Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
AJNR Am J Neuroradiol ; 44(8): 922-927, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37414451

RESUMO

BACKGROUND: Perfusion imaging with multidetector CT is integral to the evaluation of patients presenting with ischemic stroke due to large-vessel occlusion. Using conebeam CT perfusion in a direct-to-angio approach could reduce workflow times and improve functional outcome. PURPOSE: Our aim was to provide an overview of conebeam CT techniques for quantifying cerebral perfusion, their clinical applications, and validation. DATA SOURCES: A systematic search was performed for articles published between January 2000 and October 2022 in which a conebeam CT imaging technique for quantifying cerebral perfusion in human subjects was compared against a reference technique. STUDY SELECTION: Eleven articles were retrieved describing 2 techniques: dual-phase (n = 6) and multiphase (n = 5) conebeam CTP. DATA ANALYSIS: Descriptions of the conebeam CT techniques and the correlations between them and the reference techniques were retrieved. DATA SYNTHESIS: Appraisal of the quality and risk of bias of the included studies revealed little concern about bias and applicability. Good correlations were reported for dual-phase conebeam CTP; however, the comprehensiveness of its parameter is unclear. Multiphase conebeam CTP demonstrated the potential for clinical implementation due to its ability to produce conventional stroke protocols. However, it did not consistently correlate with the reference techniques. LIMITATIONS: The heterogeneity within the available literature made it impossible to apply meta-analysis to the data. CONCLUSIONS: The reviewed techniques show promise for clinical use. Beyond evaluating their diagnostic accuracy, future studies should address the practical challenges associated with implementing these techniques and the potential benefits for different ischemic diseases.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Isquemia Encefálica/complicações , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Imagem de Perfusão/métodos , Acidente Vascular Cerebral/complicações , Tomografia Computadorizada por Raios X/métodos
2.
Sci Rep ; 11(1): 18294, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34521962

RESUMO

The assessment of gaps and steps in acetabular fractures is challenging. Data from various imaging techniques to enable accurate quantification of acetabular fracture displacement are limited. The aim of this study was to assess the accuracy of pelvic radiographs, intraoperative fluoroscopy, and computed tomography (CT) in detecting gaps and step-offs in acetabular fractures. Sixty patients, surgically treated for acetabular fractures, were included. Five observers (5400 measurements) measured the gaps and step-offs on radiographs and CT scans. Intraoperative fluoroscopy images were reassessed for the presence of gaps and/or step-offs. Preoperatively, 25% of the gaps and 40% of the step-offs were undetected on radiographs compared to CT. Postoperatively, 52% of the gaps and 80% of the step-offs were missed on radiographs compared to CT. Radiograph analysis led to a significantly smaller gap and step-off compared to the CT measurements, an underestimation by a factor of two. Approximately 70% of the residual gaps and step-offs was not detected using intraoperative fluoroscopy. Gaps and step-offs that exceed the critical cut-off indicating worse prognosis often remained undetected on radiographs compared to CT scans. Less-experienced observers tend to overestimate gaps and step-offs compared to the more-experienced observers. In acetabular fracture treatment, gaps and step-offs were often undetected and underestimated on radiographs and intraoperative fluoroscopy in comparison with CT scans. This means that CT is superior to radiographs in detecting acetabular fracture displacement, which is clinically relevant for patient counselling regarding treatment decisions and prognosis.


Assuntos
Acetábulo/lesões , Fraturas Ósseas/diagnóstico por imagem , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/cirurgia , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Redução Aberta/métodos , Radiografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
3.
J Biomech Eng ; 142(1)2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31513713

RESUMO

Two-dimensional (2D) or three-dimensional (3D) models of blood flow in stenosed arteries can be used to patient-specifically predict outcome metrics, thereby supporting the physicians in decision making processes. However, these models are time consuming which limits the feasibility of output uncertainty quantification (UQ). Accurate surrogates (metamodels) might be the solution. In this study, we aim to demonstrate the feasibility of a generalized polynomial chaos expansion-based metamodel to predict a clinically relevant output metric and to quantify the output uncertainty. As an example, a metamodel was constructed from a recently developed 2D model that was shown to be able to estimate translesional pressure drops in iliac artery stenoses (-0.9 ± 12.7 mmHg, R2 = 0.81). The metamodel was constructed from a virtual database using the adaptive generalized polynomial chaos expansion (agPCE) method. The constructed metamodel was then applied to 25 stenosed iliac arteries to predict the patient-specific pressure drop and to perform UQ. Comparing predicted pressure drops of the metamodel and in vivo measured pressure drops, the mean bias (-0.2 ± 13.7 mmHg) and the coefficient of determination (R2 = 0.80) were as good as of the original 2D computational fluid dynamics (CFD) model. UQ results of the 2D and metamodel were comparable. Estimation of the uncertainty interval using the original 2D model took 14 days, whereas the result of the metamodel was instantly available. In conclusion, it is feasible to quantify the uncertainty of the output metric and perform sensitivity analysis (SA) instantly using a metamodel. Future studies should investigate the possibility to construct a metamodel of more complex problems.


Assuntos
Artéria Ilíaca , Incerteza , Algoritmos , Constrição Patológica , Humanos , Modelos Cardiovasculares
4.
Sci Rep ; 9(1): 14395, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31591466

RESUMO

Fracture gap and step-off measurements on 2DCT-slices probably underestimate the complex multi-directional features of tibial plateau fractures. Our aim was to develop a quantitative 3D-CT (Q3DCT) fracture analysis of these injuries. CT-based 3D models were created for 10 patients with a tibial plateau fracture. Several 3D measures (gap area, articular surface involvement, 3D displacement) were developed and tested. Gaps and step-offs were measured in 2D and 3D. All measurements were repeated by six observers and the reproducibility was determined by intra-class correlation coefficients. Q3DCT measurements demonstrated a median gap of 5.3 mm, step-off of 5.2 mm, gap area of 235 mm2, articular surface involvement of 33% and 3D displacement of 6.1 mm. The inter-rater reliability was higher in the Q3DCT than in the 2DCT measurements for both the gap (0.96 vs. 0.81) and step-off (0.63 vs. 0.32). Q3DCT measurements showed excellent reliability (ICC of 0.94 for gap area, 1 for articular surface involvement and 0.99 for 3D displacement). Q3DCT fracture analysis of tibial plateau fractures is feasible and shows excellent reliability. 3D measurements could be used together with the current classification systems to quantify the true extent of these complex multi-directional fractures in a standardized way.


Assuntos
Imageamento Tridimensional , Fraturas da Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
5.
J Biomech ; 92: 67-75, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31202523

RESUMO

The aim of this study was to develop and verify a model that provides an accurate estimation of the trans-lesion hyperemic pressure gradient in iliac artery stenoses in seconds by only using patient-specific geometric properties obtained from 3-dimensional rotational angiography (3DRA). Twenty-one patients with symptomatic peripheral arterial disease (PAD), iliac artery stenoses and an ultrasound based peak systolic velocity ratio between 2.5 and 5.0 underwent 3DRA and intra-arterial pressure measurements under hyperemic conditions. For each lesion, geometric properties were extracted from the 3DRA images using quantitative vascular analysis software. Hyperemic blood flow was estimated based on stenosis geometry using an empirical relation. The geometrical properties and hyperemic flow were used to estimate the pressure gradient by means of the geometry-based model. The predicted pressure gradients were compared with in vivo measured intra-arterial pressure measurements performed under hyperemic conditions. The developed geometry-based model showed good agreement with the measured hyperemic pressure gradients resulting in a concordance correlation coefficient of 0.86. The mean bias ±â€¯2SD between the geometry-based model and in vivo measurements was comparable to results found by evaluating the actual computational fluid dynamics model (-1.0 ±â€¯14.7 mmHg vs -0.9 ±â€¯12.7 mmHg). The developed model estimates the trans-lesional pressure gradient in seconds without the need for an additional computational fluid dynamics software package. The results justify further study to assess the potential use of a geometry-based model approach to estimate pressure gradient on non-invasive CTA or MRA, thereby reducing the need for diagnostic angiography in patients suffering from PAD.


Assuntos
Pressão Sanguínea , Artéria Ilíaca/fisiopatologia , Modelos Biológicos , Angiografia , Velocidade do Fluxo Sanguíneo , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Sístole
6.
PLoS One ; 14(6): e0218612, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31216346

RESUMO

INTRODUCTION: Acetabular fractures consist of complex fracture patterns whereby bone fragments are displaced in different directions. Two-dimensional computed tomography (2DCT) gap and step-off measurements tend to underestimate the multidirectional features of these fractures. The aim was to develop a three-dimensional computed tomography (3DCT) measurement method for acetabular fractures and validate whether this method will provide an observer independent fracture characterization. MATERIALS AND METHODS: Sixty patients, operated for an acetabular fracture between 2007 and 2018, were included. The displacement was measured on the pre- and postoperative CT scans. Pre- and postoperative CT-based 3D models were made for each patient. Multiple 3D measurements, namely the 3D step-off, gap and the total gap area were introduced to quantify the preoperative and postoperative displacement. The Wilcoxon signed rank analysis was used to compare the 2DCT and 3DCT measurements. RESULTS: The preoperative displacement was significantly underestimated by 2DCT measurements in comparison with 3DCT measurements (2D vs. 3D; step-off 8 vs. 16 mm with P < 0.001; gap 19 vs. 21 mm with P = 0.001). The same applies to the postoperative residual displacement (2D vs. 3D; step-off 0 vs. 6 mm; gap 3 vs. 8 mm; P < 0.001). The total gap area, defined as the surface area between all fracture lines in the 3D model, was measured for each patient, resulting in a median value of 722 mm2 preoperatively and 168 mm2 postoperatively, with excellent inter- and intra-rater reliability. CONCLUSION: 2DCT measurements tend to underestimate the initial and residual displacement in complex acetabular fractures. A 3DCT analysis of these injuries was developed to overcome this and should be used in addition to the Judet/Letournel and AO/OTA classification systems, in order to provide an observer independent quantifiable fracture description and accurate assessment of the fracture reduction.


Assuntos
Acetábulo/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Modelagem Computacional Específica para o Paciente , Tomografia Computadorizada por Raios X/métodos , Acetábulo/lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Expert Rev Med Devices ; 14(8): 651-656, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28678569

RESUMO

INTRODUCTION: Despite improvements in endograft design, operator skills, and patient selection, late endovascular abdominal aortic aneurysm repair (EVAR) associated complications and need for reinterventions remains the Achilles heel. These complications erode the early benefit over open aneurysm repair during long-term follow-up. The recently introduced endovascular aneurysm sealing (EVAS) is an innovative technology with the intention to lower these EVAR related complications. Areas covered: In this review the EVAS technique, indications, and possible applications, will be discussed, as well as a critical appraisal of clinical outcomes. Expertcommentary: EVAS is a promising technique for treating abdominal aortic aneurysms, and early efficacy data are encouraging in very suitable straight forward anatomy. The Nellix device is still in development. Longterm results are awaited.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/instrumentação , Complicações Pós-Operatórias , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Seleção de Pacientes , Resultado do Tratamento
8.
Br J Surg ; 104(11): 1477-1485, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28650577

RESUMO

BACKGROUND: Recent observations have suggested a decline in vulnerable carotid artery and iliofemoral atherosclerotic plaque characteristics over the past decade. The aim of this study was to determine whether, in the presence of clinically manifest carotid or peripheral artery disease, secondary adverse cardiovascular events decreased over this period. METHODS: Patients included in the Athero-Express biobank between 2003 and 2012 were analysed. During 3-year follow-up, composite cardiovascular endpoints were documented yearly, including: myocardial infarction, coronary interventions, stroke, peripheral interventions and cardiovascular death. The major cardiovascular endpoint consisted of myocardial infarction, stroke and cardiovascular death. RESULTS: Some 1684 patients who underwent carotid endarterectomy (CEA) and another 530 who had iliofemoral endarterectomy (IFE) were analysed. In total, 405 (25·2 per cent) and 236 (45·9 per cent) patients had a composite cardiovascular endpoint within 3 years after CEA and IFE respectively. Corrected for possible confounders, the percentage of patients with a secondary cardiovascular event after CEA did not change over time (hazard ratio (HR) 0·91, 95 per cent c.i. 0·65 to 1·28; P = 0·590, for 2011-2012 versus 2003-2004). In patients who had IFE, the incidence of secondary cardiovascular events significantly decreased only in the last 2 years (HR 0·62, 0·41 to 0·94; P = 0·024), owing to a decrease in peripheral (re)interventions in 2011-2012 (HR 0·59, 0·37 to 0·94; P = 0·028). No decrease in major cardiovascular events was observed in either group. CONCLUSION: In patients who had undergone either CEA or IFE there was no evidence of a decrease in all secondary cardiovascular events. There were no differences in major cardiovascular events.


Assuntos
Endarterectomia das Carótidas , Endarterectomia , Artéria Femoral/cirurgia , Artéria Ilíaca/cirurgia , Idoso , Amputação Cirúrgica/estatística & dados numéricos , Ponte de Artéria Coronária , Morte Súbita Cardíaca/epidemiologia , Prescrições de Medicamentos/estatística & dados numéricos , Endarterectomia/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Países Baixos/epidemiologia , Intervenção Coronária Percutânea/estatística & dados numéricos , Placa Aterosclerótica/cirurgia , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia
11.
Eur J Vasc Endovasc Surg ; 53(2): 290-298, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28025005

RESUMO

OBJECTIVE/BACKGROUND: Mechanochemical endovenous ablation (MOCA) has been developed as a tumescentless technique to ablate saphenous veins and to avoid heat induced complications and post-procedural pain. The mechanism of action of MOCA is poorly understood. The present experiments were conducted to determine the effect of MOCA on vein wall injury and sclerosis in an animal model. METHODS: A total of 36 lateral saphenous veins (LSVs) were treated in 18 goats according to the human protocol. Veins from nine goats were evaluated 45 min after the procedure, while in the remaining nine, the treated veins were evaluated 6 weeks later. All treated veins were divided equally over three treatment groups: (i) MOCA, (ii) mechanical ablation without the sclerosant, and (iii) liquid sclerotherapy alone. The histological effects of treatment on the vein wall were systematically evaluated. RESULTS: The average diameter of the LSV was 4.0 ± 0.5 mm. Technical success was achieved in all but one LSV (35/36; 97%), with a median procedure time of 14 min (range 9-22 min). In the acute group, histological examination showed that mechanical ablation (alone or MOCA) induced severe injury to the endothelium in 82% but no damage to other layers of the vein wall. Mechanical ablation led to vasoconstriction. After 6 weeks follow-up, four of six MOCA treated veins were occluded. The occluded segments consisted mainly of fibrotic lesions probably evolved from organised thrombus. No occlusions were observed after sclerotherapy or mechanical treatment alone. No major complications occurred during procedures or follow-up. CONCLUSION: MOCA is associated with an increased occlusion rate compared with its separated components of mechanical ablation or sclerotherapy. The occlusion consists of cellular fibrotic material likely to be evolved from organised thrombus with fibrotic alterations to the surrounding media and adventitia. This study underlines the hypothesis that the additive use of MOCA increases the effectiveness of sclerosants alone by inducing endothelial damage and probably vasoconstriction.


Assuntos
Técnicas de Ablação/instrumentação , Procedimentos Endovasculares/instrumentação , Veia Safena/cirurgia , Soluções Esclerosantes/administração & dosagem , Técnicas de Ablação/efeitos adversos , Animais , Endotélio Vascular/patologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Fibrose , Cabras , Hiperplasia , Modelos Animais , Músculo Liso Vascular/patologia , Veia Safena/patologia , Veia Safena/fisiopatologia , Soluções Esclerosantes/efeitos adversos , Escleroterapia/efeitos adversos , Fatores de Tempo , Vasoconstrição
12.
Eur J Vasc Endovasc Surg ; 53(3): 387-402, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28027892

RESUMO

BACKGROUND: Critical limb ischaemia (CLI) is the end stage of peripheral artery disease (PAD) and is associated with high amputation and mortality rates and poor quality of life. For CLI patients with no revascularisation options, venous arterialisation could be a last resort for limb salvage. OBJECTIVE: To review the literature on the clinical effectiveness of venous arterialisation for lower limb salvage in CLI patients with no revascularisation options. METHOD: Different databases were searched for papers published between January 1966 and January 2016. The criteria for eligible articles were studies describing outcomes of venous arterialisation, published in English, human studies, and with the full text available. Additionally, studies were excluded if they did not report limb salvage, wound healing or amputation as outcome measures. The primary outcome measure was post-operative limb salvage at 12 months. Secondary outcome measures were 30 day or in-hospital mortality, survival, patency, technical success, and wound healing. RESULTS: Fifteen articles met the inclusion criteria. The included studies described 768 patients. According to the MINORS score, methodological quality was moderate to poor. The estimated pooled limb salvage rate at one year was 75% (0.75, 95% CI 0.70-0.81). Thirty day or in-hospital mortality was reported in 12 studies and ranged from 0 to 10%. Overall survival was reported in 10 studies and ranged from 54% to 100% with a mean follow-up ranging from 5 to 60 months. Six studies reported on patency of the venous arterialisations performed, with a range of 59-71% at 12 months. CONCLUSION: In this systematic review on venous arterialisation in patients with non-reconstructable critical limb ischaemia, the pooled proportion of limb salvage at 12 months was 75%. Venous arterialisation could be a valuable treatment option in patients facing amputation of the affected limb; however, the current evidence is of low quality.


Assuntos
Isquemia/cirurgia , Salvamento de Membro , Extremidade Inferior/irrigação sanguínea , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Estado Terminal , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/mortalidade , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade , Cicatrização
13.
Vision Res ; 129: 87-97, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27664350

RESUMO

Saccade latencies are known to increase for targets presented close to fixation. Recently, it was shown that not only target eccentricity, but the size of a proximal saccade target also plays a crucial role: latencies increase rapidly with increasing target size. Interestingly, these latency increases are greater than those typically found for other supra-threshold manipulations of target properties. Here we evaluate to what extent this phenomenon is distinct from known delays in saccade initiation and whether the phenomenon is truly related to the size of a proximal target. In Experiment 1 we focus on the importance of the required amplitude. Employing a saccade adaptation paradigm we find that the required amplitude is not a determining factor. Focusing on the role of size, in Experiment 2, we find that while latency increases are strongest for targets elongated in the direction of the fovea, elongations perpendicular to this direction also lead to an increase in latencies. Finally, in Experiment 3 we verify that the latency increases are driven by the properties of the saccade target rather than visual input in general. Together these experiments provide converging evidence that the current phenomenon is both novel and a consequence of the relation between proximal target size and its eccentricity.


Assuntos
Adaptação Ocular/fisiologia , Tempo de Reação/fisiologia , Movimentos Sacádicos/fisiologia , Percepção de Tamanho/fisiologia , Adulto , Feminino , Fixação Ocular , Humanos , Masculino , Estimulação Luminosa , Adulto Jovem
14.
Eur J Vasc Endovasc Surg ; 52(5): 650-656, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27614555

RESUMO

OBJECTIVE: Near-infrared spectroscopy (NIRS) non-invasively determines tissue oxygen saturation (Sto2) in muscle tissue. Its application to monitor real time hemodynamic changes during percutaneous transluminal angioplasty (PTA) and Sto2 changes in feet 4 weeks after PTA was evaluated. METHODS: This study included 14 patients with critical limb ischemia (CLI, six patients Rutherford classification Stage IV, two patients Stage V, and six patients Stage VI). In patients with arterial ulcers, NIRS optodes were placed near the ulcer of the diseased foot (Optode 1), and at the same spot at the contralateral foot (Optode 2). In patients without arterial ulcers, Optode 1 was placed on the dorsum of the diseased foot, and Optode 2 was placed on the dorsum of the contralateral foot. Single Sto2 values, ankle brachial indices, and toe brachial indices were obtained at rest before the start of endovascular revascularization and 4 weeks after treatment. During the endovascular procedure, continuous Sto2 measurements were recorded throughout the intervention. Completion angiograms were used to evaluate the success of intervention. RESULTS: Patients underwent treatment of the superficial femoral artery (79%), popliteal artery (21%), and below the knee arteries (43%). In 13 of the 14 patients, completion angiograms showed successful treatment of target lesions. Ankle brachial indices and toe brachial indices significantly increased 4 weeks after treatment (both p < .01). Single Sto2 values of Optode 1 also significantly increased four weeks after treatment (p < .01). In contrast, single Sto2 values of Optode 2 did not (p = .73). During the endovascular procedure, continuous Sto2 measurements of Optode 1 and 2 did not increase (p = .80, and p = .61, respectively). CONCLUSIONS: NIRS monitoring of foot oxygenation in patients undergoing endovascular revascularization is safe and feasible. NIRS is a promising non-invasive technique to monitor hemodynamic changes in the feet of CLI patients after endovascular treatment using single Sto2 values.


Assuntos
Angioplastia com Balão , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Pé/irrigação sanguínea , Isquemia/terapia , Oxigênio/sangue , Doença Arterial Periférica/terapia , Espectroscopia de Luz Próxima ao Infravermelho , Idoso , Idoso de 80 Anos ou mais , Índice Tornozelo-Braço , Biomarcadores/sangue , Estado Terminal , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Isquemia/sangue , Isquemia/diagnóstico , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/sangue , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Projetos Piloto , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
16.
Vascular ; 24(2): 200-2, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26250570

RESUMO

More challenging abdominal aortic aneurysms with unfavorable proximal aortic neck anatomy are treated with endovascular means. As a consequence, proximal inadequate sealing may result in type IA endoleak, which in turn can lead to abdominal aortic aneurysm progression or rupture. The presence of type IA endoleak is an indication for secondary interventions. External aortic banding can be a good option to solve a type IA endoleak, but is underreported in literature; we present two cases and review literature.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Feminino , Humanos , Ligadura , Reoperação , Resultado do Tratamento
17.
Eur J Vasc Endovasc Surg ; 51(1): 56-62, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26437914

RESUMO

OBJECTIVE: Endovascular aortic sealing (EVAS) with the Nellix endosystem (Endologix, Irvine, CA, USA) is a new concept to treat infrarenal abdominal aortic aneurysms (AAAs). By sealing the aneurysm, potential endoleaks may be avoided. Early results of EVAS are good, but no data have been published regarding peri-procedural changes in aortoiliac anatomy. In this study, 27 consecutive patients who underwent elective EVAS repair of an AAA were reviewed. METHOD: Specific AAA (diameter, length from renal arteries to aortic bifurcation, supra- and infrarenal neck angulation, AAA volume, thrombus volume, and flow lumen volume), and iliac artery characteristics (length, angulation, location of most severe angulation with reference to the origin of the common iliac artery) were determined from pre- and post-procedural reconstructed computed tomography angiograms. RESULTS: No type I or II endoleaks were seen at 30 day follow up. Total AAA volume, suprarenal and infrarenal angulation, as well as aortic neck diameter did not change significantly post-EVAS. AAA flow lumen increased significantly (mean difference -4.4 mL, 95% CI 2.0 to -8.6 mL) and AAA thrombus volume decreased (mean difference 3.2 mL, 95% CI 2.0 to -1.1 mL). AAA length (125.7 mm vs. 123.1 mm), left common iliac artery length (57.6 mm vs. 55.3 mm), and right and left maximum iliac artery angulation (right 37.4° vs. 32.2°; left: 43.9° vs. 38.4°) were reduced significantly and the location of maximum angulation was further from the iliac artery origin post-EVAS, suggesting slight straightening of the aortoiliac anatomy. CONCLUSION: Most aortoiliac anatomic characteristics remained unchanged post-EVAS. Filling of the endobags to a pressure of 180 mmHg may lead to lost thrombus volume in some patients, probably because liquid is squeezed into lumbar or the inferior mesenteric artery. The absolute differences in pre- and post-EVAS aortoiliac lengths were small, so pre-operative sizing is accurate for determining stent length.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca/cirurgia , Stents , Idoso , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico , Aortografia/métodos , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino , Desenho de Prótese , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Eur J Vasc Endovasc Surg ; 51(2): 216-24, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26522126

RESUMO

OBJECTIVE: Supra- and infrarenal aortic neck angulation have been associated with complications after endovascular aortic aneurysm repair. However, a uniform angulation measurement method is lacking and the concept of angulation suggests a triangular oversimplification of the aortic anatomy. (Semi-)automated calculation of curvature along the center luminal line describes the actual trajectory of the aorta. This study proposes a methodology for calculating aortic (neck) curvature and suggests an additional method based on available tools in current workstations: curvature by digital calipers (CDC). METHODS: Proprietary custom software was developed for automatic calculation of the severity and location of the largest supra- and infrarenal curvature over the center luminal line. Twenty-four patients with severe supra- or infrarenal angulations (≥45°) and 11 patients with small to moderate angulations (<45°) were included. Both CDC and angulation were measured by two independent observers on the pre- and postoperative computed tomographic angiography scans. The relationships between actual curvature and CDC and angulation were visualized and tested with Pearson's correlation coefficient. The CDC was also fully automatically calculated with proprietary custom software. The difference between manual and automatic determination of CDC was tested with a paired Student t test. A p-value was considered significant when two-tailed α < .05. RESULTS: The correlation between actual curvature and manual CDC is strong (.586-.962) and even stronger for automatic CDC (.865-.961). The correlation between actual curvature and angulation is much lower (.410-.737). Flow direction angulation values overestimate CDC measurements by 60%, with larger variance. No significant difference was found in automatically calculated CDC values and manually measured CDC values. CONCLUSION: Curvature calculation of the aortic neck improves determination of the true aortic trajectory. Automatic calculation of the actual curvature is preferable, but measurement or calculation of the curvature by digital calipers is a valid alternative if actual curvature is not at hand.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Artéria Ilíaca/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Automação , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Artéria Ilíaca/cirurgia , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Software , Stents , Resultado do Tratamento
19.
J Vis ; 15(15): 17, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26605846

RESUMO

Many studies have found a strong coupling between selective attention and eye movements. The premotor theory of attention suggests that saccade preparation is directly responsible for such attentional shifts. While it has already been shown that the attentional shift is not directly coupled to the final stages of motor execution, it is currently unknown to what aspect of the earlier stages of saccade preparation the attentional shift is coupled. An important step in this preparation process is resolving the landing point when multiple elements compete for the saccade. Here we ask how such a competition influences the presaccadic attentional locus and whether the presaccadic shift of attention is coupled to the saccade landing position or the possible saccade goals. To this end, we adopt a global effect paradigm where a target is accompanied by a salient distractor resulting in the majority of eye movements landing in between target and distractor. To determine the allocation of attention, participants are presented with a discrimination task shortly before the execution of the saccade. Despite a strong global effect obtained for saccade endpoints, we find little evidence for attentional facilitation at the location between target and distractor, but strong attentional facilitation at the location of the target and distractor. We argue that attention is coupled to active oculomotor programs, but not part of the resolution of these programs towards the execution of the saccade.


Assuntos
Atenção , Movimentos Sacádicos/fisiologia , Adulto , Movimentos Oculares , Feminino , Humanos , Masculino , Adulto Jovem
20.
Atherosclerosis ; 242(1): 351-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26253794

RESUMO

INTRODUCTION: Although plasma lipid levels are known to influence the risk of cardiovascular disease (CVD), little is known about their effect on atherosclerotic plaque composition. To date, large-scale genome-wide association studies have identified 157 common single-nucleotide polymorphisms (SNPs) that influence plasma lipid levels, providing a powerful tool to investigate the effect of plasma lipid levels on atherosclerotic plaque composition. METHODS: In this study, we included 1443 carotid endarterectomy patients from the Athero-Express Biobank Study with genotype data. Plasma concentrations of high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), total cholesterol (TC) and triglycerides (TG) were determined at the time of endarterectomy. Atherosclerotic plaques, obtained during surgery, were histologically examined. For all patients, we calculated weighted genetic burden scores (GBS) for all lipid traits on the basis of the available genotype data. Plasma lipid levels and GBS were tested for association with 7 histological features using linear and logistic regression models. RESULTS: All GBS were associated with their respective plasma lipid concentrations (pHDL-C = 2.4 × 10(-14), pLDL-C = 0.003, pTC = 2.1 × 10(-6), pTG = 3.4 × 10(-8)). Neither the measured plasma lipids, nor the GBS, were associated with histological features of atherosclerotic plaque composition. In addition, neither the plasma lipids nor the GBS were associated with clinical endpoints within 3 years of follow-up, with the notable exception of a negative association between HDL-C and composite cardiovascular endpoints. CONCLUSION: This study found no evidence that plasma lipid levels or their genetic determinants influence carotid plaque composition.


Assuntos
Artérias Carótidas/patologia , Doenças das Artérias Carótidas/genética , Lipídeos/sangue , Polimorfismo de Nucleotídeo Único , Idoso , Bancos de Espécimes Biológicos , Biomarcadores/sangue , Artérias Carótidas/metabolismo , Artérias Carótidas/cirurgia , Doenças das Artérias Carótidas/sangue , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/cirurgia , Endarterectomia das Carótidas , Feminino , Estudos de Associação Genética , Marcadores Genéticos , Predisposição Genética para Doença , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Fenótipo , Placa Aterosclerótica , Medição de Risco , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...