Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Comput Biol Med ; 142: 105191, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35026571

RESUMO

Automatic cardiac chamber and left ventricular (LV) myocardium segmentation over the cardiac cycle significantly extends the utilization of contrast-enhanced cardiac CT, potentially enabling in-depth assessment of cardiac function. Therefore, we evaluate an automatic method for cardiac chamber and LV myocardium segmentation in 4D cardiac CT. In this study, 4D contrast-enhanced cardiac CT scans of 1509 patients selected for transcatheter aortic valve implantation with 21,605 3D images, were divided into development (N = 12) and test set (N = 1497). 3D convolutional neural networks were trained with end-systolic (ES) and end-diastolic (ED) images. Dice similarity coefficient (DSC) and average symmetric surface distance (ASSD) were computed for 3D segmentations at ES and ED in the development set via cross-validation, and for 2D segmentations in four cardiac phases for 81 test set patients. Segmentation quality in the full test set of 1497 patients was assessed visually on a three-point scale per structure based on estimated overlap with the ground truth. Automatic segmentation resulted in a mean DSC of 0.89 ± 0.10 and ASSD of 1.43 ± 1.45 mm in 12 patients in 3D, and a DSC of 0.89 ± 0.08 and ASSD of 1.86 ± 1.20 mm in 81 patients in 2D. The qualitative evaluation in the whole test set of 1497 patients showed that automatic segmentations were assigned grade 1 (clinically useful) in 98.5%, 92.2%, 83.1%, 96.3%, and 91.6% of cases for LV cavity and myocardium, right ventricle, left atrium, and right atrium. Our automatic method using convolutional neural networks performed clinically useful segmentation across the cardiac cycle in a large set of 4D cardiac CT images, potentially enabling in-depth assessment of cardiac function.


Assuntos
Aprendizado Profundo , Tomografia Computadorizada Quadridimensional , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação
2.
Eur Radiol ; 32(1): 143-151, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34132873

RESUMO

OBJECTIVES: Computed tomography angiography (CTA) is performed routinely in the work-up for transcatheter aortic valve implantation (TAVI), and could potentially replace invasive coronary angiography (ICA) to rule out left main (LM) and proximal coronary stenosis. The objectives were to assess the diagnostic yield and accuracy of pre-TAVI CTA to detect LM and proximal coronary stenosis of ≥ 50% and ≥ 70% diameter stenosis (DS). METHODS: The DEPICT CTA database consists of individual patient data from four studies with a retrospective design that analyzed the diagnostic accuracy of pre-TAVI CTA to detect coronary stenosis, as compared with ICA. Pooled data were used to assess diagnostic accuracy to detect coronary stenosis in the left main and the three proximal coronary segments on a per-patient and a per-segment level. We included 1060 patients (mean age: 81.5 years, 42.7% male). RESULTS: On ICA, the prevalence of proximal stenosis was 29.0% (≥ 50% DS) and 15.7% (≥ 70% DS). Pre-TAVI CTA ruled out ≥ 50% DS in 51.6% of patients with a sensitivity of 96.4%, specificity of 71.2%, PPV of 57.7%, and NPV of 98.0%. For ≥ 70% DS, pre-TAVI CTA ruled out stenosis in 70.0% of patients with a sensitivity of 96.7%, specificity of 87.5%, PPV of 66.9%, and NPV of 99.0%. CONCLUSION: CTA provides high diagnostic accuracy to rule out LM and proximal coronary stenosis in patients undergoing work-up for TAVI. Clinical application of CTA as a gatekeeper for ICA would reduce the need for ICA in 52% or 70% of patients, using a threshold of ≥ 50% or ≥ 70% DS, respectively. KEY POINTS: • Clinical application of CTA as a gatekeeper for ICA would reduce the need for ICA in 52% or 70% of TAVI patients, using a threshold of ≥ 50% or ≥ 70% diameter stenosis. • The diagnostic accuracy of CTA to exclude proximal coronary stenosis in these patients is high, with a sensitivity of 96.4% and NPV of 98.0% for a threshold of ≥ 50%, and a sensitivity of 96.7% and NPV of 99.0% for a threshold of ≥ 70% diameter stenosis. • Atrial fibrillation and heart rate did not significantly affect sensitivity and NPV. However, a heart rate of < 70 b/min during CTA was associated with a significantly improved specificity and PPV.


Assuntos
Estenose da Valva Aórtica , Estenose Coronária , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Estudos Retrospectivos
3.
J Invasive Cardiol ; 33(10): E823-E832, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34609327

RESUMO

OBJECTIVES: To analyze the effect of percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) on all-cause and cardiovascular mortality after TAVR, differentiating between significant proximal lesions and the non-proximal (residual) lesions. METHODS: An institutional TAVR database was complemented with data on the extent of coronary artery disease (CAD), lesion location, lesion severity, and the location of PCI. Survival analysis was performed to investigate the impact on 6-month and 3-year mortality after TAVR in all patients and in subgroups of patients with significant proximal lesions (>70% diameter stenosis [DS], >50% DS in left main), the non-proximal residual lesions, and in a propensity score matched cohort. RESULTS: Among the 577 included patients, mean age was 83 years, 50% were female, and 31% had diabetes mellitus. Preprocedural PCI of unselected lesions was independently associated with increased 6-month mortality (hazard ratio, 2.2; 95% confidence interval, 1.0-4.6; P=.04), but selective PCI of significant proximal lesions did not have an association with higher mortality, nor did we find a significant effect of PCI on mortality in the propensity-matched cohort. CONCLUSION: Routine pre-TAVR PCI is not associated with mortality reduction in TAVR patients with coronary lesions in any segment or in patients with proximal coronary lesions. Despite the lack of a beneficial effect of routine pre-TAVR PCI, we cannot exclude a beneficial effect in a selection of patients with proximal lesions. Therefore, we strongly support the current clinical guidelines to only consider pre-TAVR PCI in proximal coronary lesions, while advocating a restrictive pre-TAVR PCI strategy.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
J Thorac Imaging ; 36(6): 353-359, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34269752

RESUMO

PURPOSE: The first objective of this study was to evaluate the efficacy of a patient-tailored contrast delivery protocol for coronary computed tomography angiography (CTCA), in terms of diagnostic coronary attenuation and total iodine load (TIL), by adjusting the iodine delivery rate (IDR) via dilution for body weight and tube voltage (kV), as compared with a protocol with a fixed bolus of contrast in a clinical setting. The secondary objective was to assess the association between the test-bolus data and luminal attenuation in CTCA. MATERIALS AND METHODS: Patients who underwent CTCA with fixed IDR contrast delivery (cohort 1) or with IDR adjusted for body weight and kV settings (70 to 120 kV) (cohort 2) were included, and compared for intravascular luminal attenuation and TIL. The association between intravascular luminal attenuation and test-bolus scan data was investigated with linear regression. RESULTS: In cohort 1 (176 patients), the mean luminal attenuation differed markedly between kV categories, whereas in cohort 2 (154 patients), there were no marked differences. The mean TIL reduced significantly (20.1±1.2 g in cohort 1, 17.7±3.0 g in cohort 2, P<0.001). The peak height of the test-bolus scan was independently associated with luminal attenuation in the ascending aorta, with a 0.58 HU increase per HU peak-height increase (SE=0.18, P<0.001). CONCLUSION: Clinical implementation of a patient-tailored contrast delivery protocol for CTCA, adjusted for body weight and kV, improves luminal attenuation and significantly reduces the TIL. The peak height of the test-bolus scan is associated with luminal attenuation in the ascending aorta in the CTCA scan.


Assuntos
Angiografia por Tomografia Computadorizada , Iodo , Meios de Contraste , Angiografia Coronária , Humanos , Tomografia Computadorizada por Raios X
5.
J Clin Med ; 10(11)2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34071249

RESUMO

To assess the need for additional invasive coronary angiography (CAG) after initial computed tomography coronary angiography (CTCA) in patients awaiting non-coronary cardiac surgery and in patients with cardiomyopathy, heart failure or ventricular arrhythmias, and to determine differences between patients that were referred to initial CTCA or direct CAG, consecutive patients were included between August 2017 and January 2020 and categorized as those referred to initial CTCA (conform protocol), and to direct CAG (non-conform protocol). Out of a total of 415 patients, 78.8% (327 patients, mean age: 57.9 years, 67.3% male) were referred to initial CTCA, of whom 260 patients (79.5%) had no obstructive lesions (<50% DS). A total of 55 patients (16.8%) underwent additional CAG after initial CTCA, which showed coronary lesions of >50% DS in 21 patients (6.3% of 327). Eighty-eight patients (mean age: 66.0 years, 59.1% male) were directly referred to CAG (non-conform protocol). These patients were older and had more cardiovascular risk factors compared to patients that underwent initial CTCA (conform protocol), and coronary lesions of >50% DS were detected in 16 patients (17.2%). Revascularization procedures were infrequently performed in both groups: initial CTCA (3.0%), direct CAG (3.4%). The use of CTCA as a gatekeeper CAG in the diagnostic work-up of non-coronary cardiac surgery, cardiomyopathy, heart failure and ventricular arrhythmias is feasible, and only 17% of these patients required additional CAG after initial CTCA. Therefore, CTCA should be considered as the initial imaging modality to rule out CAD in these patients.

6.
Circ Cardiovasc Interv ; 12(8): e007322, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31518164

RESUMO

BACKGROUND: In patients with stable coronary artery disease, the amount of myocardium subtended by coronary stenoses constitutes a major determinant of prognosis, as well as of the benefit of coronary revascularization. We devised a novel method to estimate partial myocardial mass (PMM; ie, the amount of myocardium subtended by a stenosis) during physiological stenosis interrogation. Subsequently, we validated the index against equivalent PMM values derived from applying the Voronoi algorithm on coronary computed tomography angiography. METHODS: Based on the myocardial metabolic demand and blood supply, PMM was calculated as follows: PMM (g)=APV×D2×π/(1.24×10-3×HR×sBP+1.6), where APV indicates average peak blood flow velocity; D, vessel diameter; HR, heart rate; and sBP, systolic blood pressure. We calculated PMM to 43 coronary vessels (32 patients) interrogated with pressure and Doppler guidewires, and compared it with computed tomography-based PMM. RESULTS: Median PMM was 15.8 g (Q1, Q3: 11.7, 28.4 g) for physiology-based PMM, and 17.0 g (Q1, Q3: 12.5, 25.9 g) for computed tomography-based PMM (P=0.84). Spearman rank correlation coefficient was 0.916 (P<0.001), and Passing-Bablok analysis revealed absence of both constant and proportional differences (coefficient A: -0.9; 95% CI, -4.5 to 0.9; and coefficient B, 1.00; 95% CI, 0.91 to 1.25]. Bland-Altman analysis documented a mean bias of 0.5 g (limit of agreement: -9.1 to 10.2 g). CONCLUSIONS: Physiology-based calculation of PMM in the catheterization laboratory is feasible and can be accurately performed as part of functional stenosis assessment.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Metabolismo Energético , Modelos Biológicos , Miocárdio/metabolismo , Idoso , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/metabolismo , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/metabolismo , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Países Baixos , Consumo de Oxigênio , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
7.
Int J Cardiovasc Imaging ; 35(11): 2123-2133, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31312998

RESUMO

Chronic silent brain infarctions, detected as new white matter hyperintensities on magnetic resonance imaging (MRI) following transcatheter aortic valve implantation (TAVI), are associated with long-term cognitive deterioration. This is the first study to investigate to which extent the calcification volume of the native aortic valve (AV) measured with cardiac computed tomography angiography (CTA) predicts the increase in chronic white matter hyperintensity volume after TAVI. A total of 36 patients (79 ± 5 years, median EuroSCORE II 1.9%, Q1-Q3 1.5-3.4%) with severe AV stenosis underwent fluid attenuation inversion recovery (FLAIR) MRI < 24 h prior to TAVI and at 3 months follow-up for assessment of cerebral white matter hyperintensity volume (mL). Calcification volumes (mm3) of the AV, aortic arch, landing zone and left ventricle were measured on the CTA pre-TAVI. The largest calcification volumes were found in the AV (median 692 mm3) and aortic arch (median 633 mm3), with a large variation between patients (Q1-Q3 482-1297 mm3 and 213-1727 mm3, respectively). The white matter hyperintensity volume increased in 72% of the patients. In these patients the median volume increase was of 1.1 mL (Q1-Q3 0.3-4.6 mL), corresponding with a 27% increase from baseline (Q1-Q3 7-104%). The calcification volume in the AV predicted the increase of white matter hyperintensity volume (Δ%), with a 35% increase of white matter hyperintensity volume, per 100 mm3 of AV calcification volume (SE 8.5, p < 0.001). The calcification volumes in the aortic arch, landing zone and left ventricle were not associated with the increase in white matter hyperintensity volume. In 72% of the patients new chronic white matter hyperintensities developed 3 months after TAVI, with a median increase of 27%. A higher calcification volume in the AV was associated with a larger increase in the white matter hyperintensity volume. These findings show the potential for automated AV calcium screening as an imaging biomarker to predict chronic silent brain infarctions.


Assuntos
Estenose da Valva Aórtica/cirurgia , Infarto Cerebral/etiologia , Leucoencefalopatias/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Doenças Assintomáticas , Infarto Cerebral/diagnóstico por imagem , Doença Crônica , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Feminino , Humanos , Leucoencefalopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
JACC Case Rep ; 1(2): 101-104, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34316759

RESUMO

This case report underlines the complexity of the transcatheter aortic valve replacement (TAVR) procedure where rare complications sometimes are inevitable, even in experienced hands. Supra-annular dislocation of the balloon-expandable prosthesis was caused by loss of capture of the temporary transvenous pacemaker lead and treated successfully by retracting it towards the abdominal aorta. (Level of Difficulty: Advanced.).

9.
Catheter Cardiovasc Interv ; 91(2): 267-270, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28699262

RESUMO

We present a case of a 47-year-old woman with a mechanical mitral valve prosthesis and recurrent myocardial infarction. The most common etiology of spontaneous myocardial infarction is an acute coronary syndrome caused by rupture or erosion of an atherosclerotic plaque. However, the differential diagnosis in the patient described below also included infarction due to embolization or coronary spasm. It can be challenging to discriminate between the different causes of myocardial infarction based on interpretation of symptoms, physical examination, laboratory tests, and electrocardiography alone. This report illustrates the value of coronary angiography with invasive coronary spasm provocation testing using intracoronary acetylcholine to identify the etiology of her recurrent myocardial infarctions.


Assuntos
Vasoespasmo Coronário/complicações , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Infarto do Miocárdio/etiologia , Acetilcolina/administração & dosagem , Angiografia Coronária , Vasoespasmo Coronário/diagnóstico por imagem , Vasoespasmo Coronário/tratamento farmacológico , Eletrocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/tratamento farmacológico , Valor Preditivo dos Testes , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...