1.
Restor Dent Endod ; 41(4): 271-277, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27847748

RESUMO

OBJECTIVES: In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs) on the degree of conversion (DC) and the mechanical properties of resin cements. MATERIALS AND METHODS: Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG), according to the different radiant exposures (5, 10, and 20 J/cm2) and two LCUs (single-peak and polywave). The specimens were made (7 mm in length × 2 mm in width × 1 mm in height) using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E) by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA) and post hoc Tukey's test were performed. RESULTS: No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. CONCLUSIONS: On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

2.
J Adhes Dent ; 15(2): 145-50, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23534019

RESUMO

PURPOSE: To evaluate the microshear bond strength of resin cements to yttrium-stabilized tetragonal zirconium oxide surfaces after water storage for 24 h or 1 year. MATERIALS AND METHODS: Four self-adhesive (BisCem, G-Cem, RelyX Unicem, SeT) and one conventional resin cement (RelyX ARC) were tested. The materials were mixed and inserted in tubes (0.75 mm diameter × 1 mm height) that were placed over the zirconium oxide surface. Specimens were tested after 24-h or 1-year water storage. Microshear testing was performed using a universal testing machine. Shear bond strength results were analyzed using two-way ANOVA and Tukey's test (5%). RESULTS: After 24-h water storage, no difference was found between G-Cem and RelyX Unicem resin cements; however, their bond strength means to zirconium oxide were statistically higher than RelyX ARC. The bond strength values of all resin cements dropped significantly after 1 year of water storage. G-Cem presented the highest values among cements after long-term water exposure. CONCLUSIONS: One-year water storage decreased the microshear bond strengths to zirconium oxide for all resin cements tested.


Assuntos
Colagem Dentária , Porcelana Dentária , Cimentos de Resina , Falha de Restauração Dentária , Análise do Estresse Dentário , Armazenamento de Medicamentos , Teste de Materiais , Cimentos de Resina/química , Resistência ao Cisalhamento , Água , Ítrio , Zircônio
3.
Lasers Med Sci ; 28(4): 1069-76, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22886136

RESUMO

UNLABELLED: This study evaluated the effects of different parameters of dentin irradiation with erbium -doped yttrium aluminum garnet (Er:YAG) laser on bond strength to dentin and analyzed the ultramorphological characteristics of resin-laser-irradiated dentin interfaces using a transmission electron microscope (TEM). Dentin surfaces were abraded with SiC paper (600 grit) or Er:YAG laser-irradiated (120/4, 140/6, 180/4, or 200/6 mJ/Hz). Three adhesive systems were tested: Single Bond Plus (3M ESPE), Clearfil Protect Bond (Kuraray Med.), and Clearfil Tri-S Bond (Kuraray Med.). Treatments were performed over flat dentin surfaces of human third molars. Specimens were stored in distilled water for 1 week or 6 months and prepared for a microtensile bond strength test and interfacial ultrastructure for analysis. Microtensile bond strength data (n = 5) were analyzed with three-way analysis of variance. Irradiation with Er:YAG laser did not reduce the bond strength values for self-etching adhesives even after 6 months of water storage. The hybrid layer formation was observed only when the adhesives were applied to non-irradiated dentin (control group). Nanoleakage occurred in all resin-dentin interfaces using Single Bond Plus for both periods. Nanoleakage pattern and bond strength of self-etching adhesives to dentin were less affected by Er:YAG laser irradiation and by the 6-month storage in water than was those of the etch-and-rinse adhesive. TEM analysis revealed no hybridization when dentin was laser-irradiated. CLINICAL SIGNIFICANCE: Minimally invasive caries removal has been proposed. Nevertheless, bonding mechanisms to lased dentin are not entirely described. Knowing the interaction between the treated dentin and bonding agents and its behavior over time is of utmost importance for new technologies. Regarding that, two-bottle self-etching adhesive system provided a more consistent evidence of its better behavior when bonding to lased substrate.


Assuntos
Dentina/efeitos da radiação , Lasers de Estado Sólido/uso terapêutico , Cura Luminosa de Adesivos Dentários/métodos , Cimentos Dentários/uso terapêutico , Corrosão Dentária/métodos , Dentina/ultraestrutura , Humanos , Microscopia Eletrônica de Transmissão , Resinas Sintéticas/uso terapêutico , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
4.
Photomed Laser Surg ; 29(11): 747-52, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21923283

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effects of Er,Cr:YSGG laser irradiation and different adhesive procedures on bond strength of two bonding agents to dentin. BACKGROUND DATA: Studies have shown that laser-irradiated dentinal tissue yields lower bond strengths than does nonirradiated dentin. In this study, different treatment methods of laser irradiating dentin were studied to enhance the bond strength of bonding agents to nonirradiated dentin. METHODS: Third molars were wet ground with SiC until the occlusal flat dentin surface was exposed, and the teeth were randomly assigned to six groups (n=5). A two-step self-etching primer (Clearfil SE Bond, G1) and a two-step etch-and-rinse adhesive (Single Bond Plus, G2) were applied to the nonirradiated dentin surface according to manufacturer's instructions, as control groups. In G3 and G4, the same adhesives were applied after Er,Cr:YSGG laser irradiation, whereas in G5 and G6 adhesives were applied after Er,Cr:YSGG laser irradiation, phosphoric acid etching, and NaOCl deproteinization of etched dentin. The Er,Cr:YSGG laser worked at 2.78??m and the repetition rate was fixed at 20?Hz. Composite blocks were built on bonded surfaces and the teeth were stored for 24?h at 37?C. Restored teeth were vertically and serially sectioned to obtain bonded specimens for the bond strength test. Data were analyzed by two-way ANOVA and Tukey test (?=5%). RESULTS: Laser irradiation reduced bond strengths for the two adhesives, regardless of acid etching and deproteinization of dentin post-irradiation (p<0.05). The self-etching primer system showed higher bond strengths to laser irradiated dentin than did Single Bond Plus (p<0.05). The adhesive systems applied to normal dentin yielded higher bond strengths than when they were applied to laser irradiated dentin (p<0.05). CONCLUSIONS: The self-etching primer seemed to be less affected by dentin irradiation with Er,Cr:YSGG laser. The additional etching and NaOCl solution did not overcome the effects of laser irradiation on dentin.


Assuntos
Colagem Dentária , Lasers de Estado Sólido , Lasers , Dentina/efeitos da radiação , Adesivos Dentinários/farmacologia , Humanos , Técnicas In Vitro , Distribuição Aleatória
5.
Lasers Surg Med ; 42(7): 662-70, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20806391

RESUMO

BACKGROUND AND OBJECTIVES: This study evaluated the hybrid layer (HL) morphology created by three adhesive systems (AS) on dentin surfaces treated with Er:YAG laser using two irradiation parameters. STUDY DESIGN: Occlusal flat dentin surfaces of 36 human third molars were assigned into nine groups (n = 4) according to the following ASs: one bottle etch&rinse Single Bond Plus (3M ESPE), two-step Clearfil Protect Bond (Kuraray), and all-in-one S(3) Bond (Kuraray) self-etching, which were labeled with rhodamine B or fluorescein isothiocyanate-dextran and were applied to dentin surfaces that were irradiated with Er:YAG laser at either 120 (38.7 J/cm(2)) or 200 mJ/pulse (64.5 J/cm(2)), or were applied to untreated dentin surfaces (control group). The ASs were light-activated following MI and the bonded surfaces were restored with resin composite Z250 (3M ESPE). After 24 hours of storage in vegetable oil, the restored teeth were vertically, serially sectioned into 1-mm thick slabs, which had the adhesive interfaces analyzed with confocal laser microscope (CLSM-LSM 510 Meta). CLSM images were recorded in the fluorescent mode from three different regions along each bonded interface. RESULTS: Non-uniform HL was created on laser-irradiated dentin surfaces regardless of laser irradiation protocol for all AS, while regular and uniform HL was observed in the control groups. "Stretch mark"-like red lines were found within the HL as a result of resin infiltration into dentin microfissures, which were predominantly observed in 200 mJ/pulse groups regardless of AS. Poor resin infiltration into peritubular dentin was observed in most regions of adhesive interfaces created by all ASs on laser-irradiated dentin, resulting in thin resin tags with neither funnel-shaped morphology nor lateral resin projections. CONCLUSION: Laser irradiation of dentin surfaces at 120 or 200 mJ/pulse resulted in morphological changes in HL and resin tags for all ASs evaluated in the study.


Assuntos
Colagem Dentária/métodos , Corrosão Dentária/métodos , Dentina/citologia , Lâmpadas de Polimerização Dentária , Cimentos Dentários/classificação , Adesivos Dentinários/química , Humanos , Lasers , Lasers de Estado Sólido , Microscopia Confocal , Dente Serotino , Cimentos de Resina/química , Propriedades de Superfície/efeitos da radiação , Resistência à Tração/efeitos da radiação
6.
J Prosthodont ; 19(2): 125-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20002979

RESUMO

PURPOSE: The aim of this study was to evaluate the effectiveness of adhesive primers (APs) applied to Co-Cr and Ni-Cr metal alloys on the bond strength of resin cements to alloys. MATERIALS AND METHODS: Eight cementing systems were evaluated, consisting of four resin cements (Bistite II DC, LinkMax, Panavia F 2.0, RelyX Unicem) with or without their respective APs (Metaltite, Metal Primer II, Alloy Primer, Ceramic Primer). The two types of dental alloys (Co-Cr, Ni-Cr) were cast in plate specimens (10 x 5 x 1 mm(3)) from resin patterns. After casting, the plates were sandblasted with aluminum oxide (100 microm) and randomly divided into eight groups (n = 6). Each surface to be bonded was treated with one of eight cementing systems. Three resin cement cylinders (0.5 mm high, 0.75 mm diameter) were built on each bonded metal alloy surface, using a Tygon tubing mold. After water storage for 24 hours, specimens were subjected to micro-shear testing. Data were statistically analyzed by two-way ANOVA and Tukey's studentized range test. RESULTS: The application of Metal Primer II resulted in a significantly higher bond strength for LinkMax resin cement when applied in both metal alloys. In general, the cementing systems had higher bond strengths in Co-Cr alloy than in Ni-Cr. CONCLUSIONS: The use of AP between alloy metal surfaces and resin cements did not increase the bond strength for most cementing systems evaluated.


Assuntos
Ligas de Cromo , Cimentos de Resina , Autocura de Resinas Dentárias , Adesivos , Análise de Variância , Cobalto , Análise do Estresse Dentário , Teste de Materiais , Níquel , Distribuição Aleatória , Resistência ao Cisalhamento , Estatísticas não Paramétricas
7.
Oper Dent ; 33(6): 682-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19051862

RESUMO

This study compared the microtensile bond strength (microTBS) of indirect resin composite restorations to dentin when fifth-generation adhesive systems were either light-activated or left in the uncured state prior to cementation. The systems used in this study were Prime&Bond NT (NT-Dentsply) and Excite (EX-Ivoclar-Vivadent) or their dual-cured versions containing co-initiators with different presentation modes (as solution or salts) Prime&Bond NT Dual-cure (NTD-Dentsply) and Excite DSC (DSC-Ivoclar Vivadent). The bonding agents were applied to the flattened occlusal dentin surfaces of 40 human third molars according to the manufacturers' instructions and were light-activated (XL3000/3M ESPE) for 10 seconds (LP) or left in the uncured state (SP). The respective resin cements Calibra (Dentsply Caulk) and Variolink II (Ivoclar Vivadent) were applied to pre-cured resin composite discs (2 mm thick/Z-250/3M ESPE) that were fixed to the bonded dentin surfaces. The restored teeth were light-activated according to the manufacturers' instructions for five minutes after cementation and water-stored at 37 degrees C for 24 hours. The teeth were then both mesial-distally and buccal-lingually sectioned to obtain bonded specimens (0.8 mm2). Each specimen was tested in tension at a crosshead speed of 0.5 mm/minute until failure. The data (MPa [SD]) were analyzed by 3-way ANOVA and Tukey's post-hoc test (p < .05). The results showed that the presence of a co-initiator decreased microTBS for NT, while no significant difference in microTBS was noted between EX and DSC, regardless of the curing mode. All SP groups exhibited lower microTBS than the LP groups. The results suggest that coinitiators presented as a solution may decrease microTBS to dentin of the evaluated adhesive systems in indirect resin composite restorations. Light-activation of the adhesive layer prior to indirect cementation was crucial for higher microTBS on dentin.


Assuntos
Resinas Compostas , Adesivos Dentinários/química , Restaurações Intracoronárias , Cimentos de Resina/química , Autocura de Resinas Dentárias/métodos , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Resistência à Tração
8.
Eur J Dent ; 1(3): 158-66, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19212560

RESUMO

OBJECTIVES: Different surface treatments may affect bonding performance of adhesive systems to dentin. This study evaluated the influence of different methods of surface treatment on adhesion of bonding agents to dentin. METHODS: Dentin surfaces abraded with #600-grit SiC paper were used as control. Three methods of surface treatment (sono-abrasion, air-abrasion and Er:YAG laser irradiation) were used under specific parameters. Four adhesive systems (Tyrian, Clearfil SE Bond, Unifil Bond and Single Bond) were applied to treated surfaces, according to the manufacturers' instructions. Composite blocks were built on bonded surfaces, then restored teeth were vertically and serially sectioned to obtain bonded slices for interfacial micromorphologic analysis or to produce beam specimens for mu-TBS bond test. Data were analyzed with two-way ANOVA and Tukey test at a significance level of 5%. RESULTS: The results indicated that the preparation of dentin with sono-abrasion or laser did not affect the bond strength, while the preparation of dentin with SiC paper and air-abrasion influenced the bond strength for some systems. A clear difference of the preparation of dentin surfaces and formation of hybrid layer and resin tags were noted. CONCLUSION: Bonding effectiveness of both the etch-and-rinse and the self-etch adhesives can be influenced by different methods of dentin preparation.

9.
J Appl Oral Sci ; 14(6): 427-35, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19089243

RESUMO

OBJECTIVE: Although self-etching bonding systems (SES) are indicated to prepare dental enamel for bonding, concerns have been expressed regarding their effectiveness. The aim of this study was to analyze the etching pattern (EP) of nine SES in comparison with 35% and 34% phosphoric acid etchants (FA) on intact (IN) and ground (GR) enamel surface. MATERIALS AND METHODS: Twenty-two human third molars were sectioned in mesial-distal and buccal-lingual directions, and four dental fragments were obtained from each tooth. Half of the fragments were ground using 600-grit SiC paper and the other half remained intact. The fragments were randomly assigned into 22 groups, according to the texture of enamel surface (IN and GR) and the technique to etch the enamel (34% FA, 35% FA, AdheSE primer; Brush & Bond; Clearfil Protect Bond primer; iBond; One-up Bond F; OptiBond Solo Plus primer; Tyrian SPE primer; Unifil Bond primer and Xeno III). Conditioners were applied to IN and GR enamel surfaces, according to the manufacturer's instructions. Specimens etched with phosphoric acids were washed with water, while the surfaces treated with SES were submitted to alternate rinsing with alcohol and acetone. The specimens were dried, sputter-coated and examined under a scanning electron microscope. RESULTS: For both IN and GR enamel surfaces, the EP of 34 and 35% FA was deeper and more homogeneous in comparison to EP of SES, except for Tyrian SPE. The acidic monomer action of self-etching systems was more effective on GR enamel. CONCLUSION: Most of the SES are less aggressive than phosphoric acid etchants and their etching effects were reduced on intact enamel surfaces.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...