Chinese Journal of Cardiology ; (12): 648-655, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-984698

RESUMO

Objective: To determine the feasibility of using temporary permanent pacemaker (TPPM) in patients with high-degree atrioventricular block (AVB) after transcatheter aortic valve replacement (TAVR) as bridging strategy to reduce avoidable permanent pacemaker implantation. Methods: This is a prospective observational study. Consecutive patients undergoing TAVR at Beijing Anzhen Hospital and the First Affiliated Hospital of Zhengzhou University from August 2021 to February 2022 were screened. Patients with high-degree AVB and TPPM were included. Patients were followed up for 4 weeks with pacemaker interrogation at every week. The endpoint was the success rate of TPPM removal and free from permanent pacemaker at 1 month after TPPM. The criteria of removing TPPM was no indication of permanent pacing and no pacing signal in 12 lead electrocardiogram (EGG) and 24 hours dynamic EGG, meanwhile the last pacemaker interrogation indicated that ventricular pacing rate was 0. Routinely follow-up ECG was extended to 6 months after removal of TPPM. Results: Ten patients met the inclusion criteria for TPPM, aged (77.0±11.1) years, wirh 7 females. There were 7 patients with third-degree AVB, 1 patient with second-degree AVB, 2 patients with first degree AVB with PR interval>240 ms and LBBB with QRS duration>150 ms. TPPM were applied on the 10 patients for (35±7) days. Among 8 patients with high-degree AVB, 3 recovered to sinus rhythm, and 3 recovered to sinus rhythm with bundle branch block. The other 2 patients with persistent third-degree AVB received permanent pacemaker implantation. For the 2 patients with first-degree AVB and LBBB, PR interval shortened to within 200 ms. TPPM was successfully removed in 8 patients (8/10) at 1 month without permanent pacemaker implantation, of which 2 patients recovered within 24 hours after TAVR and 6 patients recovered 24 hours later after TAVR. No aggravation of conduction block or permanent pacemaker indication were observed in 8 patients during follow-up at 6 months. No procedure-related adverse events occurred in all patients. Conclusion: TPPM is reliable and safe to provide certain buffer time to distinguish whether a permanent pacemaker is necessary in patients with high-degree conduction block after TAVR.


Assuntos
Feminino , Humanos , Bloqueio Atrioventricular/terapia , Estudos de Viabilidade , Substituição da Valva Aórtica Transcateter , Marca-Passo Artificial , Bloqueio de Ramo
2.
Chinese Journal of Cardiology ; (12): 990-994, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1045727

RESUMO

Objective: To explore the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the "All in One" single-artery/vessel technique. Methods: This is a retrospective study. A total of 30 consecutive patients underwent TAVR using the single artery/vascular technique in Beijing Anzhen Hospital from August to December 2021 were included. Baseline clinical data, operative situation, postoperative outcomes, and incidence of adverse events during hospitalization and at one month post TAVR were analyzed. Results: Mean age was (72.6±9.7) years, 16 were male patients, STS score was (4.73±3.12)%. Four patients were diagnosed as isolated aortic regurgitation (all with tricuspid aortic valves), and 26 patients were diagnosed as aortic stenosis (AS), 10 of whom with tricuspid aortic valves and 16 of whom with bicuspid aortic valves. The single-vessel technique was applied in 3 aortic stenosis cases; the single-artery technique was applied in 27 cases. Echocardiography was performed immediately after procedure and results showed no or trace perivalvular leak in 27 cases and small perivalvular leak in 3 cases; the mean aortic transvalvular gradient of 26 AS patients decreased from (50.4±16.0) mmHg (1 mmHg=0.133 kPa) to (9.4±3.2) mmHg (P<0.001). The procedure time was (64.8±18.9) min. There were no intraoperative death, valve displacement, conversion to surgery, coronary artery occlusion in all 30 patients. There were no major cardiac adverse events such as myocardial infarction or stroke occurred during hospitalization or at follow-up. One-month follow-up echocardiography indicated prosthesis works well. The symptoms were significantly alleviated, and the Kansas City Cardiomyopathy Score (KCCQ score) of all patients increased from 48.1±18.4 to 73.5±17.6 (P<0.001). Conclusions: TAVR using the single artery/vessel technique is safe and feasible. This technique is related to reduced access complications and worthy of wide application.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter , Estudos Retrospectivos , Artérias , Aorta , Estenose da Valva Aórtica/cirurgia
3.
Chinese Journal of Cardiology ; (12): 990-994, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1046050

RESUMO

Objective: To explore the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the "All in One" single-artery/vessel technique. Methods: This is a retrospective study. A total of 30 consecutive patients underwent TAVR using the single artery/vascular technique in Beijing Anzhen Hospital from August to December 2021 were included. Baseline clinical data, operative situation, postoperative outcomes, and incidence of adverse events during hospitalization and at one month post TAVR were analyzed. Results: Mean age was (72.6±9.7) years, 16 were male patients, STS score was (4.73±3.12)%. Four patients were diagnosed as isolated aortic regurgitation (all with tricuspid aortic valves), and 26 patients were diagnosed as aortic stenosis (AS), 10 of whom with tricuspid aortic valves and 16 of whom with bicuspid aortic valves. The single-vessel technique was applied in 3 aortic stenosis cases; the single-artery technique was applied in 27 cases. Echocardiography was performed immediately after procedure and results showed no or trace perivalvular leak in 27 cases and small perivalvular leak in 3 cases; the mean aortic transvalvular gradient of 26 AS patients decreased from (50.4±16.0) mmHg (1 mmHg=0.133 kPa) to (9.4±3.2) mmHg (P<0.001). The procedure time was (64.8±18.9) min. There were no intraoperative death, valve displacement, conversion to surgery, coronary artery occlusion in all 30 patients. There were no major cardiac adverse events such as myocardial infarction or stroke occurred during hospitalization or at follow-up. One-month follow-up echocardiography indicated prosthesis works well. The symptoms were significantly alleviated, and the Kansas City Cardiomyopathy Score (KCCQ score) of all patients increased from 48.1±18.4 to 73.5±17.6 (P<0.001). Conclusions: TAVR using the single artery/vessel technique is safe and feasible. This technique is related to reduced access complications and worthy of wide application.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter , Estudos Retrospectivos , Artérias , Aorta , Estenose da Valva Aórtica/cirurgia
4.
Chinese Journal of Cardiology ; (12): 563-569, 2022.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-940889

RESUMO

Objective: To summarize the single center experience of transcatheter aortic valve replacement (TAVR) with a simplified operative protocol. Methods: Consecutive patients who underwent transfemoral TAVR (TF-TAVR) from July 2020 to December 2020 in Fuwai Hospital were retrospectively analyzed. We compared the baseline characteristic, procedure information, 30-day follow-up outcomes of the patients who underwent TF-TAVR without the simplified operative protocol (routine group) or with the simplified operative protocol (simplified protocol group). Results: 93 patients were collected, 42 patients belonging to routine group, 51 patients belonging to simplified protocol group. In simplified protocol group, there were 51 patients planned to use ultrasound-guided femoral access puncture, procedure was successful in all 51 patients (100%). There were 49 patients planned to use the radial artery as the secondary access, procedure was successful in 45 patients (92%). There were 48 patients planned to use the strategy of avoidance of urinary catheter, this strategy was achieved in 35 patients (73%). There were 12 patients planned to use the left ventricular guidewire to pace, procedure was successful in 11 patients (92%). There were no differences in baseline characteristics, major clinical endpoints and 30-day follow-up outcomes between the two groups. Meanwhile, the procedure time ((62.5±17.9)min vs. (78.3±16.7)min, P<0.001), operation room time ((133.7±25.1)min vs. (159.2±42.6)min, P<0.001), X-ray exposure time ((17.2±6.5)min vs. (20.2±7.7)min, P=0.027) were significantly shorten in simplified protocol group compared with the routine group. Conclusion: Our study results indicate that the simplified operative protocol of TF-TAVR is as effective and safe as the routine operative protocol, meanwhile using the simplified operative protocol can significantly increase the operative efficiency of TF-TAVR.


Assuntos
Humanos , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-255021

RESUMO

<p><b>OBJECTIVE</b>For heart functional parameters, we commonly used normal range. The reference values and predict formulas of heart functional parameters and their relationships with individual characteristics are still lack.</p><p><b>METHODS</b>Left ventricular (LV) volumes (end-diastolic volume and end-systolic volume), stroke volume (SV), ejection fraction (EF) and cardiac output (CO) were measured by cardiac CT angiography (CAT) in 1 200 healthy Caucasian volunteers, men 807 and women 393, and age 20-90yr. The results are analyzed by high-accuracy three-dimensional imaging technology, and then measured the dynamic changes of the volumes of each atriam and ventricule during their contractions and relaxations. The gender, age, height and weight were analyzed by multiple linear regression to predict LV functional parameters.</p><p><b>RESULTS</b>Except the LVEF was lower in man than in women (P < 0.001), all other LV functional parameters of EDV, ESV, SV, FE and CO were higher in man (P < 0.001). Multiple linear regression indicated that age, gender, height and weight are all independent factors of EDV, ESV and SV (P < 0.001). CO could be significantly predicted by age, gender and weight (P < 0.001), but not height (P > 0.05). The predict equation for CO (L x min(-1)) = 6.963+0.446 (Male) -0.037 x age (yr) +0.013 x weight (kg).</p><p><b>CONCLUSION</b>Age, gender, height and weight are predictors of heart functions. The reference values and predict equations are important for noninvasive and accurate evaluation of cardiovascular disease and individualized treatment.</p>