Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 261(6): 1627-1637, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36633667

RESUMO

PURPOSE: To investigate the impact of Boston Type I Keratoprosthesis (BI-Kpro) implantation on retinal and visual pathway function, respectively, assessed by full-field electroretinography (ERG) and visually evoked potentials (VEPs). METHODS: This is a prospective interventional longitudinal study, and patients with BI-Kpro implantation were assessed preoperatively and at 3 and 12 months after surgery. ERG, flash, and pattern-reversal VEPs (15' and 60' checks) along with visual acuity (VA) were performed. RESULTS: A total of 13 patients (24 to 88 years of age) were included. Mean baseline VA (logMAR) improved from 2.30 to 1.04 at 3 months and to 1.00 at 12 months. Flash VEPs were normal in 6 (46%) patients and in 10 (77%) patients at the 12-month follow-up. PVEP was non-detectable in all patients preoperatively for both check sizes. For 15' check size, 6 (46%) patients showed responses after 3 and 12 months except for 1 patient with normal responses at 12 months with the remaining non-detectable. For 60' checks, 11 (85%) patients had responses 3 months after surgery with only 9 (70%) showing responses at 12 months. Abnormal full-field ERGs were found in all patients preoperatively. Amplitude improvement was found in 10 (77%) patients from baseline to 3 months and in 8 (62%) patients from the 3- to the 12-month follow-up. CONCLUSIONS: In this small cohort of patients with BI-Kpro implantation, a remarkable improvement on visual function quantitatively assessed by electrophysiological testing was found in the majority of cases. Visual electrophysiological testing can contribute to objectively assess functional outcomes in this population.


Assuntos
Córnea , Doenças da Córnea , Humanos , Córnea/cirurgia , Vias Visuais , Estudos Prospectivos , Estudos Longitudinais , Próteses e Implantes , Doenças da Córnea/cirurgia , Potenciais Evocados Visuais
2.
Ocul Immunol Inflamm ; 31(4): 701-709, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35404738

RESUMO

PURPOSE: To analyze and compare the tear immunological profile in ocular GVHD (oGVHD) patients with that in non-oGVHD patients and to correlate them with ocular surface parameters based on the International Chronic Ocular GVHD Consensus Group (ICCGVHD) diagnostic criteria. METHODS: Tear samples from 20 individuals who underwent allo-hematopoietic stem cell transplantation and were grouped according the presence or absence of oGVHD were analyzed using Bio-Plex assay. RESULTS: IL-8 and MIP-1α levels were significantly higher in tears from oGVHD patients compared with those in tears from non-oGVHD patients (p<0.001 and p=0.001, respectively). Tear IL-8 levels correlated significantly with OSDI criteria (ρ=0.5159, p=0.001), ocular hyperemia (ρ=0.469, p=0.002), and corneal staining (ρ=0.339, p=0.032), whereas tear Mip-1α levels correlated with OSDI score (ρ=0.358, p=0.023). CONCLUSION: We demonstrated higher tear levels of IL-8 and MIP-1α in oGVHD patients and significant correlations between theses cytokines and ocular surface parameters based on the ICCGVHDCG criteria.


Assuntos
Síndromes do Olho Seco , Doença Enxerto-Hospedeiro , Humanos , Quimiocina CCL3/metabolismo , Interleucina-8/metabolismo , Olho , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/metabolismo , Lágrimas/metabolismo , Doença Enxerto-Hospedeiro/diagnóstico
3.
Br J Ophthalmol ; 106(4): 458-460, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34758962

RESUMO

Individuals with suspected COVID-19 symptoms (n=202) were tested using nasopharyngeal RT-qPCR. All individuals underwent corneal esthesiometry measurements using the Cochet-Bonnet esthesiometer during their first visit; 50 participants underwent an additional measurement at a mean interval of 32.5 (17.8) days. COVID-19 was confirmed in 101 subjects (50%) using nasopharyngeal PCR. The mean time from symptom onset to disease diagnosis and corneal esthesiometry was 4.2 (2.1) days. Mean corneal esthesiometry findings based on the positive and negative PCR status indicated no statistical difference. This study demonstrated that COVID-19 had no effect on corneal esthesiometry in individuals with acute-phase COVID-19.


Assuntos
COVID-19 , Córnea , Humanos
5.
Case Rep Ophthalmol ; 12(1): 146-149, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33976672

RESUMO

We report a case of a patient with necrotizing infection of the conjunctiva and Tenon's capsule caused by Streptococcus pyogenes, a rare and atypical ophthalmologic condition. A 50-years-old male patient with acute red-eye, purulent discharge, and pain diagnosed with post-septal cellulitis presented with a yellowish and dense membrane covering the ocular surface with necrotic Tenon's capsule. Patient was hospitalized, and intravenous antibiotics were initiated (ceftriaxone and clindamycin). Topical antibiotics and corticosteroids were also administered, and the infection was eradicated in 2 weeks. Ancillary exams excluded rheumatologic involvement. Conjunctival culture confirmed Streptococcus pyogenes growth. Tenon's biopsy revealed unspecific acute inflammatory necrosis. This is an uncommon condition in daily ophthalmological clinic. Literature review reported 3 cases associated with previous ocular surgery.

6.
Front Physiol ; 12: 612319, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33643063

RESUMO

Coronaviruses gained public attention during the severe acute respiratory syndrome (SARS) outbreak in East Asia in 2003 and spread of Middle Eastern respiratory syndrome (MERS) in 2012. Direct human-to-human contact and droplet are the main methods of transmission. Viral stability in aerosols on different surfaces supports evidence on indirect viral acquisition from fomites through the mucous membranes of the mouth, nose, and eyes. Given the pandemic circumstances, the level of evidence in COVID-19 and ophthalmology regarding eye infection, conjunctival transmission, and viral shedding through tears is insufficient. Presently, conjunctival transmission of coronaviruses has not been confirmed and remains controversial. Considering the physiology of the lacrimal system and ocular surface, the eyes are considered an immunoprotective site, with several antiviral molecules and anti-inflammatory proteins. Nevertheless, they represent an interface with the exterior world and face daily putative aggressors. Understanding the host's ocular surface immunological and protective environment is crucial to clarify the potential of the conjunctiva as an entry route for SARS-CoV-2 and as part of this viral infection. We will discuss hypothetical ocular surface transmission mechanisms and related counterarguments addressed to both angiotensin-converting enzyme 2 receptors found on the conjunctival and corneal epithelia and lactoferrin, lysozyme, lipocalin and secretory IgA levels in the tear film. Hopefully, we will promote better understanding of this organ in COVID-19 infection and the potential transmission route that can be helpful in setting recommendations on best practices and protective guidelines to mitigate the disease spread.

7.
Int J Ophthalmol ; 11(5): 807-812, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29862180

RESUMO

AIM: To compare the functional and anatomic results of femtosecond laser (FSL)-assisted deep anterior lamellar keratoplasty (DALK) associated with phototherapeutic keratectomy (PTK) and FSL-assisted DALK performed using the big-bubble technique in keratoconus. METHODS: During the first phase of the study, an electron microscopy histopathology pilot study was conducted that included four unsuitable donor corneas divided into two groups: in FSL group, FSL lamellar cuts were performed on two corneas and in FSL+PTK group, PTK was performed at the stromal beds of two corneas after FSL lamellar cuts were made. During the second phase of the study, a randomized clinical trial was conducted that included two treatment groups of patients with keratoconus: group 1 (n=14 eyes) underwent FSL-assisted DALK associated with PTK and group 2 (n=12 eyes) underwent FSL-assisted DALK associated with the big-bubble technique. The main outcome measures were the postoperative visual acuity (VA) and optical coherence tomography (OCT) measurements, confocal microscopic findings, and contrast sensitivity. RESULTS: In the pilot study, histopathology showed a more regular stromal bed in the FSL+PTK group. In the clinical trial, group 1 had significantly worse best spectacle-corrected VA and contrast sensitivity (P<0.05 for both comparisons). The residual stromal bed measured by OCT was significantly (P<0.05) thicker in group 1. Confocal microscopy detected opacities only at the donor-receptor interface in group 1. CONCLUSION: Patients with keratoconus treated with FSL-assisted DALK performed using the big-bubble technique fare better than treated with FSL-assisted DALK associated with PTK.

8.
Am J Ophthalmol Case Rep ; 6: 71-73, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29260063

RESUMO

PURPOSE: To report the outcomes of implantation of the Boston Type I keratoprosthesis in three patients with Acanthamoeba keratitis (AK), a severe infection that can lead to significant visual loss. OBSERVATIONS: Case series reporting three patients with difficult cases of AK that needed multiple corneal transplantations and glaucoma surgeries. All patients were implanted with the Boston Type I keratoprosthesis device. The main outcomes measure were the visual function and anatomical retention after implantation of the Boston Type I keratoprosthesis. All patients retained the device over the long-term and had good visual function. In one patient a retroprosthetic membrane developed and in another patient an epithelial lip developed over the anterior surface of the keratoprosthesis. The visual acuities range from 20/25 to 20/80 in the implanted eyes. CONCLUSIONS AND IMPORTANCE: The Boston Type I keratoprosthesis resulted in good anatomic and functional results after multiple graft failures after AK.

9.
Can J Ophthalmol ; 49(4): 351-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25103652

RESUMO

OBJECTIVE: To report the experience of the Federal University of São Paulo, Brazil, in performing Boston keratoprosthesis type 1 implantation in the developing world. METHODS: We analyzed 30 eyes of 30 patients who underwent Boston type 1 keratoprosthesis surgery between 2008 and 2012 in a prospective interventional study. Preoperative, perioperative, and postoperative parameters were analyzed, including visual acuity (VA), keratoprosthesis stability, and postoperative complications. RESULTS: Preoperative diagnoses were failed grafts in 16 eyes (53.33%), chemical injury in 10 eyes (33.33%) and Stevens-Johnson syndrome in 4 eyes (13.33%). Also, 16 eyes (53.33%) had preoperative glaucoma. Preoperative best corrected VA ranged from 20/400 to light perception. With an average follow-up of 32 months (range 1-55 months), postoperative vision improved to >20/200 in 24 eyes (80%). Postoperative VA was statistically improved compared with the preoperative measurement during all postoperative follow-ups (up to 36 months). During the follow-up period (32 months), retention of the initial keratoprosthesis was 93.3%. The incidence of retroprosthetic membrane was 26.66%. Progression of glaucoma occurred in 7 of 16 eyes (43%). Three patients experienced development of glaucoma after keratoprosthesis implantation. One eye experienced development of infectious keratitis, and 2 eyes had retinal detachment. CONCLUSIONS: Performing Boston type 1 keratoprosthesis in a developing country is a viable option after multiple keratoplasty failures and conditions with a poor prognosis for keratoplasty. Our experience appears similar to major reports in the field from investigators in developed countries. Adjustments to postoperative management must be considered according to the particular location.


Assuntos
Órgãos Bioartificiais , Bioprótese , Córnea , Países em Desenvolvimento , Adulto , Brasil , Doenças da Córnea/cirurgia , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Próteses e Implantes , Implantação de Prótese , Acuidade Visual/fisiologia
10.
Acta Ophthalmol ; 91(6): e432-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23406295

RESUMO

PURPOSE: To report the outcomes of Boston type I keratoprosthesis (BKPro) in the management of ocular burn injuries. METHODS: This was a prospective study including all cases of BKPro implantation for ocular burns at the External Diseases and Cornea Service of the Federal University of São Paulo, between February 2008 and February 2010. Ten patients (10 eyes) were enrolled. Procedures performed to manage ocular injury were identified, and data were collected regarding patients' ocular history, surgical procedure(s) performed, and postoperative outcomes, including visual acuity, retention, complications and required surgical procedures. RESULTS: A total of 11 Type 1 BKPro were implanted in 10 eyes of 10 patients. The mean follow-up period was 25.7 ± 10.8 months. Preoperative best-corrected visual acuity (BCVA) ranged from count fingers to light perception. Postoperative BCVA was better than 20/200 in 90% of the patients and better than 20/60 in 60% of the patients. The overall BKPro retention rate was 90%. The most common complications were retroprosthetic membrane formation (50%) and persistent corneal epithelial defect evolving to corneal melting (40%). Patients who underwent ocular surface procedures such as limbal transplantation prior to BKPRo implantation had a lower incidence of corneal melting/thinning (p = 0.07), although this was not statistically significant. CONCLUSION: The anatomical and functional results identified in this study support the use of BKPro in managing bilateral limbal stem cell deficiency secondary to ocular burns.


Assuntos
Órgãos Artificiais , Bioprótese , Queimaduras Químicas/cirurgia , Doenças da Córnea/cirurgia , Queimaduras Oculares/induzido quimicamente , Implantação de Prótese , Adulto , Álcalis , Doenças da Córnea/induzido quimicamente , Queimaduras Oculares/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
11.
Cornea ; 32(4): 407-11, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22488148

RESUMO

PURPOSE: To evaluate the efficacy of a prophylactic regimen of daily topical 0.5% moxifloxacin and 5% povidone-iodine (PI) in patients with Boston type I keratoprosthesis (KPro) and to assess the applicability of a novel molecular diagnostic technique to analyze the ocular surface microbiota in these patients. METHODS: Ten patients had their inferior conjunctival fornix sampled for standard culture methods before the addition of topical 5% PI to the prophylactic regimen and were considered the control group (group 1). The inferior conjunctival fornix and the KPro-donor cornea interface of 10 patients treated with the mentioned prophylactic regimen were sampled and analyzed by standard culture methods and using a polymerase chain reaction/electrospray ionization mass spectrometry assay (group 2). RESULTS: Samples from the inferior conjunctival fornix were positive for coagulase-negative staphylococcus in 3 patients and for Aerobasidium pullulans in 1 patient in group 1. The inferior conjunctival fornix and the KPro-donor cornea interface scrapings were positive for coagulase-negative staphylococcus in 2 patients and 1 patient, respectively, in group 2. No bacteria and fungi growth were detected in any patient from group 2 with the molecular diagnostic approach. None of the patients with culture-positive results developed keratitis or endophthalmitis during the study. CONCLUSIONS: Topical 0.5% moxifloxacin associated with topical 5% PI is an effective prophylactic regimen in patients with Boston type I KPro. The molecular diagnostic approach using serial polymerase chain reaction and mass spectrometry was comparable with standard microbiologic techniques as a surveillance tool in these patients.


Assuntos
Compostos Aza/administração & dosagem , Infecções Oculares Bacterianas/prevenção & controle , Infecções por Bactérias Gram-Positivas/prevenção & controle , Povidona-Iodo/administração & dosagem , Próteses e Implantes/efeitos adversos , Quinolinas/administração & dosagem , Adulto , Antibacterianos/administração & dosagem , Anti-Infecciosos Locais/administração & dosagem , Antibioticoprofilaxia , Doenças da Córnea/cirurgia , Quimioterapia Combinada , Endoftalmite/prevenção & controle , Infecções Oculares Bacterianas/etiologia , Infecções Oculares Bacterianas/microbiologia , Feminino , Fluoroquinolonas , Humanos , Masculino , Técnicas de Diagnóstico Molecular/métodos , Moxifloxacina , Estudos Prospectivos , Staphylococcus aureus/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA