Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 414(23): 6791-6800, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35931786

RESUMO

Folic acid (FA) is essential for human health, particularly for pregnant women and infants. In this work, a glassy carbon electrode (GCE) was modified by a bimetallic layer of Cu/Co nanoparticles (CuNPs/CoNPs) as a synergistic amplification element by simple step-by-step electrodeposition, and was used for sensitive detection of FA. The proposed CuNPs/CoNPs/GCE sensor was characterized by differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS) and field emission scanning electron microscopy (FESEM). Then, under optimal conditions, a linear relationship was obtained in the wide range of 110.00-1750.00 µM for the detection of FA with a limit of detection (LOD) of 34.79 µM (S/N = 3). The sensitivity was calculated as 0.096 µA µM-1 cm-2. Some interfering compounds including glucose (Glc), biotin, dopamine (DA), and glutamic acid (Glu) showed little effect on the detection of FA by amperometry (i-t). Finally, the average recovery obtained was in a range of 91.77-110.06%, with a relative standard deviation (RSD) less than 8.00% in FA tablets, indicating that the proposed sensor can accurately and effectively detect the FA content in FA tablets.


Assuntos
Carbono , Técnicas Eletroquímicas , Técnicas Eletroquímicas/métodos , Eletrodos , Feminino , Ácido Fólico , Humanos , Limite de Detecção , Gravidez , Comprimidos
2.
Food Chem ; 383: 132403, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35158131

RESUMO

Excessive intake of melamine (MEL) can be harmful to human health, and it is important to establish a rapid and accurate MEL detection method. As the electrochemical activity of MEL is very low, ferrocenylglutathione (Fc-ECG) was used as an electron transfer mediator to assist with the detection of MEL using screen-printed carbon electrode (SPCE). This modified electrode (MEL/Fc-ECG/SPCE) was prepared by stepwise drop-casting and was fully characterized. Results showed that MEL significantly enhanced signal of Fc-ECG/SPCE sensor due to the three p-π conjugated double bonds that facilitated electron transfer. Under optimal conditions, the sensor exhibits two linearities in the range of 0.20-2.00 µM and 8.00-800 µM, with a sensitivity of 15.03 µA·µM-1·cm-2. The selectivity, stability, and reproducibility were investigated and successfully used to detect MEL in raw milk and confirms safety verification of foods. Moreover, a portable testing platform was designed for MEL detection based on a CH32 chip.


Assuntos
Técnicas Eletroquímicas , Leite , Animais , Carbono/química , Técnicas Eletroquímicas/métodos , Eletrodos , Humanos , Leite/química , Reprodutibilidade dos Testes , Triazinas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...