Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Skeletal Radiol ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713225

RESUMO

OBJECTIVE: No consensus exists for tumor volume response criteria in patients with Ewing sarcoma. This study aimed to identify an optimal cutoff for predicting a good histological response by analyzing tumor volume changes and tumor necrosis after neoadjuvant chemotherapy. MATERIALS AND METHODS: We performed a retrospective analysis of 184 Ewing sarcoma patients, analyzing tumor volume changes before and after neoadjuvant chemotherapy. Patients were divided into two groups based on histological response: good (tumor necrosis ≥ 95%) and poor (tumor necrosis < 95%) responders. The receiver operating characteristic (ROC) area under the curve (AUC) method was used to determine the optimal thresholds for predicting the histological response. Additionally, the prognostic value of this cutoff for relapse-free survival was assessed. RESULTS: Out of 184 patients, 83 (45%) had tumor necrosis ≥ 95%, while 101 (55%) had tumor necrosis < 95%. ROC analysis identified the optimal cutoff for a good histological response as over 65% tumor volume reduction (AUC = 0.69; p < 0.001). Patients with volume reduction of ≥ 65% had a higher likelihood of a good histological response than those with lesser reductions (p = 0.004; odds ratio = 2.61). Multivariable analysis indicated a correlation between poor histological response and reduced relapse-free survival (hazard ratio = 2.17; p = 0.01), while tumor volume reduction itself did not impact survival. CONCLUSION: We reported that a tumor volume reduction of ≥ 65% was able to predict a good histological response in Ewing sarcoma patients. We recommend preoperative tumor volume assessment to identify patients at greater risk for poor histological response who could benefit from more intensive chemotherapy protocols or additional radiotherapy.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38642876

RESUMO

BACKGROUND: Several reconstruction methods exist for Malawer type I/V proximal humerus reconstruction after bone tumor resection; however, no consensus has been reached regarding the preferred methods. METHODS: We conducted a literature search on various types of proximal humerus oncologic reconstruction methods. We collected data on postoperative functional outcomes assessed based on Musculoskeletal Tumor Society (MSTS) scores, 5-year reconstruction survival rates, and complications. We calculated each reconstruction's weighted mean based on the sample size and standard errors. Complications were categorized based on the Henderson classification. Based on these integrated data, our primary objective is to propose an optimal strategy for proximal humerus reconstruction after bone tumor resection. RESULTS: We examined various reconstruction techniques, including modular prosthesis (752 patients in 21 articles), osteoarticular allograft (142 patients in six articles), allograft prosthesis composites (236 patients in 12 articles), reverse shoulder total arthroplasty (141 patients in 10 articles), composite reverse shoulder total arthroplasty (33 patients in four articles), claviculo-pro-humero technique (51 patients in six articles), and cement spacer (207 patients in four articles). Weighted mean MSTS scores were: modular prosthesis (73.8%), osteoarticular allograft (74.4%), allograft prosthesis composites (79.2%), reverse shoulder total arthroplasty (77.0%), composite reverse shoulder total arthroplasty (76.1%), claviculo-pro-humero technique (75.1%), and cement spacer (69.1%). Weighted 5-year reconstruction survival rates were modular prosthesis (85.4%), osteoarticular allograft (67.6%), allograft prosthesis composites (85.2%), reverse shoulder total arthroplasty (84.1%), and cement spacer (88.0%). Reconstruction survival data was unavailable for composite reverse shoulder total arthroplasty and claviculo-pro-humero technique. Major complications included shoulder joint instability: modular prosthesis (26.2%), osteoarticular allograft (41.5%), allograft prosthesis composites (33.9%), reverse shoulder total arthroplasty (17%), composite reverse shoulder total arthroplasty (6.1%), claviculo-pro-humero technique (2.0%), and cement spacer (8.7%). Aseptic loosening of the prosthesis occurred: modular prosthesis (3.9%) and reverse shoulder total arthroplasty (5.7%). Allograft fracture was observed in 54.9% of patients with osteoarticular allograft. CONCLUSION: The complication profiles differed among reconstruction methods. Weighted mean MSTS scores exceeded 70% in all methods except cement spacer, and the 5-year reconstruction survival rate surpassed 80% for all methods except osteoarticular allograft. Proximal humerus reconstruction after bone tumor resection should consider potential complications and patients' individual factors.

3.
J Surg Oncol ; 129(3): 629-640, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37929793

RESUMO

BACKGROUND AND OBJECTIVE: The prognosis of metastatic renal cell carcinoma (RCC) has markedly improved with the advent of molecular targeted therapies and immune checkpoint inhibitors. However, the therapeutic response in patients with bone metastasis remains low; therefore, surgery still plays a significant role in treatment of bone metastasis. It is important to maintain quality of life for patients with bone metastasis from RCC and avoid reoperation after surgery for bone metastasis. Therefore, we investigated the risk factors for reoperation after surgery in patients with bone metastasis from RCC. METHODS: We retrospectively studied 103 bones of 97 patients who underwent surgery for bone metastasis of RCC from 2001 to 2023 at our institutions. RESULTS: Reoperation was performed in 10 (9.7%) of 103 bones. There was no correlation between reoperation-free survival and any of the following variables: preoperative and postoperative radiotherapy, site of bone metastasis, indication for surgery (solitary bone metastasis or impending or pathologic fractures), surgical method (intramedullary nailing fixation, curettage, or en bloc resection), preoperative embolization, or survival. CONCLUSION: The risk of reoperation for bone metastasis of RCC does not appear to be based on the surgical method.


Assuntos
Neoplasias Ósseas , Carcinoma de Células Renais , Neoplasias Renais , Humanos , Carcinoma de Células Renais/cirurgia , Reoperação , Neoplasias Renais/patologia , Resultado do Tratamento , Estudos Retrospectivos , Qualidade de Vida
4.
Children (Basel) ; 10(11)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-38002863

RESUMO

The objective of this study was to determine the efficacy of the PRECICE 2® nail in the treatment of lower limb length discrepancy in patients with a history of bone tumors. This study reports on outcomes, complications, and the safety of the PRECICE 2 limb lengthening nail in a cohort of pediatric patients with limb length discrepancy after surgery for bone tumors. Seventeen patients were treated with intramedullary magnetic nails. The average patient age at the time of surgery was 19 (range 11-32). The PRECICE 2 nail was used on 14 femurs (6 retrograde and 8 anterograde) and 3 tibias. The average consolidation time was 141 days (range 50-360) with a mean CI of 31 ± 12 days/cm. The ASAMI bone score showed 14 (82%) excellent results, 1 (6%) good result, and 2 (12%) poor results. The ASAMI functional score showed 13 (84.6%) excellent results, 3 (11.5%) good results, and 1 (3.8%) fair result. Patients treated with chemotherapy for bone cancer did not show any increase in distraction time or consolidation time. A total of 3 (17%) problems, 1 obstacle (5.5%), and 1 complication (5.5%) were encountered in our case series. The PRECICE 2 nail allows for effective and accurate lengthening preserving the range of motion in patients treated for bone tumors.

5.
Hip Int ; 31(2): 250-257, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31480877

RESUMO

INTRODUCTION: Articular surface replacement (ASR) XL implants exhibit higher-than-expected revision rates, blood ion concentrations and soft tissue lesions, making revisions troublesome and potentially unsatisfying. Appropriate techniques and outcomes in ASR XL revisions are rarely documented. The aims of this study were the assessments of pre-revision data, post-revision clinical and radiographic outcomes and ion levels in isolated acetabular ASR XL revisions performed using highly porous titanium cups and Delta ceramic articulations. METHODS: 18 isolated acetabular ASR XL revisions in 16 patients were performed using Ti-Por cups (Adler Ortho, Milan, Italy) and Delta bearings (CeramTec, Plochingen, Germany). Pre-revision demographic, clinical, radiological and implant-related features were assessed. Clinical and radiographic parameters (cup positioning, osseointegration) after revisions were evaluated at a minimum follow-up of 5 years. Ion concentrations in blood and urine were collected in pre-revision setting and 1 year after revision. RESULTS: 4 complications occurred in 3 different revisions (16.7%), 1 dislocation, 2 infections, 1 psoas impingement. No re-revision was performed at 5 years (1 scheduled arthroscopy). Good clinical outcomes were achieved (HHS score: 88.3 ± 9.2). All the cups showed reassuring signs of osseointegration (>3 parameters). Blood ion concentrations significantly decreased: patients with Co blood ion concentration over the threshold (7 µg/l) decreased from 76.5% to 0%. No pre-revision or intraoperative data influenced the revision outcomes. CONCLUSIONS: Highly porous titanium cups and Delta ceramic articulations provided reliable mid-term clinical and radiographic outcomes in isolated acetabular ASR XL revisions. Ion concentrations significantly decreased. Multicentre prospective controlled studies are required to confirm these preliminary outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Seguimentos , Alemanha , Humanos , Itália , Porosidade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação , Titânio
6.
Materials (Basel) ; 10(7)2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28773095

RESUMO

Recently, concerns have been raised about the potential effect of head-neck junction damage products at the local and systemic levels. Factors that may affect this damage process have not been fully established yet. This study investigated the possible correlations among head-neck junction damage level, implant design, material combination, and patient characteristics. Head-neck junctions of 148 retrieved implants were analysed, including both ceramic-on-ceramic (N = 61) and metal-on-metal (N = 87) bearings. In all cases, the male taper was made of titanium alloy. Damage was evaluated using a four-point scoring system based on damage morphology and extension. Patient age at implantation, implantation time, damage risk factor, and serum ion concentration were considered as independent potential predicting variables. The damage risk factor summarises head-neck design characteristics and junction loading condition. Junction damage correlated with both implantation time and damage factor risk when the head was made of ceramic. A poor correlation was found when the head was made of cobalt alloy. The fretting-corrosion phenomenon seemed mainly mechanically regulated, at least when cobalt alloy components were not involved. When a component was made of cobalt alloy, the role of chemical phenomena increased, likely becoming, over implantation time, the damage driving phenomena of highly stressed junctions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...