1.
Acta Oncol ; 62(7): 753-764, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37010899

RESUMO

Background: Supporting unemployed or work-disabled cancer survivors in their work participation can have extensive individual and societal benefits. We aimed to identify and summarise interventions for work participation of unemployed or work-disabled cancer survivors.Methods: Five databases (Medline, Embase, PsycINFO, CINAHL and Cochrane Library) were systematically searched for quantitative studies on interventions aimed at enhancing work participation of unemployed or work-disabled cancer survivors. Work participation refers to participation in the workforce, fulfilling one's work role. Manual and automatic screening (with ASReview software) were performed on titles and abstracts, followed by manual full-text screening. Data were extracted regarding study, patient and intervention characteristics, and work participation outcomes. Risk of bias (RoB) was assessed using the Cochrane RoB2 and QUIPS tools.Results: We identified 10,771 articles, of which we included two randomised controlled trials (RCTs), of which one feasibility RCT, and three cohort studies. In total, 1862 cancer survivors were included, with predominantly breast cancer. Work participation was mainly measured as time to return to work (RTW) and RTW rate. Interventions included components of coaching (e.g., psychological or rehabilitation), training (e.g., building confidence and managing fatigue) and self-management. Two RCTs with unclear RoB did not show an effect of multicomponent interventions compared to care as usual. One cohort study found a significant effect of a psycho-educational intervention on RTW rates, with moderate RoB. The other two cohort studies, with moderate RoB, reported significant associations between components including job search and placement assistance, and work participation.Discussion: Only few interventions aimed at enhancing work participation of unemployed or work-disabled cancer survivors, have been evaluated. In two cohort studies, promising components for future multicomponent interventions were identified. However, findings suggest that more evidence is necessary on such multicomponent interventions, in which elements explicitly directed at work and including the workplace should be included.


Assuntos
Neoplasias da Mama , Sobreviventes de Câncer , Humanos , Feminino , Neoplasias da Mama/reabilitação , Retorno ao Trabalho
2.
AJNR Am J Neuroradiol ; 43(9): 1259-1264, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35953275

RESUMO

BACKGROUND AND PURPOSE: Dual-energy virtual NCCT has the potential to replace conventional NCCT to detect early ischemic changes in acute ischemic stroke. In this study, we evaluated whether virtual NCCT is noninferior compared with standard linearly blended NCCT, a surrogate of conventional NCCT, regarding the detection of early ischemic changes with ASPECTS. MATERIALS AND METHODS: Adult patients who presented with suspected acute ischemic stroke and who underwent dual-energy NCCT and CTA and brain MR imaging within 48 hours were included. Standard linearly blended images were reconstructed to match a conventional NCCT. Virtual NCCT images were reconstructed from CTA. ASPECTS was evaluated on conventional NCCT, virtual NCCT, and DWI, which served as the reference standard. Agreement between CT assessments and the reference standard was evaluated with the Lin concordance correlation coefficient. Noninferiority was assessed with bootstrapped estimates of the differences in ASPECTS between conventional and virtual NCCT with 95% CIs. RESULTS: Of the 193 included patients, 100 patients (52%) had ischemia on DWI. Compared with the reference standard, the ASPECTS concordance correlation coefficient for conventional and virtual NCCT was 0.23 (95% CI, 0.15-0.32) and 0.44 (95% CI, 0.33-0.53), respectively. The difference in the concordance correlation coefficient between virtual and conventional NCCT was 0.20 (95% CI, 0.01-0.39) and did not cross the prespecified noninferiority margin of -0.10. CONCLUSIONS: Dual-energy virtual NCCT is noninferior compared with conventional NCCT for the detection of early ischemic changes with ASPECTS.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Adulto , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia Cerebral/métodos , Encéfalo , Isquemia Encefálica/diagnóstico por imagem
3.
Eur J Radiol ; 112: 65-71, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30777221

RESUMO

PURPOSE: To assess the radiation dose associated with always-on dual-energy acquisitions in clinical practice over a broad range of clinical protocols using a dual-layer detector CT (DLCT; IQon spectral CT, Philips Healthcare) as compared to an otherwise technically equivalent single-layer detector CT (SLCT; Brilliance iCT, Philips healthcare). MATERIALS AND METHODS: Dose-length-product data for consecutive examinations over a six-month period acquired with DLCT were retrospectively collected and compared to consecutive examinations from an SLCT. Imaging protocols were optimized for diagnostic image quality for each system prior to data collection. Dose reports of CT protocols that were used at least 50 times on both systems were collected. After exclusion of statistical outliers, protocols were evaluated with regard to reported dose levels. RESULTS: In total, 4536 dose reports for DLCT and 5783 reports for SLCT were collected. All DLCT examinations were acquired at 120 kVp, enabling dual-energy analysis. With SLCT, 79% of examinations were acquired at 120 kVp, and 21% at 100/80 kVp. Protocols for 15 indications were used more than 50 times on both scanners. For seven protocols there was no significant difference between the two scanners (p > 0.05), whereas seven protocols were acquired with higher dose levels on SLCT compared to the DLCT (p < 0.03). For one protocol, the DLCT dose was significantly higher (p < 0.005) compared to the SLCT. CONCLUSION: Dual-layer detector CT enables acquisition of dual-energy information over a broad range of clinical indications without increasing radiation dose when compared to a conventional single-layer detector CT.


Assuntos
Tomógrafos Computadorizados/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Abdome/efeitos da radiação , Encéfalo/efeitos da radiação , Cabeça/efeitos da radiação , Coração/efeitos da radiação , Humanos , Pescoço/efeitos da radiação , Imagens de Fantasmas , Doses de Radiação , Estudos Retrospectivos , Tórax/efeitos da radiação , Tomografia Computadorizada por Raios X/métodos
4.
Med Phys ; 43(10): 5442, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27782702

RESUMO

PURPOSE: Hyperthermia is an established (neo)adjuvant treatment modality for a number of pelvic malignancies. Optimal treatment of these tumors requires robust treatment planning, but up until now, the urinary bladder was not modeled accurately, making current simulations less reliable. The authors improved the dielectric and thermophysical model of the urinary bladder in their treatment planning system, and showed the improvements using phantom experiments. METHODS: The authors suspended a porcine bladder in muscle tissue equivalent gel and filled it with 120 ml 0.9% saline. The authors heated the phantom during 15 min with their deep hyperthermia device, using clinical settings, and measured the temperature both inside and outside the bladder. The authors simulated the experiment, both using the clinically used treatment planning system, and using the improved model featuring correct dielectric properties for the bladder content and an enhanced thermophysical model, enabling the simulation of convection. RESULTS: Although the dielectric changes have an impact throughout the phantom, the dominant effect is a higher net heat absorption in the bladder. The effects of changing the thermophysical model are limited to the bladder and its surroundings, but result in a very different temperature profile. The temperatures predicted by the simulations using the new bladder model were in much better agreement with the measurements than those predicted by currently used treatment planning system. CONCLUSIONS: Modeling convection in the urinary bladder is very important for accurate hyperthermia treatment planning in the pelvic area.


Assuntos
Hipertermia Induzida/métodos , Pelve , Imagens de Fantasmas , Animais , Neoplasias Pélvicas/terapia , Suínos , Bexiga Urinária