Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Image Anal ; 97: 103265, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-39029158

RESUMO

Acute coronary syndromes (ACS) are one of the leading causes of mortality worldwide, with atherosclerotic plaque rupture and subsequent thrombus formation as the main underlying substrate. Thrombus burden evaluation is important for tailoring treatment therapy and predicting prognosis. Coronary optical coherence tomography (OCT) enables in-vivo visualization of thrombus that cannot otherwise be achieved by other image modalities. However, automatic quantification of thrombus on OCT has not been implemented. The main challenges are due to the variation in location, size and irregularities of thrombus in addition to the small data set. In this paper, we propose a novel dual-coordinate cross-attention transformer network, termed DCCAT, to overcome the above challenges and achieve the first automatic segmentation of thrombus on OCT. Imaging features from both Cartesian and polar coordinates are encoded and fused based on long-range correspondence via multi-head cross-attention mechanism. The dual-coordinate cross-attention block is hierarchically stacked amid convolutional layers at multiple levels, allowing comprehensive feature enhancement. The model was developed based on 5,649 OCT frames from 339 patients and tested using independent external OCT data from 548 frames of 52 patients. DCCAT achieved Dice similarity score (DSC) of 0.706 in segmenting thrombus, which is significantly higher than the CNN-based (0.656) and Transformer-based (0.584) models. We prove that the additional input of polar image not only leverages discriminative features from another coordinate but also improves model robustness for geometrical transformation.Experiment results show that DCCAT achieves competitive performance with only 10% of the total data, highlighting its data efficiency. The proposed dual-coordinate cross-attention design can be easily integrated into other developed Transformer models to boost performance.

2.
J Clin Med ; 13(10)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38792463

RESUMO

Primary percutaneous coronary intervention (pPCI) has revolutionized the prognosis of ST-segment elevation myocardial infarction (STEMI) and is the gold standard treatment. As a result of its success, the number of pPCI centres has expanded worldwide. Despite decades of advancements, clinical outcomes in STEMI patients have plateaued. Out-of-hospital cardiac arrest and cardiogenic shock remain a major cause of high in-hospital mortality, whilst the growing burden of heart failure in long-term STEMI survivors presents a growing problem. Many elements aiming to optimize STEMI treatment are still subject to debate or lack sufficient evidence. This review provides an overview of the most contentious current issues in pPCI in STEMI patients, with an emphasis on unresolved questions and persistent challenges.

3.
Heart ; 110(1): 27-34, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37414524

RESUMO

OBJECTIVE: The European Society of Cardiology guidelines have recently defined new cut-offs for pulmonary hypertension (PH) and pulmonary vasculature resistance (PVR; median pulmonary artery pressure (mPAP) >20 instead of 25 mm Hg and PVR >2 instead of 3 Wood unit). The prognostic value of this updated classification after transcatheter aortic valve implantation (TAVI) is unknown. METHODS: 579 consecutive patients treated by TAVI with preprocedural right heart catheterisation evaluation were included. Patients were grouped as: (1) no PH, (2) isolated precapillary/combined (I-PreC/Co) PH and (3) isolated postcapillary PH (I-PoC). All-cause death, cardiovascular death and hospitalisations for heart failure (HF) were evaluated at follow-up. We also analysed the prognostic role of residual postprocedural PH. RESULTS: Out of 579 patients, 299 (52%) had PH according to the new criteria compared with 185 (32%) according to the previous ones. Overall median age was 82 years, while 55.3% patients were male. Patients with PH were more frequently diagnosed with chronic obstructive pulmonary disease and atrial fibrillation and were characterised by higher surgical risk as compared with patients without PH.At a median follow-up of 2.9 years, the presence of PH according to previous definition was associated with worse survival (p<0.001) and HF hospitalisation (p=0.002) rates, irrespective of PVR values. With newer cut-offs, PH was associated with worse outcomes only in patients with increased PVR, while no differences were found between patients with PH and normal PVR values and those without PH. Postprocedural mPAP normalisation was observed in 45% of the cases, but it was associated with improved long-term survival only in the I-PoC PH group. CONCLUSIONS: New ESC PH cut-offs increased the number of PH diagnoses. The presence of PH, particularly in the setting of increased PVR, identify patients at higher risk for postprocedural mortality and rehospitalisation. Normalisation of PH was associated with better survival only in I-PoC group.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Prognóstico , Resultado do Tratamento , Fatores de Risco
4.
Front Cardiovasc Med ; 9: 1056496, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36578836

RESUMO

Objectives: To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Background: Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. Methods: The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Results: Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Conclusion: Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.

5.
Front Cardiovasc Med ; 9: 924958, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35757343

RESUMO

Background: The impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation. Methods: Consecutive patients with at least 5-years follow-up following TAVR for severe symptomatic aortic stenosis from June 2007 to December 2016 were included. Bioprosthetic valve failure (BVF) and hemodynamic valve deterioration (HVD) were defined according to VARC-3 updated definitions and estimated using cumulative incidence function to account for the competing risk of death. Results: A total of 604 patients (82 years; 53% female) were analyzed and divided into IA (482) and SA (122) groups. Overall survival rates at 10-years were similar (IA 15%, 95%CI: 10-22; SA 11%, 95%CI: 6-20; p = 0.21). Compared to the SA TAVR, mean transaortic gradients were significantly higher and increased over time in the IA group. IA TAVRs showed higher 10-year cumulative incidences of BVF (IA 8% vs. SA 1%, p = 0.02) and severe HVD (IA 5% vs. SA 1%, p = 0.05). The occurrence of BVF and HVD in the IA group occurred primarily in the smallest TAVR devices (20-23-mm). After excluding these sizes, the cumulative incidences of BVF (IA 5% vs. SA 1%, p = 0.40) and severe HVD (IA 2% vs. SA 1%, p = 0.11) were similar. Conclusion: In this study, TAVR leaflet design had no impact on survival at 10-years. IA devices showed higher transaortic gradients and cumulative incidences of HVD and BVF predominantly occurring in the smallest valve sizes.

6.
Front Cardiovasc Med ; 9: 832242, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35295263

RESUMO

Backgrounds: Among vascular closure devices (VCDs), the novel collagen plug-based MANTA VCD is the first designed for large bore percutaneous access. We aimed to assess the features and predictors of access-site vascular complications in an unselected trans-femoral transcatheter aortic valve replacement (TF-TAVR) population. Methods: Patients undergoing large bore arteriotomy closure with 18F MANTA VCD following TF-TAVR at a large tertiary care center from September 2019 to January 2021 were prospectively analyzed. Primary Outcome was the MANTA VCD access-site-related complications according to Valve Academic Research Consortium-3 (VARC) definitions. Its incidence and predictors were evaluated. Results: Eighty-eight patients (median age 82 years, 48% male, 3.3 median Society of Thoracic Surgeons score) undergoing TF-TAVR were included, mostly (63%) treated with a self-expandable device and with outer diameter sizes varied from 18F to 24-F. MANTA VCD technical success rate was 98%, while 10 patients (11%) experienced MANTA VCD access-site vascular complications which included 8% of minor complications and only to 2% of major events resulting in VARC type ≥2 bleeding. Vessel occlusion/stenosis (60%), perforation (20%), and pseudoaneurysm/dissection/hematoma (20%) occurred, but all were managed without surgical treatment. Independent predictors of failure were age (p = 0.04), minimum common femoral artery diameter (CFA) (p < 0.01), sheath-to-femoral-artery ratio (SFAR) (p < 0.01), and a lower puncture height (p = 0.03). A CFA diameter <7.1 mm with a SFAR threshold of 1.01 were associated with VCD failure. Conclusions: In a more comers TF-TAVR population, MANTA VCD was associated with reassuring rates of technical success and major access-site vascular complications. Avoiding lower vessel size and less puncture site distance to CFA bifurcation might further improve outcomes.

8.
J Sleep Res ; 30(4): e13234, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33260265

RESUMO

Alteration of the circadian sleep-wake rhythm has been suggested in patients affected by idiopathic rapid eye movement sleep behaviour disorder. Because actigraphy is the validated instrument to monitor the sleep-wake cycle, the aim of the present study was to investigate the circadian sleep-wake rhythm in patients with idiopathic rapid eye movement sleep behaviour disorder compared with healthy aged controls. Fourteen-day actigraphic recording, a comprehensive sleep interview, and cognitive and behavioural domains were investigated in patients affected by idiopathic rapid eye movement sleep behaviour disorder, and compared with controls similar for age, sex and cognitive performances. Patients with idiopathic rapid eye movement sleep behaviour disorder showed reduced relative amplitude and alteration of both sleep and wake compared with controls. Patients with idiopathic rapid eye movement sleep behaviour disorder also showed subjective sleep and wake complaints, and higher scores at the Beck Depression Inventory, compared with controls. Beck Depression Inventory scores correlated with sleep actigraphic parameters, such as sleep latency, sleep efficiency, time in bed, and relative amplitude. Therefore, the present study showed the dysregulation of the sleep-wake cycle in patients with idiopathic rapid eye movement behaviour disorder. Moreover, depressive symptoms documented in patients with idiopathic rapid eye movement sleep behaviour disorder correlated with the sleep-wake rhythm dysregulation.


Assuntos
Transtorno do Comportamento do Sono REM/fisiopatologia , Sono , Vigília , Actigrafia , Idoso , Feminino , Humanos , Masculino , Polissonografia , Transtorno do Comportamento do Sono REM/diagnóstico , Sono REM
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA