Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
J Mech Behav Biomed Mater ; 13: 93-101, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22842280

RESUMO

Osteosynthesis plates are clinically used to fixate and position a fractured bone. They should have the ability to withstand cyclic loads produced by muscle contractions and total body weight. The very high demand for osteosynthesis plates in developing countries in general and in Indonesia in particular necessitates the utilisation of local products. In this paper, we investigated the mechanical properties, i.e. proportional limit and fatigue strength of Indonesian-made Narrow Dynamic Compression Plates (Narrow DCP) as one of the most frequently used osteosynthesis plates, in comparison to the European AO standard plate, and its relationship to geometry, micro structural features and surface defects of the plates. All Indonesian-made plates appeared to be weaker than the standard Narrow DCP because they consistently failed at lower stresses. Surface defects did not play a major role in this, although the polishing of the Indonesian Narrow DCP was found to be poor. The standard plate showed indications of cold deformation from the production process in contrast to the Indonesian plates, which might be the first reason for the differences in strength. This is confirmed by hardness measurements. A second reason could be the use of an inferior version of stainless steel. The Indonesian plates showed lower mechanical behaviour compared to the AO-plates. These findings could initiate the development of improved Indonesian manufactured DCP-plates with properties comparable to commonly used plates, such as the standard European AO-plates.


Assuntos
Placas Ósseas , Força Compressiva , Teste de Materiais , Testes de Dureza , Indonésia , Metais/química , Propriedades de Superfície
2.
Med J Malaysia ; 63 Suppl A: 21-2, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19024964

RESUMO

The enormous need of orthopaedic (surgical) implants such as osteosynthesis plates is difficult to be fulfilled in developing countries commonly rely on imported ones. One of the alternatives is utilization of local resources, but only after they have been proven safe to use, to overcome this problem. Surface properties are some of the determining factors of safety for those implants. We have succeeded in developing prototype of osteosynthesis plate and the results indicate that Indonesian-made plates need improvement with regards to the surface quality of physical characterization.


Assuntos
Placas Ósseas , Substitutos Ósseos , Teste de Materiais , Cerâmica , Materiais Revestidos Biocompatíveis , Força Compressiva , Humanos , Indonésia , Dispositivos de Fixação Ortopédica , Termogravimetria
4.
J Hosp Infect ; 62(2): 174-80, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16343691

RESUMO

The aim of this study was to evaluate whether behavioural and systemic measures will decrease intra-operative contamination during total hip or knee replacements. The influence of these measures on subsequent prolonged wound discharge, superficial surgical site infection and deep periprosthetic infection was also investigated during an 18-month follow-up period. Four swabs were taken from instruments at the beginning and end of the procedure for 207 procedures. Removed bone material (acetabulum and femur in case of the hip joint; femur and tibia in case of the knee joint) was also tested for contamination. Initially, 70 operations performed under original control conditions were included, after which the first behavioural measure was introduced (i.e. better use of the plenum). Cultures were taken during 67 operations using better use of the plenum (Group 1), followed by disciplinary measures and the installation of a new laminar flow system. Seventy operations were monitored after this second intervention (Group 2). The control group showed intra-operative contamination in 32.9% (23/70) of cases, Group 1 showed contamination in 34.3% (23/67) of cases and Group 2 showed contamination in 8.6% (6/70) of cases. Prolonged wound discharge and superficial surgical site infection decreased significantly in Group 2, as did the incidence of deep periprosthetic infection; however, the latter did not reach statistical significance. This study shows that the combination of systemic and behavioural changes in an operating room significantly decreases the incidence of intra-operative bacterial contamination, subsequent prolonged wound discharge and superficial surgical site infection. After 18 months of follow-up, there was also a decrease in deep periprosthetic infection.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Infecções Bacterianas/prevenção & controle , Controle de Infecções/métodos , Infecções Relacionadas à Prótese/prevenção & controle , Infecção da Ferida Cirúrgica/prevenção & controle , Artroplastia de Quadril/métodos , Artroplastia do Joelho/métodos , Infecções Bacterianas/microbiologia , Desinfecção/métodos , Prótese de Quadril/microbiologia , Humanos , Prótese do Joelho/microbiologia , Salas Cirúrgicas/normas , Infecções Relacionadas à Prótese/microbiologia , Infecção da Ferida Cirúrgica/microbiologia
5.
Med Phys ; 32(8): 2580-9, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16193788

RESUMO

The introduction of digital radiological facilities leads to the necessity of digital preoperative planning, which is an essential part of joint replacement surgery. To avoid errors in the preparation and execution of hip surgery, reliable correction of the magnification of the projected hip is a prerequisite. So far, no validated method exists to accomplish this. We present validated geometrical models of the x-ray projection of spheres, relevant for the calibration procedure to correct for the radiographic magnification. With help of these models a new calibration protocol was developed. The validity and precision of this procedure was determined in clinical practice. Magnification factors could be predicted with a maximal margin of error of 1.5%. The new calibration protocol is valid and reliable. The clinical tests revealed that correction of magnification has a 95% margin of error of -3% to +3%. Future research might clarify if a strict calibration protocol, as presented in this study, results in more accurate preoperative planning of hip joint replacements.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Cuidados Pré-Operatórios/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Calibragem , Humanos , Imageamento Tridimensional/métodos , Pelve/diagnóstico por imagem , Padrões de Prática Médica , Ajuste de Prótese/métodos , Intensificação de Imagem Radiográfica/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos
6.
J Appl Microbiol ; 99(3): 443-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16108785

RESUMO

AIMS: The aim of this study is to investigate whether pulsed ultrasound (US) in combination with gentamicin yields a decreased viability of bacteria in biofilms on bone cements in vivo. METHODS AND RESULTS: Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a rabbit model. Two bone cement samples with an Escherichia coli ATCC 10798 biofilm were implanted in a total of nine rabbits. In two groups bone cement discs loaded with gentamicin, freshly prepared and aged were used, and in one group unloaded bone cement discs in combination with systemically administered gentamicin. Pulsed ultrasound with a frequency of 28.48 kHz and a maximum acoustic intensity of 500 mW cm(-2) was applied continuously from 24 h till 72 h postsurgery on one of the two implanted discs. After euthanization and removal of the bacteria from the discs, the number of viable bacteria were quantified and skin samples were analysed for histopathological examination. Application of ultrasound, combined with gentamicin, reduced the viability of the biofilms in all three groups varying between 58 and 69% compared with the negative control. Histopathological examinations showed no skin lesions. CONCLUSIONS: Ultrasound resulted in a tendency of improved efficacy of gentamicin, either applied locally or systemically. Usage of ultrasound in this model proved to be safe. SIGNIFICANCE AND IMPACT OF THE STUDY: This study implies that ultrasound could improve the prevention of infection immediately after surgery, especially because the biomaterials, gentamicin and ultrasound used in this model are all in clinical usage, but not yet combined in clinical practice.


Assuntos
Antibacterianos/farmacologia , Biofilmes/crescimento & desenvolvimento , Cimentos Ósseos , Escherichia coli/crescimento & desenvolvimento , Gentamicinas/farmacologia , Ultrassom , Animais , Contagem de Colônia Microbiana , Escherichia coli/efeitos dos fármacos , Feminino , Modelos Animais , Coelhos , Pele/patologia
7.
J Bone Joint Surg Br ; 87(2): 272-6, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15736756

RESUMO

Clinical experience indicates the beneficial effects of antibiotic-loaded bone cement. Although in vitro studies have shown the formation of a biofilm on its surface they have not considered the gap between the cement and the bone. We have investigated bacterial survival in that gap. Samples with gaps 200 microm wide were made of different bone cements. These were stored dry ('pre-elution') or submersed in phosphate-buffered saline to simulate the initial release of gentamicin ('post-elution'). The gaps were subsequently inoculated with bacteria, which had been isolated from infected orthopaedic prostheses and assessed for their sensitivity to gentamicin. Bacterial survival was measured 24 hours after inoculation. All the strains survived in plain cements. In the pre-elution gentamicin-loaded cements only the most gentamicin-resistant strain, CN5115, survived, but in post-elution samples more strains did so, depending on the cement tested. Although high concentrations of gentamicin were demonstrated in the gaps only the gentamicin-sensitive strains were killed. This could explain the increased prevalence of gentamicin-resistant infections which are seen clinically.


Assuntos
Antibacterianos/uso terapêutico , Bactérias/efeitos dos fármacos , Cimentos Ósseos , Gentamicinas/uso terapêutico , Biofilmes , Contagem de Colônia Microbiana , Relação Dose-Resposta a Droga , Farmacorresistência Bacteriana , Humanos , Infecções Relacionadas à Prótese/microbiologia , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus/efeitos dos fármacos
8.
Transfus Med ; 15(1): 13-8, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15713124

RESUMO

Although blood transfusion has never been safer, there remains concern about adverse effects. We designed guidelines, the 6-8-10-Flexinorm, based on the conditions which are relevant to the decision to transfuse. To evaluate these new guidelines, we performed a case-control study in patients undergoing elective primary total hip replacement. The study consisted of two parts. In the first part, physicians were strongly encouraged to use the new guidelines; in the second part, only registration took place. During the first and second part of the study, the use of packed red cells (PRC) in Hospital A (study hospital) decreased from 1.1 +/- 1.5 to 0.6 +/- 1.2 and 0.3 +/- 0.9 units, whereas in Hospital B (control), the use of PRC remained unchanged (1 +/- 1.5, 1 +/- 1.7 and 1 +/- 2 units). In the prestudy groups, 43% of the patients in Hospital A were transfused compared to 45% in Hospital B. In the first and second part of the study, 27%, respectively, 14% of the patients in Hospital A were transfused compared to 40% in both periods in Hospital B. The new guidelines lead to a reduction in the use of allogeneic blood and a decrease in the number of patients transfused.


Assuntos
Artroplastia de Quadril , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue Autóloga , Transfusão de Eritrócitos , Guias de Prática Clínica como Assunto , Idoso , Artroplastia de Quadril/normas , Transfusão de Sangue Autóloga/normas , Procedimentos Cirúrgicos Eletivos/normas , Transfusão de Eritrócitos/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto/normas
9.
Int J Tuberc Lung Dis ; 8(11): 1368-72, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15581207

RESUMO

SETTING: Tuberculosis Centre, University Medical Centre, Groningen, The Netherlands. OBJECTIVES: To study intralesional concentrations of isoniazid (INH), rifampicin (RMP) and pyrazinamide (PZA) in tuberculous pleural effusions and psoas abscesses, and to compare these to reference serum values and minimal inhibitory concentration (MIC). DESIGN: Intralesional concentrations were measured 2 h after drug administration (six pleural effusions, 10 psoas abscesses). RESULTS: A wide range of concentrations was found for pleural effusions and psoas abscesses. Concentrations were below MIC values in none of 15 patients for INH, in two of 13 for RMP, and in eight of nine for PZA. The Cmax:MIC ratio was always >4 for INH, in four of 13 for RMP, and in none of nine for PZA. In 5/8 patients receiving all three drugs, both RMP and PZA had Cmax:MIC ratios <4, indicating sub-therapeutic drug levels. CONCLUSION: Penetration of INH was always sufficient, penetration of RMP mostly below the desired ratio, and for PZA on average 10 times too low. Five of eight patients on all three drugs had Cmax:MIC ratios <4. This indicates intralesional sub-therapeutic drug levels for RMP and PZA, and local monotherapy with INH. This could induce drug resistance. Drainage as additional therapy seems indicated.


Assuntos
Antituberculosos/farmacocinética , Isoniazida/farmacocinética , Derrame Pleural/metabolismo , Abscesso do Psoas/metabolismo , Pirazinamida/farmacocinética , Rifampina/farmacocinética , Adolescente , Adulto , Idoso , Antituberculosos/uso terapêutico , Feminino , Humanos , Isoniazida/uso terapêutico , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Países Baixos , Derrame Pleural/complicações , Abscesso do Psoas/complicações , Pirazinamida/uso terapêutico , Rifampina/uso terapêutico , Tuberculose Pulmonar/complicações , Tuberculose Pulmonar/tratamento farmacológico , Adulto Jovem
10.
Ned Tijdschr Geneeskd ; 148(40): 1960-5, 2004 Oct 02.
Artigo em Holandês | MEDLINE | ID: mdl-15524130

RESUMO

The function and survival time of unicompartmental knee prostheses for patients with severe gonarthrosis have been improved the past few years by developments in their design, the instrumentarium and the surgical technique. A medial unicompartmental knee prosthesis may be indicated in patients with arthrosis of the medial tibiofemoral compartment. The prerequisites are an intact anterior cruciate ligament, an intact lateral compartment, a correctable varus axis and sufficient flexion in the knee. Contraindications are inflammatory arthropathies and a recent episode of septic arthritis. Relative contraindications are: old age, excess body weight, patellofemoral arthrosis and chondrocalcinosis. A unicompartmental knee prosthesis can be placed via a small parapatellar incision. The postoperative recovery is more rapid than following the classical open approach, while the knee function after 5 years is comparable. The knee function also seems better following a medial unicompartmental knee prosthesis than after valgusising tibial head osteotomy. The latter is still preferred for young active patients. Medial unicompartmental knee prostheses fail in 6-8% of patients. Revision to a total knee prosthesis is then the treatment of choice. In the long term, unicompartmental prostheses with a mobile bearing become loose less often than comparable prostheses with a fixed bearing.


Assuntos
Artroplastia do Joelho , Artropatias/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Fenômenos Biomecânicos , Humanos , Artropatias/patologia , Articulação do Joelho/patologia , Satisfação do Paciente , Falha de Prótese , Resultado do Tratamento , Suporte de Carga/fisiologia
11.
Ned Tijdschr Geneeskd ; 148(35): 1732-8, 2004 Aug 28.
Artigo em Holandês | MEDLINE | ID: mdl-15468904

RESUMO

In three male patients with hereditary multiple exostoses (HME), aged 50, 29 and 31 years, peripheral low-grade chondrosarcoma in the pelvic region led to swelling or pain. In the first patient, curative resection was not feasible because of the size and extension of the tumour. However, rapid tumour growth and unbearable pain necessitated a debulking procedure 16 months later. Histopathologic examination revealed a highly malignant dedifferentiated chondrosarcoma. The patient died two years after initial presentation as a result of local tumour growth. In the second patient, treatment consisted of wide resection of the tumour. Five years after the surgery the patient was free of disease. The third patient was initially treated by intralesional resection, followed by partial hemipelvectomy because of residual tumour. Thirteen months later, a local recurrence occurred that was treated by wide excision. Four years after the partial hemipelvectomy the patient was both pain-free and disease-free. Patients with HME are at increased risk for malignant degeneration of pelvic osteochondroma to chondrosarcoma. Periodic control of patients with pelvic osteochondromas is advised, preferably once every two years.


Assuntos
Neoplasias Ósseas/etiologia , Condrossarcoma/etiologia , Exostose Múltipla Hereditária/complicações , Ossos Pélvicos , Adulto , Neoplasias Ósseas/genética , Neoplasias Ósseas/cirurgia , Condrossarcoma/genética , Condrossarcoma/cirurgia , Exostose Múltipla Hereditária/genética , Exostose Múltipla Hereditária/cirurgia , Evolução Fatal , Hemipelvectomia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Dor/etiologia , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/patologia , Ossos Pélvicos/cirurgia , Radiografia , Resultado do Tratamento
12.
J Bone Joint Surg Br ; 86(6): 901-4, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15330034

RESUMO

There has been an increase in the incidence of bone and joint tuberculosis (BJTB) in The Netherlands and we have carried out an epidemiological study in order to find an explanation for this increase. Data from 1993 to 2000 from The Netherlands Tuberculosis Register (NTR) were used. In 1993 there was a total of 52 patients with BJTB. This figure increased gradually to 80 in 1999 before decreasing to 61 in 2000. There was a total of 12447 patients with tuberculosis; BJTB was found in 532, accounting for 4.3% of all cases and 10.6% of all extrapulmonary cases. Localisation in the spine occurred in 56%. Certain immigrants, in particular from Somalia, were more likely to have BJTB than other immigrants or the native Dutch population. Increased age and female gender were associated with BJTB. Only 15% of BJTB patients also suffered from pulmonary tuberculosis. The usual long delay in the diagnosis of BJTB may be shortened if physicians are more aware of tuberculosis.


Assuntos
Tuberculose Osteoarticular/epidemiologia , Adulto , África/etnologia , Idoso , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Fatores de Tempo , Tuberculose Osteoarticular/diagnóstico , Tuberculose Osteoarticular/etnologia , Turquia/etnologia
14.
Biomaterials ; 25(3): 545-56, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14585704

RESUMO

Antibiotic-loaded bone cement has been in use for over 30 years for the fixation of total joint arthroplasties, although its mechanism of action is still poorly understood. This review presents the backgrounds of bone cements, prosthesis-related infection and antibiotic-loaded bone cements. It is shown that antibiotic-loaded bone cement has a significant effect on bacteria, particularly in animal and clinical studies. However, recently, antimicrobial resistance among bacteria has been ascribed to the antibiotic-loaded bone cement. The unresolved issues both regarding the action of antibiotic-loaded bone cement and the nature of the antimicrobial resistance necessitate further research into the interaction of antibiotic-loaded bone cement and bacteria.


Assuntos
Antibacterianos/farmacologia , Cimentos Ósseos/química , Prótese de Quadril , Implantação de Prótese , Infecções Relacionadas à Prótese , Animais , Materiais Biocompatíveis/química , Cimentos Ósseos/farmacologia , Ensaios Clínicos como Assunto , Humanos , Infecções , Polimetil Metacrilato/química , Próteses e Implantes
15.
J Bone Joint Surg Br ; 85(6): 836-40, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12931801

RESUMO

We studied retrospectively the outcome of patellofemoral arthroplasty (PFA) using the Richards prosthesis in 51 patients (56 knees). Their mean age was 50 years (30 to 77). In 43 patients (45 knees), the American Knee Society score and the patients' subjective judgement were assessed. Excellent or good results were obtained in 86% of cases at a mean follow-up of 17 years (15 to 21). Because of ongoing tibiofemoral osteoarthritis, two patients required a high tibial osteotomy and ten PFAs were converted to a total knee arthroplasty after a mean of 15.6 years (10 to 21). The PFAs were stable during follow-up with a loosening rate of only 2%. We conclude that a patellofemoral prosthesis is a good treatment option with successful long-term results in middle-aged patients with radiologically documented, isolated, patellofemoral osteoarthritis.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Adulto , Idoso , Artroplastia do Joelho/instrumentação , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Radiografia , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
Am J Med Genet A ; 120A(4): 490-7, 2003 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-12884427

RESUMO

In this study, we followed-up the family with bilateral hereditary micro-epiphyseal dysplasia (BHMED) originally described by Elsbach [1959: J Bone Joint Surg [Br] 41-B:514-523]. Clinical re-examination of all available family members resulted in further delineation of the clinical and radiological phenotype, which is distinct from common multiple epiphyseal dysplasia (MED). Linkage analysis excluded EDM1, EDM2, and EDM3 as candidate genes. Linkage and mutation analysis of matrilin-3 (MATN-3) revealed a new pathogenic mutation confirming that BHMED is indeed a distinct disease entity among MED and MED-like disorders.


Assuntos
Proteínas da Matriz Extracelular/genética , Osteocondrodisplasias/genética , Adolescente , Adulto , Sequência de Aminoácidos , Estudos de Casos e Controles , Criança , Pré-Escolar , Análise Mutacional de DNA , Feminino , Seguimentos , Humanos , Masculino , Proteínas Matrilinas , Pessoa de Meia-Idade , Mutação , Osteocondrodisplasias/diagnóstico por imagem , Linhagem , Fenótipo , Radiografia , Alinhamento de Sequência
17.
Acta Orthop Belg ; 69(2): 175-81, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12769019

RESUMO

The use of biodegradable fixation devices in the operative treatment of osteochondritis dissecans of the knee could avoid a second operation for removal of the hardware, but what are the disadvantages? Seven osteochondritis dissecans lesions, non-displaced in four adult knees and in one adolescent knee and displaced in two knees of adolescents, were treated by drilling and stabilisation with biodegradable pins, resulting in primary consolidation in the five non-displaced lesions and failure in the two detached lesions. However, two detached fragments in adults, primarily fixed with one metallic compression screw and three biodegradable pins both consolidated. In another adult patient, the fixation with two compression screws failed. A study of the available literature and the results of our limited experience seem to indicate that the primary operative treatment of choice of a non-detached osteochondritis dissecans lesion is drilling and fixation with biodegradable pins. However, if this regimen fails or in patients with a detached lesion, one metallic screw and a few additional biodegradable pins appear to constitute the best method of fixation. The use of biodegradable screws is still hazardous, because of the long degradation time and subsequent risk of erosion of the opposite cartilage and tissue reaction. Other resurfacing options are available for failures or fragmented or non-vital lesions.


Assuntos
Implantes Absorvíveis , Pinos Ortopédicos , Parafusos Ósseos , Articulação do Joelho/cirurgia , Osteocondrite Dissecante/cirurgia , Adolescente , Adulto , Feminino , Fêmur/cirurgia , Humanos , Masculino , Cicatrização
18.
Rofo ; 174(7): 887-92, 2002 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-12101480

RESUMO

AIM: To prove that bilateral hereditary micro-epiphyseal dysplasia (BHMED), first described by Elsbach in 1959, is a distinct disorder radiologically as well as clinically, compared with multiple epiphyseal dysplasia (MED). MATERIAL AND METHODS: We used the data of the revised pedigree with 84 family members, performed a medical history, physical examination and made a radiological evaluation for defining a clinical and radiological phenotype of BHMED family members. We used blood samples for genetic analysis. RESULTS: Although there is a clear clinical picture of the dysplasia, the radiological signs are more reliable for making the diagnosis. Especially the typical deformity of the hip and knee joint are diagnostic for BHMED. By linkage analysis we excluded linkage with the three known MED-loci (EDM1, EDM2 and EDM3). CONCLUSION: BHMED is indeed an entity that is distinct from common multiple epiphyseal dysplasia (MED), clinically, as well as radiologically and genetically.


Assuntos
Osteocondrodisplasias/diagnóstico por imagem , Adulto , Idoso , Osso e Ossos/diagnóstico por imagem , Aberrações Cromossômicas , Feminino , Genes Dominantes/genética , Predisposição Genética para Doença/genética , Humanos , Masculino , Pessoa de Meia-Idade , Osteocondrodisplasias/genética , Linhagem , Fenótipo , Radiografia , Reprodutibilidade dos Testes
19.
Int Orthop ; 26(3): 188-93, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12073115

RESUMO

Bilateral hereditary micro-epiphyseal dysplasia (BHMED) is a distinct skeletal dysplasia with specific clinical and radiological findings. It was first published in 1959. We have re-examined the original family for further delineation of the phenotype.


Assuntos
Osteocondrodisplasias/genética , Fenótipo , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteocondrodisplasias/diagnóstico por imagem , Linhagem , Radiografia , Fatores de Tempo
20.
Int J Artif Organs ; 25(4): 327-33, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12027144

RESUMO

The fixation of an artificial intervertebral disc has been studied especially with respect to the dimensions, the convexity of the endplates and the size of the fixation elements. From literature and cadaveric vertebrae, the dimensions and shape of the lumbar vertebral endplates were determined and the dimensions of fixation ribs for the artificial intervertebral disc were calculated. To withstand shear forces and prevent dislocation, two sagittal ribs, each 3.5 mm in height and at least 20 mm in length and four transversal ribs, each 1.5 mm in height and with a total length of 60 mm are sufficient. A range of five different sagittal diameters was selected as sufficient for all patients. At least 72.6 % of the endplate of the vertebrae is covered. A convexity with a radius of 140 mm limits the gap to 0.62 mm.


Assuntos
Disco Intervertebral/cirurgia , Vértebras Lombares , Próteses e Implantes , Fenômenos Biomecânicos , Humanos , Técnicas In Vitro , Vértebras Lombares/anatomia & histologia , Desenho de Prótese , Implantação de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...