Appl Radiat Isot ; 163: 109200, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32561041

RESUMO

This study validated a model of the Siemens Symbia T16 dual-head SPECT/CT gamma camera created using the Monte Carlo program SIMIND for 177Lu. The validation was done by comparing experimental and simulated gamma camera performance criteria tests for the 177Lu 208 keV photopeak with a medium-energy collimator. Results showed good agreement between the experimental and simulated values. These results illustrated that SIMIND could emulate the Symbia T16 successfully and therefore, can be used with confidence to model 177Lu images.

2.
Phys Med ; 27(1): 11-20, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20206563

RESUMO

Transmission sources used for image attenuation correction, allowing image quantification, are collimated to reduce scatter. We propose the same effect can be achieved for an uncollimated source by increasing source to patient distance. The aim was to compare planar image performance characteristics and absorbed doses of uncollimated and collimated radioactive printed paper transmission sources. The scatter contribution to the uncollimated (99m)Tc source data was evaluated for different combinations of detector phantom distance, detector source distance and phantom source distance. Measurements were performed by increasing the Lucite phantom thickness in 1cm steps to 20 cm. Spatial resolution, detection efficiency and entrance absorbed dose rate were measured for the uncollimated and collimated transmission source images. Results derived from the energy spectra, obtained with the uncollimated transmission source indicate that scatter contribution increases with decreasing detector source distance. The scatter component in the uncollimated transmission images (detector source distances ≥ 60 cm; phantom source distances ≥ 40 cm) was comparable to that obtained with collimated transmission images. Attenuation coefficients obtained compared well (0.168 cm⁻¹ vs. 0.171 cm⁻¹). The full widths at half maxima differed by less than 0.9 mm. The detection efficiency of the uncollimated source was 2.5 times higher than obtained with the collimated source. The entrance absorbed dose obtained from an uncollimated source was 3.75 times larger than that obtained from the collimated source. An uncollimated transmission source (detector source distance ≥ 60 cm) results in acceptable image characteristics and presents a low cost, low dose, high efficiency option for transmission imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada de Emissão/métodos , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Doses de Radiação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Tecnécio , Tomografia Computadorizada de Emissão/instrumentação
3.
Phys Med Biol ; 52(15): N329-37, 2007 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-17634634

RESUMO

This note proposes the use of a standard inkjet printer to produce radioactive (99m)Tc phantoms that can be used for routine quality control of gamma cameras. The amount of activity that will be deposited on paper per unit area was predicted and compared to the measured activity. The uniformity of the printouts was compared to the uniformity obtained with a standard (57)Co flood source. A scintillation detector connected to a multi-channel analyzer was used to evaluate the uniformity of the printout independently from the gamma camera. Joining two A4 size printed phantoms to create larger sources was evaluated. The spatial resolution obtained with printed sources was compared to that obtained using standard line source techniques. The results indicated that the uniformity of the printed phantoms compared well with those obtained with the (57)Co flood source (integral uniformity 2.29% (printed source) and 2.10% ((57)Co flood source)). There was no difference in the resolution measurements obtained with the printed sources and those obtained with the standard methods. This study demonstrates that affordable phantoms can easily be created to evaluate system uniformity and resolution in any department where a standard PC and inkjet printer are available.


Assuntos
Periféricos de Computador , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Impressão/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/métodos , Tecnécio/química , Desenho de Equipamento , Análise de Falha de Equipamento , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Med Phys ; 27(7): 1523-34, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10947255

RESUMO

Image degradation during single photon emission computed tomography (SPECT) due to attenuation and Compton scatter of photons can cause clinical image artifacts and will also result in inaccurate quantitative data. Therefore attenuation correction methods recently received wide interest. Transmission imaging can be performed to obtain the attenuation coefficients of a nonhomogeneous attenuating medium accurately. The aim of this study was firstly to evaluate the imaging characteristics of the scanning line source assembly. The results obtained with Tc-99m and Ce-139 were compared. Secondly the calculated attenuation coefficients were compared with known values from literature, using Tc-99m and Ce-139 as transmission sources. Lastly the method of acquiring simultaneous transmission and emission data was investigated. This study shows that an attenuation coefficient map can be obtained using a scanning line source for transmission imaging with a dual opposing detector camera. The imaging characteristics of Tc-99m and Ce-139 as transmission sources are similar. The resolution obtained with the Ce-139 line source was poorer than that obtained with the Tc-99m line source. A linear relationship was found between CT numbers and attenuation coefficients for transmission images using both Tc-99m and Ce-139 line sources. The attenuation coefficient value for water was underestimated by 1% using the Tc-99m transmission source and underestimated by 10% using Ce-139 as transmission source. This underestimation of attenuation coefficient values was also obtained in the human study. A myocardial perfusion study processed without and with attenuation correction clearly demonstrated the effect of the attenuation correction in the inferior myocardial region. The potential of using a scanning line source as transmission source with a dual opposing detector camera has been demonstrated in this study. The transmission source, Ce-139 was successfully introduced in this investigation for simultaneous acquisition of transmission and emission data.


Assuntos
Radioisótopos de Cério , Câmaras gama , Tecnécio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Encéfalo/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Músculos/diagnóstico por imagem , Imagens de Fantasmas , Espalhamento de Radiação , Tórax/patologia , Tomografia Computadorizada por Raios X , Água
5.
Nucl Med Commun ; 21(6): 539-44, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10894563

RESUMO

Red cell volume (RCV) and plasma volume (PV) measurements are performed routinely in nuclear medicine departments to diagnose a number of haematological disorders. Currently, 125I-HSA is used as a plasma tracer and 99Tcm-labelled red cells to determine red cell volume. 125I-HSA is not always readily available, leading to inconvenience for patients and medical practitioners. Due to the availability of 99Tcm in nuclear medicine departments, the use of albumin labelled with 99Tcm was investigated. A new 99Tcm-human serum albumin labelling kit (99Tcm-DMP-HSA) was developed by Verbeke and supplied for use in this study. The main aim of the study was to investigate the use of 99Tcm-DMP-HSA for PV determination. Secondly, the feasibility to determine red cell and plasma volume simultaneously using 99Tcm as radionuclide in both instances was investigated. Fourteen healthy volunteers were enrolled in the dual-phase study. During the first study, 99Tcm-DMP-HSA was used as tracer to calculate PV (PV1a) after intravenous administration. Subsequently, 99Tcm-labelled red cells were administered and the PV (PV1b) and RCV (RCV1) were calculated. The second study was repeated within 2 weeks using the conventional method. 125I-HSA and 99Tcm-labelled red cells were administered simultaneously. The PV (PV2) and RCV (RCV2) were calculated. We found that the redistribution of 99Tcm-DMP-HSA is faster than that of 125I-HSA; therefore, the plasma counts obtained at different times were back-extrapolated to time zero for plasma volume calculations. The mean values for the different calculated PVs were 2964+/-470 ml for PV1a, 3006+/-623 ml for PV1b and 3001+/-530 ml for PV2, the reference PV. The confidence intervals indicate no significant differences between plasma volumes PV1a and PV2 and plasma volumes PV1a and PV1b. The mean calculated RCV1 was 2130+/-322 ml; that of RCV2 was 2128+/-353 ml. The difference between RCV1 and RCV2 was not significant. Our results indicate that 99Tcm-DMP-HSA could be used for plasma volume calculation. Red cell and plasma volumes can be calculated simultaneously using 99Tcm as radionuclide in both cases.


Assuntos
Volume de Eritrócitos , Volume Plasmático , Compostos Radiofarmacêuticos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Pentetato de Tecnécio Tc 99m , Humanos , Compostos Radiofarmacêuticos/farmacocinética , Valores de Referência , Análise de Regressão , Agregado de Albumina Marcado com Tecnécio Tc 99m/farmacocinética , Pentetato de Tecnécio Tc 99m/farmacocinética
6.
S Afr Med J ; 72(4): 253-4, 1987 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-3616810

RESUMO

The incidence of autonomic neuropathy in 52 insulin-dependent and 87 non-insulin-dependent diabetic subjects was studied as well as the relationship between the type and duration of diabetes, metabolic control and the association of atypical infarctions with autonomic neuropathy. No statistically significant relationship was found between any parameter and the presence of autonomic neuropathy. Atypical infarctions were not confined to subjects with autonomic neuropathy, but the incidence was considerably higher than that in the general population. Position of the infarction did not determine whether it was silent or not. It is suggested that physicians should be alert to the occurrence of silent infarctions in all diabetics and not only those with clinical evidence of autonomic neuropathy.


Assuntos
Doenças do Sistema Nervoso Autônomo/complicações , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Neuropatias Diabéticas/complicações , Infarto do Miocárdio/complicações , Adolescente , Adulto , Idoso , Criança , Neuropatias Diabéticas/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , África do Sul , Fatores de Tempo