Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microsc ; 270(3): 359-373, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29574724

RESUMO

Since the recent boost in the usage of electron microscopy in life-science research, there is a great need for new methods. Recently minimal resin embedding methods have been successfully introduced in the sample preparation for focused-ion beam scanning electron microscopy (FIB-SEM). In these methods several possibilities are given to remove as much resin as possible from the surface of cultured cells or multicellular organisms. Here we introduce an alternative way in the minimal resin embedding method to remove excess of resin from two widely different cell types by the use of Mascotte filter paper. Our goal in correlative light and electron microscopic studies of immunogold-labelled breast cancer SKBR3 cells was to visualise gold-labelled HER2 plasma membrane proteins as well as the intracellular structures of flat and round cells. We found a significant difference (p < 0.001) in the number of gold particles of selected cells per 0.6 µm2 cell surface: on average a flat cell contained 2.46 ± 1.98 gold particles, and a round cell 5.66 ± 2.92 gold particles. Moreover, there was a clear difference in the subcellular organisation of these two cells. The round SKBR3 cell contained many organelles, such as mitochondria, Golgi and endoplasmic reticulum, when compared with flat SKBR3 cells. Our next goal was to visualise crosswall associated organelles, septal pore caps, of Rhizoctonia solani fungal cells by the combined use of a heavy metal staining and our extremely thin layer plastification (ETLP) method. At low magnifications this resulted into easily finding septa which appeared as bright crosswalls in the back-scattered electron mode in the scanning electron microscope. Then, a septum was selected for FIB-SEM. Cross-sectioned views clearly revealed the perforate septal pore cap of R. solani next to other structures, such as mitochondria, endoplasmic reticulum, lipid bodies, dolipore septum, and the pore channel. As the ETLP method was applied on two widely different cell types, the use of the ETLP method will be beneficial to correlative studies of other cell model systems and multicellular organisms.


Assuntos
Microscopia Eletrônica de Varredura/métodos , Organelas/ultraestrutura , Rhizoctonia/ultraestrutura , Manejo de Espécimes/métodos , Propriedades de Superfície , Células Tumorais Cultivadas/ultraestrutura , Humanos
2.
J Struct Biol ; 199(1): 1-11, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28552722

RESUMO

Immuno-electron microscopy is commonly performed with the use of antibodies. In the last decade the antibody fragment indicated as nanobody (VHH or single domain antibody) has found its way to different applications previously done with conventional antibodies. Nanobodies can be selected to bind with high affinity and specificity to different antigens. They are small (molecular weight ca. 15kDa) and are usually easy to produce in microorganisms. Here we have evaluated the feasibility of a nanobody binding to HER2 for application in immuno-electron microscopy. To obtain highest labeling efficiency combined with optimal specificity, different labeling conditions were analysed, which included nanobody concentration, fixation and blocking conditions. The obtained optimal protocol was applied for post-embedment labeling of Tokuyasu cryosections and for pre-embedment labeling of HER2 for fluorescence microscopy and both transmission and scanning electron microscopy. We show that formaldehyde fixation after incubation with the anti-HER2 nanobody, improves labeling intensity. Among all tested blocking agents the best results were obtained with a mixture of cold water fish gelatine and acetylated bovine serum albumin, which prevented a-specific interactions causing background labeling while preserving specific interactions at the same time. In conclusion, we have developed a nanobody-based protocol for immuno-gold labeling of HER2 for Tokuyasu cryosections in TEM as well as for pre-embedment gold labeling of cells for both TEM and SEM.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Microscopia Imunoeletrônica/métodos , Receptor ErbB-2/análise , Anticorpos de Domínio Único/imunologia , Fixação de Tecidos/métodos , Animais , Ouro , Humanos , Microscopia Imunoeletrônica/normas , Receptor ErbB-2/imunologia , Projetos de Pesquisa , Coloração e Rotulagem/normas , Fixação de Tecidos/normas
3.
J Microsc ; 237(2): 208-20, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20096051

RESUMO

Aclar, a copolymer film with properties very similar to those of tissue culture plastic, is a versatile substrate to grow cells for light (including fluorescence) and electron microscopic applications in combination with both chemical fixation and cryoimmobilization. In this paper, we describe complete procedures to perform correlative light and electron microscopy using Aclar as substrate for the culture of cell monolayers to be finally embedded in plastic. First, we developed straightforward, efficient and flexible ways to mark the surface of the Aclar to create substrates to locate cells first at the light microscopy and then the electron microscopy level. All the methods enable the user to self-design gridded Aclar pieces, according to the purpose of the experiments, and create a large number of substrates in a short time. Second, we confirmed that marked Aclar supports the normal growth and morphology of cells. Third, we validated the correlative light and electron microscopy procedure using Aclar. This validation was done for the high-resolution analysis of endothelial cells using transmission electron microscopy and focused ion beam-scanning electron microscopy in combination with the use of fluorescence, phase contrast and/or bright field microscopy to map areas of interest at low resolution. The methods that we present are diverse, easy to implement and highly reproducible, and emphasize the versatility of Aclar as a cell growth substrate for diverse microscopic applications.


Assuntos
Técnicas de Cultura de Células/métodos , Microscopia Eletrônica/métodos , Microscopia/métodos , Manejo de Espécimes/métodos , Células Cultivadas , Células Endoteliais/citologia , Humanos
4.
Cell Mol Life Sci ; 67(2): 277-90, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19844658

RESUMO

Transplantation of human embryonic stem cell-derived cardiomyocytes (hESC-CM) for cardiac regeneration is hampered by the formation of fibrotic tissue around the grafts, preventing electrophysiological coupling. Investigating this process, we found that: (1) beating hESC-CM in vitro are embedded in collagens, laminin and fibronectin, which they bind via appropriate integrins; (2) after transplantation into the mouse heart, hESC-CM continue to secrete collagen IV, XVIII and fibronectin; (3) integrin expression on hESC-CM largely matches the matrix type they encounter or secrete in vivo; (4) co-transplantation of hESC-derived endothelial cells and/or cardiac progenitors with hESC-CM results in the formation of functional capillaries; and (5) transplanted hESC-CM survive and mature in vivo for at least 24 weeks. These results form the basis of future developments aiming to reduce the adverse fibrotic reaction that currently complicates cell-based therapies for cardiac disease, and to provide an additional clue towards successful engraftment of cardiomyocytes by co-transplanting endothelial cells.


Assuntos
Células-Tronco Embrionárias/fisiologia , Matriz Extracelular/metabolismo , Miócitos Cardíacos/transplante , Neovascularização Fisiológica , Animais , Diferenciação Celular , Linhagem Celular , Humanos , Camundongos , Miócitos Cardíacos/citologia
5.
J Struct Biol ; 159(3): 381-91, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17600727

RESUMO

Transmission electron tomography has been used in biological sciences for quite some time and proven to be a valuable tool. However, to date, the different Scanning Transmission modes are almost not used for electron tomography on resin-embedded biological material. We explored different STEM modes on epon-embedded, osmium-uranyl-lead-stained biological material. Bright Field-TEM and High Angle Annular Dark Field-STEM tomograms from the same areas were recorded and compared. Contrast and signal-to-noise ratios were calculated. Template matching was used to validate results obtained in Bright Field-TEM and High Angle Annular Dark Field-STEM tomograms. It is concluded that High Angle Annular Dark Field-STEM gives a five times better contrast and signal-to-noise ratio than Bright Field-TEM. Template matching showed that 1.3 times more information could be extracted from High Angle Annular Dark Field-STEM tomograms than from Bright Field-TEM tomograms.


Assuntos
Células/ultraestrutura , Microscopia Eletrônica de Transmissão e Varredura/métodos , Membrana Celular/ultraestrutura , Humanos
6.
Arch Environ Contam Toxicol ; 19(5): 691-8, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-21318500

RESUMO

An ultrastructural study was made of the renal system of freshwater clams,Anodonta cygnea, that had been exposed to cadmium chloride (50 µg Cd/L) for 12 weeks. By stereological analysis an extended lysosomal system and a decreased number of mitochondria was apparent in the epithelial cells lining the proximal compartment of the kidney. The increase of the lysosomal system was mainly accountable to the appearance of a distinct type of lysosome, that accumulated in the apical cell region. The decrease of the mitochondrial population was accompanied by a considerable swelling of the individual mitochondria. Finally, a severe reduction of the glycogen stores was noticed. Similar, but less obvious, changes occurred in the distal kidney compartment. The results suggest that long-term exposure ofAnodonta cygnea to cadmium stimulates the lysosomal system and disturbs the function of organelles involved in the energy metabolism of resorptive kidney cells.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...