Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pract Lab Med ; 26: e00246, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34337126

RESUMO

BACKGROUND: Therapeutic drug monitoring (TDM) of gentamicin sulfate (GEN) is usually recommended, particularly in critical patients. Only a few reports had described the determination of GEN in plasma or plasma using LC-MS/MS. OBJECTIVE: This study aimed to develop and validate a sensitive ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) assay for the quantification of GEN in small volumes of human plasma. RESULTS: The use of a very low concentration of the ion-pairing agent HFBA allowed significant retention of the very polar GEN forms in a reversed phase UHPLC column. The solid-phase extraction (SPE) procedure allowed clean extracts, with no interferences detected in blank samples, and high sensitivity. The assay was linear on the range of 0.2-40 mg L-1 of GEN complex. The combined GEN complex had inter-assay CV of 8.8-10.0%, intra-assay CV of 10.2-11.0%, and accuracy of 96.8-104.0%. The assay was applied to 17 clinical samples obtained from neonate patients. Measured concentrations were in the range of 0.15-3.57 mg L-1 for GEN C1, 0.12-3.55 mg L-1 for GEN C1a, 0.20-5.77 mg L-1 for GEN C2, and 0.47-12.88 mg L-1 for the GEN complex, all within the linear range of the assay. CONCLUSION: A sensitive assay for the quantification of gentamicin in plasma using anion-exchange SPE and UHPLC-MS/MS was validated. The assay can be used for TDM of gentamicin, particularly in centers with access to proper instrumentation and with a low demand for gentamicin measurements, where immunoassays are not cost-effective.

2.
Artigo em Inglês | MEDLINE | ID: mdl-33621796

RESUMO

Valproic acid (VA) is a drug widely used on the treatment of epilepsy and bipolar affective disorders, with stablished therapeutic concentration ranges in serum. The measurement of VA serum concentrations using chromatographic methods requires a sample preparation step. In this context, this study aims to describe the development and validation of an assay for VA measurement in serum using a new microextraction strategy, known as BioSPME, followed by GC-MS analysis. The extraction procedure was very simple based on direct immersion of the BioSPME tips on acidified serum, followed by agitation and desorption in methanol. The methanolic extracts were directly injected into the chromatograph. Extraction yield was 95.6 to 101.3%. The assay was linear from 10 to 150 mg L-1. Precision, accuracy and stability assays were acceptable according to bioanalytical validation guidelines. The method was applied to 41 clinical serum samples also tested with a previously GC-MS validated assay, which used liquid-liquid extraction as sample preparation. Measurements obtained with both methods were comparable. This study is the first description of the use of BioSPME tips for a therapeutic drug. BioSPME is a promising alternative for the preparation of biological specimens prior to the determination of therapeutic drugs by GC-MS.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Ácido Valproico/sangue , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ácido Valproico/química , Ácido Valproico/isolamento & purificação
3.
J Pharm Biomed Anal ; 184: 113201, 2020 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-32113122

RESUMO

Amikacin (AMI) is an aminoglycoside antibiotic widely used in the treatment of severe infections caused by multi-resistant bacteria, with established exposition targets in therapeutic drug monitoring (TDM). The usual specimen for AMI concentration measurement is plasma or serum. The access to TDM of AMI in Developing Countries is constrained by the limited availability of laboratories performing the quantitation of this drug. In this context, the use of dried microsamples, such as dried plasma spots (DPS) could be an alternative to allow reduced specimen transportation and storage costs in resource-limited settings, increasing the access to TDM of AMI. This study aimed to develop and validate the first report of simultaneous determination of AMI and creatinine (CRE) in DPS, using UHPLC-MS/MS. Precision, accuracy and stability assays showed acceptable results. AMI was stable in DPS for 14 days at 6 °C, 2 days at 22 °C, and one day at 42 °C. CRE was stable during 14 days at all tested temperatures. AMI and CRE concentrations in DPS and plasma were compared by Passing-Bablok regression and Bland and Altmann plots and presented comparable results. Estimates of patient's clearance, volume of distribution and suggested doses of AMI were also similar using DPS or plasma concentrations. The assay provides a useful logistic alternative to allow more widespread access to dose individualization of AMI in limited resources settings.


Assuntos
Amicacina/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Teste em Amostras de Sangue Seco/métodos , Monitoramento de Medicamentos/métodos , Plasma/química , Espectrometria de Massas em Tandem/métodos , Amicacina/sangue , Amicacina/química , Bioensaio/métodos , Calibragem , Creatinina/sangue , Humanos , Limite de Detecção , Reprodutibilidade dos Testes
4.
Clin Biochem ; 70: 39-45, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31228434

RESUMO

BACKGROUND: Amikacin (AMI) and vancomycin (VAN) are antibiotics largely used in intensive care in the empiric treatment of severe infections by multi-resistant gram-negative and gram-positive bacteria. AMI and VAN are eliminated untransformed by glomerular filtration, showing depuration ratio highly correlated with creatinine (CRE) clearance. AMI, VAN and CRE are highly polar structures, presenting poor retention in reversed-phase liquid chromatography when using conventional stationary phases. OBJECTIVE: This study aimed to develop and validate a simple UPLC-MS/MS method for simultaneous determination of AMI, VAN, and CRE in human plasma for therapeutic drug monitoring. RESULTS: Samples were prepared by protein precipitation, followed by dilution. Heptafluorobutyric acid (HFBA) was added to the mobile phase at low concentration (0.01%), and separation was performed in an ultra-performance reversed-phase column (particle diameter of 1.8 µm). These conditions allowed retention times of 0.92, 0.93, 2.12, 2.17 and 2.27 min for CRE, CRE-D3, AMI, KAN and VAN, respectively. The assay was linear from 0.5 to 100 mg L-1 for AMI and VAN and 5 to 100 mg L-1. Precision, accuracy and stability assays were acceptable according to bioanalytical validation guidelines. Suitable results. Matrix effects were in the range of +10.5 to +11.6% for AMI, -4.3 to -4.5% for VAN, and - 1.7 to +0.7 for CRE. CONCLUSION: The first assay for the simultaneous determination of AMI, VAN and CRE in plasma by liquid chromatography-tandem mass spectrometry was reported. This assay allows the obtention of the necessary analytical data for the clinical application of population pharmacokinetic methods for therapeutic drug monitoring of AMI and VAN.


Assuntos
Amicacina/sangue , Cromatografia Líquida/métodos , Creatinina/sangue , Monitoramento de Medicamentos/métodos , Espectrometria de Massas em Tandem/métodos , Vancomicina/sangue , Antibacterianos/sangue , Humanos , Limite de Detecção , Reprodutibilidade dos Testes
5.
Forensic Sci Int ; 298: 408-416, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30954922

RESUMO

Cocaine (COC) is one of the most widely abused drugs in the world and its sensitive and its reliable measurement in blood is of great importance in the field of forensic and clinical toxicology. Additionally, the determination of COC metabolites such as benzoylecgonine (BZE), cocaethylene (CE), ecgonine methyl ester (EME), and norcocaine (NCOC) are also of complementary diagnostic value. The quantification of COC and metabolites in dried blood spots (DBS) may be an alternative to conventional collection methods with several advantages, including easier, on-site, collection, transportation and storage. In this study, we present a simple and comprehensively validated UPLC-MS/MS assay to measured COC, BZE, EME, NCOC and CE in DBS. The evaluated assay was linear from 5-500 ng mL-1. Precision assays presented CV% of 1.27-6.82, and accuracy in the range of 97-113.78%. Low haematocrit values had a negative impact in the assay accuracy. COC, BE, NCOC and CE measurements can be made reliably in DBS stored for 14 days at room temperature, as well as at -20 °C and 45 °C. All evaluated compounds can be measured in DBS maintained at -20 °C for 14 days. DBS sampling can be used for the clinical evaluation of the exposure to COC, being an alternative for collection, short-term storage and transportation of blood at room and high temperatures.


Assuntos
Manchas de Sangue , Cocaína/sangue , Entorpecentes/sangue , Cromatografia Líquida de Alta Pressão , Cocaína/análogos & derivados , Hematócrito , Humanos , Reprodutibilidade dos Testes , Manejo de Espécimes , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...