1.
Rev Sci Instrum ; 93(7): 074705, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35922304

RESUMO

Electrical Resistance Tomography (ERT) has the potentialities of non-intrusive techniques and high temporal resolution which are essential characteristics for multiphase flow measurements. However, high background conductivities, such as saline water in oil extraction, impose a limitation in ERT image reconstruction. Focusing on the operational limits of an ERT tomography system operating in different conductivity backgrounds from 0.010 to 4.584 S/m, the impact on the image reconstruction was assessed via signal-to-noise variance. The signal-to-noise ratio (SNR) variance had a strong correlation (p-value = 5.40 × 10-15) with the image reconstruction quality at the threshold of 30 dB, reaching a correlation value of r = -0.92 in the range of 0.010-0.246 S/m. Regarding the position error of the phantom, p-value = 1.30 × 10-5 and r = -0.66 were attained. The global results revealed that the correlation of the mean of the SNR (p-value = 5 × 10-4 and r = 0.55) was kept unaltered through the whole conductivity range, showing that such a statistical index can induce bias in establishing the operational limits of the hardware.


Assuntos
Tomografia Computadorizada por Raios X , Tomografia , Algoritmos , Impedância Elétrica , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Doses de Radiação , Razão Sinal-Ruído , Tomografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...