Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Clin Anesth ; 78: 110666, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35124347

RESUMO

STUDY OBJECTIVE: The three-dimensional shape of the ultrasound beam produces a thicker scan plane than most users assume. Viewed longitudinally, a needle placed lateral to a vessel just outside the central scanning plane can be displayed incorrectly in the ultrasound image as if placed intravascularly. This phenomenon is called the beam width artefact, also known as the elevation or slice thickness artefact. The goal of this study was to demonstrate the potential negative effect of the beam width artefact on the performance of in-plane ultrasound-guided vascular access procedures, and to provide a solution. DESIGN: Randomized, double-blinded study SETTING: Department of anaesthesiology and intensive care of a teaching hospital PARTICIPANTS: 31 experienced (anesthesiologists and intensivists) and 36 inexperienced (anesthetic nurses) ultrasound users INTERVENTIONS: We developed an acoustic lens that narrows the scan plane to reduce the beam width artefact. The lens was tested in a simulated vascular access study. MEASUREMENTS: The primary endpoint was first pass success. Secondary endpoints were the number of punctures and needle withdrawals, procedure time, needle visibility and operator satisfaction. MAIN RESULTS: First pass success was highly enhanced using the acoustic lens, with a success rate of 92.5% versus 68.7% without the lens (difference 23.8, 95% confidence interval 11.0-35.3, p < 0.001). The total number of punctures needed to obtain intravenous access was also reduced using the lens (1.10 versus 1.38, difference 0.27, 95% CI 0.11-0.43, p = 0.002). Procedure time, needle withdrawals, needle visibility and satisfaction were similar. Both inexperienced and experienced users benefited from the acoustic lens. CONCLUSIONS: The beam width artefact has a significant effect on the performance of ultrasound-guided needle-based procedures. The efficacy of in-plane superficial vascular access procedures can be enhanced by narrowing the imaging plane using an acoustic lens.


Assuntos
Artefatos , Ultrassonografia de Intervenção , Acústica , Humanos , Punções , Ultrassonografia/métodos , Ultrassonografia de Intervenção/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-19686964

RESUMO

Thin-film ferroelectric capacitors have been integrated with resistors and active functions such as ESD protection into small, miniaturized modules, which enable a board space saving of up to 80%. With the optimum materials and processes, integrated capacitors with capacitance densities of up to 100 nF/mm2 for stacked capacitors combined with breakdown voltages of 90 V have been achieved. The integration of these high-density capacitors with extremely high breakdown voltage is a major accomplishment in the world of passive components and has not yet been reported for any other passive integration technology. Furthermore, thin-film tunable capacitors based on barium strontium titanate with high tuning range and high quality factor at 1 GHz have been demonstrated. Finally, piezoelectric thin films for piezoelectric switches with high switching speed have been realized.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...