1.
Heart Rhythm ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38969049

RESUMO

BACKGROUND: After a cryptogenic stroke, patients will often require prolonged cardiac monitoring; however, the subset of patients who would benefit from long-term rhythm monitoring is not clearly defined. OBJECTIVE: Using significant predictors of AF using age, sex, comorbidities, baseline 12-lead electrocardiogram, short term rhythm monitoring and echocardiogram data, we created a risk score and compared it to previously published risk scores. METHODS: Patients admitted to Montefiore Medical Center between May 2017 and June 2022 with a primary diagnosis of cryptogenic stroke or TIA who underwent long-term rhythm monitoring with an implantable cardiac monitor were retrospectively analyzed. RESULTS: Variables positively associated with a diagnosis of clinically significant atrial fibrillation include age (p < 0.001), race (p = 0.022), diabetes status (p = 0.026), and COPD status (p = 0.012), the presence of atrial runs (p = 0.003), the number of atrial runs per 24 hours (p < 0.001), the total number of atrial run beats per 24 hours (p < 0.001) and the number of beats in the longest atrial run (p < 0.001), LA enlargement (p = 0.007) and at least mild mitral regurgitation (p = 0.009). We created a risk stratification score for our population, termed the "ACL score." The ACL score demonstrated superiority to the CHA2DS2-VASc score and comparability to the C2HEST score for predicting device-detected AF. CONCLUSION: The ACL score enables clinicians to better predict which patients are more likely to be diagnosed with device-detected AF after a cryptogenic stroke.

2.
Int J Cardiol ; : 132333, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972492

RESUMO

OBJECTIVE: Pregnancy can trigger maternal tachycardias, and the onset of recurrent or incessant focal atrial tachycardia (AT) can lead to tachycardia-induced cardiomyopathy. Medical interventions are commonly employed, but they carry potential fetal and maternal risks. Catheter ablation (CA), particularly with non-fluoroscopic navigation systems, may be considered as an alternative. This systematic review aims to explore the feasibility and outcomes of CA for focal AT during pregnancy. METHODS: A thorough literature search was conducted until September 30th, 2023, on PubMed, Embase, and Cochrane databases. Included articles described maternal focal ATs diagnosed through electrophysiological studies and treated with CA. Data derived from these studies were organized into tables and subsequently analyzed. RESULTS: Out of 278 papers reviewed, 15 articles involving 24 patients were retrieved. CA, utilizing radiofrequency energy achieved acute success in 95.8% of cases. Sixteen patients (66.7%) underwent complete fluoroless procedures, with two adverse events directly related to the procedure reported. Long-term follow-up revealed minimal AT recurrences, with a 0.06% arrhythmia burden in one case. CONCLUSION: Focal ATs during pregnancy can be incessant and refractory to medical intervention, precipitating an acute decline in left ventricular ejection fraction. In this setting, CA emerges as an efficacious treatment modality, particularly in cases of tachycardia-induced cardiomyopathies. Whenever feasible, it is advisable to perform these procedures with minimal or no fluoroscopy guidance. Larger studies are needed to establish the safety and the efficacy of CA for focal ATs during pregnancy, as current research consists of case reports or small case series.

3.
Heart Rhythm ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942104

RESUMO

The complexity of cardiac electrophysiology procedures has increased significantly over the past three decades. Anesthesia requirements of these procedures can be different based on patient- and procedure-specific factors. This manuscript outlines various anesthesia strategies for cardiac implantable electronic devices and electrophysiology procedures including pre-procedural, procedural and post-procedural management. A team-based approach with collaboration between cardiac electrophysiologists and anesthesiologists is required with careful pre-procedural and intra-procedural planning. Given the recent advances in electrophysiology, there is a need for specialized cardiac electrophysiology anesthesia care to improve the efficacy and safety of the procedures.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38878012

RESUMO

BACKGROUND: Purkinje fibers play an important role in initiation and maintenance of ventricular fibrillation (VF) and polymorphic ventricular tachycardia (PMVT). Fascicular substrate modification (FSM) approaches have been suggested to treat recurrent VF in case reports and small case series. OBJECTIVES: The aim of this study was to investigate outcomes of catheter-based FSM to treat VF and PMVT. METHODS: Of 2,212 consecutive patients with ventricular arrhythmia undergoing catheter ablation, 18 (0.81%) underwent FSM of the Purkinje fibers as identified with high-density mapping during sinus rhythm. Fascicular substrate and VF initiation were mapped using a multipolar catheter. The endpoint of the ablation was noninducibility of VF and PMVT. In select patients, remapping revealed elimination of the targeted Purkinje potentials. Demographic, clinical, and follow-up characteristics were prospectively collected in our institutional database. RESULTS: A total of 18 patients (mean age 56 ± 3.8 years, 22% women) were included in the study. Of those, 11 (61.1%) had idiopathic VF, 3 (16.7%) had nonischemic cardiomyopathy, and 4 (22.2%) had mixed cardiomyopathy. The average left ventricular ejection fraction was 42.5%. At least 2 antiarrhythmic drugs had failed preablation. At baseline, all patients had inducible VF or PMVT. At the end of the procedure, no patient demonstrated new evidence of fascicular block or bundle branch block. There were no procedure-related complications. After a median follow-up period of 24 months, 16 patients (88.9%) were arrhythmia free on or off drugs: 11 of 11 patients (100%) with idiopathic VF vs 5 of 7 patients (71.4%) with underlying cardiomyopathy (P = 0.06). CONCLUSIONS: Catheter ablation of human VF and PMVT with FSM is feasible and safe and appears highly effective, with high rates of acute VF noninducibility and long-term freedom from recurrent VF.

6.
J Cardiovasc Electrophysiol ; 35(7): 1422-1428, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38751010

RESUMO

INTRODUCTION: Both atrial fibrillation (AF) and amyloidosis increase stroke risk. We evaluated the best anticoagulation strategy in AF patients with coexistent amyloidosis. METHODS: Consecutive AF patients with concomitant amyloidosis were divided into two groups based on the postablation stroke-prophylaxis approach; group 1: left atrial appendage occlusion (LAAO) in eligible patients and group 2: oral anticoagulation (OAC). Group 1 patients were further divided into Gr. 1A: LAAO + half-does NOAC (HD-NOAC) for 6 months followed by aspirin 81 mg/day and Gr. 1B: LAAO + HD-NOAC. In group 1 patients, with complete occlusion at the 45-day transesophageal echocardiogram, patients were switched to aspirin, 81 mg/day at 6 months. In case of leak, or dense "smoke" in the left atrium (LA) or enlarged LA, they were placed on long-term half-dose (HD) NOAC. Group 2 patients remained on full-dose NOAC during the whole study period. RESULTS: A total of 92 patients were included in the analysis; group 1: 56 and group 2: 36. After the 45-day TEE, 31 patients from group 1 remained on baby-aspirin and 25 on HD NOAC. At 1-year follow-up, four stroke, one TIA and six device-thrombus were reported in group 1A, compared to none in patients in group 1B (5/31 vs. 0/25, p = .03). No bleeding events were reported in group 1, whereas group 2 had five bleeding events (one subdural hematoma, one retinal hemorrhage, and four GI bleedings). Additionally, one stroke was reported in group 2 that happened during brief discontinuation of OAC. CONCLUSION: In patients with coexistent AF and amyloidosis, half-dose NOAC following LAAO was observed to be the safest stroke-prophylaxis strategy.


Assuntos
Amiloidose , Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Ablação por Cateter/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Fatores de Risco , Fatores de Tempo , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/diagnóstico por imagem , Hemorragia/induzido quimicamente , Administração Oral , Estudos Retrospectivos , Medição de Risco , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Esquema de Medicação , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico
7.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696701

RESUMO

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Pontuação de Propensão , Sistema de Registros , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Arritmias Cardíacas/terapia , Medição de Risco , Europa (Continente) , Fatores de Tempo , Morte Súbita Cardíaca/prevenção & controle
8.
Card Electrophysiol Clin ; 16(2): 175-180, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749638

RESUMO

The left atrial appendage (LAA) is now recognized as a significant contributor to arrhythmia and thromboembolism in patients with a history of atrial fibrillation. Thoracoscopic exclusion of the LAA is made possible with the AtriClip device. In this report, we describe the case of a 65-year-old man with history of multiple left atrial ablation procedures and LAA clipping. He developed a microreentrant atrial tachycardia originating from the anterior base of the LAA stump, underwent complete isolation of the LAA, and had subsequent resolution of arrhythmogenic activity from the residual LAA stump.


Assuntos
Apêndice Atrial , Humanos , Apêndice Atrial/cirurgia , Apêndice Atrial/fisiopatologia , Idoso , Masculino , Ablação por Cateter , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/fisiopatologia
12.
Heart Rhythm ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38597857

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.

13.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

14.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
15.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584423

RESUMO

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Fatores de Risco , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Incidência , Insuficiência Cardíaca/complicações , Ásia/epidemiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicações
16.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
17.
Heart Rhythm ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38641221

RESUMO

BACKGROUND: Premature ventricular contraction (PVC) burden is a risk factor for heart failure and cardiovascular death in patients with structural heart disease. Long-term electrocardiographic monitoring can have a significant impact on PVC burden evaluation by further defining PVC distribution patterns. OBJECTIVE: This study aimed to ascertain the optimal duration of electrocardiographic monitoring to characterize PVC burden and to understand clinical characteristics associated with frequent PVCs and nonsustained ventricular tachycardia in a large US cohort. METHODS: Commercial data (iRhythm's Zio patch) from June 2011 to April 2022 were analyzed. Inclusion criteria were age >18 years, PVC burden ≥5%, and wear period ≥13 days. PVC burden cutoffs were determined on the basis of AHA/ACC/HRS guidelines for very frequent PVCs (10,000-20,000 during 24 hours). Patients were assigned to categories by PVC densities: low, <10%; moderate, 10% to <20%; and high, ≥20%. Mean measured error was assessed at baseline and daily until the wear period's end for overall PVC burden and different PVC densities. RESULTS: Analysis of 106,705 patch monitors revealed a study population with mean age of 70.6 ± 14.6 years (33.6% female). PVC burden was higher in male patients and those >65 years of age. PVC burden mean error decreased from 2.9% at 24 hours to 1.3% at 7 days and 0.7% at 10 days. Number of ventricular tachycardia episodes per patient increased with increasing PVC burden (P < .0001). CONCLUSION: Extending ambulatory monitoring beyond 24 hours to 7 days or more improves accuracy of assessing PVC burden. Ventricular tachycardia frequency and duration vary by initial PVC density, highlighting the need for prolonged cardiac monitoring.

18.
Front Cardiovasc Med ; 11: 1343424, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322767

RESUMO

Introduction: Implantable cardiac monitors (ICMs) provide long-term arrhythmia monitoring, but high rates of false detections increase the review burden. The new "SmartECG" algorithm filters false detections. Using large real-world data sets, we aimed to quantify the reduction in workload and any loss in sensitivity from this new algorithm. Methods: Patients with a BioMonitor IIIm and any device indication were included from three clinical projects. All subcutaneous ECGs (sECGs) transmitted via remote monitoring were classified by the algorithm as "true" or "false." We quantified the relative reduction in workload assuming "false" sECGs were ignored. The remote monitoring workload from five hospitals with established remote monitoring routines was evaluated. Loss in sensitivity was estimated by testing a sample of 2000 sECGs against a clinical board of three physicians. Results: Of our population of 368 patients, 42% had an indication for syncope or pre-syncope and 31% for cryptogenic stroke. Within 418.5 patient-years of follow-up, 143,096 remote monitoring transmissions contained 61,517 sECGs. SmartECG filtered 42.8% of all sECGs as "false," reducing the number per patient-year from 147 to 84. In five hospitals, nine trained reviewers inspected on average 105 sECGs per working hour. This results in an annual working time per patient of 83 min without SmartECG, and 48 min with SmartECG. The loss of sensitivity is estimated as 2.6%. In the majority of cases where true arrhythmias were rejected, SmartECG classified the same type of arrhythmia as "true" before or within 3 days of the falsely rejected sECG. Conclusion: SmartECG increases efficiency in long-term arrhythmia monitoring using ICMs. The reduction of workload by SmartECG is meaningful and the risk of missing a relevant arrhythmia due to incorrect filtering by the algorithm is limited.

19.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310489

RESUMO

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Ablação por Cateter , Hemoglobinúria , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/etiologia , Idoso , Hemoglobinúria/etiologia , Hemoglobinúria/prevenção & controle , Creatinina/sangue , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hidratação/métodos
20.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38390748

RESUMO

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Assuntos
Ablação por Cateter , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ventrículos do Coração/cirurgia , Catéteres , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS