Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vaccines (Basel) ; 10(4)2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35455340

RESUMO

The COVID-19 pandemic has led the world to undertake the largest vaccination campaign in human history. In record time, unprecedented scientific and governmental efforts have resulted in the acquisition of immunizers utilizing different technologies (nucleotide acids, viral vectors, inactivated and protein-based vaccines). Currently, 33 vaccines have already been approved by regulatory agencies in different countries, and more than 10 billion doses have been administered worldwide. Despite the undeniable impact of vaccination on the control of the pandemic, the recurrent emergence of new variants of interest has raised new challenges. The recent viral mutations precede new outbreaks that rapidly spread at global proportions. In addition, reducing protective efficacy rates have been observed among the main authorized vaccines. Besides these issues, several other crucial issues for the appropriate combatting of the pandemic remain uncertain or under investigation. Particularly noteworthy issues include the use of vaccine-boosting strategies to increase protection; concerns related to the long-term safety of vaccines, child immunization reliability and uncommon adverse events; the persistence of the virus in society; and the transition from a pandemic to an endemic state. In this review, we describe the updated scenario regarding SARS-CoV-2 variants and COVID-19 vaccines. In addition, we outline current discussions covering COVID-19 vaccine safety and efficacy, and the future pandemic perspectives.

2.
PLoS One ; 16(6): e0250854, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34086691

RESUMO

The use of personal protective equipment (PPE) has been considered the most effective way to avoid the contamination of healthcare workers by different microorganisms, including SARS-CoV-2. A spray disinfection technology (chamber) was developed, and its efficacy in instant decontamination of previously contaminated surfaces was evaluated in two exposure times. Seven test microorganisms were prepared and inoculated on the surface of seven types of PPE (respirator mask, face shield, shoe, glove, cap, safety glasses and lab coat). The tests were performed on previously contaminated PPE using a manikin with a motion device for exposure to the chamber with biocidal agent (sodium hypochlorite) for 10 and 30s. In 96.93% of the experimental conditions analyzed, the percentage reduction was >99% (the number of viable cells found on the surface ranged from 4.3x106 to <10 CFU/mL). The samples of E. faecalis collected from the glove showed the lowest percentages reduction, with 86.000 and 86.500% for exposure times of 10 and 30 s, respectively. The log10 reduction values varied between 0.85 log10 (E. faecalis at 30 s in glove surface) and 9.69 log10 (E. coli at 10 and 30 s in lab coat surface). In general, E. coli, S. aureus, C. freundii, P. mirabilis, C. albicans and C. parapsilosis showed susceptibility to the biocidal agent under the tested conditions, with >99% reduction after 10 and 30s, while E. faecalis and P. aeruginosa showed a lower susceptibility. The 30s exposure time was more effective for the inactivation of the tested microorganisms. The results show that the spray disinfection technology has the potential for instant decontamination of PPE, which can contribute to an additional barrier for infection control of healthcare workers in the hospital environment.


Assuntos
COVID-19/prevenção & controle , Descontaminação , Controle de Infecções , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Roupa de Proteção , Dispositivos de Proteção Respiratória , SARS-CoV-2 , Bactérias , Infecções Bacterianas/epidemiologia , Infecções Bacterianas/prevenção & controle , Infecções Bacterianas/transmissão , COVID-19/epidemiologia , COVID-19/transmissão , Descontaminação/instrumentação , Descontaminação/métodos , Humanos
3.
PLoS One ; 16(5): e0251817, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34010343

RESUMO

The transmission of SARS-CoV-2 through contact with contaminated surfaces or objects is an important form of transmissibility. Thus, in this study, we evaluated the performance of a disinfection chamber designed for instantaneous dispersion of the biocidal agent solution, in order to characterize a new device that can be used to protect individuals by reducing the transmissibility of the disease through contaminated surfaces. We proposed the necessary adjustments in the configuration to improve the dispersion on surfaces and the effectiveness of the developed equipment. Computational Fluid Dynamics (CFD) simulations of the present technology with a chamber having six nebulizer nozzles were performed and validated through qualitative and quantitative comparisons, and experimental tests were conducted using the method Water-Sensitive Paper (WSP), with an exposure to the biocidal agent for 10 and 30 s. After evaluation, a new passage procedure for the chamber with six nozzles and a new configuration of the disinfection chamber were proposed. In the chamber with six nozzles, a deficiency was identified in its central region, where the suspended droplet concentration was close to zero. However, with the new passage procedure, there was a significant increase in wettability of the surface. With the proposition of the chamber with 12 nozzles, the suspended droplet concentration in different regions increased, with an average increase of 266%. The experimental results of the new configuration proved that there was an increase in wettability at all times of exposure, and it was more significant for an exposure of 30 s. Additionally, even in different passage procedures, there were no significant differences in the results for an exposure of 10 s, thereby showing the effectiveness of the new configuration or improved spraying and wettability by the biocidal agent, as well as in minimizing the impact caused by human factor in the performance of the disinfection technology.


Assuntos
COVID-19/epidemiologia , Descontaminação/métodos , Desinfecção/métodos , SARS-CoV-2/efeitos dos fármacos , COVID-19/metabolismo , COVID-19/transmissão , COVID-19/virologia , Descontaminação/instrumentação , Desinfetantes/análise , Desinfecção/instrumentação , Humanos , Hidrodinâmica , Modelos Teóricos , Pandemias , SARS-CoV-2/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...