Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Bioeng Biotechnol ; 11: 957458, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36741762

RESUMO

Introduction: Synthetic vascular grafts perform poorly in small-caliber (<6mm) anastomoses, due to intimal hyperplasia and thrombosis, whereas homografts are associated with limited availability and immunogenicity, and bioprostheses are prone to aneurysmal degeneration and calcification. Infection is another important limitation with vascular grafting. This study developed a dual-component graft for small-caliber reconstructions, comprising a decellularized tibial artery scaffold and an antibiotic-releasing, electrospun polycaprolactone (PCL)/polyethylene glycol (PEG) blend sleeve. Methods: The study investigated the effect of nucleases, as part of the decellularization technique, and two sterilization methods (peracetic acid and γ-irradiation), on the scaffold's biological and biomechanical integrity. It also investigated the effect of different PCL/PEG ratios on the antimicrobial, biological and biomechanical properties of the sleeves. Tibial arteries were decellularized using Triton X-100 and sodium-dodecyl-sulfate. Results: The scaffolds retained the general native histoarchitecture and biomechanics but were depleted of glycosaminoglycans. Sterilization with peracetic acid depleted collagen IV and produced ultrastructural changes in the collagen and elastic fibers. The two PCL/PEG ratios used (150:50 and 100:50) demonstrated differences in the structural, biomechanical and antimicrobial properties of the sleeves. Differences in the antimicrobial activity were also found between sleeves fabricated with antibiotics supplemented in the electrospinning solution, and sleeves soaked in antibiotics. Discussion: The study demonstrated the feasibility of fabricating a dual-component small-caliber graft, comprising a scaffold with sufficient biological and biomechanical functionality, and an electrospun PCL/PEG sleeve with tailored biomechanics and antibiotic release.

2.
Crit Rev Biotechnol ; 36(4): 705-15, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25739987

RESUMO

Whole-organ decellularization and tissue engineering approaches have made significant inroads during recent years. If proven to be successful and clinically viable, it is highly likely that this field would be poised to revolutionize organ transplantation surgery. In particular, whole-heart decellularization has captured the attention and imagination of the scientific community. This technique allows for the generation of a complex three-dimensional (3D) extracellular matrix scaffold, with the preservation of the intrinsic 3D basket-weave macroarchitecture of the heart itself. The decellularized scaffold can then be recellularized by seeding it with cells and incubating it in perfusion bioreactors in order to create functional organ constructs for transplantation. Indeed, research into this strategy of whole-heart tissue engineering has consequently emerged from the pages of science fiction into a proof-of-concept laboratory undertaking. This review presents current trends and advances, and critically appraises the concepts involved in various approaches to whole-heart decellularization and tissue engineering.


Assuntos
Coração/fisiologia , Alicerces Teciduais , Animais , Transplante de Coração , Humanos , Regeneração , Engenharia Tecidual
3.
Tissue Cell ; 44(6): 365-72, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22770869

RESUMO

Stainless steel (SS) is one of the most applicable materials in fabrication of cardiac implants. The aim of this study is to investigate the effect of atomic structure of polycrystalline stainless steel on the response of adipose tissue-derived stem cells (ADSCs). Samples are prepared from differently processed extruded rod and rolled sheet of 316L SS having different crystallographic structure. X-ray diffraction analysis indicated (200) and (111) orientations with distinct volume fractions in the specimens. Morphology and ADSCs behavior including adhesion, proliferation and differentiation are assessed. The expression of cardiac specific protein (cardiac troponin I) and genes of differentiating cardiomyocytes is analyzed by immunofluorescence and RT-PCR. The number of attached and grown cells on the rod sample is higher than the sheet sample also the scanning electron microscopy (SEM) analysis of ADSCs grown on the samples demonstrates higher cell density and spreading pattern on the surface of rod sample. In differentiated ADSCs on the rod sample the expression of all genes except ANF are detectable, while on the sheet sample only the MEF2C and ß-MHC are expressed. This study shows that the cellular response is influenced by the crystal structure of the substrate therefore; the skill to alter the structure of substrate may lend itself to engineer a biomaterial which could be suitable for differentiation of stem cells into a definite lineage.


Assuntos
Tecido Adiposo/citologia , Aço Inoxidável/farmacologia , Células-Tronco/citologia , Células-Tronco/efeitos dos fármacos , Animais , Adesão Celular/efeitos dos fármacos , Contagem de Células , Diferenciação Celular/efeitos dos fármacos , Diferenciação Celular/genética , Proliferação de Células/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Regulação da Expressão Gênica/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos BALB C , Microscopia de Força Atômica , Miocárdio/metabolismo , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Células-Tronco/metabolismo , Células-Tronco/ultraestrutura , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...