographic images of a biological specimen are also successfully reconstructed. These results highlight the perovskite CMOS detector's potential in high-resolution, large-area, low-dose dynamic biomedical X-ray and CT imaging, as well as in non-destructive X-ray testing and security scanning.

6.
IEEE Trans Med Imaging ; PP2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38386580

RESUMO

Full quantification of brain PET requires the blood input function (IF), which is traditionally achieved through an invasive and time-consuming arterial catheter procedure, making it unfeasible for clinical routine. This study presents a deep learning based method to estimate the input function (DLIF) for a dynamic brain FDG scan. A long short-term memory combined with a fully connected network was used. The dataset for training was generated from 85 total-body dynamic scans obtained on a uEXPLORER scanner. Time-activity curves from 8 brain regions and the carotid served as the input of the model, and labelled IF was generated from the ascending aorta defined on CT image. We emphasize the goodness-of-fitting of kinetic modeling as an additional physical loss to reduce the bias and the need for large training samples. DLIF was evaluated together with existing methods in terms of RMSE, area under the curve, regional and parametric image quantifications. The results revealed that the proposed model can generate IFs that closer to the reference ones in terms of shape and amplitude compared with the IFs generated using existing methods. All regional kinetic parameters calculated using DLIF agreed with reference values, with the correlation coefficient being 0.961 (0.913) and relative bias being 1.68±8.74% (0.37±4.93%) for Ki (K1). In terms of the visual appearance and quantification, parametric images were also highly identical to the reference images. In conclusion, our experiments indicate that a trained model can infer an image-derived IF from dynamic brain PET data, which enables subsequent reliable kinetic modeling.

7.
Adv Drug Deliv Rev ; 207: 115200, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38364906

RESUMO

Nanoscale contrast agents have emerged as a versatile platform in the field of biomedical research, offering great potential for ultrasound imaging and therapy. Various kinds of nanoscale contrast agents have been extensively investigated in preclinical experiments to satisfy diverse biomedical applications. This paper provides a comprehensive review of the structure and composition of various nanoscale contrast agents, as well as their preparation and functionalization, encompassing both chemosynthetic and biosynthetic strategies. Subsequently, we delve into recent advances in the utilization of nanoscale contrast agents in various biomedical applications, including ultrasound molecular imaging, ultrasound-mediated drug delivery, and cell acoustic manipulation. Finally, the challenges and prospects of nanoscale contrast agents are also discussed to promote the development of this innovative nanoplatform in the field of biomedicine.


Assuntos
Meios de Contraste , Sistemas de Liberação de Medicamentos , Humanos , Meios de Contraste/química , Ultrassonografia/métodos , Sistemas de Liberação de Medicamentos/métodos , Imagem Molecular
8.
AJNR Am J Neuroradiol ; 45(3): 351-357, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38360787

RESUMO

BACKGROUND AND PURPOSE: Accurate pretreatment diagnosis and assessment of spinal vascular malformations using spinal CTA are crucial for patient prognosis, but the postprocessing reconstruction may not be able to fully depict the lesions due to the complexity inherent in spinal anatomy. Our purpose was to explore the application value of the spinal subtraction and bone background fusion CTA (SSBBF-CTA) technique in precisely depicting and localizing spinal vascular malformation lesions. MATERIALS AND METHODS: In this retrospective study, patients (between November 2017 and November 2022) with symptoms similar to those of spinal vascular malformations were divided into diseased (group A) and nondiseased (group B) groups. All patients underwent spinal CTA using Siemens dual-source CT. Multiplanar reconstruction; routine bone subtraction, and SSBBF-CTA images were obtained using the snygo.via and ADW4.6 postprocessing reconstruction workstations. Multiple observers researched the following 3 aspects: 1) preliminary screening capability using original images with multiplanar reconstruction CTA, 2) the accuracy and stability of the SSBBF-CTA postprocessing technique, and 3) diagnostic evaluation of spinal vascular malformations using the 3 types of postprocessing images. Diagnostic performance was analyzed using receiver operating characteristic analysis, while reader or image differences were analyzed using the Wilcoxon signed-rank test or the Kruskal-Wallis rank sum test. RESULTS: Forty-nine patients (groups A and B: 22 and 27 patients; mean ages, 44.0 [SD, 14.3] years and 44.6 [SD,15.2] years; 13 and 16 men) were evaluated. Junior physicians showed lower diagnostic accuracy and sensitivity using multiplanar reconstruction CTA (85.7% and 77.3%) than senior physicians (93.9% and 90.9%, 98% and 95.5%). Short-term trained juniors achieved SSBBF-CTA image accuracy similar to that of experienced physicians (P > .05). In terms of the visualization and localization of spinal vascular malformation lesions (nidus/fistula, feeding artery, and drainage vein), both multiplanar reconstruction and SSBBF-CTA outperformed routine bone subtraction CTA (P = .000). Compared with multiplanar reconstruction, SSBBF-CTA allowed less experienced physicians to achieve superior diagnostic capabilities (comparable with those of experienced radiologists) more rapidly (P < .05). CONCLUSIONS: The SSBBF-CTA technique exhibited excellent reproducibility and enabled accurate pretreatment diagnosis and assessment of spinal vascular malformations with high diagnostic efficiency, particularly for junior radiologists.


Assuntos
Doenças Vasculares , Malformações Vasculares , Masculino , Humanos , Adulto , Angiografia Digital/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Sensibilidade e Especificidade
9.
Quant Imaging Med Surg ; 14(2): 1591-1601, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415124

RESUMO

Background: Gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) has shown potential in reflecting the hepatic function alterations in nonalcoholic steatohepatitis (NASH). The purpose of this study was to evaluate whether Gd-EOB-DTPA combined with water-specific T1 (wT1) mapping can be used to detect liver inflammation in the early-stage of NASH in rats. Methods: In this study, 54 rats with methionine- and choline-deficient (MCD) diet-induced NASH and 10 normal control rats were examined. A multiecho variable flip angle gradient echo (VFA-GRE) sequence was performed and repeated 40 times after the injection of Gd-EOB-DTPA. The wT1 of the liver and the reduction rate of wT1 (rrT1) were calculated. All rats were histologically evaluated and grouped according to the NASH Clinical Research Network scoring system. Quantitative real-time polymerase chain reaction (qRT-PCR) was performed to detect the expression of Gd-EOB-DTPA transport genes. Analysis of variance and least significant difference tests were used for multiple comparisons of quantitative results between all groups. Multiple regression analysis was applied to identify variables associated with precontrast wT1 (wT1pre), and receiver operating characteristic (ROC) analysis was performed to assess the diagnostic performance. Results: The rats were grouped according to inflammatory stage (G0 =4, G1 =15, G2 =12, G3 =23) and fibrosis stage (F0 =26, F1 =19, F2 =9). After the infusion of Gd-EOB-DTPA, the rrT1 showed significant differences between the control and NASH groups (P<0.05) but no difference between the different inflammation and fibrosis groups at any time points. The areas under curve (AUCs) of rrT1 at 10, 20, and 30 minutes were only 0.53, 0.58, and 0.61, respectively, for differentiating between low inflammation grade (G0 + G1) and high inflammation grade (G2 + G3). The MRI findings were verified by qRT-PCR examination, in which the Gd-EOB-DTPA transporter expressions showed no significant differences between any inflammation groups. Conclusions: The wT1 mapping quantitative method combined with Gd-EOB-DTPA was not capable of discerning the inflammation grade in a rat model of early-stage NASH.

10.
Quant Imaging Med Surg ; 14(2): 2008-2020, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415166

RESUMO

Background: The use of segmentation architectures in medical imaging, particularly for glioma diagnosis, marks a significant advancement in the field. Traditional methods often rely on post-processed images; however, key details can be lost during the fast Fourier transformation (FFT) process. Given the limitations of these techniques, there is a growing interest in exploring more direct approaches. The adaption of segmentation architectures originally designed for road extraction for medical imaging represents an innovative step in this direction. By employing K-space data as the modal input, this method completely eliminates the information loss inherent in FFT, thereby potentially enhancing the precision and effectiveness of glioma diagnosis. Methods: In the study, a novel architecture based on a deep-residual U-net was developed to accomplish the challenging task of automatically segmenting brain tumors from K-space data. Brain tumors from K-space data with different under-sampling rates were also segmented to verify the clinical application of our method. Results: Compared to the benchmarks set in the 2018 Brain Tumor Segmentation (BraTS) Challenge, our proposed architecture had superior performance, achieving Dice scores of 0.8573, 0.8789, and 0.7765 for the whole tumor (WT), tumor core (TC), and enhanced tumor (ET) regions, respectively. The corresponding Hausdorff distances were 2.5649, 1.6146, and 2.7187 for the WT, TC, and ET regions, respectively. Notably, compared to traditional image-based approaches, the architecture also exhibited an improvement of approximately 10% in segmentation accuracy on the K-space data at different under-sampling rates. Conclusions: These results show the superiority of our method compared to previous methods. The direct performance of lesion segmentation based on K-space data eliminates the time-consuming and tedious image reconstruction process, thus enabling the segmentation task to be accomplished more efficiently.

11.
IEEE Trans Med Imaging ; 43(5): 1853-1865, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38194398

RESUMO

Diffusion models with continuous stochastic differential equations (SDEs) have shown superior performances in image generation. It can serve as a deep generative prior to solving the inverse problem in magnetic resonance (MR) reconstruction. However, low-frequency regions of k -space data are typically fully sampled in fast MR imaging, while existing diffusion models are performed throughout the entire image or k -space, inevitably introducing uncertainty in the reconstruction of low-frequency regions. Additionally, existing diffusion models often demand substantial iterations to converge, resulting in time-consuming reconstructions. To address these challenges, we propose a novel SDE tailored specifically for MR reconstruction with the diffusion process in high-frequency space (referred to as HFS-SDE). This approach ensures determinism in the fully sampled low-frequency regions and accelerates the sampling procedure of reverse diffusion. Experiments conducted on the publicly available fastMRI dataset demonstrate that the proposed HFS-SDE method outperforms traditional parallel imaging methods, supervised deep learning, and existing diffusion models in terms of reconstruction accuracy and stability. The fast convergence properties are also confirmed through theoretical and experimental validation. Our code and weights are available at https://github.com/Aboriginer/HFS-SDE.


Assuntos
Algoritmos , Encéfalo , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos
12.
EJNMMI Phys ; 11(1): 1, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38165551

RESUMO

OBJECTIVES: This study aims to decrease the scan time and enhance image quality in pediatric total-body PET imaging by utilizing multimodal artificial intelligence techniques. METHODS: A total of 270 pediatric patients who underwent total-body PET/CT scans with a uEXPLORER at the Sun Yat-sen University Cancer Center were retrospectively enrolled. 18F-fluorodeoxyglucose (18F-FDG) was administered at a dose of 3.7 MBq/kg with an acquisition time of 600 s. Short-term scan PET images (acquired within 6, 15, 30, 60 and 150 s) were obtained by truncating the list-mode data. A three-dimensional (3D) neural network was developed with a residual network as the basic structure, fusing low-dose CT images as prior information, which were fed to the network at different scales. The short-term PET images and low-dose CT images were processed by the multimodal 3D network to generate full-length, high-dose PET images. The nonlocal means method and the same 3D network without the fused CT information were used as reference methods. The performance of the network model was evaluated by quantitative and qualitative analyses. RESULTS: Multimodal artificial intelligence techniques can significantly improve PET image quality. When fused with prior CT information, the anatomical information of the images was enhanced, and 60 s of scan data produced images of quality comparable to that of the full-time data. CONCLUSION: Multimodal artificial intelligence techniques can effectively improve the quality of pediatric total-body PET/CT images acquired using ultrashort scan times. This has the potential to decrease the use of sedation, enhance guardian confidence, and reduce the probability of motion artifacts.

13.
Cancer Imaging ; 24(1): 2, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167538

RESUMO

OBJECTIVES: Commercialized total-body PET scanners can provide high-quality images due to its ultra-high sensitivity. We compared the dynamic, regular static, and delayed 18F-fluorodeoxyglucose (FDG) scans to detect lesions in oncologic patients on a total-body PET/CT scanner. MATERIALS & METHODS: In all, 45 patients were scanned continuously for the first 60 min, followed by a delayed acquisition. FDG metabolic rate was calculated from dynamic data using full compartmental modeling, whereas regular static and delayed SUV images were obtained approximately 60- and 145-min post-injection, respectively. The retention index was computed from static and delayed measures for all lesions. Pearson's correlation and Kruskal-Wallis tests were used to compare parameters. RESULTS: The number of lesions was largely identical between the three protocols, except MRFDG and delayed images on total-body PET only detected 4 and 2 more lesions, respectively (85 total). FDG metabolic rate (MRFDG) image-derived contrast-to-noise ratio and target-to-background ratio were significantly higher than those from static standardized uptake value (SUV) images (P < 0.01), but this is not the case for the delayed images (P > 0.05). Dynamic protocol did not significantly differentiate between benign and malignant lesions just like regular SUV, delayed SUV, and retention index. CONCLUSION: The potential quantitative advantages of dynamic imaging may not improve lesion detection and differential diagnosis significantly on a total-body PET/CT scanner. The same conclusion applied to delayed imaging. This suggested the added benefits of complex imaging protocols must be weighed against the complex implementation in the future. CLINICAL RELEVANCE: Total-body PET/CT was known to significantly improve the PET image quality due to its ultra-high sensitivity. However, whether the dynamic and delay imaging on total-body scanner could show additional clinical benefits is largely unknown. Head-to-head comparison between two protocols is relevant to oncological management.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Diagnóstico Diferencial , Tomografia por Emissão de Pósitrons/métodos
14.
Quant Imaging Med Surg ; 14(1): 640-652, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223035

RESUMO

Background: Recently, deep learning techniques have been widely used in low-dose computed tomography (LDCT) imaging applications for quickly generating high quality computed tomography (CT) images at lower radiation dose levels. The purpose of this study is to validate the reproducibility of the denoising performance of a given network that has been trained in advance across varied LDCT image datasets that are acquired from different imaging systems with different spatial resolutions. Methods: Specifically, LDCT images with comparable noise levels but having different spatial resolutions were prepared to train the U-Net. The number of CT images used for the network training, validation and test was 2,400, 300 and 300, respectively. Afterwards, self- and cross-validations among six selected spatial resolutions (62.5, 125, 250, 375, 500, 625 µm) were studied and compared side by side. The residual variance, peak signal to noise ratio (PSNR), normalized root mean square error (NRMSE) and structural similarity (SSIM) were measured and compared. In addition, network retraining on a small number of image set was performed to fine tune the performance of transfer learning among LDCT tasks with varied spatial resolutions. Results: Results demonstrated that the U-Net trained upon LDCT images having a certain spatial resolution can effectively reduce the noise of the other LDCT images having different spatial resolutions. Regardless, results showed that image artifacts would be generated during the above cross validations. For instance, noticeable residual artifacts were presented at the margin and central areas of the object as the resolution inconsistency increased. The retraining results showed that the artifacts caused by the resolution mismatch can be greatly reduced by utilizing about only 20% of the original training data size. This quantitative improvement led to a reduction in the NRMSE from 0.1898 to 0.1263 and an increase in the SSIM from 0.7558 to 0.8036. Conclusions: In conclusion, artifacts would be generated when transferring the U-Net to a LDCT denoising task with different spatial resolution. To maintain the denoising performance, it is recommended to retrain the U-Net with a small amount of datasets having the same target spatial resolution.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38194393

RESUMO

Given the widespread occurrence of obesity, new strategies are urgently needed to prevent, halt and reverse this condition. We proposed a noninvasive neurostimulation tool, ultrasound deep brain stimulation (UDBS), which can specifically modulate the hypothalamus and effectively regulate food intake and body weight in mice. Fifteen-min UDBS of hypothalamus decreased 41.4% food intake within 2 hours. Prolonged 1-hour UDBS significantly decreased daily food intake lasting 4 days. UDBS also effectively restrained body weight gain in leptin-receptor knockout mice (Sham: 96.19%, UDBS: 58.61%). High-fat diet (HFD) mice treated with 4-week UDBS (15 min / 2 days) reduced 28.70% of the body weight compared to the Sham group. Meanwhile, UDBS significantly modulated glucose-lipid metabolism and decreased the body fat. The potential mechanism is that ultrasound actives pro-opiomelanocortin (POMC) neurons in the hypothalamus for reduction of food intake and body weight. These results provide a noninvasive tool for controlling food intake, enabling systematic treatment of obesity.


Assuntos
Estimulação Encefálica Profunda , Leptina , Camundongos , Animais , Leptina/metabolismo , Peso Corporal , Obesidade/terapia , Ingestão de Alimentos/fisiologia , Camundongos Endogâmicos C57BL
16.
Eur Radiol ; 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38265473

RESUMO

OBJECTIVE: Evaluation of tumor microvascular morphology is of great significance in tumor diagnosis, therapeutic effect prediction, and surgical planning. Recently, two-dimensional ultrasound localization microscopy (2DULM) has demonstrated its superiority in the field of microvascular imaging. However, it suffers from planar dependence and is unintuitive. We propose a novel three-dimensional ultrasound localization microscopy (3DULM) to avoid these limitations. METHODS: We investigated 3DULM based on a 2D array for tumor microvascular imaging. After intravenous injection of contrast agents, all elements of the 2D array transmit and receive signals to ensure a high and stable frame rate. Microbubble signal extraction, filtering, positioning, tracking, and other processing were used to obtain a 3D vascular map, flow velocity, and flow direction. To verify the effectiveness of 3DULM, it was validated on double helix tubes and rabbit VX2 tumors. Cisplatin was used to verify the ability of 3DULM to detect microvascular changes during tumor treatment. RESULTS: In vitro, the sizes measured by 3DULM at 3 mm and 13 mm were 178 [Formula: see text] and 182 [Formula: see text], respectively. In the rabbit tumors, we acquired 9000 volumes to reveal vessels about 30 [Formula: see text] in diameter, which surpasses the diffraction limit of ultrasound in traditional ultrasound imaging, and the results matched with micro-angiography. In addition, there were significant changes in vascular density and curvature between the treatment and control groups. CONCLUSIONS: The effectiveness of 3DULM was verified in vitro and in vivo. Hence, 3DULM may have potential applications in tumor diagnosis, tumor treatment evaluation, surgical protocol guidance, and cardiovascular disease. CLINICAL RELEVANCE STATEMENT: 3D ultrasound localization microscopy is highly sensitive to microvascular changes; thus, it has clinical potential for tumor diagnosis and treatment evaluation. KEY POINTS: • 3D ultrasound localization microscopy is demonstrated on double helix tubes and rabbit VX2 tumors. • 3D ultrasound localization microscopy can reveal vessels about 30 [Formula: see text] in diameter-far smaller than traditional ultrasound. • This form of imaging has potential applications in tumor diagnosis, tumor treatment evaluation, surgical protocol guidance, and cardiovascular disease.

17.
J Xray Sci Technol ; 32(1): 69-85, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38189729

RESUMO

BACKGROUND: Slow kVp switching technique is an important approach to realize dual-energy CT (DECT) imaging, but its performance has not been thoroughly investigated yet. OBJECTIVE: This study aims at comparing and evaluating the DECT imaging performance of different slow kVp switching protocols, and thus helps determining the optimal system settings. METHODS: To investigate the impact of energy separation, two different beam filtration schemes are compared: the stationary beam filtration and dynamic beam filtration. Moreover, uniform tube voltage modulation and weighted tube voltage modulation are compared along with various modulation frequencies. A model-based direct decomposition algorithm is employed to generate the water and iodine material bases. Both numerical and physical experiments are conducted to verify the slow kVp switching DECT imaging performance. RESULTS: Numerical and experimental results demonstrate that the material decomposition is less sensitive to beam filtration, voltage modulation type and modulation frequency. As a result, robust material-specific quantitative decomposition can be achieved in slow kVp switching DECT imaging. CONCLUSIONS: Quantitative DECT imaging can be implemented with slow kVp switching under a variety of system settings.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Algoritmos
18.
Artigo em Inglês | MEDLINE | ID: mdl-38206777

RESUMO

Ultrasound imaging offers a non-invasive, radiation-free method for visualizing internal tissues and organs, with deep penetration capabilities. This has established it as a crucial tool for physicians in diagnosing internal tissue pathologies and monitoring human conditions. Nonetheless, conventional ultrasound probes are often characterized by their rigidity and bulkiness. Designing a transducer that can seamlessly adapt to the contours and dynamics of soft, curved human skin presents significant technical hurdles. We present a novel flexible and stretchable ultrasound transducer (FSUT) designed for adaptability to large-curvature surfaces while preserving superior imaging quality. Central to this breakthrough is the innovative use of screen-printed silver nanowires (AgNWs) coupled with a composite elastic substrate, together ensuring robust and stable electrical and mechanical connections. Standard tensile and fatigue tests verify its durability. The mechanical, electrical and acoustic properties of FSUTs are characterised using standard methods, with large tensile strains (≥110%), high flexibility (R ≥1.4 mm) and light weight (≤1.58 g) to meet the needs of wearable devices. Center frequency and -6dB bandwidth are approximately 5.3MHz and 66.47%, respectively. Images of the commercial anechoic cyst phantom yielded an axial and lateral resolution (depths of 10 mm to 70 mm) of approximately 0.31mm and 0.46mm, 0.34mm and 0.84mm respectively. The complex curved surface imaging capabilities of FSUT were tested on agar-gelatin-based breast cyst phantoms under different curvatures. Finally, ultrasound images of the thyroid, brachial and carotid arteries were also obtained from volunteer wearing FSUT.

19.
IEEE Trans Med Imaging ; 43(4): 1554-1567, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38096101

RESUMO

The short frames of low-count positron emission tomography (PET) images generally cause high levels of statistical noise. Thus, improving the quality of low-count images by using image postprocessing algorithms to achieve better clinical diagnoses has attracted widespread attention in the medical imaging community. Most existing deep learning-based low-count PET image enhancement methods have achieved satisfying results, however, few of them focus on denoising low-count PET images with the magnetic resonance (MR) image modality as guidance. The prior context features contained in MR images can provide abundant and complementary information for single low-count PET image denoising, especially in ultralow-count (2.5%) cases. To this end, we propose a novel two-stream dual PET/MR cross-modal interactive fusion network with an optical flow pre-alignment module, namely, OIF-Net. Specifically, the learnable optical flow registration module enables the spatial manipulation of MR imaging inputs within the network without any extra training supervision. Registered MR images fundamentally solve the problem of feature misalignment in the multimodal fusion stage, which greatly benefits the subsequent denoising process. In addition, we design a spatial-channel feature enhancement module (SC-FEM) that considers the interactive impacts of multiple modalities and provides additional information flexibility in both the spatial and channel dimensions. Furthermore, instead of simply concatenating two extracted features from these two modalities as an intermediate fusion method, the proposed cross-modal feature fusion module (CM-FFM) adopts cross-attention at multiple feature levels and greatly improves the two modalities' feature fusion procedure. Extensive experimental assessments conducted on real clinical datasets, as well as an independent clinical testing dataset, demonstrate that the proposed OIF-Net outperforms the state-of-the-art methods.


Assuntos
Processamento de Imagem Assistida por Computador , Fluxo Óptico , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
20.
Eur J Nucl Med Mol Imaging ; 51(2): 346-357, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37782321

RESUMO

PURPOSE: Positron emission tomography/magnetic resonance imaging (PET/MRI) is a powerful tool for brain imaging, but the spatial resolution of the PET scanners currently used for brain imaging can be further improved to enhance the quantitative accuracy of brain PET imaging. The purpose of this study is to develop an MR-compatible brain PET scanner that can simultaneously achieve a uniform high spatial resolution and high sensitivity by using dual-ended readout depth encoding detectors. METHODS: The MR-compatible brain PET scanner, named SIAT bPET, consists of 224 dual-ended readout detectors. Each detector contains a 26 × 26 lutetium yttrium oxyorthosilicate (LYSO) crystal array of 1.4 × 1.4 × 20 mm3 crystal size read out by two 10 × 10 silicon photomultiplier (SiPM) arrays from both ends. The scanner has a detector ring diameter of 376.8 mm and an axial field of view (FOV) of 329 mm. The performance of the scanner including spatial resolution, sensitivity, count rate, scatter fraction, and image quality was measured. Imaging studies of phantoms and the brain of a volunteer were performed. The mutual interferences of the PET insert and the uMR790 3 T MRI scanner were measured, and simultaneous PET/MRI imaging of the brain of a volunteer was performed. RESULTS: A spatial resolution of better than 1.5 mm with an average of 1.2 mm within the whole FOV was obtained. A sensitivity of 11.0% was achieved at the center FOV for an energy window of 350-750 keV. Except for the dedicated RF coil, which caused a ~ 30% reduction of the sensitivity of the PET scanner, the MRI sequences running had a negligible effect on the performance of the PET scanner. The reduction of the SNR and homogeneity of the MRI images was less than 2% as the PET scanner was inserted to the MRI scanner and powered-on. High quality PET and MRI images of a human brain were obtained from simultaneous PET/MRI scans. CONCLUSION: The SIAT bPET scanner achieved a spatial resolution and sensitivity better than all MR-compatible brain PET scanners developed up to date. It can be used either as a standalone brain PET scanner or a PET insert placed inside a commercial whole-body MRI scanner to perform simultaneous PET/MRI imaging.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Humanos , Desenho de Equipamento , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas , Encéfalo/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...