Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Phys Med ; 41: 117-123, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28457786

RESUMO

PURPOSE: The aim was to calibrate gamma cameras in the framework of the Italian multicentre study for lesion dosimetry in 223Ra therapy of bone metastases. Equipments of several manufacturers and different models were used. METHODS: Eleven gamma cameras (3/8- and 5/8-inch crystal) were used, acquiring planar static images with double-peak (82 and 154keV, 20% wide) and MEGP collimator. The sensitivity was measured in air, varying source-detector distance and source size. Transmission curves were measured, calculating the parameters used for attenuation/scatter correction with the pseudo-extrapolation number method, and assessing their variations with the source size. RESULTS: Values of the calibration factor (geometric mean of both detector sensitivities) ranged from 41.1 to 113.9cps/MBq. For the smallest source (diameter of 3.5cm), the calibration factor decrease ranged from -30% to -4%, highlighting the importance of partial volume effects according to the equipment involved. The sensitivity variation with the source-detector distance, with respect to the 15cm-value, reached 10% (in absolute value) in the range 5-30cm, but fixing the distance between the two heads, the calibration factor variation with the distance from the midline was within 3.6%. Appreciable variation of the transmission curves with the source size were observed, examining the results obtained with six gamma cameras. CONCLUSION: Assessments of sensitivity and transmission curve variations with source size should be regularly implemented in calibration procedures. The results of this study represent a useful compendium to check the obtained calibrations for dosimetric purposes.


Assuntos
Neoplasias Ósseas/radioterapia , Câmaras gama , Radiometria/normas , Calibragem , Humanos , Itália
2.
Epilepsy Behav ; 68: 51-56, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28109990

RESUMO

Vertigo and dizziness are extremely common complaints, related to either peripheral or central nervous system disorders. Among the latter, epilepsy has to be taken into consideration: indeed, vertigo may be part of the initial aura of a focal epileptic seizure in association with other signs/symptoms, or represent the only ictal manifestation, a rare phenomenon known as "vertiginous" or "vestibular" seizure. These ictal symptoms are usually related to a discharge arising from/involving temporal or parietal areas, which are supposed to be a crucial component of the so-called "vestibular cortex". In this paper, we describe three patients suffering from drug-resistant focal epilepsy, symptomatic of malformations of cortical development or perinatal hypoxic/ischemic lesions located in the posterior regions, who presented clusters of vertiginous seizures. The high recurrence rate of such events, recorded during video-EEG monitoring sessions, offered the opportunity to perform an ictal EEG/fMRI study to identify seizure-related hemodynamic changes. The ictal EEG/fMRI revealed the main activation clusters in the temporo-parieto-occipital regions, which are widely recognized to be involved in the processing of vestibular information. Interestingly, ictal deactivation was also detected in the ipsilateral cerebellar hemisphere, suggesting the ictal involvement of cortical-subcortical structures known to be part of the vestibular integration network.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Eletroencefalografia , Imageamento por Ressonância Magnética , Convulsões/diagnóstico por imagem , Adulto , Córtex Cerebral/fisiopatologia , Feminino , Humanos , Pessoa de Meia-Idade , Convulsões/fisiopatologia
3.
Phys Med ; 33: 47-55, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28003137

RESUMO

PURPOSE: Cardiac magnetic resonance (CMR) is a useful non-invasive tool for characterizing tissues and detecting myocardial fibrosis and edema. Estimation of extracellular volume fraction (ECV) using T1 sequences is emerging as an accurate biomarker in cardiac diseases associated with diffuse fibrosis. In this study, automatic software for T1 and ECV map generation consisting of an executable file was developed and validated using phantom and human data. METHODS: T1 mapping was performed in phantoms and 30 subjects (22 patients and 8 healthy subjects) on a 1.5T MR scanner using the modified Look-Locker inversion-recovery (MOLLI) sequence prototype before and 15 min after contrast agent administration. T1 maps were generated using a Fast Nonlinear Least Squares algorithm. Myocardial ECV maps were generated using both pre- and post-contrast T1 image registration and automatic extraction of blood relaxation rates. RESULTS: Using our software, pre- and post-contrast T1 maps were obtained in phantoms and healthy subjects resulting in a robust and reliable quantification as compared to reference software. Coregistration of pre- and post-contrast images improved the quality of ECV maps. Mean ECV value in healthy subjects was 24.5%±2.5%. CONCLUSIONS: This study demonstrated that it is possible to obtain accurate T1 maps and informative ECV maps using our software. Pixel-wise ECV maps obtained with this automatic software made it possible to visualize and evaluate the extent and severity of ECV alterations.


Assuntos
Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Miocárdio/patologia , Automação , Estudos de Casos e Controles , Espaço Extracelular/metabolismo , Estudos de Viabilidade , Fibrose , Cardiopatias/diagnóstico por imagem , Cardiopatias/patologia , Humanos , Imagens de Fantasmas , Software
4.
J Ther Ultrasound ; 4: 32, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27980785

RESUMO

BACKGROUND: A new transcranial focused ultrasound device has been developed that can induce hyperthermia in a large tissue volume. The purpose of this work is to investigate theoretically how glioblastoma multiforme (GBM) can be effectively treated by combining the fast hyperthermia generated by this focused ultrasound device with external beam radiotherapy. METHODS/DESIGN: To investigate the effect of tumor growth, we have developed a mathematical description of GBM proliferation and diffusion in the context of reaction-diffusion theory. In addition, we have formulated equations describing the impact of radiotherapy and heat on GBM in the reaction-diffusion equation, including tumor regrowth by stem cells. This formulation has been used to predict the effectiveness of the combination treatment for a realistic focused ultrasound heating scenario. Our results show that patient survival could be significantly improved by this combined treatment modality. DISCUSSION: High priority should be given to experiments to validate the therapeutic benefit predicted by our model.

5.
Phys Med ; 32(12): 1731-1737, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27662815

RESUMO

PURPOSE: The aims of this work were to explore patient eligibility criteria for dosimetric studies in 223Ra therapy and evaluate the effects of differences in gamma camera calibration procedures into activity quantification. METHODS: Calibrations with 223Ra were performed with four gamma cameras (3/8-inch crystal) acquiring planar static images with double-peak (82 and 154keV, 20% wide) and MEGP collimator. The sensitivity was measured in air by varying activity, source-detector distance, and source diameter. Transmission curves were measured for attenuation/scatter correction with the pseudo-extrapolation number method, varying the experimental setup. 223Ra images of twenty-five patients (69 lesions) were acquired to study the lesions visibility. Univariate ROC analysis was performed considering visible/non visible lesions on 223Ra images as true positive/true negative group, and using as score value the lesion/soft tissue contrast ratio (CR) derived from 99mTc-MDP WB scan. RESULTS: Sensitivity was nearly constant varying activity and distance (maximum s.d.=2%). Partial volume effects were negligible for object area ⩾960mm2. Transmission curve measurements are affected by experimental setup and source size, leading to activity quantification errors up to 20%. The ROC analysis yielded an AUC of 0.972 and an optimal threshold of CR of 10, corresponding to an accuracy of 92%. CONCLUSION: The minimum calibration protocol requires sensitivity and transmission curve measurements varying the object size, performing a careful procedure standardisation. Lesions with 99mTc-MDP CR higher than 10, not overlapping the GI tract, are generally visible on 223Ra images acquired at 24h after the administration, and possibly eligible for dosimetric studies.


Assuntos
Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/secundário , Câmaras gama , Radiometria/instrumentação , Rádio (Elemento)/uso terapêutico , Calibragem , Humanos , Itália , Seleção de Pacientes , Curva ROC
6.
Ann Ist Super Sanita ; 52(2): 256-60, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27364401

RESUMO

BACKGROUND: High Intensity Focused Ultrasound (HIFU) is a noninvasive treatment for therapeutic applications, in particular the treatment of either benign or malignant tumor lesions. HIFU treatment is based on the power of a focused ultrasound beam to locally heat biological tissues over a necrotic level with minimal impact on the surrounding tissues. Therapies based on HIFU are becoming widely spread in the panorama of options offered by the Health Care System. Consequently, there is an ever increasing need to standardise quality assurance protocols and to develop computational tools to evaluate the output of clinical HIFU devices and ensuring safe delivery of HIFU treatment. AIMS: Goal of this study is the development of a computational tool for HIFU ablation therapy to assure safety of the patient and effectiveness of the treatment. RESULTS: The simulated results provide information about the behaviour of the focalized ultrasound in their interaction with different biological tissues. CONCLUSIONS: Numerical simulation represents a useful approach to predict the heath deposition and, consequently, to assess the safety and effectiveness of HIFU devices.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Algoritmos , Humanos , Neoplasias/terapia , Segurança do Paciente , Software , Resultado do Tratamento
7.
Ann Nucl Med ; 30(2): 163-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26613714

RESUMO

A 70-year-old man affected by bone metastases from castration resistant prostate cancer underwent Alpharadin ((223)Ra-dichloride) therapy (6 administrations of 50 kBq per kg i.v., once every 4 weeks). The inter-fraction variability of the absorbed dose to lesions was evaluated for four injections. Dosimetric assessments were performed following the MIRD approach and a recently published methodology. The mean absorbed dose and standard deviation for 4 lesions [mean (σ %)] were: 434 mGy (15%) and 516 mGy (21%) for the right and left humeral head, 1205 mGy (14%) and 781 mGy (8%) for the right and left glenoid. The estimated total absorbed dose after the whole treatment, considering also the relative-biological effectiveness of alpha particles (RBE = 5), yielded a D RBE range of 13-36 Gy. A good correlation between (99m)Tc and (223)Ra uptake was obtained (R (2) = 0.7613). The tumour-non-tumour (TNT) ratio of 8 lesions (those above, plus 4 additional), monitored by six (99m)Tc-MDP bone scans over a period of about 10 months, evidenced a TNT reduction in two lesions (-42 and -48 %), but in most lesions the TNT remained fairly constant, evidencing that (223)Ra-dichloride therapy tends to prevent further progression of osseous disease, leading to chronicity of the metastatic status.


Assuntos
Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/secundário , Cloretos/uso terapêutico , Fracionamento da Dose de Radiação , Rádio (Elemento)/uso terapêutico , Idoso , Seguimentos , Humanos , Masculino , Neoplasias de Próstata Resistentes à Castração/patologia , Radiometria
8.
Eur J Nucl Med Mol Imaging ; 43(1): 21-33, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26266887

RESUMO

PURPOSE: Ra-dichloride is an alpha-emitting radiopharmaceutical used in the treatment of bone metastases from castration-resistant prostate cancer. Image-based dosimetric studies remain challenging because the emitted photons are few. The aim of this study was to implement a methodology for in-vivo quantitative planar imaging, and to assess the absorbed dose to lesions using the MIRD approach. METHODS: The study included nine Caucasian patients with 24 lesions (6 humeral head lesions, 4 iliac wing lesions, 2 scapular lesions, 5 trochanter lesions, 3 vertebral lesions, 3 glenoid lesions, 1 coxofemoral lesion). The treatment consisted of six injections (one every 4 weeks) of 50 kBq per kg body weight. Gamma-camera calibrations for (223)Ra included measurements of sensitivity and transmission curves. Patients were statically imaged for 30 min, using an MEGP collimator, double-peak acquisition, and filtering to improve the image quality. Lesions were delineated on (99m)Tc-MDP whole-body images, and the ROIs superimposed on the (223)Ra images after image coregistration. The activity was quantified with background, attenuation, and scatter correction. Absorbed doses were assessed deriving the S values from the S factors for soft-tissue spheres of OLINDA/EXM, evaluating the lesion volumes by delineation on the CT images. RESULTS: In 12 lesions with a wash-in phase the biokinetics were assumed to be biexponential, and to be monoexponential in the remainder. The optimal timing for serial acquisitions was between 1 and 5 h, between 18 and 24 h, between 48 and 60 h, and between 7 and 15 days. The error in cumulated activity neglecting the wash-in phase was between 2 % and 12 %. The mean effective half-life (T 1/2eff) of (223)Ra was 8.2 days (range 5.5-11.4 days). The absorbed dose (D) after the first injection was 0.7 Gy (range 0.2-1.9 Gy. Considering the relative biological effectiveness (RBE) of alpha particles (RBE = 5), D RBE = 899 mGy/MBq (range 340-2,450 mGy/MBq). The percent uptake of (99m)Tc and (223)Ra (activity extrapolated to t = 0) were significantly correlated. CONCLUSION: The feasibility of in vivo quantitative imaging in (223)Ra therapy was confirmed. The lesion uptake of (223)Ra-dichloride was significantly correlated with that of (99m)Tc-MDP. The D RBE to lesions per unit administered activity was much higher than that of other bone-seeking radiopharmaceuticals, but considering a standard administration of 21 MBq (six injections of 50 kBq/kg to a 70-kg patient), the mean cumulative value of D RBE was about 19 Gy, and was therefore in the range of those of other radiopharmaceuticals. The macrodosimetry of bone metastases in treatments with (223)Ra-dichloride is feasible, but more work is needed to demonstrate its helpfulness in predicting clinical outcomes.


Assuntos
Partículas alfa/uso terapêutico , Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/secundário , Rádio (Elemento)/uso terapêutico , Adulto , Transporte Biológico , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/metabolismo , Humanos , Cinética , Masculino , Compostos de Organotecnécio/metabolismo , Neoplasias de Próstata Resistentes à Castração/patologia , Radioisótopos/metabolismo , Radioisótopos/uso terapêutico , Radiometria , Rádio (Elemento)/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
9.
Radiat Prot Dosimetry ; 168(4): 509-15, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26211013

RESUMO

This study evaluates X-ray exposure in patient undergoing abdominal extra-vascular interventional procedures by means of Digital Imaging and COmmunications in Medicine (DICOM) image headers and Monte Carlo simulation. The main aim was to assess the effective and equivalent doses, under the hypothesis of their correlation with the dose area product (DAP) measured during each examination. This allows to collect dosimetric information about each patient and to evaluate associated risks without resorting to in vivo dosimetry. The dose calculation was performed in 79 procedures through the Monte Carlo simulator PCXMC (A PC-based Monte Carlo program for calculating patient doses in medical X-ray examinations), by using the real geometrical and dosimetric irradiation conditions, automatically extracted from DICOM headers. The DAP measurements were also validated by using thermoluminescent dosemeters on an anthropomorphic phantom. The expected linear correlation between effective doses and DAP was confirmed with an R(2) of 0.974. Moreover, in order to easily calculate patient doses, conversion coefficients that relate equivalent doses to measurable quantities, such as DAP, were obtained.


Assuntos
Abdome/diagnóstico por imagem , Método de Monte Carlo , Imagens de Fantasmas , Radiologia Intervencionista/métodos , Idoso , Antropometria , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Radiometria/métodos , Raios X
10.
Clin EEG Neurosci ; 47(1): 56-60, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25733678

RESUMO

Epilepsy and attention-deficit/hyperactivity disorder (ADHD) likely share common underlying neural mechanisms, as often suggested by both the evidence of electroencephalography (EEG) abnormalities in ADHD patients without epilepsy and the coexistence of these 2 conditions. The differential diagnosis between epilepsy and ADHD may consequently be challenging. In this report, we describe a patient presenting with a clinical association of "tics" and behavioral disorders that appeared 6 months before our first observation and had previously been interpreted as ADHD. A video-EEG evaluation documented an electroclinical pattern of myoclonic status epilepticus. On the basis of the revised clinical data, the EEG findings, the good response to valproate, the long-lasting myoclonic status epilepticus, and the enduring epileptic abnormalities likely causing behavioral disturbances, the patient's symptoms were interpreted as being the expression of untreated juvenile myoclonic epilepsy. The EEG-functional magnetic resonance imaging study revealed, during clinical generalized spike-and-wave and polyspike-and-wave discharges, positive blood oxygen level-dependent (BOLD) signal changes bilaterally in the thalamus, the prefrontal cortex (Brodmann area 6, supplementary motor area) and the cerebellum, and negative BOLD signal changes in the regions of the default mode network. Such findings, which are typical of BOLD changes observed in idiopathic generalized epilepsy, may also shed light on the anatomofunctional network underlying ADHD.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico , Mapeamento Encefálico/métodos , Eletroencefalografia/métodos , Epilepsias Mioclônicas/diagnóstico , Transtornos Mentais/diagnóstico , Transtornos dos Movimentos/diagnóstico , Criança , Diagnóstico Diferencial , Epilepsias Mioclônicas/complicações , Reações Falso-Negativas , Humanos , Masculino , Transtornos Mentais/etiologia , Transtornos dos Movimentos/etiologia
12.
Med Biol Eng Comput ; 49(3): 373-83, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21052855

RESUMO

A practical and accurate generalized in vivo dosimetry procedure has been implemented for Siemens linacs supplying 6, 10, and 15 MV photon beams, equipped with aSi electronic portal imaging devices (EPIDs). The in vivo dosimetry method makes use of correlation ratios between EPID transit signal, s (t) (0) (TPR,w,L), and phantom mid-plane dose, D (0)(TPR,w,L), as functions of phantom thickness, w, square field dimensions, L, and tissue-phantom ratio TPR(20,10). The s (t) (0) (TPR,w,L) and D (0)(TPR,w,L) values were defined to be independent of the EPID sensitivity and monitor unit calibration, while their dependence on TPR(20,10) was investigated to determine a set of generalized correlation ratios to be used for beams with TPR(20,10) falling in the examined range. This way, other radiotherapy centers can use the method with no need to locally perform the whole set of measurements in solid water phantoms, required to implement it. Tolerance levels for 3D conformal treatments, ranging between ±5 and ±6% according to tumor type and location, were estimated for comparison purposes between reconstructed isocenter dose, D (iso), and treatment planning system (TPS) computed dose D (iso,TPS). Finally a dedicated software, interfaceable with record and verify (R&V) systems used in the centers, was developed to obtain in vivo dosimetry results in less than 2 min after beam delivery.


Assuntos
Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Calibragem , Humanos , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos
13.
J Comput Assist Tomogr ; 32(5): 668-78, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18830094

RESUMO

OBJECTIVE: To evaluate dose reduction and image quality in coronary 64-slice multidetector computed tomography using an automatic exposure control system (AECs). METHODS: A total of 101 patients were divided into 4 groups. Tube current was 600 and 800 mAs in groups A and B and adapted at 600 and 800 quality-reference mAs using an AECs in groups C and D. Effective dose and organ-equivalent dose were evaluated. Image noise was quantified as standard deviation of air-space attenuation. Two observers assessed technical adequacy and image quality using a 4-point scale. RESULTS: Effective dose ranged from 8.6 mSv (group C) to 15 mSv (group B) with significant dose reduction for examinations performed at 600 mAs (21.7%) and 800 mAs (29.4%). Contribution of organ-equivalent doses showed higher exposure for lungs (42%) and breast (22%). Noise was significantly higher in groups studied with AECs. Larger coronary segments resulted in higher image quality scores without differences between groups. CONCLUSION: Automatic exposure control systems provides images of diagnostic quality with substantial dose reduction.


Assuntos
Angiografia Coronária/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...