1.
J Ophthalmol ; 2018: 6830835, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30116632

RESUMO

PURPOSE: To classify and quantify anthocyanins in a vital dye extracted from the acai fruit (Euterpe oleracea), adjust pH and osmolarity, and perform lyophilization to develop a new chromovitrectomy dye. METHODS: Three dye concentrations 10%, 25%, and 35% (equivalent to 100, 250, and 350 mg of lyophilized acai fruit pulp extract samples) were evaluated when diluted in 1 ml of phosphate-buffered solution (pH 7 and 300 mOsm). The dye was analyzed by mass spectrometry and high-performance liquid chromatography (HPLC) to identify and quantify anthocyanins molecules. RESULTS: The pH and osmolarity correction and lyophilization were performed without damaging the anthocyanin molecular structure. Mass spectrometry confirmed the presence of five anthocyanins in the three concentrations of the dye. Cyanidin-3-O-glucoside was the major anthocyanin found. HPLC showed that the concentration of anthocyanin was similar, independent of the dye concentration tested. CONCLUSIONS: Lyophilization and the correction of pH and osmolarity (7.00 and 300 mOsm, resp.) were performed successfully. Five anthocyanins are present in the dye from the acai fruit. The major anthocyanin is cyanidin-3-O-glucoside. Independent of the dye concentration tested, the anthocyanin concentration was similar. Standardized chemical characteristics of this new dye may allow its use during chromovitrectomy in humans.

2.
Ophthalmic Surg Lasers Imaging Retina ; 49(5): 374-379, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29772050

RESUMO

BACKGROUND AND OBJECTIVE: To report the efficacy, safety, and benefits of femtosecond laser-assisted cataract surgery (FLACS) combined with sutureless 23-gauge pars plana vitrectomy (PPV). PATIENTS AND METHODS: This multicenter, retrospective study evaluated patient records and videos of 43 cases with retinal pathologies and cataract who underwent the combined procedure. RESULTS: In 44.2% and 55.8% of cases, respectively, the LenSx Laser (femtosecond machine; Alcon, Fort Worth, TX) and the Constellation (vitreous cutter; Alcon, Fort Worth, TX), and the Victus (femtosecond machine; Bausch + Lomb, Rochester, NY) and Stellaris PC (vitreous cutter; Bausch + Lomb, Rochester, NY) were used. No complications developed during capsulorrhexis, even without a red fundus reflex, retrobulbar block, or scleral indentation. Foldable intraocular lenses remained stable in the capsular bag during the vitreoretinal surgeries and postoperative visits. The mean times of femtosecond phacoemulsification, vitreoretinal surgery, and total surgery were 22.9 minutes ± 4.7 minutes, 43.1 minutes ± 9.8 minutes, and 65.3 minutes ± 8.6 minutes, respectively. CONCLUSION: This emerging technology is safe and offers several potential benefits for the success of the combined procedure. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:374-379.].


Assuntos
Extração de Catarata/métodos , Oftalmopatias/cirurgia , Terapia a Laser/métodos , Facoemulsificação/métodos , Vitrectomia/métodos , Cirurgia Vitreorretiniana/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...