Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Biochem ; 41(6): 440-4, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18201564

RESUMO

OBJECTIVES: Development of a user-friendly test alternative to ELISA-based assays to detect IFN-gamma by in vitro cultured peripheral blood mononuclear cells (PBMC) stimulated with pathogen-derived antigens. DESIGN AND METHODS: The molecular components of an operational IFN-gamma ELISA-based test were applied in a lateral flow (LF) immuno-sandwich assay using up-converting phosphor (UCP) reporter particles. The analytical sensitivity of the UCP-LF IFN-gamma assay (ULIGA) was determined and the assay was qualitatively validated with a selection of 60 supernatants derived from PBMC cultures stimulated with M. leprae derived antigens, mitogen or medium alone. RESULTS: ULIGA indicated an analytical sensitivity better than 2 pg/mL, and demonstrated four orders of magnitude dynamic range. The assay correlated well with the IFN-gamma ELISA. CONCLUSIONS: ULIGA allows detection well below the cutoff value (100 pg/mL) used to define positive responses in the IFN-gamma ELISA. The test procedure is less demanding in respect to equipment and labor, and is suited for testing single samples.


Assuntos
Bioensaio/métodos , Interferon gama/metabolismo , Linfócitos T/metabolismo , Células Cultivadas , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Linfócitos T/citologia
2.
J Clin Microbiol ; 46(1): 171-6, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17942645

RESUMO

Schistosoma sp. circular anodic antigen (CAA) serum concentrations reflect actual worm burden in a patient and are a valuable tool for population screening and epidemiological research. However, for the diagnosis of individual imported schistosomiasis cases, the current enzyme-linked immunosorbent assay (ELISA) lacks sensitivity and robustness. Therefore, a lateral flow (LF) assay was developed to test CAA in serum for individual diagnosis of imported active schistosome infections. Application of fluorescent submicron-sized up-converting phosphor technology (UPT) reporter particles increased analytical sensitivity compared to that of the standard ELISA method. Evaluation of the UPT-LF test with a selection of 40 characterized epidemiologic samples indicated a good correlation between signal intensity and infection intensity. Subsequently, the UPT-LF assay was applied to 166 serum samples of Dutch residents (immigrants and travelers) suspected of schistosomiasis, a case in which group routine antibody detection frequently fails straightforward diagnosis. The UPT-LF assay identified 36 CAA-positive samples, compared to 15 detected by CAA-ELISA. In conclusion, the UPT-LF assay is a low-complexity test with higher sensitivity than the CAA-ELISA, well suited for laboratory diagnosis of individual active Schistosoma infections.


Assuntos
Antígenos de Helmintos/sangue , Parasitologia/métodos , Schistosoma/isolamento & purificação , Esquistossomose/diagnóstico , Animais , Humanos , Países Baixos , Schistosoma/química , Esquistossomose/imunologia , Sensibilidade e Especificidade , Soro/química
3.
Ann N Y Acad Sci ; 1098: 375-88, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17435143

RESUMO

Confirmatory detection of diseases, such as HIV and HIV-associated pathogens in a rapid point-of-care (POC) diagnostic remains a goal for disease control, prevention, and therapy. If a sample could be analyzed onsite with a verified result, the individual could be counseled immediately and appropriate therapy initiated. Our group is focused on developing a microfluidic "lab-on-a-chip" that will simultaneously identify antigens, antibodies, RNA, and DNA using a single oral sample. The approach has been to design individual modules for each assay that uses similar components (e.g., valves, heaters, metering chambers, mixers) installed on a polycarbonate base with a common reporter system. Assay miniaturization reduces the overall analysis time, increases accuracy by simultaneously identifying multiple targets, and enhances detector sensitivity by upconverting phosphor technology (UPT). Our microfluidic approach employs four interrelated components: (1) sample acquisition-OraSure UPlink collectors that pick-up and release bacteria, soluble analytes, and viruses from an oral sample; (2) microfluidic processing-movement of microliter volumes of analyte, target analyte extraction and amplification; (3) detection of analytes using UPT particles in a lateral flow system; and (4) software for processing the results. Ultimately, the oral-based microscale diagnostic system will detect viruses and bacteria, associated pathogen antigens and nucleic acids, and antibodies to these pathogens.


Assuntos
Medições Luminescentes/instrumentação , Microfluídica/instrumentação , Saliva/microbiologia , Saliva/virologia , Reações Antígeno-Anticorpo , Humanos , Medições Luminescentes/métodos , Microfluídica/métodos , Saliva/química , Saliva/imunologia
4.
Ann N Y Acad Sci ; 1098: 437-45, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17435148

RESUMO

A novel assay is described for multiplex detection of antibodies against different pathogens from a single sample. The assay employs a modified lateral flow format (consecutive flow, CF) together with a sensitive reporter particle technology (up-converting phosphor technology, UPT) that allows for fully instrumented assay analysis. Lateral flow (LF) strips developed for the detection of human antibodies against human immunodeficiency virus type-1 and -2 (HIV-1 and -2) with additional capture zones to detect antibodies against Myobacterium tuberculosis (TB) and hepatitis C Virus (HCV) provided the strips to test multiplexing. Data are presented that show the performance of the TB and HCV test, as well as two multiplex assays, TB with HIV and HCV with HIV. The TB/HCV assays demonstrate excellent detection capability, and HIV multiplexing does not affect the qualitative test result. The bench-top CF format was converted to a microfluidic platform and a first prototype semiautomated chip capable of performing CF is presented here.


Assuntos
Anticorpos Antibacterianos/sangue , Anticorpos Anti-HIV/sangue , HIV/imunologia , Hepacivirus/imunologia , Anticorpos Anti-Hepatite C/sangue , Mycobacterium tuberculosis/imunologia , Anticorpos Antibacterianos/biossíntese , Anticorpos Anti-HIV/biossíntese , Anticorpos Anti-Hepatite C/biossíntese , Humanos , Microfluídica/instrumentação
5.
Clin Biochem ; 36(5): 401-3, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12849874

RESUMO

OBJECTIVES: Development of a generally applicable sensitive hybridization-based assay devoid of any target amplification for the detection and identification of (pathogenic) bacterial and viral species. DESIGN AND METHODS: Using a sandwich hybridization format, the presence of a species-specific nucleic acid sequence is detected by means of Lateral Flow (LF) and Up-converting Phosphor Technology (UPT, a luminescent tracer). As a model, detection of the pathogen Streptococcus pneumoniae was investigated using a probe against the single-copy lytA gene. RESULTS: Detection of S. pneumoniae (in particular a 1200 p lytA sequences) required less than 1 ng of genomic DNA (approximate size 2.2 Mb). Hybridization and detection were performed in a complex background containing 10 microg fish sperm DNA. CONCLUSIONS: The results indicate the possibility to detect nucleic acid targets in nonamplified DNA samples using easy, inexpensive, amplification-free hybridization-based assays and the ultra sensitive UPT reporters. Employment of UPT allows to by-pass target amplification and therefore brings genetic-based testing a step closer to the point-of-care environment. Detection of S. pneumoniae with only 1 ng of DNA indicates a potential for applications in the field of infectious diseases.


Assuntos
DNA Bacteriano/análise , Hibridização de Ácido Nucleico/métodos , Streptococcus pneumoniae/genética , DNA Bacteriano/genética , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade
6.
Anal Biochem ; 312(2): 191-200, 2003 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-12531205

RESUMO

Up-converting Phosphor Technology (UPT) particles were used as reporters in lateral-flow (LF) assays to detect single-stranded nucleic acids. The 400-nm phosphor particles exhibit strong visible luminescence upon excitation with infrared (IR) light resulting in the total absence of background autofluorescence from other biological compounds. A sandwich-type hybridization assay was applied using two sequence-specific oligonucleotides. One of the oligonucleotides probes was covalently bound to the UPT particle (reporter) for direct labeling and detection, whereas the second oligonucleotide probe contained biotin for capture by avidin during LF. The whole procedure of hybridization, UPT-LF detection, and analysis required a minimum time of 20 min. Moreover, aiming at minimal equipment demands, the hybridization conditions were chosen such that the entire assay could be performed at ambient temperature. During lateral flow, only targets hybridized to both capture and detection oligonucleotide were trapped and detected at an avidin capture line on the LF strip. Analysis (IR scanning) of the strips was performed in an adapted microtiter plate reader provided with a 980-nm IR laser for excitation of the phosphor particles (a portable reader was also available). Visible luminescence was measured and presented as relative fluorescence units (RFU) allowing convenient quantitation of the phosphor signal. With the assay described here as little as 0.1 fmol of a specific single-stranded nucleic acid target was detected in a background of 10 microg fish sperm DNA.


Assuntos
DNA de Cadeia Simples/análise , Hibridização de Ácido Nucleico/métodos , Sondas de Oligonucleotídeos/análise , Animais , Sequência de Bases , DNA de Cadeia Simples/genética , Peixes/genética , Medições Luminescentes , Dados de Sequência Molecular , Sondas de Oligonucleotídeos/genética , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...