Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Craniomaxillofac Surg ; 52(4): 397-405, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458893

RESUMO

This study aimed to evaluate the feasibility and accuracy of a combined virtual surgical planning (VPS) and short-segment drilling guides (SSDGs) workflow for the treatment of complex mandibular fractures. Consecutive patients with complex mandibular fractures underwent treatment using the VPS and SSDGs workflow from August 2020 to April 2022. Various mandibular landmarks were compared between the preoperative virtual surgical plan and postoperative data, including condylar distance (CoD), mandibular angle width (GoL-GoR), GoMeGo angle (∠GoL-Me-GoR), the difference in mandibular angles between the left and right sides (Δ∠Co-Go-Me), and the difference in length between the left and right mandibular body (ΔGo-Me). Additionally, preoperative preparation time and surgical duration were retrospectively analyzed and compared to conventional surgery. All 14 consecutive patients with complex mandibular fractures achieved successful reduction using the VPS and SSDGs workflow. Three-dimensional comparison revealed a mean deviation distance of 0.91 ± 0.50 mm and a root-mean-square deviation of 1.75 ± 0.47 mm between the preoperative designed mandible model and the postoperative mandible model. The percentage of points with deviation distances less than 2 mm, 1 mm, and 0.5 mm between preoperative and postoperative models were 78.47 ± 8.87 %, 60.02 ± 14.28 %, and 38.64 ± 15.48 %, respectively. There were no significant differences observed in CoD, GoL-GoR, ∠GoL-Me-GoR, Δ∠Co-Go-Me, and ΔGo-Me between preoperative virtual surgical planning and postoperative measurements. Furthermore, no significant differences were found in the injury-to-surgery interval, admission-to-surgery interval, and surgical duration between the workflow and conventional surgery. The combined VPS and SSDGs workflow proved to be an accurate and feasible method for treating complex mandibular fractures. It offers advantages such as minimal preoperative preparation time and the ability to precise transfer screw positions of the pre-bent reconstruction plate during surgery. This approach is particularly suitable for managing complex mandibular fractures.


Assuntos
Fraturas Mandibulares , Reconstrução Mandibular , Cirurgia Assistida por Computador , Humanos , Fraturas Mandibulares/diagnóstico por imagem , Fraturas Mandibulares/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Cirurgia Assistida por Computador/métodos , Mandíbula/cirurgia , Reconstrução Mandibular/métodos
2.
Eur Radiol ; 32(2): 1087-1094, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34347158

RESUMO

OBJECTIVE: To evaluate the influence of post-label delay times (PLDs) on the performance of 3D pseudo-continuous arterial spin labeling (pCASL) magnetic resonance imaging for characterizing parotid gland tumors and to explore the optimal PLDs for the differential diagnosis. MATERIALS AND METHOD: Fifty-eight consecutive patients with parotid gland tumors were enrolled, including 33 patients with pleomorphic adenomas (PAs), 16 patients with Warthin's tumors (WTs), and 9 patients with malignant tumors (MTs). 3D pCASL was scanned for each patient five times, with PLDs of 1025 ms, 1525 ms, 2025 ms, 2525 ms, and 3025 ms. Tumor blood flow (TBF) was calculated, and compared among different PLDs and tumor groups. Performance of TBF at different PLDs was evaluated using receiver operating characteristic analysis. RESULTS: With an increasing PLD, TBF tended to gradually increase in PAs (p < 0.001), while TBF tended to slightly increase and then gradually decrease in WTs (p = 0.001), and PAs showed significantly lower TBF than WTs at all 5 PLDs (p < 0.05). PAs showed significantly lower TBF than MTs at 4 PLDs (p < 0.05), except at 3025 ms (p = 0.062). WTs showed higher TBF than MTs at all 5 PLDs; however, differences did not reach significance (p > 0.05). Setting a TBF of 64.350 mL/100g/min at a PLD of 1525 ms, or a TBF of 23.700 mL/100g/min at a PLD of 1025 ms as the cutoff values, optimal performance could be obtained for differentiating PAs from WTs (AUC = 0.905) or from MTs (AUC = 0.872). CONCLUSIONS: Short PLDs (1025 ms or 1525 ms) are suggested to be used in 3D pCASL for characterizing parotid gland tumors in clinical practice. KEY POINTS: • With 5 different PLDs, 3D pCASL can reflect the variation of blood flow in parotid gland tumors. • 3D pCASL is useful for characterizing PAs from WTs or MTs. • Short PLDs (1025 ms or 1525 ms) are suggested to be used in 3D pCASL for characterizing parotid gland tumors in clinical practice.


Assuntos
Adenolinfoma , Adenoma Pleomorfo , Neoplasias Parotídeas , Adenolinfoma/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Glândula Parótida , Neoplasias Parotídeas/diagnóstico por imagem , Marcadores de Spin
3.
BMC Med Imaging ; 20(1): 93, 2020 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-32762734

RESUMO

BACKGROUND: To evaluate the feasibility of using simultaneous multi-slice (SMS) readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) to assess parotid gland tumors, compared with conventional RESOLVE DWI. METHODS: From September 2018 to December 2018, 20 consecutive patients with parotid tumors who underwent MRI scan for pre-surgery evaluation were enrolled. SMS-RESOLVE DWI and conventional RESOLVE DWI were scanned with matched imaging parameters, respectively. The scan time of two DWI sequences was recorded. Qualitative (anatomical structure differentiation, lesion display, artifact, and overall image quality) and quantitative (apparent diffusion coefficient, ADC; ratio of signal-to-noise ratio, SNR ratio; ratio of contrast-to-noise ratio, CNR ratio) assessments of image quality were performed, and compared between SMS-RESOLVE DWI and conventional RESOLVE DWI by using Paired t-test. Two-sided P value less than 0.05 indicated significant difference. RESULTS: The scan time was 3 min and 41 s for SMS-RESOLVE DWI, and 5 min and 46 s for conventional RESOLVE DWI. SMS-RESOLVE DWI produced similar qualitative image quality with RESOLVE DWI (anatomical structure differentiation, P = 0.164; lesion display, P = 0.193; artifact, P = 0.330; overall image quality, P = 0.083). Meanwhile, there were no significant difference on ADCLesion (P = 0.298), ADCMasseter (P = 0.122), SNR ratio (P = 0.584) and CNR ratio (P = 0.217) between two DWI sequences. CONCLUSION: Compared with conventional RESOLVE DWI, SMS-RESOLVE DWI could provide comparable image quality using markedly reduced scan time. SMS could increase the clinical usability of RESOLVE technique for DWI of parotid gland.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Neoplasias Parotídeas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores de Tempo
4.
Br J Radiol ; 93(1113): 20200052, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32649236

RESUMO

OBJECTIVE: To evaluate the feasibility of using imaging parameters (D, ß and µ) obtained from fractional order calculus (FROC) diffusion model to differentiate salivary gland tumors. METHODS: 15 b-value (0-2000 s/mm2) diffusion-weighted imaging (DWI) was scanned in 62 patients with salivary gland tumors (47 benign and 15 malignant). Diffusion coefficient D, fractional order parameter ß (which correlates with tissue heterogeneity) and a microstructural quantity µ of the solid portion within the tumor were calculated, and compared between benign and malignant groups, or among pleomorphic adenoma (PA), Warthin's tumor (WT), and malignant tumor (MT) groups. Performance of FROC parameters for differentiation was assessed using receiver operating characteristic analysis. RESULTS: None of the FROC parameters exhibited significant differences between benign and malignant group (D, p = 0.150; ß, p = 0.967; µ, p = 0.693). WT showed significantly lower D (p < 0.001) and ß (p < 0.001), while higher µ (p = 0.001) than PA. Combination of D, ß and µ showed optimal diagnostic performance (area under the curve, AUC, 0.998). MT showed significantly lower D (p = 0.001) and ß (p = 0.025) than PA, while no significant difference was found on µ (p = 0.064). Combination of D and ß showed optimal diagnostic performance (AUC, 0.933). Significant difference was found on ß (p = 0.027) between MT and WT, while not on D (p = 0.806) and µ (p = 0.789). Setting a ßof 0.615 as the cut-off value, optimal diagnostic performance could be obtained (AUC = 0.806). CONCLUSION: A non-Gaussian FROC diffusion model can serve as a noninvasive and quantitative imaging technique for differentiating salivary gland tumors. ADVANCES IN KNOWLEDGE: (1) PA showed higher D and ß and lower µ than WT. (2) PA had higher D and ß than MT. (3) WT demonstrated lower ß than MT. (4) ß, as a new FROC parameter, could offer an added value to the differentiation.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias das Glândulas Salivares/diagnóstico por imagem , Adenolinfoma/diagnóstico por imagem , Adenolinfoma/patologia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Algoritmos , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Neoplasias das Glândulas Salivares/patologia
5.
Eur Arch Otorhinolaryngol ; 277(10): 2839-2846, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32328768

RESUMO

PURPOSE: To assess the added value of susceptibility-weighted imaging (SWI) to diffusion-weighted imaging (DWI) in the characterization of parotid gland tumors. METHODS: Seventy-eight patients with pathologically confirmed parotid gland tumors, who underwent DWI and SWI for pre-surgery evaluation, were enrolled. Apparent diffusion coefficient (ADC) and degree of intratumoral susceptibility signal intensity (ITSS) were measured and compared between benign and malignant groups, and among pleomorphic adenoma (PA), Warthin tumor (WT) and malignant tumor (MT). Independent sample t test, one-way analysis of variance and receiver operating characteristic curve analysis were used for statistical analyses. RESULTS: Benign parotid gland tumor showed a significantly higher mean ADC value than malignant tumors (0.836 ± 0.350 vs 0.592 ± 0.163, p = 0.001). Setting an average ADC value of 0.679 as the cut-off value, optimal differentiating performance could be obtained (AUC, 0.700; sensitivity, 62.69%; specificity, 81.82%) for differentiating malignant from benign tumors. PA showed significantly higher mean ADC and less ITSS than WT (ADC, p < 0.001; ITSS, p = 0.033) and MT (ADC, p < 0.001; ITSS, p = 0.024), while the difference between WT and MT was not significant (ADC, p = 0.826; ITSS, p = 0.539). After integration with ITSS, the diagnostic performance of ADC was improved for differentiating PA from WT (AUC 0.921 vs 0.873) and from MT (AUC 0.906 vs 0.882). CONCLUSION: SWI could provide added information to DWI and serve as a supplementary imaging marker for the characterization of parotid gland tumors.


Assuntos
Glândula Parótida , Neoplasias Parotídeas , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética , Humanos , Glândula Parótida/diagnóstico por imagem , Neoplasias Parotídeas/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Eur Arch Otorhinolaryngol ; 275(8): 2151-2157, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29961924

RESUMO

PURPOSE: To evaluate the diagnostic performance of histogram parameters derived from diffusion-weighted imaging (DWI) for differentiating malignant from benign parotid gland tumors compared with that of hotspot region of interest (ROI)-based apparent diffusion coefficient (ADC) measurement. METHODS: Our study retrospectively enrolled 60 patients with parotid gland tumors who had undergone DWI scan for pre-treatment evaluation. ADC measurements were performed using hotspot ROI (ADCHS-ROI)-based and histogram-based approach. Histogram parameters included mean (ADCmean), median (ADCmedian), 10th (ADC10), 90th (ADC90) percentiles, skewness and kurtosis of ADC. Mann-Whitney U test, Kruskal-Wallis test with post hoc Dunn-Bonferroni method and receiver operating characteristic (ROC) curve analyses were used for statistical analyses. RESULTS: ADCHS-ROI and ADC histogram parameters showed no significant differences between malignant and benign parotid gland tumors (All Ps > 0.05). Within the sub-group analyses, Warthin's tumors showed the lowest ADCHS-ROI, ADCmean, ADCmedian, ADC10 and ADC90 value, followed by malignant tumors and pleomorphic adenomas (All Ps < 0.05). ADC10 out-performed ADCHS-ROI in differentiating malignant tumors from pleomorphic adenomas (area under curve, 0.890 vs 0.821; sensitivity, 79.31 vs 82.76%; specificity, 90.91 vs 72.73%; P = 0.016), and improved the diagnostic performance in differentiating malignant tumors from Warthin's tumors (area under curve, 1.000 vs 0.965; sensitivity, 100.00 vs 90.91%), although the difference was not significant (P = 0.348). CONCLUSIONS: ADC histogram analysis, especially ADC10, might be a promising imaging biomarker for characterizing parotid gland tumors.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Glândula Parótida/diagnóstico por imagem , Neoplasias Parotídeas/diagnóstico , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Parotídeas/diagnóstico , Curva ROC , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA