Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. bras. med. trab ; 16(4): 524-531, dez-2018.
Artigo em Inglês, Português | LILACS | ID: biblio-980493

RESUMO

Introdução: Lombalgia é um problema internacional importante de saúde pública. O uso de cinta lombar no meio ocupacional emerge da expectativa de inúmeros benefícios biomecânicos que, em conjunto, promoveriam a prevenção desse problema. Objetivo: Orientar estudantes, médicos e estabelecimentos de saúde sobre o uso de cinta lombar, suporte ou órtese lombar como prevenção da lombalgia ou de lesões lombares em trabalhadores sem sintomatologia atual. Método: Ela foi desenvolvida a partir da revisão sistemática da literatura: da base de dados MEDLINE, foram recuperados 809 trabalhos e das bases EMBASE e Central Cochrane, 571. Avaliar a cinta lombar como intervenção preventiva de lombalgia envolve a quantificação de benefícios, malefícios e facilidade de sua implementação, assim como a qualidade metodológica dos estudos primários. Conclusão: Apesar do benefício demonstrado fracamente em resultados individuais, parciais e isolados em poucos estudos, não há evidência consistente que sustente a utilização de cinta lombar, suporte ou órtese lombar na prevenção primária da lombalgia ou de lesões lombares ocupacionais em trabalhadores. As evidências, agrupadas, apontam para ausência de redução de absenteísmo com o uso da cinta lombar.


Background: Low back pain is a considerable global public health problem. Use of back belts in occupational settings arises from the expectation of countless biomechanical benefits, which together would contribute to the prevention of this problem. Objective: To orient students, physicians and health institutions on the use of back belts, lumbar support or braces for prevention of low back pain or injury among asymptomatic workers. Method: The present guideline was developed based on a systematic literature review; 809 studies were located in database MEDLINE and 571 in EMBASE and Cochrane CENTRAL. Evaluating back-belt use as preventive intervention against low back pain demands quantifying benefits, harms and difficulties to implementation, as well as the methodological quality of primary studies. Conclusion: Despite the weak benefits reflected in the individual, partial and isolated results of a few studies, there is no consistent evidence for the use of back belts, lumbar supports or braces for primary prevention of low back pain or occupational low back injury among workers. According to the available evidence, back-belt use is not associated with reduction of absenteeism


Assuntos
Aparelhos Ortopédicos/normas , Dor Lombar/prevenção & controle , Doenças Profissionais , Absenteísmo , Instalações de Saúde/normas
2.
Rev Bras Ortop ; 49(6): 593-601, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26229867

RESUMO

OBJECTIVES: To evaluate the concordance among knee surgery specialists regarding the classification and surgical technique indicated in cases of tibial plateau fracture, using conventional radiographs and computed tomography. METHODS: Forty-four patients with fractures of the tibial plateau shown on radiographic and tomographic images were selected. These were evaluated by specialists at two different times, with an interval of seven days. On the first occasion, the specialists only had access to the radiographs, while on the second occasion they had access to both radiographs and computed tomography images. Their concordance was evaluated by means of the kappa coefficient. RESULTS: The interobserver reliability of the Schatzker classification on the first occasion was 0.36 and on the second occasion, 0.35. This was considered to present low reproducibility. In evaluating the intra-observer reproducibility of this classification, the mean kappa index was 0.42, which was classified as moderate. From evaluating the choice of surgical access, the inter-observer reliability was 0.55 on the first occasion and 0.50 on the second, which was considered to present moderate reproducibility. Evaluation on the implant chosen showed that the interobserver reliability was 0.01 on the first occasion and -0.06 on the second, which was considered to be poor and discordant. In evaluating the classification of the three columns, the inter-observer reproducibility was 0.47 (p < 0.0001), which was classified as moderate concordance. CONCLUSION: Use of computed tomography did not present any improvement in the inter-observer concordance, using the Schatzker classification, and did not produce any change in the preoperative planning.


OBJETIVOS: Avaliar a concordância entre especialistas em cirurgia de joelho com relação à classificação e à técnica cirúrgica indicada nas fraturas do platô tibial com o uso das radiografias convencionais e da tomografia computadorizada. MÉTODOS: Foram selecionados 44 pacientes com fraturas de platô tibial com suas imagens radiográficas e tomográficas, as quais foram avaliadas por especialistas em dois momentos distintos, com intervalo de sete dias. No primeiro momento os especialistas tiveram acesso apenas às radiografias e no segundo às radiografias e às imagens de tomografia computadorizada. A concordância foi avaliada por meio do coeficiente kappa. RESULTADOS: A confiabilidade interobservador para a classificação de Schatzker no primeiro momento foi 0,36 e no segundo 0,35, consideradas de baixa reprodutibilidade. Na avaliação da reprodutibilidade intraobservador dessa classificação, a média do índice κ foi de 0,42, classificada como moderada. A avaliação da escolha do acesso cirúrgico teve uma confiabilidade interobservador de 0,55 num primeiro momento e 0,50 no segundo, consideradas de reprodutibilidade moderada. Quando avaliado o implante escolhido, a confiabilidade interobservador foi de 0,01 no primeiro momento e -0,06 no segundo, consideradas ruim e discordante. Na avaliação da classificação das três colunas, a reprodutibilidade interobservador foi de 0,47 (p < 0,0001), classificada como concordância moderada. CONCLUSÃO: O uso da tomografia computadorizada não apresentou melhoria na concordância interobservador na classificação de Schatzker, bem como não promoveu mudança no planejamento pré-operatório.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...