1.
Invest Ophthalmol Vis Sci ; 54(13): 7854-64, 2013 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-24168991

RESUMO

PURPOSE: A new 355 nm UV laser was used for corneal flap cutting in an animal model and tested for clinical and morphologic alterations. METHODS: Corneal flaps were created (Chinchilla Bastards; n = 25) with an UV nanosecond laser at 355 nm (150 kHz, pulse duration 850 ps, spot-size 1 µm, spot spacing 6 × 6 µm, side cut Δz 1 µm; cutting depth 130 µm) and pulse energies of 2.2 or 2.5 µJ, respectively. Following slit-lamp examination, animals were killed at 6, 12, and 24 hours after treatment. Corneas were prepared for histology (hematoxylin and eosin [HE], TUNEL-assay) and evaluated statistically, followed by ultrastructural investigations. RESULTS: Laser treatment was tolerated well, flap lift was easier at 2.5 µJ compared with 2.2 µJ. Standard HE at 24 hours revealed intact epithelium in the horizontal cut, with similar increase in corneal thickness at both energies. Irrespective of energy levels, TUNEL assay revealed comparable numbers of apoptotic cells in the horizontal and vertical cut at 6, 12, and 24 hours, becoming detectable in the horizontal cut as an acellular stromal band at 24 hours. Ultrastructural analysis revealed regular morphology in the epi- and endothelium, while in the stroma, disorganized collagen lamellae were detectable representing the horizontal cut, again irrespective of energy levels applied. CONCLUSIONS: This new UV laser revealed no epi- nor endothelial damage at energies feasible for corneal flap cutting. Observed corneal swelling was lower compared with existing UV laser studies, albeit total energy applied here was much higher. Observed loss of stromal keratinocytes is comparable with available laser systems. Therefore, this new laser is suitable for refractive surgery, awaiting its test in a chronic environment.


Assuntos
Córnea/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Retalhos Cirúrgicos , Animais , Apoptose , Contagem de Células , Córnea/patologia , Modelos Animais de Doenças , Epitélio Corneano/ultraestrutura , Marcação In Situ das Extremidades Cortadas , Microscopia Eletrônica de Transmissão , Miopia/patologia , Coelhos , Resultado do Tratamento
2.
J Acoust Soc Am ; 130(3): 1515-29, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21895091

RESUMO

The envelope shape is important for the perception of interaural time difference (ITD) in the envelope as supported by the improved sensitivity for transposed tones compared to sinusoidally amplitude-modulated (SAM) tones. The present study investigated the effects of specific envelope parameters in nine normal-hearing (NH) and seven cochlear-implant (CI) listeners, using high-rate carriers with 27-Hz trapezoidal modulation. In NH listeners, increasing the off time (the silent interval in each modulation cycle) up to 12 ms, increasing the envelope slope from 6 to 8 dB/ms, and increasing the peak level improved ITD sensitivity. The combined effect of the off time and slope accounts for the gain in sensitivity for transposed tones relative to SAM tones. In CI listeners, increasing the off time up to 20 ms improved sensitivity, but increasing the slope showed no systematic effect. A 27-pulses/s electric pulse train, representing a special case of modulation with infinitely steep slopes and maximum possible off time, yielded considerably higher sensitivity compared to the best condition with trapezoidal modulation. Overall, the results of this study indicate that envelope-ITD sensitivity could be improved by using CI processing schemes that simultaneously increase the off time and the peak level of the signal envelope.


Assuntos
Vias Auditivas/fisiopatologia , Implante Coclear/instrumentação , Implantes Cocleares , Correção de Deficiência Auditiva/psicologia , Pessoas com Deficiência Auditiva/reabilitação , Percepção da Altura Sonora , Estimulação Acústica , Adulto , Idoso , Audiometria , Limiar Auditivo , Estudos de Casos e Controles , Sinais (Psicologia) , Estimulação Elétrica , Humanos , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva/psicologia , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Fatores de Tempo , Adulto Jovem