Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Lasers Med Sci ; 38(1): 261, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37947919

RESUMO

COVID-19 Related Long-Term Taste Impairment (CRLTTI) is a condition that can be expressed after COVID-19 contagion, lasting for months or even years, affecting the routine and quality of life of individuals. Participants expressing CRLTTI, with a minimum of 2 months, attested by PCR-RT test were assessed for taste and smell, and underwent experimental treatments in 6 distinct groups: Photobiomodulation (PBM) in tongue dorsum and lateral (660 nm, 808 nm, association of 660 and 808 nm), Transmucosal Laser Irradiation of Blood (TLIB)-ventral surface of tongue (660 nm), B complex supplementation, and Sham laser. No intergroup statistical differences were observed at the final evaluation, despite the tendencies of better results with PBM and TLIB observed. PBM, TLIB, and B complex might be treatment options in the management of CRLTTI, despite the lack of total remission of taste and smell perception after 8 sessions (PBM and TLIB) or 30 days of B complex supplementation.


Assuntos
COVID-19 , Terapia com Luz de Baixa Intensidade , Humanos , COVID-19/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Qualidade de Vida , Paladar , Método Duplo-Cego
3.
Photodiagnosis Photodyn Ther ; 42: 103245, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36640856

RESUMO

PURPOSE: There has been growing demand for dental bleaching worldwide, however, despite being effective, hydrogen peroxide (HP) can negatively affect the dental structure. Thus, new techniques, such as violet LED light have emerged and need to be studied. The aim of this study was to analyze and compare the effectiveness of violet LED light alone or combined with 35% HP gel. METHODS: Six different tooth bleaching techniques (n = 10) were performed in intrinsically pigmented bovine teeth: G1 - 35% HP (1x/week for 4 weeks, 45 min of gel application); G2 - 35% HP (1x/week for 4 weeks, 15 min of gel application); G3 - violet LED (1x/week for 4 weeks); G4 - violet LED (2x/week for 2 weeks); G5 - violet LED (4x/week for 1 week); G6 - Violet LED + 35% HP (hybrid technique, 1x/week for 4 weeks, 15 min of gel application). Specimens were submitted to color evaluation at predetermined times using Konica Minolta® spectrophotometer, and the surface morphology (n = 3) was qualitatively analyzed by Scanning Electron Microscope (SEM). Data of the color change test were analyzed considering a 5% level of significance. RESULTS: There was significant difference in color (p <0.05) for all groups after bleaching protocols. SEM analysis revealed that the greatest change in surface occurred in Group G1, with demineralization of the dental enamel. When considering the same time interval, there were no statistical differences for axis L*, but differences were shown for axis a* (G2, G3, G4 ≥ G1, G5 ≥ G6) and b* (G1, G2, G3, G4, G5 > G6). Regarding the comparison of ΔE00 between groups, results showed statistical difference between groups, with G1 ≥ G2, G5, G6 ≥ G3, G4. CONCLUSION: Bleaching protocols with less time (15 min) or no exposure to 35% HP (violet LED, 4x/week) could promote bleaching results as those obtained by the conventional technique using 35% HP for 45 min, with no enamel surface changes, showing to be a promising alternative to tooth bleaching.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Peróxido de Hidrogênio , Clareamento Dental/métodos , Clareadores Dentários/farmacologia , Ácido Hipocloroso
4.
Photodiagnosis Photodyn Ther ; 38: 102739, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35123016

RESUMO

This clinical study evaluated the effect of bleaching performed with violet LED light (405-410 nm), either combined with hydrogen peroxide (HP) gel, or not, on color change, dental sensitivity, participants' satisfaction and impact on their quality of life. A hundred participants were divided into one of the groups (n = 25): G1 - 35% HP (4 sessions, 1x/week); G2 - violet LED (4 sessions, 1x/week); G3 - violet LED (4 sessions, 2x/week); G4 - hybrid technique (violet LED + 35% HP; 4 sessions, 1x/week). Color evaluation was performed with colorimetric tests (objective and subjective), before, 14 days and 3 months after completion. Additionally, satisfaction with treatment, impact on quality of life (OHIP-14) and dental sensitivity were recorded. The data were submitted to statistical analysis, considering a significance level of 5%, with the exception of the data from the questionnaire on satisfaction (descriptive analysis). Two-way ANOVA and Tukey tests showed that there was no difference between color variation resulting from techniques used in G1 and G4; those used in G2 and G3 did not differ and were less effective for bleaching than those of the other groups, in both subjective and objective evaluations. Regarding tooth sensitivity, subjects in G2 and G3 experienced no sensitivity, ​​while those in G4 showed lower sensitivity values than those in G1. With respect to quality of life, only subjects in G1 and G2 showed a significant positive impact. Among the evaluated techniques, the hybrid type seemed to be a good alternative, showing effective bleaching with less tooth sensitivity.


Assuntos
Sensibilidade da Dentina , Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Método Duplo-Cego , Humanos , Peróxido de Hidrogênio/uso terapêutico , Fotoquimioterapia/métodos , Qualidade de Vida , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico
5.
Photobiomodul Photomed Laser Surg ; 39(12): 774-781, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34878933

RESUMO

Objective: This randomized clinical trial evaluated the sensitive return of the lower alveolar nerve (LAN) using two photobiomodulation therapy (PBMT) techniques, after the extraction of lower third molars or implant surgery. Materials and methods: Sixty participants with sensory impairment of LAN were randomly divided into three groups (n = 20): group C-systemic medication (control-ETNA®, 01 capsule, 8/8 h, 30 days); group laser therapy (LT) (808 nm, 100 mW, 40 sec/point, 4 J/point, intra/extraoral, irradiation following nerve path); group laser acupuncture (LA) (same parameters as the LT group, applied at six acupuncture points on the affected side (ST 4 [Dicang], M-HN-18 [Jiachengjiang], CV 24 [Chengjiang], ST 5 [Daying], ST 6 [Jiache], and point A1 [YNSA]). The following evaluations were performed, at predetermined times: general perception of paresthesia, thermal perception, vibratory mechanical perception, two-point discrimination, pain perception, and tactile perception. Data were analyzed by two-way analysis of variance (ANOVA), followed by the Tukey, except for the two-point discrimination, which was analyzed using the chi-square test. Results: In general and thermal perception, both PBMTs had better results than control; regarding cold perception, only the LT group was statistically superior to control. LA presented inferior results of neural regeneration for tests of perception of pain and tactile at the lip, and of tactile perception at the chin. In the other tests, there was no statistical difference among the groups. Conclusions: LT and the conventional drug treatment had the same effectiveness and both were superior to LA for the treatment of paresthesia of the LAN after oral surgeries.


Assuntos
Terapia por Acupuntura , Terapia a Laser , Terapia com Luz de Baixa Intensidade , Humanos , Dente Serotino/cirurgia , Parestesia/etiologia , Parestesia/terapia
6.
Caries Res ; 55(6): 617-628, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34689142

RESUMO

OBJECTIVES: This single-blind, controlled crossover in situ study aimed to evaluate the effect of CO2 laser (9.3 µm) irradiation combined with AmF/NaF/SnCl2 solution on prevention and control of erosive tooth wear (ETW) in human enamel. MATERIALS AND METHODS: Two trial conditions were analyzed, condition 1 as ETW prevention (sound tooth surface) and condition 2 as ETW control (in vitro initial erosive lesion). The experiment was conducted in 2 phases, one with and one without exposure to AmF/NaF/SnCl2 solution. Hundred and ninety-two samples of human enamel (3 × 3 × 1 mm) were randomly divided into 4 experimental groups for each condition: C, without treatment (negative control); F, AmF/NaF/SnCl2 solution (positive control); L, CO2 laser irradiation; and L + F, CO2 laser + AmF/NaF/SnCl2 solution. Twelve volunteers used a removable device, each containing 8 samples per phase. Ex vivo erosive challenges (4 × 5 min/day) and rinsing protocol (1 × 30 s/day) were performed. The surface loss was determined using optical profilometer (n = 12 per group), and the surface morphology was observed with scanning electron microscopy (n = 3). RESULTS: In condition 1, data were analyzed by one-way ANOVA and condition 2 by two-way repeated-measures ANOVA, both with Tukey post hoc tests (α = 5%). In condition 1, groups L (4.59 ± 2.95 µm) and L + F (1.58 ± 1.24 µm) showed significantly less surface loss in preventing ETW than groups C and F. In condition 2, in controlling the progression of ETW, L + F was the only group with no significant surface loss between initial erosive lesion (3.65 ± 0.16 µm) and after erosive challenge (4.99 ± 1.17 µm). CONCLUSIONS: CO2 9.3-µm laser application prevented and controlled ETW progression in human enamel, with greater efficiency when combined with AmF/NaF/SnCl2 solution application.


Assuntos
Lasers de Gás , Erosão Dentária , Desgaste dos Dentes , Esmalte Dentário , Humanos , Lasers de Gás/uso terapêutico , Método Simples-Cego , Fluoreto de Sódio/uso terapêutico , Erosão Dentária/etiologia , Erosão Dentária/prevenção & controle
7.
Photodiagnosis Photodyn Ther ; 36: 102497, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34428577

RESUMO

A new LED wavelength, violet LED (VL) with a wavelength between 405 - 410 nm was recently introduced to be used for in-office dental bleaching. In comparison to the blue LED system (440 to 485 nm), the shorter wavelength has more energy carried in its photons and also corresponds to the absorption peak of the stained particles, which lead to whitening utilizing a physical process. Considering the need to suggest and develop new protocols with this new technology, this article reports 2 different dental bleaching protocols developed in a split-mouth model using VL. A 25-year-old male patient was submitted to in-office dental bleaching. On the teeth from the left side, the bleaching gel (35% H2O2) was renewed 3 times (every 8 mins), and on the right side, the gel was maintained without renewal during the bleaching session. The irradiation with Violet LED Light (405 nm ± 10 nm) was performed with the following protocol: 1 min of irradiation with 30 s light off until 8 min of total time. A total of 3 cycles were performed (total time of 24 min). Two bleaching sessions were performed with an interval of 7 days between sessions. Based on the results of this split-mouth case report, there was no visible difference in the final color outcome and sensitivity between both bleaching protocols tested.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Adulto , Humanos , Peróxido de Hidrogênio , Masculino , Boca , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes
8.
Photodiagnosis Photodyn Ther ; 36: 102509, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34455106

RESUMO

BACKGROUND: To clinically evaluate the effect of 35% hydrogen peroxide gel renewal in association with violet LED (405-410nm) through a split-mouth randomized controlled clinical trial. METHODS: The treatment consisted in 3 bleaching sessions of 15 min each, with an interval of 7 days between them, using 35% hydrogen peroxide combined to violet LED irradiation. Selected patients had two experimental segments for the split-mouth design: No change of the bleaching gel during each session (NBGR) and 3 changes of the bleaching gel every 5 min for each session (BGR). During the 3 bleaching sessions, the selected quadrant received the same treatment. Patients had their upper canines and central incisors teeth color measured with a subjective (color scale - VITA Classical) and an objective (spectrophotometer - VITA Easyshade) method and their teeth sensitivity measured using a Visual Analog Scale (VAS) before, immediately after each bleaching session, and 14 days and 2 months (60 days) after the end of the treatment. RESULTS: The protocol adopted in the present study reached satisfactory results regarding color change. No statistical difference between groups was observed immediately after the end of the treatment and in the follow-up analysis for both subjective and objective color evaluation. No difference in tooth sensitivity between segments was observed. CONCLUSION: There is no need for bleaching gel renewal when following the clinical protocol of 3 sessions of 15 min in a bleaching protocol of 35% hydrogen peroxide combined with violet LED.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Cor , Humanos , Peróxido de Hidrogênio , Boca , Fotodegradação , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Resultado do Tratamento
9.
Lasers Med Sci ; 36(2): 311-315, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32372235

RESUMO

Biosafety materials used in the correct handling of low power laser equipment may interfere on the power delivered at the target tissue and, possibly, on the effects on biological tissues. The aim of this study was to evaluate the interference of the use of polyvinyl chloride (PVC) and polyethylene (PEAD) protection materials on the output power of low power lasers. Two low power diode laser devices with different wavelengths (red and infrared) were used. For each wavelength, two protection materials and two evaluation times (before and after protection) were considered. The output power (mW) was measured with the tip positioned in close contact with the power meter receiver. Parametric statistical test, two-way ANOVA for repeated measures (protection material and time), was performed considering the level of significance of 5%. In respect to "time", all groups had the output power reduced after placing the protective material (p < 0.05). Comparing the protection materials, the PEAD showed a greater reduction in output power than the PVC for both red and infrared wavelengths. It was concluded that, among the biosafety materials tested, PVC is the most suitable for the protection of the tip of the low power lasers.


Assuntos
Contenção de Riscos Biológicos , Lasers , Humanos , Raios Infravermelhos , Polietileno/química , Cloreto de Polivinila/química
10.
Lasers Med Sci ; 36(7): 1487-1495, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33216247

RESUMO

To evaluate the effect of Er:YAG laser conditioning of a glass-infiltrated alumina-based zirconia-reinforced ceramic on its flexural strength and on bonding to a resin cement. Sixteen blocks (5 × 5 × 4 mm) and 50 discs (Ø 12 mm, 1 mm thickness) of In-Ceram Zirconia (ICZ) obtained from CAD-CAM blocks were infiltrated with glass. For the microtensile bond strength (µTBS) test, all blocks were treated with aluminum oxide (AOX) and divided into 4 groups (n = 4): G1 (AOX), no combined surface treatment; G2 (ROC), tribochemical silica-coating; G3 (EY200), Er:YAG laser 200 mJ/15 Hz; and G4 (EY250), Er:YAG laser 250 mJ/10 Hz. The ceramic blocks were silanated and cemented with a resin cement (Panavia F2.0/Kuraray) to composite resin blocks and subjected to the µTBS test. For the flexural strength evaluation, the discs were divided into 5 groups (n = 10) as described above, in addition to a control group (G5 - CTRL, mirror-polished without further treatment). Each surface treatment was submitted to qualitative evaluation under SEM. One-way ANOVA (α = 5%) revealed the highest bond strength value for EY200 with no significant difference from ROC. The groups AOX and EY250 showed similar µTBS values that were statistically lower than those of EY200. For flexural strength, ROC was the only group with significantly lower values when compared with the CTRL. The use of Er:YAG laser at 200 mJ/15 Hz can be considered an innovative and effective alternative for surface conditioning of ICZ since it did not reduce the flexural strength of the ceramic and improved the resin cement bond to this substrate.


Assuntos
Colagem Dentária , Lasers de Estado Sólido , Cerâmica , Lasers de Estado Sólido/uso terapêutico , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Zircônio
11.
Gen Dent ; 67(3): 67-70, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31199748

RESUMO

In-office dental bleaching allows the dentist to have greater control of the procedure and prevents patients from ingesting chemicals. To obtain optimum results, in-office bleaching usually requires a longer period of application as well as changes of the bleaching agent applied to the tooth surfaces at each appointment. The objective of this case report was to assess, by means of a split-mouth design in a single patient, the final tooth color and tooth sensitivity resulting from 2 different bleaching protocols: 1 application of 35% hydrogen peroxide for 45 minutes and 3 applications of 35% hydrogen peroxide for 15 minutes each. Neither the patient nor 5 individuals who were blinded to the techniques noted a difference in the final esthetic results of the 2 protocols immediately after the procedure. In addition, the patient reported that no tooth sensitivity was associated with either protocol. The results of dental bleaching on both sides were maintained after 15 days. The results shown in the present case report suggest that there may be no need to renew the gel during in-office dental bleaching.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Sensibilidade da Dentina/etiologia , Sensibilidade da Dentina/prevenção & controle , Estética Dentária , Humanos , Peróxido de Hidrogênio/administração & dosagem , Peróxido de Hidrogênio/efeitos adversos , Clareamento Dental/métodos , Clareadores Dentários/administração & dosagem , Clareadores Dentários/efeitos adversos
12.
Photobiomodul Photomed Laser Surg ; 37(4): 262-266, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31050957

RESUMO

Objective: The aim of this article was to describe and discuss a clinical case in which the Nd:YAG laser and a desensitizing agent were associated in a protocol for dentin hypersensitivity (DH) in teeth with molar-incisor hypomineralization (MIH). Background data: DH is a common condition among the population, being one of the main reasons for patients to seek for a dental treatment. MIH can be considered a condition that induces DH. Methods: The patient was referred for evaluation, complaining of hypersensitivity during eating or drinking cold foods. Clinical evaluation revealed the presence of MIH on the first lower molars. Aiming to treat DH, two strategies for dentin desensitization were associated: the use of a high-power laser (Nd:YAG laser, 1.064 nm; Lares Research), with a 300 µm quartz optical fiber, 1 W of power, 100 mJ of energy, 10 Hz of repetition rate, and 85 J/cm2 of energy density, followed by the application of two layers of a desensitizing agent (Gluma Desensitizer). Results: DH was evaluated immediately, after 1 week and after 1 month of the treatment. Clinical outcomes were satisfactory, confirming the efficacy and considerable durability of the protocol used for the reduction of DH originated from MIH. Conclusions: The association of Nd:YAG laser and a desensitizing agent for controlling DH was effective, showing to be an interesting protocol.


Assuntos
Hipoplasia do Esmalte Dentário/complicações , Dessensibilizantes Dentinários/farmacologia , Sensibilidade da Dentina/terapia , Lasers de Estado Sólido/uso terapêutico , Criança , Humanos , Masculino , Medição da Dor
13.
Photobiomodul Photomed Laser Surg ; 37(4): 240-243, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31050958

RESUMO

Background: Radiotherapy is one of the treatments for cancer, which leads to many oral side effects that affect the quality of life of the patient; among them, trismus is considered. Objective: Considering the various therapies to treat this collateral effect of radiotherapy, photobiomodulation (PBM) with low-level laser is a contemporary alternative. Methods: In this article, an all-clinical case report is presented in which the patient was given trismus after radiotherapy and PBM with low-level laser. The measurement of the buccal opening was evaluated in each treatment session with a digital caliper, and the pain was evaluated through the visual analog scale (VAS). Results: The efficacy of the PBM protocol on the trismus after radiotherapy was evidenced by the decrease of pain and increase of the buccal opening. Conclusions: The use of PBM with low-level laser is an option for the treatment of trimus after radiotherapy.


Assuntos
Terapia com Luz de Baixa Intensidade/métodos , Neoplasias Orofaríngeas/radioterapia , Trismo/radioterapia , Idoso , Humanos , Masculino , Neoplasias Orofaríngeas/cirurgia , Medição da Dor , Trismo/etiologia
14.
Lasers Med Sci ; 34(7): 1391-1399, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30762196

RESUMO

The purpose of this study was to explore the influence of Er:YAG laser irradiation with different pulse durations on the organic matrix, micromorphology of the hybrid layer (HL), and bond strength over time. Sixty caries-free human molars were cut to obtain flat dentin surfaces which were randomly divided into 4 groups: control (not irradiated-G1) and laser groups (80 mJ/2 Hz) with pulse duration ranging between 50 (G2), 300 (G3), and 600 µs (G4). A self-etch adhesive system (Universal 3M ESPE) was applied on pre-treated dentin surfaces and cylinders of resin composite were built up and stressed in a universal testing machine (µSBS) at 24 h and after12 months (n = 12). In addition, 3 other dentin-bonded specimens were prepared as previously described for each group with the adhesive doped with 0.1 wt% Rhodamine B to analyze hybrid layer morphology under Confocal Laser Microscope Scanning (CLMS). Organic matrix and collagen fibrils were analyzed by second harmonic generation (SGH). Two-way ANOVA and Tukey's test detected significantly higher µSBS values for the control group, whereas the lower values were observed in all laser groups at 24 h (p < 0.05). Storage in artificial saliva did not reduce µSBS in all groups. The low signal emitted by SHG images below the irradiated area demonstrated thermal damage of the collagen matrix. CLMS images of laser groups exhibited thicker and irregular resin-dentin interfaces than the control group. Regardless of the pulse duration, Er:YAG laser pre-treatment altered the organic matrix and HL formation which resulted in low µSBS values at 24 h. The alterations on dentin's organic structure did not jeopardize the µSBS after 1 year of saliva storage.


Assuntos
Dentina/efeitos da radiação , Lasers de Estado Sólido , Resinas Sintéticas/efeitos da radiação , Colagem Dentária , Adesivos Dentinários/efeitos da radiação , Humanos , Resistência à Tração
15.
Photomed Laser Surg ; 36(7): 391-394, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29920150

RESUMO

BACKGROUND: Several photobiomodulation (PBM) protocols with low-power lasers have been reported for pain control and tissue repair in the postoperative period of oral surgeries. However, there are still no reports of a protocol for bichectomy surgeries' postoperative period. OBJECTIVE: This article presents six reports of clinical cases in which bichectomy surgery was performed. METHODS: In the postoperative period, three patients were submitted to PBM with low-power lasers, while three patients did not receive it. Facial edema was evaluated using a millimeter tape. Pain was determined using the visual analog scale. RESULTS: Data of each clinical case were evaluated in a descriptive way and compared. CONCLUSIONS: The efficacy of the PBM protocol on the postoperative period of bichectomy surgeries was evidenced by the decrease of edema and pain.


Assuntos
Bochecha/cirurgia , Procedimentos Cirúrgicos Dermatológicos/efeitos adversos , Edema/prevenção & controle , Terapia com Luz de Baixa Intensidade , Dor Pós-Operatória/prevenção & controle , Adulto , Edema/etiologia , Feminino , Humanos , Masculino , Dor Pós-Operatória/etiologia
16.
Lasers Med Sci ; 33(4): 745-753, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29204915

RESUMO

The present study aims to evaluate the current scientific data regarding the effectiveness of photobiomodulation (PBM) in the treatment of dentin hypersensitivity (DH) as an alternative method for pain control. A systematic review was conducted to assess the effectiveness of PBM as treatment for DH. A complete literature search was performed up to October 2016. Searches were conducted using Boolean operators and MeSH terms. References of all selected full-text articles and related reviews were scanned. A total of 280 articles were identified (241 articles were excluded by the title and abstract). Of the 39 articles selected for analysis, 36 were excluded because they presented one or more exclusion criteria. Therefore, three articles were qualified for inclusion in this systematic review. PBM may not lead to adverse effects provided that adequately controlled parameters are followed when treating DH. More consistent studies should be conducted in order to adequately observe the advantageous therapeutic effect of PBM.


Assuntos
Sensibilidade da Dentina/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Feminino , Humanos , Masculino , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Photodiagnosis Photodyn Ther ; 20: 273-275, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29107824

RESUMO

Chronic gingivostomatitis in dogs is an inflammatory syndrome of the oral cavity, which treatment and control of concomitant periodontitis allow healing in most of the cases. In the presence of recurrent lesions, invasive methods are necessary to treat lesions and pain. As a conservative adjuvant method, photobiomodulation (PBM) with low power laser is able to promote reduction of tissue pain and tissue inflammation besides increasing vascularization and healing, restoring the normal function of the irradiated organ in a shorter time. In veterinary medicine, there is no standardization of technique for its use in oral tissue for treating gingivostomatitis in dogs. In the present case, a dog was submitted to aPDT (7.2J/point, 3min/point, 180J/cm2) and PBM (1.6J/point, 40s/point, 25J/cm2), using a semiconductor diode laser, with wavelength of 660nm, spot size of ​​0.04cm2 and output power of 40mW. The established protocol proved to be effective as coadjutant treatment for chronic gingivostomatitis, restoring the integrity of dog's affected mucosa and gingiva.


Assuntos
Lasers Semicondutores/uso terapêutico , Terapia com Luz de Baixa Intensidade/métodos , Azul de Metileno/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Estomatite/radioterapia , Animais , Pré-Escolar , Terapia Combinada , Cães , Gengiva , Humanos , Terapia com Luz de Baixa Intensidade/veterinária , Fotoquimioterapia/métodos , Estomatite/veterinária
18.
Med Acupunct ; 29(5): 290-299, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29067139

RESUMO

Objective: The goal of this research was to observe the influence of electroacupuncture (EA) and laser-acupuncture on the return of tactile/pain sensitivity in patients who underwent orthognathic surgery. Materials and Methods: Thirty volunteers subjected to orthognathic surgery were evaluated and randomly divided into 2 groups, in which 3 treatments were evaluated: control (n = 30) (G0, medication + placebo laser treatment) and 2 experimental treatments (n = 15) (G1, medication + EA) or G2 (medication + laser-acupuncture). The control group had n = 30 because for each experimental treatment conducted on a volunteer's hemi-face, there was a control treatment on the other hemi-face. In G1, medication was given with EA, with needles placed at predetermined points (ST 4 [Dicang], M-HN-18 [Jiachengjiang], CV 24 [Chengjiang], ST 5 [Daying], ST 6 [Jiache], and point A1 [YNSA]). For electrostimulation, the device used delivered transcutaneous electrical nerve stimulation of a burst type, with intensity and frequency variations of T = 220 ms and F = 4 Hz (30 minutes, 2 × /week). In G2, in addition to the medication, laser irradiation (at 780 nm) was applied on acupuncture points (at 0.04 cm2, 70 mW, 6 s/point, 0.42 J/point, 10 J/cm2, 2 × /week). All volunteers were evaluated before and during the 4 months following the surgery. Tactile sensitivity was assessed by mechanical brushing (brush #s 2 and 12) and by a 2-point discrimination test, using a bow compass. A pain test was performed with a pulp electrical test that stimulates intact nerves of the dentin-pulp complex. A Kaplan-Meier test was performed, and survival curves were plotted for comparison between groups. Cox regression analysis was also conducted (α = 0.05). Results: There were no statistically significant differences among the groups for the 2-point discrimination test (brushes #2 and #12) on the buccal mucosa region and for the pulp test on all evaluated regions. However, the tactile test using brush #12 revealed significant differences between G1 and the other groups when considering the lower lip (P = 0.024) and chin (P = 0.028) areas. Conclusions: Only EA was able to influence-using the brushing test (brush #12)-the return of tactile sensitivity on the chin and lower lip positively after combined orthognathic surgery and genioplasty.

19.
Oral Health Prev Dent ; 15(4): 365-370, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28831459

RESUMO

PURPOSE: To evaluate whether increasing the frequency of its use can enhance the protective effect of AmF/NaF/SnCl2 solution against dental erosion. MATERIALS AND METHODS: Sixty human enamel samples were obtained from sound human third molars, and after the formation of incipient erosive lesions (1% citric acid, pH 4.0, for 3 min), they were divided into five treatment groups (n = 12): G1 - deionised water (negative control); G2 - NaF solution (positive control) once a day; G3 - NaF solution (positive control) twice a day; G4 - AmF/NaF/SnCl2 solution once a day; G5 - AmF/NaF/SnCl2 solution twice a day. The samples were then subjected to 5 days of erosive cycling through 6 daily immersions (2 min each) in citric acid solution (0.05 M, pH 2.6). At the end of erosive cycling, surface wear was determined by means of optical profilometry. RESULTS: One-way ANOVA showed that the surface wear was affected by surface treatments (p < 0.001). Tukey's test showed no difference between the groups in which NaF was applied once or twice, but they showed limited reduction in wear compared to the deionised water group (G1). In the groups treated with the AmF/NaF/SnCl2 solution, there was a statistically significant difference between one and two application times (p < 0.001). Although both demonstrated statistically significantly reduced tissue loss, increasing the frequency increased its anti-erosive potential. CONCLUSION: The AmF/NaF/SnCl2 solution proved to be effective in reducing dental enamel surface loss and its use twice a day potentiated its anti-erosive effect.


Assuntos
Cariostáticos/administração & dosagem , Esmalte Dentário/efeitos dos fármacos , Fluoretos Tópicos/administração & dosagem , Fluoreto de Sódio/administração & dosagem , Compostos de Estanho/administração & dosagem , Erosão Dentária/prevenção & controle , Progressão da Doença , Combinação de Medicamentos , Humanos , Técnicas In Vitro , Soluções
20.
Gen Dent ; 65(4): e8-e11, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28682288

RESUMO

Postoperative sensitivity is one of the most common side effects of in-office bleaching with hydrogen peroxide. Laser phototherapy (LPT) has been suggested as an adjunctive treatment to prevent or minimize tooth sensitivity. This case report aimed to verify the efficacy of LPT in the reduction of sensitivity after in-office bleaching. Tooth bleaching was performed with 35% hydrogen peroxide activated with a hybrid LED-laser device. Immediately after the bleaching treatment, the patient reported dental sensitivity, as measured with a visual analog scale (VAS). To reduce sensitivity, LPT was applied with a 780-nm laser using the following parameters: 70 mW, exposure time of 10 seconds per point of irradiation (middle region of the buccal surfaces of each compromised tooth) in contact mode, energy of 1 J per point. Immediately after LPT, the patient reported a substantially lower level of pain on the VAS. Twenty-four hours after bleaching, the score on the VAS indicated that sensitivity levels had rebounded, and the patient received additional LPT. After 48 hours, the patient reported no dental sensitivity. The results in this patient indicated that irradiation with an infrared low-power laser substantially reduced dental pain generated by bleaching, suggesting that LPT should be considered as an auxiliary method to reduce postbleaching tooth sensitivity.


Assuntos
Sensibilidade da Dentina/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Clareamento Dental/efeitos adversos , Adulto , Sensibilidade da Dentina/etiologia , Humanos , Masculino , Medição da Dor
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...