Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Front Neurol ; 14: 1248715, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37693771

RESUMO

Introduction: In a previous manuscript from our research group, the concept of vestibular co-stimulation was investigated in adult subjects who received a cochlear implant (CI). Despite what literature reports state, no signs of vestibular co-stimulation could be observed. Results: In this case report, it was described how a woman, who previously underwent a neurectomy of the left vestibular nerve and suffers from bilateral vestibulopathy (BVP), reported improved balance whenever her CI on the left was stimulating. Unexpectedly, the sway analyses during posturography indeed showed a clinically relevant improvement when the CI was activated. Discussion: Vestibular co-stimulation as a side effect of CI stimulation could not be the explanation in this case due to the ipsilateral vestibular neurectomy. It is more likely that the results can be attributed to the electrically restored auditory input, which serves as an external reference for maintaining balance and spatial orientation. In addition, this patient experienced disturbing tinnitus whenever her CI was deactivated. It is thus plausible that the tinnitus increased her cognitive load, which was already increased because of the BVP, leading to an increased imbalance in the absence of CI stimulation.

2.
Cochlear Implants Int ; 24(2): 95-106, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36448741

RESUMO

OBJECTIVES: With the introduction of more flexible and thinner electrodes, such as Cochlear's Slim Modiolar Electrode, there is a higher risk of electrode insertion problems, in particular the tip foldover. Timely intraoperative detection of the problem would allow for direct intraoperative correction. This paper describes a non-radiological method for intraoperative tip foldover detection that is applicable in all surgical centers and can quickly deliver accurate results. METHODS: Postoperative radiographs of 118 CI-recipients implanted with Nucleus devices were retrospectively analyzed on the presence of a tip foldover. Electrode Voltage Telemetry (EVT), also called Electric Field Imaging, was performed by means of Cochlear's EVT software tool, which is now integrated into Custom Sound-EP as the Trans-Impedance-Matrix measurement option. Tip foldover detection was automated by using the linear Hough transform for extracting straight-line patterns in the Trans-Impedance Matrix's heatmap. RESULTS: The six cases of electrode tip foldover were accurately identified by the EVT measurements, including two cases with folding location very close to the electrode tip (contact 20). CONCLUSION: Electrode Voltage Telemetry measures the Trans-Impedance Matrix, which can accurately detect tip foldovers of the cochlear implant electrodes within 1 min. This method can be reliably applied in all patients with normal cochlear anatomy and is able to intraoperatively detect foldovers localized even very close to the electrode tip. Application of the linear Hough transform allows for automatic detection of electrode tip foldovers that shows excellent agreement with visual evaluation of the radiological images and the transimpedance matrix's heatmap.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Cóclea/cirurgia , Eletrodos Implantados , Telemetria/métodos
3.
J Voice ; 37(6): 973.e11-973.e14, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34294489

RESUMO

INTRODUCTION AND AIM: Atraumatic laryngeal fractures are extremely rare and are most commonly provoked by sneezing or coughing. Only seven cases have been described in medical literature, and only one case described a fracture after swallowing. We present two cases of atraumatic laryngeal fracture after swallowing. CASE REPORT: A 37-year-old male presented to the outpatient ENT clinic with severe dysphonia and odynophagia. He reported feeling a crack in the throat after swallowing with a flexed head. The patient's physical examination showed diffuse swelling and tenderness over the thyroid cartilage without subcutaneous emphysema. Flexible nasolaryngoscopy showed a large right true vocal fold hematoma with normal vocal fold movement. Computed tomography (CT) showed a fracture of the thyroid. Treatment consisted of corticosteroids and pantoprazole. Two years later he presented again at the emergency department with extreme odynophagia after suffering a knee punch on the larynx. CT showed a new fracture line, slightly off midline to the left in the thyroid cartilage. A 42-year-old male presented at the emergency department with odynophagia, dysphonia, and fever after feeling a crack in the throat during forceful swallowing in an extended neck position. Physical examination demonstrated a painful thyroid cartilage with subcutaneous emphysema. Flexible nasolaryngoscopy was normal but CT scan showed a slightly displaced fracture line of the median thyroid cartilage. Complaints gradually disappeared with conservative treatment with corticosteroids and antibiotics. CONCLUSION: Congenital anomalies by abnormal mineralization and ossification could lead to focal weakness of the thyroid cartilage and thus predispose to non-traumatic fractures. The double triad of odynophagia, dysphagia, and dysphonia after sneezing, coughing or swallowing should raise the physician's attention to the possibility of thyroid cartilage fracture, especially after feeling or hearing a crack. Further investigation is obligatory with high-resolution CT of the neck and examination by an ENT specialist.


Assuntos
Disfonia , Doenças da Laringe , Enfisema Subcutâneo , Masculino , Humanos , Adulto , Espirro , Disfonia/diagnóstico , Disfonia/etiologia , Doenças da Laringe/diagnóstico , Cartilagem Tireóidea , Corticosteroides
4.
Dysphagia ; 38(3): 886-895, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36121560

RESUMO

BACKGROUND: Prophylactic swallowing exercises (PSE) during radiotherapy can significantly reduce dysphagia after radiotherapy in head and neck cancer (HNC). However, its positive effects are hampered by low adherence rates during the burdensome therapy period. Hence, the main goal of this multicenter randomized controlled trial (RCT) was to investigate the effect of 3 different service-delivery modes on actual patients' adherence. METHODS: A total of 148 oropharyngeal cancer patients treated with primary (chemo)radiotherapy were randomly assigned to a 4 weeks PSE program, either diary-supported (paper group; n = 49), app-supported (app group; n = 49) or therapist-supported (therapist group; n = 50). Participants practiced 5 days/week, daily alternating tongue strengthening exercises with chin tuck against resistance exercises. Adherence was measured as the percentage of completed exercise repetitions per week (%reps). Statistical analysis was performed by means of SPSSv27, using Linear Mixed-effects Models with post hoc pairwise testing and Bonferroni-Holm correction. RESULTS: Adherence and evolution of adherence over time was significantly different between the three groups (p < .001). Adherence rates decreased in all three groups during the 4 training weeks (p < .001). During all 4 weeks, the therapist group achieved the highest adherence rates, whilst the app group showed the lowest adherence rates. CONCLUSIONS: PSE adherence decreased during the first 4 radiotherapy weeks regardless of group, but with a significant difference between groups. The therapist group achieved the highest adherence rates with a rather limited decline, therefore, increasing the face-to-face contact with a speech-language therapist can overcome the well-known problem of low adherence to PSE in this population. TRIAL REGISTRATION: Trial registration: ISRCTN, ISRCTN98243550. Registered December 21, 2018 - retrospectively registered, https://www.isrctn.com/ISRCTN98243550?q=gwen%20van%20nuffelen&filters=&sort=&offset=1&totalResults=2&page=1&pageSize=10&searchType=basic-search .


Assuntos
Transtornos de Deglutição , Neoplasias de Cabeça e Pescoço , Neoplasias Orofaríngeas , Humanos , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/prevenção & controle , Deglutição , Quimiorradioterapia/efeitos adversos , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias Orofaríngeas/radioterapia , Terapia por Exercício
5.
Hear Res ; 426: 108563, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35794046

RESUMO

Measurement of the complex electrical impedance of the electrode contacts can provide new insights into the factors playing a role in the preservation of residual hearing with cochlear implants (CIs). However, unraveling the contributions related to the different phenomena from impedance data necessitates more advanced measurement and analysis techniques. The present study explores a new impedance measurement option recently included into the cochlear-implant programming software and aims to contribute to a more solid basis for the clinical use of impedance measures as a biomarker for fibrous tissue formation. Twenty adult CI-recipients were followed from surgery until 1 year after implantation by means of Electrode Voltage Telemetry (EVT), also called Electric Field Imaging or TransImpedance-Matrix measurement, and a 4-point technique for probing the voltage between adjacent electrode contacts. The data were compared to the electrode location derived from computed tomography, and to the device usage log. Using our impedance model for electrical stimulation of the cochlea, the polarization impedance related the electrode-tissue interface was determined, and the bulk impedance (access resistance) was split into a near-field and a far-field component. On average, the polarization impedance increased abruptly after surgery, indicating a strong passivation of the electrode contacts before cochlear-implant initiation. Its initial rise resolved almost completely soon after device switchon (2-4 weeks). The gradual increase of the access resistance mainly happened during the first 40 days on a time scale very similar to that observed in a guinea-pig study correlating impedance changes to fibrous tissue growth. The higher increase towards the round window is consistent with the higher amount of tissue observed in histological animal studies close to the electrode entry point. While the initial changes were due to the near-field resistance, the far-field resistance began to rise only after one month for half of the study group, once the near-field component had reached its critical value. This suggests indeed fibrosis initiating near the electrode contacts and spreading thereafter farther away. The near-field resistance positively correlated to device usage. EVT data allow for a further decomposition of the impedance at a cochlear-implant electrode, yielding a more detailed description of the postoperative intracochlear phenomena, such as fibrosis.


Assuntos
Implante Coclear , Implantes Cocleares , Cobaias , Animais , Impedância Elétrica , Cóclea/fisiologia , Fibrose , Biomarcadores
6.
J Int Adv Otol ; 18(2): 150-157, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35418364

RESUMO

BACKGROUND: Vestibular co-stimulation is a side effect of cochlear implant stimulation. The electrical currents delivered by the cochlear implant can spread toward the vestibular system and thus stimulate it. The aim of the study is to evaluate whether it is feasible to functionally restore the balance by modifying the vestibular co-stimulation. METHODS: Four adult patients, who had received a commercially available cochlear implant previously, were enrolled. Counterbalanced biphasic pulses were presented as bursts or as an amplitude-modulated biphasic pulse train (modulation frequencies ranging from 1 to 500 Hz) at the participant's upper comfortable level for electrical stimulation. Subjective sensations and vestibular-mediated eye movements were used for evaluating the possible effects of vestibular co-stimulation. RESULTS: One participant experienced a cyclic tilting of his head in response to an amplitude-modulated biphasic pulse train with a modulation frequency of 2 and 400 Hz. However, during a follow-up visit, the sensation could not be replicated. CONCLUSION: Subjective vestibular sensations or vestibular-mediated eye movements could not be electrically evoked with a commercially available cochlear implant in 4 adult patients with almost normal vestibular function. Therefore, customized design of the hard-, firm-, and/or software of the commercially available cochlear implant might be necessary in order to electrically restore vestibular performance.


Assuntos
Implante Coclear , Implantes Cocleares , Vestíbulo do Labirinto , Adulto , Estimulação Elétrica , Humanos , Sensação
7.
Neuroradiology ; 64(5): 1011-1020, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35149883

RESUMO

PURPOSE: Heavily T2-weighted 3D FLAIR (hT2w-3D-FLAIR) sequence with constant flip angle (CFA) has been reported as being more sensitive to low concentrations of gadolinium (Gd) enabling endolymphatic hydrops (EH) visualization. The purpose of this study was to compare signal-to-noise (SNR) ratio, detection rate of EH, and increased perilymphatic enhancement (PE) as well as diagnostic accuracy in diagnosing definite Menière's disease (MD), using 3D-SPACE FLAIR versus conventional 3D-TSE FLAIR. METHODS: This retrospective study included 29 definite MD patients who underwent a 4-h delayed intravenous (IV) Gd-enhanced 3D-TSE FLAIR and 3D-SPACE FLAIR MRI between February 2019 and February 2020. MR images were qualitatively and quantitatively analyzed twice by 2 experienced head and neck radiologists. Qualitative assessment included grading of cochlear and vestibular EH and visual comparison of PE. Quantitative assessment of PE was performed by placing a region of interest (ROI) and ratio calculation in the basal turn of the cochlea and the brainstem. RESULTS: The intra- and inter-reader reliability for grading of EH and PE was excellent (0.7 < kappa < 0.9) for 3D-SPACE FLAIR and exceeded the values for 3D-TSE FLAIR (0.5 < kappa < 0.9) The combination of EH and visual assessment of PE has the highest diagnostic accuracy in diagnosing definite MD on 3D-SPACE FLAIR with a sensitivity of 0.91 and a specificity of 0.98 resulting in a sensitivity raise of 6% compared to 3D-TSE FLAIR. CONCLUSION: Four-hour delayed IV Gd-enhanced 3D-SPACE FLAIR sequence has a higher sensitivity and reproducibility than 3D-TSE FLAIR for the visualization of EH and increased PE in definite MD patients.


Assuntos
Hidropisia Endolinfática , Doença de Meniere , Meios de Contraste , Hidropisia Endolinfática/diagnóstico por imagem , Gadolínio , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Doença de Meniere/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Otol Neurotol ; 43(1): e79-e87, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34607996

RESUMO

INTRODUCTION AND AIM: There is no consensus in literature on the most optimal follow-up imaging protocol for non-echoplanar diffusion-weighted magnetic resonance imaging (non-EP DW MRI) after the canal wall-up bony obliteration tympanoplasty. Clearly, no residual cholesteatoma should be missed but on the other hand, unnecessary MR controls should be avoided. The aim of this study is to evaluate the postoperative results of non-EP DW MRI after canal wall-up bony obliteration tympanoplasty surgery at our Institute and to propose an optimal postoperative MR imaging scheme based on our data. MATERIAL AND METHODS: Retrospective cohort study; all 271 patients who underwent the bony obliteration tympanoplasty between January 2010 and January 2016 with follow-up at our Institute were included. A postoperative MR imaging was systematically performed at 1 year after surgery and repeated at either 5 or both 3 and 5 years after surgery, based on the preferences of the surgeon. Variables of interest were retrieved from electronic patient records. RESULTS: The median follow-up time was 60 months (inter-quartile range 56-62 mo). Two hundred seventy-one patients (100%) received a 1-year MRI, 107 (39%) a 3-year MRI, and 216 (79.7%%) a 5-year MRI. Residual cholesteatoma was found in nine cases (3.3%), corresponding with an estimated residual rate at 5 years follow-up of 3.7% when using Kaplan-Meier analysis. Of these nine cases, six cases of residual cholesteatoma (66.7%) were detected at the 1-year MRI (12-14 mo postsurgery), two cases (22.2%) at the 3-year MRI (35-39 mo postsurgery), and one case (11.1%) at the 5-year MRI (51 mo postsurgery, in this patient no 3-year MRI was performed). An uncertain MRI result was found in 15 cases, presenting as relatively hyperintense lesions. However, subsequent follow-up scans did not show persistent evidence for residual disease in 14 of these 15 cases. CONCLUSIONS: A postoperative MRI scan after 1 and 5 years is essential to detect early and late residual cholesteatoma. In our cohort, 22.2% of residual cases were detected at the 3-year MRI. However, this percentage could potentially have been higher when all patients would have received a 3-year MRI. Therefore, in order to detect residual disease as soon as possible, we propose to perform an MRI scan at 1, 3, and 5 years after the bony obliteration tympanoplasty. In cases with an unclear MR result, we suggest a repeat MRI after 12 months.


Assuntos
Colesteatoma da Orelha Média , Timpanoplastia , Colesteatoma da Orelha Média/diagnóstico por imagem , Colesteatoma da Orelha Média/cirurgia , Progressão da Doença , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Processo Mastoide/cirurgia , Recidiva Local de Neoplasia/cirurgia , Neoplasia Residual/patologia , Estudos Retrospectivos , Timpanoplastia/métodos
9.
J Clin Med ; 10(17)2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34501241

RESUMO

Electrical stimulation with cochlear implants is able to significantly suppress the tinnitus sensations in 25-72% of implanted patients. Up to this point, no clear predictors for the effectiveness of tinnitus suppression with cochlear implants have been found and this substantially limits the possibility of the application of cochlear implants for this purpose. The objective of the study was to investigate if a trial electrical round window stimulation (RWS) could be used as a diagnostic tool for identifying candidates in whom electrical stimulation would be successful as treatment for tinnitus. Thirty-four patients with unilateral severe tinnitus and ipsilateral moderate to severe sensorineural hearing loss underwent a trial RWS under local anesthesia. Thirteen patients received a cochlear implant. All patients qualified for cochlear implantation on the basis of the trial RWS showed tinnitus suppression with the implant switched on. Complete or almost complete tinnitus suppression was obtained in 77% and partial in 23%. The mean tinnitus loudness reduction was 68% (VAS score reduction from 7.7 to 2.5). False negative results are estimated not to exceed 10-15%. We conclude that significant tinnitus suppression achieved during trial RWS under local anesthesia is a simple procedure allowing the efficient identification of candidates in whom electrical stimulation with a cochlear implant would be successful as treatment for intractable tinnitus.

10.
Eur Arch Otorhinolaryngol ; 278(12): 4743-4748, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33609177

RESUMO

OBJECTIVE: The MO-meatocanalplasty is the oblique modification of the M-meatoplasty. The MO-meatocanalplasty was designed to address the superior quadrants of the meatus and the bony canal without the need for a retro-auricular incision. This retrospective analysis was performed to evaluate the long-term results of the MO-meatocanalplasty in patients with a narrow external auditory canal (EAC) with recurrent otitis externa or in patients unable to wear a hearing aid. METHODS: Twenty-two ears in twenty consecutive patients who received a MO-meatocanalplasty for a narrow EAC with recurrent otitis externa or the inability to wear a hearing aid were analysed retrospectively. There were no patients included with any type of previous or planned second stage tympanoplasty procedures. A follow-up period of 3 years was analysed for postoperative recurrent narrowing, the self-cleaning capacity of the EAC, the recurrence of otitis externa, the inability to wear a hearing aid, change in hearing level and for all types of aesthetical complaints. RESULTS: The MO-meatocanalplasty procedure was effective in 82% (n = 18). Postoperative recurrent narrowing was detected in 9% (n = 2). Insufficient self-cleaning capacity of the EAC was 9.1% (n = 2). The ability to wear a hearing aid was restored in all patients with the need for a hearing aid. No aesthetical complaints were reported. CONCLUSION: The MO-meatocanalplasty is an effective, safe and aesthetical accepted procedure to address the narrow meatus and external auditory canal. With this procedure, there is no need for a retro-auricular incision in order to create a well aerated, dry and self-cleaning EAC in patients with a narrow EAC with recurrent otitis externa or in patient with the inability to wear a hearing aid.


Assuntos
Auxiliares de Audição , Otite Externa , Meato Acústico Externo/cirurgia , Humanos , Otite Externa/cirurgia , Estudos Retrospectivos , Timpanoplastia
11.
Eur Arch Otorhinolaryngol ; 278(12): 4783-4793, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33492418

RESUMO

PURPOSE: In this retrospective study the relationship between cochleovestibular function and a magnetic resonance imaging (MRI-) based classification system of endolymphatic hydrops was investigated. METHODS: Seventy-eight patients with unilateral definite Menière's disease who underwent MRI were included. The parameters of Pure Tone Audiometry (PTA), caloric irrigation test, cervical vestibular evoked myogenic potentials, and video Head Impulse Test were compared between the grades of endolymphatic hydrops (EH) and perilymphatic enhancement (PE) on MRI. RESULTS: The low-frequency PTA was significantly different between cochlear EH grades I and II (p = 0.036; Grade I: mean (Standard Deviation, SD) = 51 decibel Hearing Level (dB HL) (18 dB HL); Grade II: mean (SD) = 60 dB HL (16 dB HL)), and vestibular EH grades 0 and III (p = 0.018; Grade 0: mean (SD) = 43 dB HL (21 dB HL); Grade III: mean = 60 dB HL (10 dB HL)). The ipsilateral caloric sum of ears with vestibular EH grade I (n = 6) was increased with regards to vestibular EH grades 0 (p = 0.001), II (p < 0.001), and III (p < 0.001) (Grade 0: mean (SD) = 24°/s (15°/s); Grade I: mean (SD) = 47°/s (11°/s); Grade II: mean (SD) = 21°/s (13°/s); Grade III: mean (SD) = 16°/s (8°/s)). CONCLUSION: According to these results we can conclude that only the highest grades of cochlear and vestibular EH seem to be associated with decreased cochleovestibular functioning.


Assuntos
Hidropisia Endolinfática , Doença de Meniere , Potenciais Evocados Miogênicos Vestibulares , Hidropisia Endolinfática/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Doença de Meniere/diagnóstico por imagem , Estudos Retrospectivos
12.
Eur Arch Otorhinolaryngol ; 278(6): 1805-1813, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32761272

RESUMO

OBJECTIVE: To evaluate early results on hygiene, safety and functional outcome in a population undergoing a canal wall up technique with bony obliteration of the mastoid and epitympanic space (CWU-BOT) for extensive cholesteatoma, performed by a single surgeon. This study compares different techniques of tympanic membrane reconstruction, viz. allografts and autografts. PATIENTS: A consecutive series of 61 ears with acquired cholesteatoma treated with primary or revision CWU-BOT surgery from 2009 to 2014. INTERVENTION: Obliteration was performed by the use of cortical bone-chips and bone pâté. Patients were followed up with micro-otoscopy and MRI with diffusion-weighted imaging. Ossicular reconstruction was performed using a remodelled autologous or allogenic incus or malleus. MAIN OUTCOME MEASURES: Residual and recurrence rate and short- and mid-term hearing outcome prior to any revision tympanoplasty were analysed, the effect of type of tympanic membrane reconstruction was considered. RESULTS: 44 Ears were primary cholesteatoma cases, 17 cases were referred for revision surgery. Mean postoperative follow up was 45 months (SD 18.08) and mean follow-up until the last non-EP DW MRI 42 months (SD 17.72). Recurrent disease was present in 3%, no residual disease was present. An AC gain was seen in 75% of all ears undergoing ossicular reconstruction. CONCLUSION: Reproducible safety, hygiene and hearing results with limited recurrence and residual disease can be obtained by younger otologic surgeons performing the BOT-CWU for extensive cholesteatoma while using a variety of grafts for tympano-ossicular reconstruction. The tympano-ossicular allograft nevertheless shows superior hearing results when a mobile intact stapes is present. LEVEL OF EVIDENCE: Level 4.


Assuntos
Colesteatoma da Orelha Média , Timpanoplastia , Aloenxertos , Autoenxertos , Colesteatoma da Orelha Média/cirurgia , Audição , Humanos , Higiene , Processo Mastoide , Recidiva Local de Neoplasia , Estudos Retrospectivos , Resultado do Tratamento , Membrana Timpânica/diagnóstico por imagem , Membrana Timpânica/cirurgia
13.
Int J Pediatr Otorhinolaryngol ; 138: 110195, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32705989

RESUMO

INTRODUCTION: Necrotizing soft tissue infections (NSTIs) are rare but often lethal. Early diagnosis and aggressive surgical debridement are essential to achieve the best possible outcome. CASE PRESENTATION: A 12-year old boy was diagnosed with a necrotizing soft tissue infection following elective revision surgery for functional impairment resulting from scar tissue of the neck. Fever and inflammation of the surgical wound manifested 24-36 hours postoperatively. Antibiotic therapy with amoxicillin-clavulanic acid was initiated, but the patient was unresponsive. Ultrasonography, a wound culture and surgical exploration confirmed the diagnosis. The culture was positive for a Streptococcus pyogenes infection and antibiotic treatment was switched to penicillin and clindamycin. Following the diagnosis, surgical debridement was performed subcutaneously, and only necrotic tissue was removed to preserve as much skin tissue as possible. After eradication of the infection, vacuum-assisted closure of the wound was used to close the subcutaneous space. The patient was discharged after 40 days. CONCLUSION: In this patient, we treated a necrotizing soft tissue infection with antibiotics, skin sparing surgeries and negative pressure wound therapy (NPWT). We used ultrasonography as imaging technique to help with the diagnosis. The extensiveness of surgical debridement was rather limited. We focused on opening all affected fascial layers. The surgical debridement was subcutaneous, and only necrotic tissue was removed. Because of the location in the neck, we tried to avoid an aggressive skin debridement to preserve as much skin tissue as possible. Negative pressure wound therapy is not frequently used in this context but it contributed to an enhanced wound healing. Ultrasonography for diagnosing NSTIs is useful, but the clinical findings and an explorative surgery will remain most important.


Assuntos
Cicatriz/cirurgia , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Fasciite Necrosante , Tratamento de Ferimentos com Pressão Negativa , Infecções dos Tecidos Moles , Combinação Amoxicilina e Clavulanato de Potássio , Criança , Desbridamento , Fasciite Necrosante/diagnóstico , Fasciite Necrosante/etiologia , Fasciite Necrosante/terapia , Humanos , Masculino , Infecções dos Tecidos Moles/diagnóstico , Infecções dos Tecidos Moles/etiologia , Infecções dos Tecidos Moles/terapia , Cicatrização
14.
J Int Adv Otol ; 16(1): 123-126, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32209523

RESUMO

In this case report, the air-conducted cervical vestibular evoked myogenic potentials (AC cVEMP) test was only sensitive for the left superior semicircular canal dehiscence (SCD), even though the contralateral SCD was of equal length (2.5 mm). Furthermore, a lysis of the processus lenticularis incudis caused a real conductive hearing loss in the left ear. A diminished left AC cVEMP was thus expected, but the opposite was shown (increased corrected amplitude, lowered detection threshold). The patient only experienced hearing loss, so middle ear surgery was performed to repair the lysis. The postoperative AC cVEMP showed a further "uncovering" of the SCD with increased corrected amplitude on the left but no vestibular symptoms. The significance of an SCD should be interpreted with caution, even when the AC cVEMP and the imaging are significant. Furthermore, AC cVEMPs should not be considered as evidence for the absence or presence of conductive hearing loss.


Assuntos
Perda Auditiva Condutiva/etiologia , Bigorna/patologia , Deiscência do Canal Semicircular/diagnóstico por imagem , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Audiometria de Tons Puros/métodos , Orelha Média/cirurgia , Feminino , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/cirurgia , Humanos , Bigorna/diagnóstico por imagem , Bigorna/cirurgia , Pessoa de Meia-Idade , Otosclerose/diagnóstico , Deiscência do Canal Semicircular/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
15.
Trials ; 21(1): 237, 2020 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-32122397

RESUMO

BACKGROUND: Dysphagia is a common and serious complication after (chemo)radiotherapy (CRT) for head-and-neck cancer (HNC) patients. Prophylactic swallowing exercises (PSE) can have a significantly positive effect on post-treatment swallowing function. However, low adherence rates are a key issue in undermining this positive effect. This current randomized trial will investigate the effect of adherence-improving measures on patients' swallowing function, adherence and quality of life (QOL). METHODS: This ongoing trial will explore the difference in adherence and swallowing-related outcome variables during and after PSE in HNC patients performing the same therapy schedule, receiving different delivery methods. One hundred and fifty patients treated in various hospitals will be divided into three groups. Group 1 performs PSE at home, group 2 practices at home with continuous counseling through an app and group 3 receives face-to-face therapy by a speech and language pathologist. The exercises consist of tongue-strengthening exercises and chin-tuck against resistance with effortful swallow. The Iowa Oral Performance Instrument and the Swallowing Exercise Aid are used for practicing. Patients are evaluated before, during and after treatment by means of strength measurements, swallowing and QOL questionnaires. DISCUSSION: Since low adherence rates undermine the positive impact of PSE on post-treatment swallowing function, there is need to develop an efficient PSE protocol maximizing adherence rates. TRIAL REGISTRATION: ISRCTN, ID: ISRCTN98243550. Registered retrospectively on 21 December 2018.


Assuntos
Quimiorradioterapia/efeitos adversos , Transtornos de Deglutição/prevenção & controle , Deglutição , Terapia por Exercício/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Qualidade de Vida , Bélgica , Transtornos de Deglutição/etiologia , Humanos , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Resultado do Tratamento
16.
Laryngoscope ; 130(11): E654-E661, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31840827

RESUMO

OBJECTIVES/HYPOTHESIS: High-speed videoendoscopy (HSV) has potential to objectively quantify vibratory vocal fold characteristics during phonation. Glottal Analysis Tools (GAT) version 2018, developed in Erlangen, Germany, is software for determining various glottal area waveform (GAW) quantities. Before having GAT analyze HSV videos, segmenters have to define glottis manually across videos in a semiautomatic segmentation protocol. Such interventions are hypothesized to induce variability of subsequent GAW measure computation across segmenters and may attenuate GAT measures' reliability to a certain point. This study explored intersegmenter variability in GAT's GAW measures based on semiautomatic image processing. STUDY DESIGN: Cohort study of rater reliability. METHODS: In total, 20 HSV videos from normophonic and dysphonic subjects with various laryngeal disorders were selected for this study and segmented by three trained segmenters. They separately segmented glottis areas in the same frame sets of the videos. Upon analysis of GAW, GAT offers 46 measures related to topologic GAW dynamic characteristics, GAW periodicity and perturbation characteristics, and GAW harmonic components. To address GAT's reliability, intersegmenter-based variability in these measures was examined with intraclass correlation coefficient (ICC). RESULTS: In general, ICC behavior of the 46 GAW measures across three raters was highly acceptable. ICC of one parameter was moderate (0.5 < ICC < 0.75), good for seven parameters (0.75 < ICC < 0.9), and excellent for 38 parameters (0.9 < ICC). CONCLUSIONS: Overall, high ICC values confirm clinical applicability of GAT for objective and quantitative assessment of HSV. Small intersegmenter differences with actual small parameter differences suggest that manual or semiautomatic segmentation in GAT does not noticeably influence clinical assessment outcome. To guarantee the software's performance, we suggest segmentation training before clinical application. LEVEL OF EVIDENCE: 2b Laryngoscope, 130:E654-E661, 2020.


Assuntos
Glote/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Doenças da Laringe/diagnóstico por imagem , Laringoscopia/métodos , Gravação em Vídeo/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Fonação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Vibração , Prega Vocal/diagnóstico por imagem
17.
Neuroradiology ; 61(4): 421-429, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30719545

RESUMO

PURPOSE: There is still a clinical-radiologic discrepancy in patients with Menière's disease (MD). Therefore, the purpose of this study was to investigate the reliability of current MRI endolymphatic hydrops (EH) criteria according to Baráth in a larger study population and the clinical utility of new imaging signs such as a supplementary fourth low-grade vestibular EH and the degree of perilymphatic enhancement (PE) in patients with Menière's disease (MD). METHODS: This retrospective study included 148 patients with probable or definite MD according to the 2015 American Academy of Otolaryngology, Head and Neck Surgery criteria who underwent a 4-h delayed intravenous Gd-enhanced 3D-FLAIR MRI between January 2015 and December 2016. Vestibular EH, vestibular PE, cochlear EH, and cochlear PE were reviewed twice by three experienced readers. Cohen's Kappa and multivariate logistic regression were used for analysis. RESULTS: The intra- and inter-reader reliability for the grading of vestibular-cochlear EH and PE was excellent (0.7 < kappa < 0.9). The two most distinctive characteristics to identify MD are cochlear PE and vestibular EH which combined gave a sensitivity and specificity of 79.5 and 93.6%. By addition of a lower grade vestibular EH, the sensitivity improved to 84.6% without losing specificity (92.3%). Cochlear EH nor vestibular PE showed added-value. CONCLUSIONS: MRI using vestibular-cochlear EH and PE grading system is a reliable technique. A four-stage vestibular EH grading system in combination with cochlear PE assessment gives the best diagnostic accuracy to detect MD.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doença de Meniere/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Doença de Meniere/classificação , Pessoa de Meia-Idade , Compostos Organometálicos , Perilinfa/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
Otol Neurotol ; 40(1): e25-e31, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30531639

RESUMO

OBJECTIVE: To report the long-term follow-up with diffusion-weighted magnetic resonance imaging (DW MRI) after subtotal petrosectomy (SP) with blind sac closure of the external auditory canal for extensive cholesteatoma and chronic suppurative otitis media. STUDY DESIGN: Retrospective clinical record study. SETTING: Tertiary referral center. PATIENTS: Thirty-one patients (31 ears) with extensive cholesteatoma and 17 patients (19 ears) with chronic suppurative otitis media without cholesteatoma who underwent SP between July 1995 and December 2015. INTERVENTIONS: All 48 patients were followed clinically and with DW MRI to rule out residual cholesteatoma. MAIN OUTCOME MEASURE: Residual cholesteatoma, indicated by a marked hyperintensity on non-echoplanar (non-EP) DW MRI. RESULTS: In the cholesteatoma group the mean interval between surgery and the latest DW MRI was 3.9 years. Seven patients presented with a residual cholesteatoma pearl. The mean interval between surgery and detection of residual disease was 3.7 years. In the chronic suppurative otitis media group the mean interval between surgery and the latest DW MRI was 5.3 years. Residual cholesteatoma was found in three patients. Mean interval between surgery and the detection of disease was 4.5 years. CONCLUSIONS: This study shows the importance of DW MRI in the follow-up after SP for cholesteatoma and chronic suppurative otitis media. A little higher residual cholesteatoma rate was found compared with earlier studies, where patients were followed only clinically. One may wonder whether reintervention is always needed or whether in selected cases with small pearls, one may still observe these by a watchful waiting policy with DW MRI.


Assuntos
Colesteatoma da Orelha Média/cirurgia , Craniotomia/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Meato Acústico Externo/cirurgia , Otite Média Supurativa/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Colesteatoma da Orelha Média/diagnóstico por imagem , Meato Acústico Externo/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Otite Média Supurativa/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
19.
Otol Neurotol ; 39(6): 715-723, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29889781

RESUMO

OBJECTIVE: To present the hearing results of a 5-year longitudinal study in a pediatric population undergoing surgery for extensive cholesteatoma using a canal wall up (CWU) approach with bony obliteration of the mastoid and epitympanic space, with a standard residual rate of 5.8%, a recurrence rate of 2.9%, and all ears waterproof, free of otorrhea and all external ear canals patent and self-cleaning. STUDY DESIGN: Retrospective consecutive study. PATIENTS: Thirty-three children (≤18 yr) undergoing surgery for cholesteatoma (34 ears) between 1997 and 2009. INTERVENTIONS: Therapeutic. SETTING: Tertiary referral center. MAIN OUTCOME MEASURES: Hearing and gain in hearing at 1- and 5-year postsurgery: (1) pure-tone average (PTA), (2) pure-tone average high frequency, (3) pure-tone average including 3 kHz, (4) bone conduction at corresponding frequency averages, (5) gain at corresponding air conduction and bone conduction (gain at corresponding air conduction) frequency averages. (6) The Amsterdam Hearing Evaluation Plots were used to study the individual cases. RESULTS: The Amsterdam Hearing Evaluation Plots at 5-year showed in 58.8% of patients a positive gain air conduction. In 23.5% a successful functional result was achieved, defined as an air-bone gap closure to 20 dBHL or less. In 6 patients (17.6%) a limited bone conduction deterioration was shown all limited to maximum 20 dBHL. CONCLUSION: The CWU bony obliteration tympanoplasty in a consecutive series of pediatric extensive cholesteatoma shows a similar to slightly improved hearing outcome as compared with CWU surgery without BOT. Although the series shows a clearly reduced reoperation rate and a significantly improved safety and hygienic outcome as compared with CWU without BOT, better hearing outcomes remain desirable in this group of children.


Assuntos
Colesteatoma da Orelha Média/cirurgia , Timpanoplastia/métodos , Adolescente , Criança , Feminino , Audição , Humanos , Estudos Longitudinais , Masculino , Estudos Retrospectivos , Resultado do Tratamento
20.
J Clin Oncol ; 35(30): 3458-3464, 2017 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-28854069

RESUMO

Purpose To assess the standardized implementation and reporting of surveillance [18F]fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) scan of the neck in locoregionally advanced head-and-neck squamous cell carcinoma (LAHNSCC) after concurrent chemoradiotherapy (CCRT). Patients and Methods We performed a prospective multicenter study of FDG-PET/CT scanning 12 weeks after CCRT in newly diagnosed patients with LAHNSCC (stage IVa/b) that used standardized reconstruction and Hopkins reporting criteria. The reference standard was histology or > 12 months of clinical follow-up. The primary outcome measure was the negative predictive value (NPV) of FDG-PET/CT scans and other supporting diagnostic test characteristics, including time dependency with increasing follow-up time. Results Of 152 patients, 125 had adequate primary tumor control after CCRT and entered follow-up (median, 20.4 months). Twenty-three (18.4%) had residual neck disease. Overall, NPV was 92.1% (95% CI, 86.9% to 95.3%; null hypothesis: NPV = 85%; P = .012) with sensitivity of 65.2% (95% CI, 44.9% to 81.2%), specificity of 91.2% (95% CI, 84.1% to 95.3%), positive predictive value of 62.5% (95% CI, 45.5% to 76.9%), and accuracy of 86.4% (95% CI, 79.3% to 91.3%). Sensitivity was time dependent and high for residual disease manifesting up to 9 months after imaging but lower (59.7%) for disease detected up to 12 months after imaging. Standardized reporting criteria reduced the number of equivocal reports (95% CI for the difference, 2.6% to 15.0%; P = .003). Test characteristics were not improved with the addition of lymph node CT morphology criteria. Conclusion FDG-PET/CT surveillance using Hopkins criteria 12 weeks after CCRT is reliable in LAHNSCC except for late manifesting residual disease, which may require an additional surveillance scan at 1 year after CCRT to be detected.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/terapia , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Carcinoma de Células Escamosas/diagnóstico , Quimiorradioterapia , Feminino , Seguimentos , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...