1.
Comput Methods Biomech Biomed Engin ; 22(4): 409-417, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30712384

RESUMO

To evaluate the stress behavior of ceramic fragment restoration, varying the thickness of the cement layer and intraoral temperature variation. A solid model of a upper lateral incisor was obtained and a defect at enamel distal/incisal edge was restored with a ceramic fragment. Based on this initial model, 4 different models (M) were built: M1 - absence of cement layer (CL) (0 µm of thickness); M2 - CL with an uniform thickness of 50 µm; M3 - CL with 50 µm at the margin of ceramics and 100 µm in the inner area far from margins; M4 - CL with 50 µm at the margin of ceramics and 200 µm in the inner area far from margins. The environment temperature changed from 5 °C to 50 °C in 4 increments. The finite element analysis was performed. Increase the cement layer thickness generated higher stress levels on ceramic surface in all temperatures, as well as on cement interface. In general hot temperature was the worst scenario for ceramic fragments integrity, since tensile and compressive stress were more intense. The maximum principal stress on ceramic fragment was found 90 MPa for M4 at 50 °C, followed for M3 (87 Mpa). For CL, the peak of stress was found for M3 at 5 °C (47 MPa). Is it possible to conclude that thick resin cement layer contribute to higher stress concentration on ceramic fragment, and extremely hot temperatures increase the risk of structural failure, since both ceramic and \cl are exposed to higher compressive and tensile stresses.


Assuntos
Porcelana Dentária/química , Análise do Estresse Dentário , Fenômenos Mecânicos , Cimentos de Resina/química , Temperatura , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Incisivo/anatomia & histologia , Estresse Mecânico , Propriedades de Superfície
2.
Int J Oral Maxillofac Implants ; 31(4): 884-90, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27447157

RESUMO

PURPOSE: Edentulism usually leads to esthetic, functional, and emotional discomfort resulting in a loss of self-esteem and a decrease of the patient's quality of life. Dental implants provide new possibilities to ensure the comfort and efficacy of prosthetic rehabilitation. The aim of this study was to evaluate the satisfaction level of patients rehabilitated using the Brånemark protocol or overdenture implant-supported prostheses. MATERIALS AND METHODS: Fifty-two patients were rehabilitated using the Brånemark protocol and 23 using overdenture prostheses. Then, an adapted oral health-related quality of life questionnaire was administered in addition to a clinical exam to determine the condition of the dental implants and prostheses. The results for treatment expectation, understanding of the type of treatment, phonetic function, chewing comfort, pain, and self-esteem improvement were analyzed with Fisher exact test (P ≤ .05). RESULTS: Both treatments presented satisfaction of above 87%, with no statistical difference between them. Eighty-two percent of patients treated with overdenture prostheses and 80.8% of those treated with the Brånemark protocol had no complaint of pain (P = .087). CONCLUSION: The treatments analyzed in this study were highly satisfactory with regard to functional and esthetic factors, resulting in an increase in self-esteem and quality of life. The psychological factor is a complex variable in patient satisfaction that directly influences quality of life. Considering the desires of patients in choosing the type of prosthesis is critical to treatment success.


Assuntos
Prótese Dentária Fixada por Implante/psicologia , Boca Edêntula/reabilitação , Satisfação do Paciente , Idoso , Implantes Dentários , Revestimento de Dentadura , Feminino , Seguimentos , Humanos , Masculino , Mastigação , Pessoa de Meia-Idade , Boca Edêntula/psicologia , Qualidade de Vida , Inquéritos e Questionários , Resultado do Tratamento
3.
Dent Traumatol ; 31(3): 190-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25604805

RESUMO

AIM: The aim was to evaluate the biomechanical behavior of the supporting bony structures of replanted teeth and the periodontal ligament (PDL) of adjacent teeth when orthodontic wires with different mechanical properties are applied, with three-dimensional finite element analysis. MATERIALS AND METHODS: Based on tomographic and microtomographic data, a three-dimensional model of the anterior maxilla with the corresponding teeth (tooth 13-tooth 23) was generated to simulate avulsion and replantation of the tooth 21. The teeth were splinted with orthodontic wire (Ø 0.8 mm) and composite resin. The elastic modulus of the three orthodontic wires used, that is, steel wire (FA), titanium-molybdenum wire (FTM), and nitinol wire (FN) were 200 GPa, 84 GPa, and 52 GPa, respectively. An oblique load (100 N) was applied at an angle of 45° on the incisal edge of the replanted tooth and was analyzed using Ansys Workbench software. The maximum (σmax) and minimum (σmin) principal stresses generated in the PDL, cortical and alveolar bones, and the modified von Mises (σvM) values for the orthodontic wires were obtained. RESULTS: With regard to the cortical bone and PDL, the highest σmin and σmax values for FTM, FN, and FA were checked. With regard to the alveolar bone, σmax and σmin values were highest for FA, followed by FTM and FN. The σvM values of the orthodontic wires followed the order of rigidity of the alloys, that is, FA > FTM > FN. CONCLUSION: The biomechanical behavior of the analyzed structures with regard to all the three patterns of flexibility was similar.


Assuntos
Análise do Estresse Dentário , Análise de Elementos Finitos , Imageamento Tridimensional , Fios Ortodônticos , Traumatismos Dentários/terapia , Reimplante Dentário/métodos , Ligas , Fenômenos Biomecânicos , Resinas Compostas , Simulação por Computador , Módulo de Elasticidade , Humanos , Maxila , Modelos Dentários , Molibdênio , Aço , Titânio , Tomografia Computadorizada por Raios X , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...