1.
J Appl Clin Med Phys ; 25(1): e14180, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38011008

RESUMO

For commissioning and quality assurance for adaptive workflows on the MR-linac, a dosimeter which can measure time-resolved dose during MR image acquisition is desired. The Blue Physics model 10 scintillation dosimeter is potentially an ideal detector for such measurements. However, some detectors can be influenced by the magnetic field of the MR-linac. To assess the calibration methods and magnetic field dependency of the Blue Physics scintillator in the 1.5 T MR-linac. Several calibration methods were assessed for robustness. Detector characteristics and the influence of the calibration methods were assessed based on dose reproducibility, dose linearity, dose rate dependency, relative output factor (ROF), percentage depth dose profile, axial rotation and the radial detector orientation with respect to the magnetic field. The potential application of time-resolved dynamic dose measurements during MRI acquisition was assessed. A variation of calibration factors was observed for different calibration methods. Dose reproducibility, dose linearity and dose rate stability were all found to be within tolerance and were not significantly affected by different calibration methods. Measurements with the detector showed good correspondence with reference chambers. The ROF and radial orientation dependence measurements were influenced by the calibration method used. Axial detector dependence was assessed and relative readout differences of up to 2.5% were observed. A maximum readout difference of 10.8% was obtained when rotating the detector with respect to the magnetic field. Importantly, measurements with and without MR image acquisition were consistent for both static and dynamic situations. The Blue Physics scintillation detector is suitable for relative dosimetry in the 1.5 T MR-linac when measurements are within or close to calibration conditions.


Assuntos
Aceleradores de Partículas , Dosímetros de Radiação , Humanos , Reprodutibilidade dos Testes , Imagens de Fantasmas , Radiometria/métodos , Imageamento por Ressonância Magnética/métodos , Campos Magnéticos
2.
J Appl Clin Med Phys ; 21(11): 312-321, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33094890

RESUMO

INTRODUCTION: Increased modulation and dynamical delivery of external beam radiotherapy (EBRT), such as volumetric modulated arc therapy (VMAT) with dynamic gantry rotation, continuously variable dose rate (CVDR) and field shapes that change during the beam, place greater demands on the performance of linear accelerators (linac). In this study, the accuracy of the linac beam steering is improved by the application of a new method to determine the gantry-dependent lookup table. METHODS: An improved method of lookup table creation based on service graphing information from the linac is investigated. This minimizes the impact of magnetic hysteresis due to the previous current in the steering magnets, which is dependent on the previous gantry angle. A software tool, programmed with MATLAB®, is used to calculate and export the new optimal lookup table (LUT). RESULTS: This method is efficient requiring little clinical machine time or analysis time, and leads to an improved VMAT delivery with a reduction of about 60 percent in beam steering errors. If the surrounding magnetic field is changed, for example, ramping a nearby magnetic resonance imaging system (MRI), the beam steering LUT optimization can be quickly performed. CONCLUSION: This study shows an improved linac stability using improved lookup tables. Resulting in a lower number of interruptions, preventing down-time, and a lower risk of intrafraction motion due to longer treatment times.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Software