Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Geroscience ; 46(2): 2729-2738, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38157147

RESUMO

Several disturbances in T-cell mediated immunity have been described during aging, but immunosenescence of the B-cell compartment is less well elucidated. The peripheral blood B-cell compartment (CD19+) can be split into six main subpopulations according to the cell surface markers IgD, CD27, CD24, and CD38: Transitional, naïve, unswitched, switched, double negative and plasmablasts. We thus aimed to verify whether shifts in these subsets occur during healthy and pathological aging. We recruited three groups of aged people (> 60 years old), healthy, COPD patients, and smokers without altered pulmonary function test, and a fourth group of individuals 18-40 years old (youngs). Total B-cells percentage and absolute number were similar among the healthy aged, COPD patients, and youngs, but the smokers showed significantly higher absolute numbers. While all six B-cell subset percentages were comparable among the healthy aged, COPD patients, and youngs, smokers showed significantly higher percentages of switched B-cells and reduced naïve B-cells than the other three groups, resulting in an inverted naive:switched ratio. Analysis of the cell subset absolute numbers showed a similar trend. Overall, our results suggest that aging drives milder alterations in the distribution of peripheral blood B-cell subpopulations than in the T-cell compartment. We suggest that it is the T-cell immunosenescence that most contributes to the poor humoral immune responses in the elderly, vaccine responses included. Surprisingly it was the smokers who showed significant alterations when compared with the youngs, healthy aged, and aged COPD patients, probably as a result of the chronic immune stimulation described in active smoking subjects.


Assuntos
Subpopulações de Linfócitos B , Doença Pulmonar Obstrutiva Crônica , Idoso , Humanos , Linfócitos B , Envelhecimento , Subpopulações de Linfócitos B/química , Antígenos CD19/análise
3.
Immun Ageing ; 19(1): 9, 2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35164774

RESUMO

BACKGROUND: COPD is associated with an abnormal lung immune response that leads to tissue damage and remodeling of the lung, but also to systemic effects that compromise immune responses. Cigarette smoking also impacts on innate and adaptative immune responses, exerting dual, pro- and anti-inflammatory effects. Previously, we showed that COPD patients presented accelerated telomere shortening and decreased telomerase activity, while, paradoxically, cigarette-smokers exhibited preserved telomerase activity and slower rate of telomere shortening. RESULTS: Here, we evaluated the naive, CM, EM and TEMRA subsets of TCD4 and TCD8 cells according to the expression of CCR7/CD45RA. We compared age-matched COPD patients, cigarette-smokers without clinical-laboratory evidence of pulmonary compromise, and healthy individuals. They were additionally compared with a group of young adults. For each subset we analysed the expression of markers associated with late differentiation, senescence and exhaustion (CD27/CD28/CD57/KLRG1/PD1). We show that COPD patients presented a drastically reduced naive cells pool, and, paradoxically, increased fractions of naive cells expressing late differentiation, senescence or exhaustion markers, likely impacting on their immunocompetence. Pronounced phenotypic alterations were also evidenced in their three memory T-cell subsets compared with the other aged and young groups, suggesting an also dysfunctional memory pool. Surprisingly, our smokers showed a profile closer to the Healthy aged than COPD patients. They exhibited the usual age-associated shift of naive to EM TCD4 and TCD8 cells, but not to CM or TEMRA T-cells. Nonetheless, their naive T-cells phenotypes were in general similar to those of the Youngs and Healthy aged, suggesting a rather phenotypically preserved subset, while the memory T-cells exhibited increased proportions of cells with the late-differentiation or senescence/exhaustion markers as in the Healthy aged. CONCLUSION: Our study extends previous findings by showing that COPD patients have cells expressing a full range of late differentiated, senescent or exhausted phenotypes encompassing all TCD4 and TCD8 subsets, consistent with a premature immunosenescence phenotype. Surprisingly, the smokers group's results suggest that moderate to heavy chronic cigarette smoking did not accelerate the pace of immunosenescence as compared with the Healthy aged.

4.
Front Med (Lausanne) ; 8: 659416, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34395465

RESUMO

Background: The desaturation-distance ratio (DDR), the ratio of the desaturation area to the distance walked, is a promising, reliable, and simple physiologic tool for functional evaluation in subjects with interstitial lung diseases. Lymphangioleiomyomatosis (LAM) is a rare neoplastic condition frequently associated with exercise impairment. However, DDR has rarely been evaluated in patients with LAM. Objectives: To assess DDR during maximal and submaximal exercises and evaluate whether DDR can be predicted using lung function parameters. Methods: A cross-sectional study was conducted in a cohort of women with LAM. The 6-min walking test (6MWT) and the incremental shuttle walking test (ISWT) were performed, and DDR was obtained from both tests. The functional parameters were assessed at rest using spirometry and body plethysmography. The pulmonary function variables predictive of DDR were also assessed. Results: Forty patients were included in this study. The mean age was 46 ± 10 years. Airway obstruction, reduced DLCO, and air trapping were found in 60, 57, and 15% of patients, respectively. The distance walked and the DDR for the 6MWT and ISWT were, respectively, 517 ± 65 and 443 ± 127 m; and 6.6 (3.8-10.9) and 8.3 (6.2-12.7). FEV1 (airway obstruction) and reduced DLCO and RV/TLC (air trapping) were independent variables predictive of DDR during exercises field tests [DDR6MWT = 18.66-(0.06 × FEV1%pred)-(0.10 × DLCO%pred) + (1.54 × air trapping), R adjust 2 = 0.43] and maximal [DDRISWT = 18.84-(0.09 × FEV1%pred)-(0.05 × DLCO%pred) + (3.10 × air trapping), R adjust 2 = 0.33]. Conclusion: Our results demonstrated that DDR is a useful tool for functional evaluation during maximal and submaximal exercises in patients with LAM, and it can be predicted using airway obstruction, reduced DLCO, and air trapping.

5.
Mech Ageing Dev ; 197: 111501, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34000259

RESUMO

Immunosenescence are alterations on immune system that occurs throughout an individual life. The main characteristic of this process is replicative senescence, evaluated by telomere shortening. Several factors implicate on telomere shortening, such as smoking. In this study, we evaluated the influence of smoking and Chronic Obstructive Pulmonary Disease (COPD) on cytokines, telomere length and telomerase activity. Blood samples were collected from subjects aged over 60 years old: Healthy (never smokers), Smokers (smoking for over 30 years) and COPDs (ex-smokers for ≥15 years). A young group was included as control. PBMCs were cultured for assessment of telomerase activity using RT-PCR, and cytokines secretion flow cytometry. CD4+ and CD8+ purified lymphocytes were used to assess telomere length using FlowFISH. We observed that COPD patients have accelerated telomere shortening. Paradoxically, smokers without lung damage showed preserved telomere length, suggesting that tobacco smoking may affect regulatory mechanisms, such as telomerase. Telomerase activity showed diminished activity in COPDs, while Smokers showed increased activity compared to COPDs and Healthy groups. Extracellular environment reflected this unbalance, indicated by an anti-inflammatory profile in Smokers, while COPDs showed an inflammatory prone profile. Further studies focusing on telomeric maintenance may unveil mechanisms that are associated with cancer under long-term smoking.


Assuntos
Envelhecimento/imunologia , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/imunologia , Imunossenescência , Doença Pulmonar Obstrutiva Crônica/imunologia , Fumar/imunologia , Telomerase/imunologia , Encurtamento do Telômero/imunologia , Idoso , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Fumar/efeitos adversos
6.
J Appl Physiol (1985) ; 129(3): 492-499, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32702276

RESUMO

Subjects with severe and very severe chronic obstructive pulmonary disease (COPD) present thoracoabdominal asynchrony (TAA) that reduces ventilatory efficiency and exercise capacity. However, no therapeutic intervention has focused on reducing TAA. The purpose of this study was to evaluate the effects of elastic tape (ET) on thoracoabdominal mechanics, dyspnea symptoms, exercise capacity, and physical activity level in nonobese male subjects with severe-to-very severe COPD. This crossover, randomized trial included nonobese males with severe to very severe COPD. ET was placed on the chest wall and abdomen to reduce TAA. Subjects were evaluated at three hospital visits, each 7 days apart. At visit 1, thoracoabdominal kinematic and pulmonary ventilation were evaluated by optoelectronic plethysmography and electrical impedance tomography, respectively, both at rest and during isoload exercise testing. At visit 2, a cardiopulmonary exercise test (CPET; 10 W/min) was performed until exhaustion. Between the visits, subjects used a physical activity monitor (PAM) (at least 5 days of measurement; 10 h/day). At visit 3, all the tests were repeated in the opposite order of the previous randomization. During the isoload exercise, subjects with ET presented lower tidal and minute volumes (P = 0.01) and reduced TAA (P = 0.02) and dyspnea (P = 0.04). During the CPET, subjects with ET presented an increase in peak oxygen consumption (V̇o2peak; L/min and mL·kg-1·min-1; P = 0.01), test duration (P = 0.009), and maximal load (P = 0.03). Moderate and vigorous physical activity (MVPA), which was evaluated by the PAM, was also increased in subjects with ET (P = 0.01). ET reduced TAA and dyspnea and increased exercise capacity and the duration of MVPA in nonobese male subjects with severe-to-very severe COPDNEW & NOTEWORTHY Elastic tape can be used as a new and low-cost intervention to reduce thoracoabdominal asynchrony and sedentary behavior as well as improve exercise capacity and physical activity level in nonobese male subjects with severe-to-very severe chronic obstructive pulmonary disease.


Assuntos
Tolerância ao Exercício , Doença Pulmonar Obstrutiva Crônica , Estudos Cross-Over , Dispneia , Exercício Físico , Teste de Esforço , Humanos , Masculino
7.
J Cardiopulm Rehabil Prev ; 39(6): 391-396, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31689266

RESUMO

PURPOSE: This study evaluated the accuracy of the Mini-Balance Evaluation System Test (Mini-BESTest) for predicting falls in patients with chronic obstructive pulmonary disease (COPD) and investigated whether postural balance is a risk factor for falls. METHODS: Postural balance was evaluated by the Mini-BESTest at baseline, and the incidence of falls over a 12-mo period was prospectively measured by a self-reported falls diary and confirmed by telephone calls. A discriminative power analysis was performed using receiver operating characteristic (ROC) curve and logistic regression analysis. RESULTS: Sixty-seven outpatients with COPD (mean age ± SD = 67 ± 9.3 yr) were included. Twenty-five patients (37.3%) experienced ≥1 fall, and 28.2% of the falls resulted in injuries. The Mini-BESTest predicted falls in patients with COPD at the 6- and 12-mo follow-ups with a cut-off score of 22.5 (area under the curve = 0.85 and 0.87) with good sensitivity and specificity (85.7% and 66.7%; 84% and 73.8%, respectively). Higher scores on the Mini-BESTest were associated with a lower risk of falls at 12 mo (OR = 0.50; 95% CI, 0.36-0.70; P < .001). CONCLUSIONS: Postural balance assessed by the Mini-BESTest is a good predictor of falls in patients with COPD. Our results imply that impaired balance contributes to the risk of falling and that balance training and fall prevention programs may be required for this population.


Assuntos
Acidentes por Quedas/estatística & dados numéricos , Pacientes Ambulatoriais/estatística & dados numéricos , Equilíbrio Postural/fisiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Idoso , Brasil , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Psicometria , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Lung ; 196(3): 271-276, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29525851

RESUMO

Exercise training has been shown to reduce symptoms and exacerbations in COPD patients; however, the exercise effect on patients' immune response is poorly known. We thus verified if an exercise program (EP) impacted on proliferative T cell response of COPD patients. Fourteen non-O2 dependent COPD patients on standard treatment were studied. EP consisted in 24 sessions of aerobic and muscular training. Peripheral blood mononuclear cells were stimulated with the mitogen phytohemagglutinin and antigens from Haemophilus influenzae and cytomegalovirus, and the lymphocyte proliferative response (LPR) was assessed through the expression of Ki67 before and after the EP. The Quality of life [COPD assessment test (CAT)], dyspnea [(modified Medical Research Council scale (mMRC)], and 6-min walk distance were also assessed. The EP program increased significantly the LPR of TCD4+ lymphocytes to phytohemagglutinin and cytomegalovirus and H. influenzae antigens, but with TCD8+ lymphocytes the increase was less marked. Consistent with this, a higher proportion of TCD8+ than TCD4+ cells did not express the costimulatory molecule CD28. The EP also resulted in improvement of the quality of life, dyspnea, and physical capacity. The improvement in TCD4+ cell function may represent an additional mechanism through which the EP results in less exacerbations and hospitalizations.


Assuntos
Proliferação de Células/fisiologia , Terapia por Exercício , Linfócitos/imunologia , Doença Pulmonar Obstrutiva Crônica/reabilitação , Linfócitos T/imunologia , Idoso , Antígenos de Bactérias/imunologia , Antígenos de Bactérias/farmacologia , Antígenos Virais/imunologia , Antígenos Virais/farmacologia , Linfócitos T CD4-Positivos/efeitos dos fármacos , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/efeitos dos fármacos , Linfócitos T CD8-Positivos/imunologia , Proliferação de Células/efeitos dos fármacos , Citomegalovirus/imunologia , Dispneia , Feminino , Volume Expiratório Forçado , Haemophilus influenzae/imunologia , Humanos , Antígeno Ki-67/efeitos dos fármacos , Antígeno Ki-67/metabolismo , Masculino , Pessoa de Meia-Idade , Fito-Hemaglutininas/imunologia , Fito-Hemaglutininas/farmacologia , Doença Pulmonar Obstrutiva Crônica/imunologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Qualidade de Vida , Linfócitos T/efeitos dos fármacos , Capacidade Vital , Teste de Caminhada
9.
PLoS One ; 12(8): e0182417, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28767680

RESUMO

BACKGROUND: Thoracoabdominal asynchrony is the nonparallel motion of the ribcage and abdomen. It is estimated by using respiratory inductive plethysmography and, recently, using optoelectronic plethysmography; however the agreement of measurements between these 2 techniques is unknown. Therefore, the present study compared respiratory inductive plethysmography with optoelectronic plethysmography for measuring thoracoabdominal asynchrony to see if the measurements were similar or different. METHODS: 27 individuals (9 healthy subjects, 9 patients with interstitial lung disease, and 9 with chronic obstructive pulmonary disease performed 2 cycle ergometer tests with respiratory inductive plethysmography or optoelectronic plethysmography in a random order. Thoracoabdominal asynchrony was evaluated at rest, and at 50% and 75% of maximal workload between the superior ribcage and abdomen using a phase angle. RESULTS: Thoracoabdominal asynchrony values were very similar in both approaches not only at rest but also with exercise, with no statistical difference. There was a good correlation between the methods and the Phase angle values were within the limits of agreement in the Bland-Altman analysis. CONCLUSION: Thoracoabdominal asynchrony measured by optoelectronic plethysmography and respiratory inductive plethysmography results in similar values and has a satisfactory agreement at rest and even for different exercise intensities in these groups.


Assuntos
Abdome/fisiopatologia , Doenças Pulmonares Intersticiais/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Tórax/fisiopatologia , Adulto , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Pletismografia , Mecânica Respiratória
10.
Dent Traumatol ; 33(5): 350-357, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28453886

RESUMO

BACKGROUND: Intra-oral photographs have been aided diagnosis of several pathologies in teledentistry. Mobile phone cameras may produce high-quality photographs, presenting itself as a viable tool for remote diagnosis of traumatic dental injuries. AIM: To evaluate the levels of interexaminer agreement in cases of traumatic dental injuries when comparing diagnoses conducted in person and remotely. MATERIAL AND METHODS: The sample included 40 patients with 73 traumatized teeth, and a total of 90 diagnoses, who had presented to two dental clinics, one private, and the other public, in Brazil's Federal District. The dental history and clinical examination data were registered in electronic forms, and digital photographs were captured with a mobile phone camera and uploaded to a cloud drive. Six remote examiners formulated their diagnoses based solely on photographic analysis. Thereafter, they were provided with additional clinical data and asked to provide a second round of diagnoses. These diagnoses were compared to those conducted in person, which were considered the gold standard. The data were analyzed with Gwet's AC1 interexaminers' measure to evaluate the agreement between the in-surgery and remote diagnoses. RESULTS: The levels of interexaminer agreement between the in-surgery and remote diagnoses formulated exclusively with images were 0.83 or higher (95% confidence interval: 0.73-0.91), and 0.93 or higher (95% confidence interval: 0.88-0.97), when clinical information was available. CONCLUSION: The precision of the remote diagnoses was comparable to the diagnoses conducted in person. The levels of interexaminer agreement were higher when clinical data were included with the images. Mobile phones may be an effective tool for capturing images that assist in the remote diagnosis of traumatic dental injuries.


Assuntos
Telefone Celular , Fotografia Dentária , Traumatismos Dentários/diagnóstico por imagem , Adolescente , Adulto , Brasil , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Lactente , Masculino
11.
J Appl Physiol (1985) ; 122(5): 1106-1113, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28183817

RESUMO

Determining the presence of thoracoabdominal asynchrony in chronic obstructive pulmonary disease (COPD) patients is clinically relevant, but there is no consensus on the optimal parameters for performing this analysis. We assessed 22 COPD patients (FEV1 40 ± 10% predicted) and 13 healthy controls during rest and exercise with optoelectronic plethysmography (70% maximum workload) on a cycle ergometer. Thoracoabdominal asynchrony was calculated by using phase angle and phase shift parameters following a three-compartment model involving the upper and lower rib cages and abdomen. Patients were classified as having thoracoabdominal asynchrony (TAA+) or not (TAA-) based on control values (mean ± 2 SDs). The chest wall volume and compartmental contribution were also measured. Thoracoabdominal asynchrony was observed in the lower rib cage. The phase angle detected more TAA+ patients at rest (15 vs. 7 patients) and during exercise (14 vs. 8 patients) compared with the phase shift. TAA+ patients also presented a lower chest wall volume, lower rib cage contribution, and higher abdominal contribution to chest wall volume compared with the control and TAA- patients. Thoracoabdominal asynchrony was more detectable during rest and exercise using the phase angle parameter, and it was observed in the lower rib cage compartment, reducing the chest wall volume during exercise in patients with COPD.NEW & NOTEWORTHY This study contributes to advance the knowledge over the previous lack of consensus on the assessment of thoracoabdominal asynchrony. We rigorously evaluated the related features that interfere in the measurement of the asynchrony (measurement tool, chest wall model and calculation parameter). Our results suggest that phase angle detects more suitably thoracoabdominal asynchrony that occurs on the lower ribcage and leads to a reduction in the chest wall volume during exercise in COPD patients.


Assuntos
Abdome/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Mecânica Respiratória/fisiologia , Estudos Transversais , Exercício Físico/fisiologia , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pletismografia/métodos , Descanso/fisiologia , Parede Torácica/fisiopatologia
12.
Eur Respir J ; 47(5): 1452-60, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26917604

RESUMO

Lymphangioleiomyomatosis (LAM) is a cystic lung disease frequently associated with reduced exercise capacity. The aim of this study was to assess safety and efficacy of pulmonary rehabilitation in LAM.This controlled clinical trial included 40 patients with LAM and a low physical activity level. The pulmonary rehabilitation programme comprised 24 aerobic and muscle strength training sessions and education. The primary outcome was exercise capacity (endurance time during a constant work rate exercise test). Secondary outcomes included health-related quality of life (St George's Respiratory Questionnaire (SGRQ)), 6-min walking distance (6MWD), dyspnoea, peak oxygen consumption (V'O2 ), daily physical activity (pedometer), symptoms of anxiety and depression, lung function and peripheral muscle strength (one-repetition maximum).The baseline characteristics were well balanced between the groups. The pulmonary rehabilitation group exhibited improvements in the following outcomes versus controls: endurance time (median (interquartile range) 169 (2-303) s versus -33 (-129-39) s; p=0.001), SGRQ (median (interquartile range) -8 (-16-2) versus 2 (-4-5); p=0.002) and 6MWD (median (interquartile range) 59 (13-81) m versus 20 (-12-30) m; p=0.002). Dyspnoea, peak V'O2 , daily physical activity and muscle strength also improved significantly. No serious adverse events were observed.Pulmonary rehabilitation is a safe intervention and improves exercise capacity, dyspnoea, daily physical activity, quality of life and muscle strength in LAM.


Assuntos
Terapia por Exercício , Linfangioleiomiomatose/fisiopatologia , Linfangioleiomiomatose/reabilitação , Adulto , Ansiedade/diagnóstico , Brasil , Depressão/complicações , Depressão/diagnóstico , Dispneia/complicações , Dispneia/diagnóstico , Exercício Físico , Teste de Esforço , Feminino , Humanos , Linfangioleiomiomatose/psicologia , Pessoa de Meia-Idade , Consumo de Oxigênio , Segurança do Paciente , Qualidade de Vida , Inquéritos e Questionários , Resultado do Tratamento , Caminhada
13.
Respir Physiol Neurobiol ; 210: 1-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25620656

RESUMO

OBJECTIVE: To investigate the relationship between the presence of symptoms of anxiety or depression with breathing pattern and thoracoabdominal mechanics at rest and during exercise in COPD. METHODS: Cross-sectional study enrolled 54 patients with COPD ranked according to Hospital Anxiety and Depression Scale (HAD) score and compared to dyspnea, clinical control, hypercapnia, breathing pattern and thoracoabdominal mechanics at rest and during exercise. RESULTS: Seventeen patients with COPD had no symptoms, 12 had anxiety symptoms, 13 had depressive symptoms and 12 had both symptoms. COPD with depressive symptoms presented greater degree of dyspnea (p<0.01). Poor clinical control was observed in COPD with anxious and/or depressive symptoms (p<0.05). Breathing pattern and thoracoabdominal mechanics were similar among all groups at rest and during exercise. CONCLUSIONS: COPD with symptoms of depression report more dyspnea. Anxiety and depression are associated with poor clinical control without impact on breathing pattern and thoracoabdominal mechanics in COPD.


Assuntos
Músculos Abdominais/fisiopatologia , Ansiedade , Depressão , Dispneia/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Músculos Respiratórios/fisiopatologia , Idoso , Ansiedade/fisiopatologia , Fenômenos Biomecânicos , Gasometria , Estudos Transversais , Depressão/fisiopatologia , Dispneia/psicologia , Exercício Físico/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Escalas de Graduação Psiquiátrica , Doença Pulmonar Obstrutiva Crônica/psicologia , Doença Pulmonar Obstrutiva Crônica/terapia , Respiração , Descanso/fisiologia , Índice de Gravidade de Doença
14.
Respir Care ; 59(3): 420-6, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23983269

RESUMO

BACKGROUND: Aging causes physiological and functional changes that impair pulmonary function. Incentive spirometry is widely used for lung expansion, but the effects of volume-oriented incentive spirometry (VIS) versus flow-oriented incentive spirometry (FIS) on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly are poorly understood. We compared VIS and FIS in elderly subjects and healthy adult subjects. METHODS: Sixteen elderly subjects (9 women, mean ± SD age 70.6 ± 3.9 y, mean ± SD body mass index 23.8 ± 2.5 kg/m(2)) and 16 healthy adults (8 women, mean ± age 25.9 ± 4.3 y, mean ± body mass index 23.6 ± 2.4 kg/m(2)) performed quiet breathing, VIS, and FIS in randomized sequence. Chest wall kinematics (via optoelectronic plethysmography) and inspiratory muscle activity (via surface electromyography) were assessed simultaneously. Synchrony between the superior thorax and abdominal motion was calculated (phase angle). RESULTS: In the elderly subjects both types of incentive spirometry increased chest wall volumes similarly, whereas in the healthy adult subjects VIS increased the chest wall volume more than did FIS. FIS and VIS triggered similar lower thoracoabdominal synchrony in the elderly subjects, whereas in the healthy adults FIS induced lower synchrony than did VIS. FIS required more muscle activity in the elderly subjects to create an increase in chest wall volume. CONCLUSIONS: Incentive spirometry performance is influenced by age, and the differences between elderly and healthy adults response should be considered in clinical practice.


Assuntos
Exercícios Respiratórios , Mecânica Respiratória/fisiologia , Músculos Respiratórios/fisiologia , Espirometria/métodos , Adulto , Idoso , Eletromiografia , Feminino , Humanos , Masculino , Parede Torácica , Adulto Jovem
15.
Artif Organs ; 37(11): 946-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24237361

RESUMO

An implantable centrifugal blood pump (ICBP) is being developed to be used as a ventricular assist device (VAD) in patients with severe cardiovascular diseases. The ICBP system is composed of a centrifugal pump, a motor, a controller, and a power supply. The electricity source provides power to the controller and to a motor that moves the pump's rotor through magnetic coupling. The centrifugal pump is composed of four parts: external conical house, external base, impeller, and impeller base. The rotor is supported by a pivot bearing system, and its impeller base is responsible for sheltering four permanent magnets. A hybrid cardiovascular simulator (HCS) was used to evaluate the ICBP's performance. A heart failure (HF) (when the heart increases beat frequency to compensate for decrease in blood flow) was simulated in the HCS. The main objective of this work is to analyze changes in physiological parameters such as cardiac output, blood pressure, and heart rate in three situations: healthy heart, HF, and HF with left circulatory assistance by ICBP. The results showed that parameters such as aortic pressure and cardiac output affected by the HF situation returned to normal values when the ICBP was connected to the HCS. In conclusion, the test results showed satisfactory performance for the ICBP as a VAD.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Coração/fisiologia , Coração/fisiopatologia , Circulação Assistida , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Modelos Cardiovasculares , Desenho de Prótese
16.
Artif Organs ; 37(11): 942-5, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24219168

RESUMO

A new model of centrifugal blood pump for temporary ventricular assist devices has been developed and evaluated. The design of the device is based on centrifugal pumping principles and the usage of ceramic bearings, resulting in a pump with reduced priming (35 ± 2 mL) that can be applied for up to 30 days. Computational fluid dynamic (CFD) analysis is an efficient tool to optimize flow path geometry, maximize hydraulic performance, and minimize shear stress, consequently decreasing hemolysis. Initial studies were conducted by analyzing flow behavior with different impellers, aiming to determine the best impeller design. After CFD studies, rapid prototyping technology was used for production of pump prototypes with three different impellers. In vitro experiments were performed with those prototypes, using a mock loop system composed of Tygon tubes, oxygenator, digital flow meter, pressure monitor, electronic driver, and adjustable clamp for flow control, filled with a solution (1/3 water, 1/3 glycerin, 1/3 alcohol) simulating blood viscosity and density. Flow-versus-pressure curves were obtained for rotational speeds of 1000, 1500, 2000, 2500, and 3000 rpm. As the next step, the CFD analysis and hydrodynamic performance results will be compared with the results of flow visualization studies and hemolysis tests.


Assuntos
Coração Auxiliar , Centrifugação , Cerâmica/química , Coração Auxiliar/efeitos adversos , Hemólise , Humanos , Hidrodinâmica , Desenho de Prótese
17.
Artif Organs ; 37(11): 954-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24251773

RESUMO

The Spiral Pump (SP), a centrifugal blood pump for cardiopulmonary bypass (CPB), has been developed at the Dante Pazzanese Institute of Cardiology/Adib Jatene Foundation laboratories, with support from Sintegra Company (Pompeia, Brazil). The SP is a disposable pump with an internal rotor-a conically shaped fuse with double entrance threads. This rotor is supported by two ball bearings, attached to a stainless steel shaft fixed to the housing base. Worm gears provide axial motion to the blood column, and the rotational motion of the conically shaped impeller generates a centrifugal pumping effect, improving pump efficiency without increasing hemolysis. In vitro tests were performed to evaluate the SP's hydrodynamic performance, and in vivo experiments were performed to evaluate hemodynamic impact during usual CPB. A commercially available centrifugal blood pump was used as reference. In vivo experiments were conducted in six male pigs weighing between 60 and 90 kg, placed on CPB for 6 h each. Blood samples were collected just before CPB (T0) and after every hour of CPB (T1-T6) for hemolysis determination and laboratory tests (hematological and biochemical). Values of blood pressure, mean flow, pump rotational speed, and corporeal temperature were recorded. Also, ergonomic conditions were recorded: presence of noise, difficulty in removing air bubbles, trouble in installing the pump in the drive module (console), and difficulties in mounting the CPB circuit. Comparing the laboratory and hemolysis results for the SP with those of the reference pump, we can conclude that there is no significant difference between the two devices. In addition, reports made by medical staff and perfusionists described a close similarity between the two devices. During in vivo experiments, the SP maintained blood flow and pressure at physiological levels, consistent with those applied in cardiac surgery with CPB, without presenting any malfunction. Also, the SP needed lower rotational speed to obtain average blood flow and pressure, compared with the reference pump.


Assuntos
Circulação Assistida/instrumentação , Ponte Cardiopulmonar/instrumentação , Animais , Circulação Assistida/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Desenho de Equipamento , Hemólise , Hidrodinâmica , Masculino , Suínos
18.
Respir Care ; 58(8): 1360-6, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23258579

RESUMO

BACKGROUND: Incentive spirometers are widely used in clinical practice and classified as flow-oriented (FIS) and volume-oriented (VIS). Until recently the respiratory inductive plethysmography used to evaluate the effects of incentive spirometry on chest wall mechanics presented limitations, which may explain why the impact of VIS and FIS remains poorly known. OBJECTIVE: To compare the effects of VIS and FIS on thoracoabdominal mechanics and respiratory muscle activity in healthy volunteers. METHODS: This cross-sectional trial assessed 20 subjects (12 female, ages 20-40 years, body mass index 20-30 kg/m(2)). All subjects performed 8 quiet breaths and 8 deep breaths with FIS and VIS, in a randomized order. We measured thoracoabdominal chest wall, upper and lower rib-cage, and abdominal volumes with optoelectronic plethysmography, and the muscle activity of the sternocleidomastoid and superior and inferior intercostal muscles with electromyography. RESULTS: VIS increased chest wall volume more than did FIS (P = .007) and induced a larger increase in the upper and lower rib-cages and abdomen (156%, 91%, and 151%, respectively, P < .001). By contrast, FIS induced more activity in the accessory muscles of respiration than did VIS (P < .001). CONCLUSIONS: VIS promotes a greater increase in chest wall volume, with a larger abdominal contribution and lower respiratory muscle activity, than does FIS in healthy adults.


Assuntos
Pletismografia , Mecânica Respiratória/fisiologia , Músculos Respiratórios/fisiologia , Espirometria/métodos , Parede Torácica/fisiologia , Músculos Abdominais/fisiologia , Adulto , Estudos Transversais , Eletromiografia , Feminino , Humanos , Masculino , Adulto Jovem
19.
Artif Organs ; 35(5): 437-42, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21595708

RESUMO

An implantable centrifugal blood pump has been developed with original features for a left ventricular assist device. This pump is part of a multicenter and international study with the objective to offer simple, affordable, and reliable devices to developing countries. Previous computational fluid dynamics investigations and wear evaluation in bearing system were performed followed by prototyping and in vitro tests. In addition, previous blood tests for assessment of normalized index of hemolysis show results of 0.0054±2.46 × 10⁻³ mg/100 L. An electromechanical actuator was tested in order to define the best motor topology and controller configuration. Three different topologies of brushless direct current motor (BLDCM) were analyzed. An electronic driver was tested in different situations, and the BLDCM had its mechanical properties tested in a dynamometer. Prior to evaluation of performance during in vivo animal studies, anatomical studies were necessary to achieve the best configuration and cannulation for left ventricular assistance. The results were considered satisfactory, and the next step is to test the performance of the device in vivo.


Assuntos
Coração Auxiliar , Hemodinâmica , Implantação de Prótese , Função Ventricular Esquerda , Animais , Fenômenos Biomecânicos , Brasil , Bovinos , Masculino , Teste de Materiais , Desenho de Prótese
20.
Artif Organs ; 35(5): 443-7, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21595709

RESUMO

A new model of blood pump for cardiopulmonary bypass (CPB) application has been developed and evaluated in our laboratories. Inside the pump housing is a spiral impeller that is conically shaped and has threads on its surface. Worm gears provide an axial motion of the blood column. Rotational motion of the conical shape generates a centrifugal pumping effect and improves pumping performance. One annular magnet with six poles is inside the impeller, providing magnetic coupling to a brushless direct current motor. In order to study the pumping performance, a mock loop system was assembled. Mock loop was composed of Tygon tubes (Saint-Gobain Corporation, Courbevoie, France), oxygenator, digital flowmeter, pressure monitor, electronic driver, and adjustable clamp for flow control. Experiments were performed on six prototypes with small differences in their design. Each prototype was tested and flow and pressure data were obtained for rotational speed of 1000, 1500, 2000, 2500, and 3000 rpm. Hemolysis was studied using pumps with different internal gap sizes (1.35, 1.45, 1.55, and 1.7 mm). Hemolysis tests simulated CPB application with flow rate of 5 L/min against total pressure head of 350 mm Hg. The results from six prototypes were satisfactory, compared to the results from the literature. However, prototype #6 showed the best results. Best hemolysis results were observed with a gap of 1.45 mm, and showed a normalized index of hemolysis of 0.013 g/100 L. When combined, axial and centrifugal pumping principles produce better hydrodynamic performance without increasing hemolysis.


Assuntos
Ponte Cardiopulmonar/instrumentação , Coração Auxiliar , Hemólise , Animais , Velocidade do Fluxo Sanguíneo , Ponte Cardiopulmonar/efeitos adversos , Bovinos , Coração Auxiliar/efeitos adversos , Hemorreologia , Hidrodinâmica , Magnetismo , Teste de Materiais , Pressão , Desenho de Prótese , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...