RESUMO
In the present study a hybrid molecularly imprinted poly(methacrylic acid-trimethylolpropane trimethacrylate)-silica (MIP) was synthesized and modified with (3-glycidyloxypropyl)trimethoxysilane (GPTMS) with posterior opening of epoxy ring to provide hydrophilic properties of material in the extraction of folic acid from aqueous medium. The chemical and structural aggregates of hybrid material were characterized by means of Fourier Transform Infrared (FT-IR), Transmission Electron Microscopy (TEM), Scanning Electron Microscopy (SEM), Thermogravimetric analysis (TGA) and textural data. Selectivity data of MIP were compared to non-imprinted polymer (NIP) through competitive sorption studies in the presence of caffeine, paracetamol or 4-aminobenzamide yielding relative selectivity coefficients (k') higher than one unit, thus confirming the selective character of MIP even in the presence of structurally smaller compounds than the folic acid. The lower hydrophobic sorption by bovine serum albumin (BSA) in the MIP as compared to unmodified MIP proves the hydrophilicity of polymer surface by using GPTMS with opening ring. Under acid medium(pH 1.5) the sorption of folic acid onto MIP from batch experiments was higher than the one achieved for NIP. Equilibrium sorption of folic acid was reached at 120 min for MIP, NIP and MIP without GPTMS and kinetic sorption data were well described by pseudo-second-order, Elovich and intraparticle diffusion models. Thus, these results indicate the existence of different binding energy sites in the polymers and a complex mechanism consisting of both surface sorption and intraparticle transport of folic acid within the pores of polymers.
Assuntos
Ácido Fólico/isolamento & purificação , Impressão Molecular/métodos , Ácidos Polimetacrílicos/química , Silanos/química , Dióxido de Silício/química , Adsorção , Animais , Bovinos , Ácido Fólico/análise , Concentração de Íons de Hidrogênio , Soroalbumina Bovina , TermodinâmicaRESUMO
The present paper describes the synthesis of a new chemically modified cellulose microfiber through oxidation with sodium periodate and functionalization with N,N'-bis (2-aminoethyl)-1,2-ethanediamine for the fast and selective preconcentration of Cd(II) ions in flow system analysis. The new sorbent was characterized by FTIR, SEM, and surface area values. The uptake behavior of Cd(II) ions onto this sorbent was evaluated from kinetic data, pseudo-first-order and pseudo-second-order models, as well as from Langmuir, Freundlich and Langmuir-Freundlich adsorption isotherms. The maximum sorption capacity of 4.59 mg g(-1) was estimated by the Langmuir-Freundlich model with fast kinetics for the sorption of Cd(II) described by the pseudo-second-order kinetic model. After characterization, the sorbent was packed in a mini-column, and a fast flow injection preconcentration system for Cd(II) determination by FAAS was developed. The best Cd(II) preconcentration condition, obtained by means of factorial design and response surface methodology, was achieved at pH 9.36 and a flow rate of 10 mL min(-1) followed by elution with 1.0 mol L(-1) nitric acid. By using 78 s preconcentration time, fast and highly sensitive determination of Cd(II) ions could be achieved with a limit of quantification of 0.20 µg L(-1), preconcentration factor of 26, consumption index of 0.5 mL, concentration efficiency of 20 min(-1), and sample throughput of 39 h(-1). The repeatability for 10 replicate determinations was found to be 7.8 and 2.5% for Cd(II) ion concentrations of 5.0 and 100.0 µg L(-1), respectively. The new sorbent efficiency for the interference-free preconcentration of Cd(II) ions was assessed by analysis of tap, mineral and lake waters, as well as synthetic seawater and normal saline waters. Furthermore, complex samples, such as biological samples, could be analysed by the proposed method in accordance with the accuracy attested by analysis of certified reference materials, TORT-2 (lobster hepatopancreas), and DOLT-4 (dogfish liver).
RESUMO
A novel ion imprinted polyvinylimidazole-silica hybrid copolymer (IIHC) was synthesized and used as a selective solid sorbent for Pb(2+) ions preconcentration using an on-line solid phase extraction (SPE) system coupled to TS-FF-AAS. The ionic hybrid sorbent was prepared using 1-vinylimidazole and 3-(trimethoxysilyl)propylmethacrylate as monomers, Pb(2+) ions as template, tetraethoxysilane as reticulating agent and 2,2'-azobis-isobutyronitrile as initiator. The best on-line SPE conditions concerning sorption behavior, including sample pH (6.46), buffer concentration (9.0 mmol L(-1)), eluent (HNO(3)) concentration (0.5 mol L(-1)) and preconcentration flow rate (4.0 mL min(-1)), were optimized by means of full factorial design and Doehlert matrix. The analytical curve ranged from 2.5 to 65.0 µg L(-1) (r=0.999) with limit of detection of 0.75 µg L(-1); the precision (repeatability) calculated as relative standard deviation (n=10) was 5.0 and 3.6% for Pb(2+) concentration of 10.0 and 60.0 µg L(-1), respectively. From on-line breakthrough curve, column capacity was 3.5 mg g(-1). Preconcentration factor (PF), consumptive index (CI) and concentration efficiency (CE) were 128.0, 0.16 mL and 25.6 min(-1), respectively. The selective performance of the sorbent, based on relative selectivity coefficient, was compared to NIC (non imprinted copolymer) for the binary mixture Pb(2+)/Cd(2+), Pb(2+)/Cu(2+) and Pb(2+)/Zn(2+). The results showed that ion imprinted polyvinylimidazole-silica hybrid polymer had higher selectivity for Pb(2+) than NIC at 64.9, 16.0 and 8.8 folds. The developed method was successfully applied for highly sensitive and selective Pb(2+) determination in different kinds of water samples, parenteral solutions and urine. Accuracy was also assessed by analyzing certified reference fish protein (DORM-3) and marine sediment (MESS-3 and PACS-2) with satisfactory results.